Loading...
HomeMy WebLinkAboutWQ0003380_Additional Information Request_20210910ROY COOPER Governor ELIZABETH S. BISER Secretary S. DANIEL SMITH Director MICHAEL GOLDEN — PLANT MANAGER GEORGIA-PACIFIC WOOD PRODUCTS LLC 139 BREWINGTON ROAD DUDLEY, NORTH CAROLINA 28333 Dear Mr. Golden: NORTH CAROLINA Environmental Quality September 10, 2021 Subject: Application No. WQ0003380 Additional Information Request Georgia-Pacific — Dudley Plywood Facility CLRS Closed -Loop Recycle System Wayne County Division of Water Resources' Central and Regional staff has reviewed the application package received June 28, 2021. However, additional information is required before the review may be completed. Please address the items on the attached pages no later than the close of business on October 11, 2021. Please be aware that you are responsible for meeting all requirements set forth in North Carolina rules and regulations. Any oversights that occurred in the review of the subject application package are still the Applicant's responsibility. In addition, any omissions made in responding to the outstanding items in Sections A through M, or failure to provide the additional information on or before the above requested date may result in your application being returned as incomplete. Please reference the subject application number when providing the requested information. All revised and/or additional documentation shall be signed, sealed and dated (where needed), with an electronic copy submitted to our upload site (URL: hiips://edocs.deg.nc.gov/Fonns/NonDischarg_e- Branch-Submittal-Form-Ver2). If you have any questions regarding this request, please do not hesitate to contact me at (919) 707- 3660 or Lauren.Plummer(ancdenr.gov. Thank you for your cooperation. Sincerely L.1n�,uSid by1vW:Ul1P.GUAP—�QaLWlm i�,Y��§4lummer, Engineer III Division of Water Resources cc: Washington Regional Office, Water Quality Regional Operations Section (Electronic Copy) Donald Baker, PE — Don Baker Engineering LLC (Electronic Copy) Permit Application File WQ0003380 E Q�� North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 NORTH CAROHNA - Deaa�entote.Wro,memsiQuality r 919.707.9000 Mr. Michael Golden September 10, 2021 Page 2 of 4 A. Cover Letter: 1. No comment. B. Application Fee: 1. No comment. C. Application: The wastewater flow, provided under the General Requirements section (Item IV), appears to be for the modifications (e.g. what is to be added to the overall capacity of the system) and a total system capacity was not provided. Looking through the submitted documents, there appears to be a discrepancy regarding the current closed -loop recycle system's capacity. Within the Operation and Maintenance (O&M) Plan the facility is described as a 286,443 gallon per day (GPD) wastewater treatment and closed -loop recycle system; this appears to be the combined volume of the surge basin (121,984 gallons) and the log heating vat water recycle system (164,459 gallons). The existing permit, dated October 29, 2018, lists a total capacity of 221,984 GPD which is the combined volume of the surge basin (same as above) and the log heating vat water recycle system (100,000 gallons). The modifications are purported to add an additional 38,006 gallons which does not account for the difference. Please review and revise the application and provide both the existing, as constructed, facility capacity and the proposed facility capacity upon completion of the vat modifications. Within the application Item V.3., the applicant indicated that the Dudley Plywood Facility closed - loop recycle system has the ability to store the effluent when recycling cannot be conducted as required by 15A NCAC 02U .0404. The proposed modification includes the addition of two (2) 19,003 gallon vats served by singular pumps, and it is unclear if the current facility configuration is sufficient should the equipment within either Vat 8 or Vat 9 become inoperable. The project narrative and O&M plan indicate the water in the "cold water section" is kept low to hold 7 vats in any emergency, but it is unclear whether it is capable of holding 9 vats, as proposed. Is the "cold water section" referring to the surge basin? Additionally, the O&M plan indicates that each chopper pump has a spare in case of failure, are these spares compatible with the proposed chopper pumps in Vats 8 and 9? Please provide additional information and review and revise the submittal, if necessary. D. Property Ownership Documentation: 1. No comment. E. Water Balance: 1. No comment. Mr. Michael Golden September 10, 2021 Page 3 of 4 F. En2ineerin2 Plans: Call -outs or notes indicating the designed freeboard within the proposed vats and moat extension were not provided. It is unclear whether the moat and vats are designed to contain the accumulation of water from a 25-year, 24-hour storm event with 1 foot of freeboard as required pursuant to 15A NCAC 02U .0404(c)(6). Please revise the plans using call -outs or notes to indicate that the requirement is met. G. Specifications: 1. A complete set of specifications are to be provided separate from the engineering plans pursuant to 15A NCAC 02T .0105. Specifications should include material and installation requirements for proposed structures, piping, pumps, and all other appurtenances, at minimum. Specifications must be signed, sealed, and dated by a North Carolina licensed Professional Engineer in good standing. A project construction sequence was not provided, and it is unclear whether the proposed modifications will impede the operation of the existing closed -loop recycle system. Please provide a construction sequence and indicate which tasks (if any) will require bypassing or operations shutdown. H. Engineering Calculations: 1. No comment. I. Site May: The different facility components are depicted piecemeal between several of the engineering drawings. Please provide an additional site map that depicts/identifies the essential components of the closed -loop recycle facility (e.g. the surge basin, vats 1-7, proposed vats 8 and 9, the scrubber/clarifier, the ash settling basins, the veneer dryer washdown storage tank) as required pursuant to 15A NCAC 02T .0105(c)(5). Please also consider indicating which components are related to the cold -water and hot-water sections as they are designated within the O&M Plan. J. Power Reliability Plan: 1. No comment. K. Operation & Maintenance Plan: 1. See Comments C.1 and C.2. L. Residuals Management Plan: 1. No comment. Mr. Michael Golden September 10, 2021 Page 4 of 4 M. Additional Documentation: ➢ Certificate of Public Convenience and Necessity: 1. Not applicable. ➢ Existing Permit: 1. No comment. ➢ Final Environmental Document: 1. Not applicable. ➢ Floodway Regulation Compliance: 1. Not applicable. ➢ Threatened or Endangered Aquatic Species Documentation: 1. No comment. ➢ Wastewater Chemical Analysis: 1. A wastewater chemical analysis was not provided. Please confirm that no changes to the composition of the recycled industrial effluent have occurred since the last permit issuance.