HomeMy WebLinkAboutNC0044725_Inspection_20070525Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
Alan W. Klimek, P.E. Director
Division of Water Quality
May 25, 2007
Paul G Davis
Laurinburg-Maxton Airport Commission
16701 Airport Rd
Maxton NC 28364
SUBJECT: April 24, 2007.. Compliance Evaluation Inspection
Laurinburg-Maxton Airport Commission
Laurinburg Industrial WWTP ..
Permit No: NC0044725
Scotland County
Dear Mr. Davis:
Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on April
24, 2007. The Compliance Evaluation Inspection was conducted. by Dale Lopez, Environmental Specialist, Don
Register, Wastewater Treatment Plant Consultant, and Mark Brantley, Environmental Chemist, of the Fayetteville
Regional Office. The cooperation of Charles Vandenberg, Grade III ORC, was greatly appreciated. The facility
was found to be in Compliance with permit NC0044725. As a reminder, preservation of the Waters of the State can
only be achieved through consistent NPDES Permit compliance.
Comments
• A review of the circular charts for the wastewater treatment plant effluent flow indicated that 66% of the
circular charts were missing during the three period of 2004 through 2006. A total of 57 weekly circular
charts were saved that represented a three-year period that has a total of 156 weeks. The actual numbers
were as follows: zero charts present for the year 2004, twenty present for the year 2005, and thirty-seven
charts were present for the year 2006. There were several charts that had overlapping times, and there was
inconsistency as to the weekday that the chart was started. Since circular charts are a useful tool for
verifying the hand-written totalizer data that are routinely recorded on the Daily Log, it is recommended
that the charts be routinely started on the same day of each week and kept for a minimum of three years.
• This facility has failed the Whole Effluent Toxicity test for the months of March and April 2007.
• Housekeeping is much improved, but needs to continue to be emphasized. The metal structures at the
facility need painting.
• The influent flow meter has,become inoperable during the past year and has not been repaired. Since the
meter is installed it would be proactive to keep it operational for when it is needed.
• At the influent pump station, the'#2 pump is not operable because of a bad starter that has not been
replaced.
North Carolina Division of Water Quality/Aquifer Protection Section 225 Green St./ Suite 714 Fayetteville, NC 28301 Phone (910) 433-3300
FAX (910) 486-0707 Internet: h2o.enr.state.nc.us Customer Service 1-877-623-6748
An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper
NorthCarolina
Naturally
• At the time of the inspection the Tertiary Filters were not operating properly. Filter media is missing from
numerous cells and needs to be replaced. The filters are presently not being used: they are not performing
up to their design because of lack of maintenance. It is highly recommended that a traveling bridge filter
representative evaluate the cost of repairing the filter back to the original specifications.
• Concerning dechlorination, the ratio is two parts of chlorine gas to one part sulfur dioxide gas. Neither the
chlorine nor the sulfur dioxide is flow paced. It is highly recommended that both gases be dosed according
to the effluent flow.
• In the standby power area of the plant, the automatic switch over equipment is not connected and
operational. The influent pumps are not connected to the generator, so the plant cannot operate under the
use of the generator. This must be fixed immediately.
• The bar screen unit operates continuously because the level control has been broken for at least two years
without repair. This is improper operation and maintenance and also needs to be addressed immediately.
Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have
any questions, please call me at 910-433-3327.
Sincerely,
Mark Brantley
Environmental Chemist
Surface Water Protection Section
Fayetteville Regional Office
cc: Charles Gerard Vandenberg, ORC
Central Files
Fayetteville Files
United States Environmental Protection Agency
Washington, D.C. 20460
EPA•
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (Le., PCS)
Transaction Code NPDES yr/mo/day Inspection
1 INI 2. 3I NC0044725 I11 121 07/04/24 117
Type Inspector Fac Type
18ICI- 19ISI 20I II
.
IIIIIIIIIII66
_
Remarks
21IIIIIIIIIIII'IIIII'III111IIIIIIIIIIIII
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ----Reserved
671 169, 701 I 71 I N I 721 NI 731 1174 751 I I I I I I 180
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Laurinburg Industrial WWTP
NCSR 1434
Maxton NC 28364,
Entry Time/Date
09:00 AM 07/04/24
Permit Effective Date
05/06/01
Exit Time/Date
02:00 PM 07/04/24
Permit Expiration Date
09/07/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Charles Gerard Vandenberg/ORC/910-844-5081/
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Paul G Davis,16701 Airport Rd Maxton NC 28364//910-844-5081/9108449681
No
Section C: Areas Evaluated During Inspection (Check only,those areas evaluated)
Permit Flow Measurement � Operations & Maintenance • Records/Reports
Self -Monitoring Program • Sludge Handling Disposal Facility Site Review • Compliance Schedules
Effluent/Receiving Waters • Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signa e(s) of Ins r(s) Agency/Office/Phone and Fax Numbers
Don Regim.- FRO WQ//910-433-3300 Ext.709/
Dale Lopez44111W L FRO WQ//910-433-3300 Ext.712/
Date 9
�� �� �
Mark Brantle FRO WQ//910-433-3300 Ext.727/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers G Date
Belinda S Henson ✓I�t Lit4L" ' !'^�jA+4leu: FRO WQ//910-433-3300 Ext. 726/ 61, 3'5 - 07
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page # 1
31
NPDES yr/mo/day
NC0044725 111 121 07/04/24 I17
Inspection Type
18ICI
(cont.) 1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
A review of the circular charts for the wastewater treatment plant effluent flow indicated that 66% of the
circular charts were missing during the three year period of 2004 through 2006. A total of 57 weekly
circular charts were saved that represented a three year period, that has a total of 156 weeks. The actual
numbers were as follows: zero charts present for the year 2004, twenty present for the year 2005, and
thirty-seven charts were present for the year 2006. There were several charts that had overlapping times,
and there was inconsistancy as to the week day that t he chart was started. Since circular charts are a
useful tool for verifying the hand-written totalizer data that are routinely recorded on the Daily Log, it is
recommended that the charts be routinely started on the same day of each week and kept for a minimum of
three years.
Page # 2
Permit: NC0044725 Owner - Facility: Laurinburg Industrial WWTP
Inspection Date: 04/24/2007 Inspection Type: Compliance Evaluation
Compliance Schedules Is there a compliance schedule for this facility? -
Is the facility compliant with the permit and conditions for the review period?
Comment: This facility failed the Whole Effluent Toxicity test for the month of -March
and April2007.
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • ❑ n n
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ n n n
Judge, and other that are applicable?
Comment: Housekeeping is- much improved, but needs to continue to be
emphasized. The metal structures at the facility need painting.
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new application? • n n Q
Is the facility as described in the permit? ■ n n ❑
# Are there any special conditions for the permit? ■ n n n
Is access to the plant site restricted to the general public? - • n n n
Is the inspector granted access to all areas for inspection? ■ ❑ ❑
Comment: This facility has Aquatic Toxicity and Pretreatment requirements in the
Special Conditions of the NPD ES permit.
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit? ❑ • n n
Is all required information readily available, complete and current? ❑ • El n
Are all records maintained for 3 years (lab. reg. required 5 years)? ❑ ■ n n
Are analytical results consistent with data reported on DMRs? ■ n n fl
Is the chain -of -custody complete? ❑ ❑ n ■
Dates, times and location of sampling
Name of individual performing the sampling ❑
Results of analysis and calibration n,
Dates of analysis
Name of person performing analyses - n
Transported COCs
Are DMRs complete: do they include all permit parameters? • n ❑ n
El
Has the facility submitted its annual compliance report to users and DWQ? • El El
Page # 3
Yes No NA NE
n■nn
norm
Permit: NC0044725 Owner - Facility: Laurinburg Industrial WWTP
Inspection Date: 04/24/2007 Inspection Type: Compliance Evaluation
Record Keeping
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility classification?
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Comment: All of the flowmeter circular charts for the year 2004 were missing,as were
32 for the year 2005, and 15 for the year 2006. Since the flowmeter circular chart
device is installed, it would be proactiv e to keep accurate circular chart records for at
least three years.
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment:
Flow Measurement - Influent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Comment: This meter has become inoperable during the past year and has not been
repaired. Since the meter is installed it would be proactive to keep it operational for
when it is needed.
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Comment:
Aerobic Digester
Is the capacity adequate?
Is the mixing adequate?
Yes No NA NE
n n■n
■ nnn
■ nnn
■ nnn
■ nnn
n nn■
Yes , No NA NE
■ nnn
■ nnn
nn■n
Yes No NA NE
n■nil
n ■nn
■ ■nn
n■nn
Yes No NA NE
■ nnn
■ nnn
■ nnn
■ nnn
Yes No NA NE
■ nnn
nnn■
Page # 4
Permit: NC0044725 Owner - Facility: Laurinburg Industrial WWfP-
Inspection Date: 04/24/2007 Inspection Type: Compliance Evaluation
Aerobic Digester
Is the site free of excessive foaming in the tank?
# Is the odor acceptable?
# Is tankage available for properly waste sludge?
Comment:
Drying Beds.
Is there adequate drying bed space?
Is the sludge distribution on drying beds appropriate?
Are the drying beds free of vegetation?
# Is the site free of dry sludge remaining in beds?
Is the site free of stockpiled sludge?
Is the filtrate from sludge drying beds returned to the front of the plant?
# Is the sludge disposed of through county landfill?
#' Is the sludge land applied?
(Vacuum filters) Is polymer mixing adequate?
Comment:
Pump Station - Effluent
Is the pump wet well free of bypass lines or structures?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Is SCADA telemetry available and operational?
Is audible and visual alarm available and operational?
Comment: SCADA is not available at this time.
Pump Station - Influent
Is the pump wet well free of bypass lines or structures?
Is the wet well free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Is SCADA telemetry available and operational?
Yes No NA NE
■ nnn
■ nnn
■ nnn
Yes . No NA NE
n nn■
n,nn■
nnn.
n nn■
n nn■
nnn■
Elnn■
n nn■
nnn■
Yes No NA NE
■ nnn
■ nnn
■ nDn
■ nnn
n■nn
■ nnn
Yes No NA NE
■ nnn
■ nnn
■ nnn
D•■nn
■ nnn
n ■nn
Page # 5
Permit: NC0044725 Owner - Facility: Laurinburg Industrial WWTP
Inspection Date: 04/24/2007 Inspection Type: Compliance Evaluation
Pump Station - Influent
Is audible and visual alarm available and operational?
Comment: #2 pump is not operable because of a bad starter that has not been
replaced.
Grit Removal
Type of grit removal
a.Manual
b.Mechanical
Is the grit free of excessive organic matter?
Is the grit free of excessive odor?
# Is disposal of grit in compliance?
Comment: This facility does not have grit removal.
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth)
Comment:
Oxidation Ditches
Are the aerators operational?
Are the aerators free of excessive solids build up?
# Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Yes No NA NE
■ nnn
Yes No NA NE
n
n
n ■nn
n ■nn
n ■nn
Yes No NA NE
■ nnn
■ nnn
■ nnn
■ nnn
■ nnn
■ nnn
■ nnn
■ nnn
■ nnn
■ nnn
■ nnn
Yes No NA NE
■ nnn
■ nnn
■ nnn
■ nnn
■ nnn
Page # 6
Permit: NC0044725
Inspection Date: 04/24/2007
Owner - Facility: Laurinburg Industrial WWTP
Inspection Type: Compliance Evaluation
Oxidation Ditches Yes No NA NE
Are settleometer results acceptable (> 30 minutes)? • n n n
Is the DO level acceptable?(1.0 to 3.0 mg/I) ■ n n n
Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes) ■ n n n
Comment:
Filtration (High Rate Tertiary) Yes No NA NE
Type of operation: Down flow
Is the filter media present? n ■ n n
Is the filter surface free of clogging? ❑ ■ n n
Is the filter free of growth? n n n 1
Is the air scour operational? n n ■ n
Is the scouring acceptable? n' n ■ n
Is the clear well free of excessive solids and filter media? ■ n n n
Comment: Filter media is missing from numerous cells and needs to be replac ed. The
filters are presently not being used; they are not per forming upto their design because
of lack of maintenance. It is' highly recommended that a traveling bridge filter
representative evaluate the cost of repairing the filter back to the original specifications.
Disinfection -Gas Yes No NA NE
Are cylinders secured adequately? ■ ❑ ❑ n
Are cylinders protected from direct sunlight? ■ n n
Is there adequate reserve supply of disinfectant? ■ n ❑ n
Is the level of chlorine residual acceptable? • n n n
Is the contact chamber free of growth, or sludge buildup? ■ n n n
Is there chlorine residual prior to de -chlorination? ■ n n n
Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? n n n 1
If yes, then is there a Risk Management Plan on site? n n • n
If yes, then what is the EPA twelve digit ID Number? (1000-
If yes, then when was the RMP last updated?
Comment:
De -chlorination
Type of system ?
Is the feed ratio proportional to chlorine amount (1 to 1)?
Yes No NA NE
Gas
■nnn
Page # 7
Permit: NC0044725 Owner - Facility: Laurinburg Industrial WWTP
Inspection Date: 04/24/2007 Inspection Type: Compliance Evaluation
De -chlorination
Is storage appropriate for cylinders?
# Is de -chlorination substance stored away from chlorine containers?
Are the tablets the proper size and type?
Comment: The ratio is two parts chlorine gas to one part sulfur dioxide gas. Neither
the chlorine nor the sulfur dioxide is flow paced dosage. It is highly recommended that
both gases be dosed according to the effluent flow.
Are tablet de -chlorinators operational?
Number of tubes in use? -
Comment:
Standby Power
Is automatically activated standby power available?
Is the generator tested by interrupting primary power source?
Is the generator tested under load?
Was generator tested & operational during the inspection?
Do the generator(s) have adequate capacity to operate the entire wastewater site?
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
Is the generator fuel level monitored?
Comment: Automatic switch over equipment is not connected and operational. The
influent pumps are not connected to the generator, so the plant cannot operate under
the use of the generator. This must be fixed immediately!
Pumps-RAS-WAS
Are pumps in place?
Are pumps operational?
Are there adequate spare parts and supplies on site?
Comment: The #1 Return Pump was out -of -service because of a bad check valve.
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Yes No NA NE
■ nnn
■ nnn
nn■n
Yes No NA NE
Florin
n ■nn
n ■nn
■ nnn
n ■nn
■ nnn
■ nnn
Yes No NA NE
■ nnn
■ ■nn
■ nnn
Yes No NA NE
■ nnn
■ nnn
■ nnn
■ nnn
n n■n
Page # 8
Permit: NC0044725 Owner - Facility: Laurinburg Industrial WWTP
Inspection Date: 04/24/2007 Inspection Type: Compliance Evaluation
Laboratory Yes No. NA NE
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ n ■
Comment:
Influent Sampling Yes No NA NE
# Is composite sampling flow proportional? - ❑ ■ n n
Is sample collected above side streams? • n ■ n n
• Is proper volume collected? ■ n n n
Is the tubing clean? Florin
Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? ■ n n n
Is sampling performed according to the permit? • n n ❑
Comment: Tubing needs cleaning or changing.
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional? ■ n ❑ ❑
Is sample collected below all treatment units? • n
11
Is proper volume collected? • ❑ n ❑
Is the tubing clean? • Finn
Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? ■ n n n
Is the facility sampling performed as required by the permit (frequency, sampling type representative)? ■ n n n
Comment:
Upstream / Downstream Sampling Yes No NA NE
Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? ■ n. n n
Comment:
Bar Screens
Type of bar screen
a.Manual
b.Mechanical
Are the bars adequately screening debris?
Is the screen free of excessive debris?
Is disposal of screening in compliance?
Is the unit in good condition?
Yes No NA; NE
■
■ nnn
■ nnn
■ nnn
n■nn
Page # •9
Permit: NC0044725 Owner - Facility: Laurinburg Industrial WWTP
Inspection Date: 04/24/2007 Inspection Type: Compliance Evaluation
Bar Screens
Comment: The unit operates continuously because the level control has been broken
for at least two years without repair. This is improper operation and maintenance!
Yes No NA NE
Page # 10