Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW3210601_Plansheet - SCM Detail_20210908
CONSTRUCTION GUIDELINES FOR SAND FILTRATION BASIN Amicus Partners, PLLC Firm License # P-1191 30 Union Street South Concord, NC 28025 Civil Site Design Low Impact Development Small —Scale Building Design Telephone: 704.573.1621 Facsimile: 704.248.7951 Seals: �o pF E S S/ p ♦�� Qom` N9! •' i SEAL 032006 10 VrC 01rCVINVLrN rVU rlrL.rLFCFVrC/1IIVINJ Jn/ALL DC rLrC 01-25-2021 5(,AKI h Y ICU I I UM A MINIMUM REFERENCES: MANUAL OF STORMWATER BEST MANAGEMENT PRACTICES; NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES " "' OF 3—FEET AASHTO M278 FOR PVC PIPE,OR BE 3/8—INCH IN TOWN OF HUNTERSVILLE WATEROUALITY DESIGN MANUAL (JUNE 2013 EDITION) `""""""' ••• CHARLOTTE-MECKLENBURG BMP DESIGN MANUAL (REVISED JULY 2013) �� 4B DIAMETER SPACED 3 INCHES ON CENTER ALONG ADMINISTRATION MANUAL FOR IMPLEMENTATION OF THE POST-CONSTRUCTIONSTORMWATERORDINANCE(REVISEDJUNE2013) TYPICAL SECTION 4 LONGITUDINAL ROWS THAT ARE SPACED 90° APART. NOT TO SCALE THE PIPES SHALL HAVE A MINIMUM SLOPE OF 0.5%. SAND FILTER MAINTENANCE TA5K5 AND 5CHEDULE I I I I I I I I I I I I 1 11 11" IIA' Vil r I ODD I LENGTH = 40.00 FT SLOPE = 0.7% r VERTICAL GRAPHIC SCALE (PROFILE VIEW) 1 INCH = 10 FEET I 10 0 5 10 20 i I lHHHHHHHHHHHH c I i I GRAPHIC SCALE (PLAN VIEW) 30 0 15 30 60 SPECIFICATION/TEST METHOD SIZE NOTES MATERIAL Sand substitutions such as Diabase and Graystone #10 are not acceptable. No ASTM-C-33 concrete sand 0.02" to 0.04" calcium or dolomitic sand substitutions are Sand acceptable. No "rock dust" can be used for sand. Ash content < 15%, The material must be reed -sedge humic peat, pH range: 5.2 to 4.9, n/a shredded, uncompacted, uniform and clean. Loose bulk density (For open and sand filter only). Peat Underlain Gravel blue stone, double washed, #57 stone 0.5" to 1.5" 4" min. over underdrain and max of 12" total Must maintain 125 gpm/ft^2 flow rate. Note: a 0.08" thick Geotextile Fabric MIRAFI 140 OR EQUAL 4" pea gravel layer may be substituted for equivalent opening (if required) geotextiles meant to "separate" sand filter size of #80 sieve layers. ASTM-D-4833 (Thickness) ASTM-D-412 (Tensile strength 1,100 lb, Impermeable Liner p elongation 200 percent) Liner to be ultraviolet -resistant. A geotextile 30 mil thickness fabric should be used to protect the liner from ASTM-D-624 (tear resistance - 150 Win) puncture. ASTM-D-471 (water absorption: +8 to 2% mass) Min. 6" perforated Scheduled 40 3/8" pert. @ 3" O/C along 4 longitudinal rows that are Underlain Piping AASHTO-M-278 (PVC) or stronger PVC or double spaced 90 degrees apart. Pipes shall have a min. slope AASHTO-M-252 (HDPE) wall HDPE of 0% and max spacing of 10' O.C. On -site testing of poured -in -place concrete required: 28-day strength and slump test; all Concrete (cast-in- Fe=3,500 psi, normal weight, concrete design (cast -in -place or pre -cast) not place) air -entrained, reinforced to meet ASTM-615-69 n/a using previously approved state or local standards requires design drawings sealed and approved by a licensed, professional structural engineer. Concrete (pre -cast) Per pre -cast concrete manafacturer n/a Non-rebar steel ASTM A-36 n/a TASK SCHEDULE INSPECT BANKS AND SURROUNDING DRAINAGE AREAS FOR EROSION AND STABILIZE IF NECESSARY MONTHLY STREET SWEEP PARKING LOT QUARTERLY TRASH REMOVAL MONTHLY INSPECT OUTLET FOR OBSTRUCTIONS MONTHLY INSPECT FOR CLOGGING MONTHLY INSPECT INLET GRATES MONTHLY SKIM SAND MEDIA YEARLY PUMP OIL AND GRIT FROM SEDIMENTATION CHAMBER YEARLY OR AT 50% FULL REPLACE SAND MEDIA AS NEEDED (EXPECT 3 YEARS) GRA55ED SAND FILTER MOW BASIN TO RECOMMENDED HEIGHT IN ALTERNATING PATTERNS TO PREVENT COMPACTION AND PREVENT WEED GROWTH. BAG CLIPPINGS TO PREVENT THATCH BUILT-UP. WEEKLY TO BI-WEEKLY DURING THE GROWIN SEASON, AS NEEDED OTHER SEASONS LIGHT FERTILIZING TO ESTABLISH HEALTHY ROOTS ONLY DURING THE FIRST 2 YEARS AERATE AND DETHATCH BASIN FLOOR EVERY 2 YEARS Z 0 v J Z ^ < U aIf,fl, rQJtr< I,nN Itmlum ulmtINJIUINJJ V/-ll V LJ 1 I L. I L „ a #5 REBAR MAT @ 12" ON CENTER I �SF-1 °� IN EACH DIRECTION �' SINGLE 6" ORIFICE lilil fffoyollELEVATION ® CENTER OF ORIFICE = 811.59—FT LAN AND r L fi i O M., racy i iuu iui v O ���0rrrr , CONCRETE PIPE LEAVING THE RISER I w ,,, � ����� ���� �° uw„".. . ..x MUST BE 0—RING PIPE DETAILS I 0° ,� u yIT �,�, sr „„, HARD PIPE TO UNDERDRAIN w , " Sheet No: TRASH RACK NOTES: --- COLLECTION SYSTEM EACH TRASH RACK IS TO BE CONSTRUCTED OF #3 REBAR, MUST BE i `` 5' X 5' X 1.0' GALVANIZED PRIOR TO FINAL ASSEMBLY. OPENINGS ARE TO BE NO MORE 3,500 PSI CONCRETE SPREAD FOOTING r THAN 6" SQUARE. THE ORIFICE TRASH RACKS ARE TO BE ASSEMBLED WITH (2) REBAR MATS CONSISTING OF #5 REBAR IN ONE PIECE, AND THE TOP TRASH RACK IS TO BE ASSEMBLED IN 4 12" ON CENTER IN EACH DIRECTION COPYRIGHT © 2019 AMICUS PARTNERS, PLLC. SEPARATE PIECES AND BOLTED NOT WELDED FOR FINAL ASSEMBLY. ALL RIGHTS RESERVED. REPRODUCTION OR USE OF THE CONTENTS ( ) TOP VIEW � RISER STRUCTURE DETAIL Doc MIENT,CINMWHOLE OR IINENT, OR IPART, WITHOUTOR nWRITTEN COONS TO INSENT ADJACENTEPROPERTIES, PROPERTY DIMENSIONS, IONS, ANDTICOORDON RINATES RETHIS OFERENC PERTY D FROM AND TRASH RACK SHALL HAVE A HINGED PANEL FOR WORKER ACCESS. 5'2 SCALE: N.T.S. ALL PARCEL AND BOUNDARY (SEE ABOVE DETAIL) OF AMICUS PARTNERS, IS STRICTLY PROHIBITED. ONLY COPIES FROM THE ORIGINAL OF THIS DOCUMENT, AS APPROVED BY CABARRUS COUNTY GIS. THE ENGINEER SHALL BE CONSIDERED TO BE VAUD, TRUE COPIES. 'ANAN . ............... .. . .. . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. .. . . . .. .. .. .. .. .. .. .. .. .. .. .. .. . . . . ............. .. .. .. .. .. .. ..