Loading...
HomeMy WebLinkAboutNC0069841_Bypass of Treatment_20210907Strickland, Bev From: Wyatt Howell <wyatt.howell@unioncountync.gov> Sent: Thursday, September 2, 2021 11:39 AM To: Bart Farmer; Scheller, Roberto Subject: [External] Crooked Creek Sand Filter Bypass 9-2-2021 Attachments: Crooked Creek Bypass 9-2-21.doc CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Roberto, please see the attached 5 day report for the Crooked Creek sand filter bypass from 9/1/21— 9/2/21. Wyatt Howell Crooked Creek Interim Chief Operator 1 W/WW Division T 704-280-6399 Wyatt.howell@unioncountync.gov www.unioncountync.gov (6) UNION COUNTY WAT E R Union County Government 4600 Goldmine Rd, Suite 0104 Monroe, NC 28110 I. North Carolina Department of Environment and Natural Resources DWR Division of Water Resources WWTP Upset , Spill, or Bypass 5-Day Reporting Form (Please Print or Type Use Attachments if Needed) Permittee: Union County Public Works Permit Number: NC0069841 Facility Name: Crooked Creek WWTP #2 County: Union Incident Started: Incident Ended: Level of Treatment: Date: 9/1/21 Time: 2001 Date:9/2/21 Time: 0852 None Primary Treatment X Secondary Treatment X Chlorination/Disinfection Only Estimated Volume of Spill/Bypass: 1.54 MG (must be given even if it is a rough estimate) Did the Spill/Bypass reach the Surface Waters? Yes If yes, please list the following: Volume Reaching Surface Waters: 1.54 MG Surface Water Name: Crooked Creek Did the Spill/Bypass result in a Fish Kill? No Was WWTP compliant with permit requirements? Yes Were samples taken during event? No Source of the Upset/Spill/Bypass (Location or Treatment Unit): Crooked Creek had a surge of flow from a passing heavy thunderstorm. At the time the tertiary sand filters were backwashing continuously and would not keep up. The tertiary filters were put into bypass until flows could return to a point that the filters could be placed back into service. Cause or Reason for the Upset/Spill/Bypass: 2.3 inches of rain in a short amount of time causing elevated flow to the plant. Describe the Repairs Made or Actions Taken: Filters in bypass until the flows reduced. Spill/Bypass Reporting Form (August 2014) WWTP Upset , Spill, or Bypass 5-Day Reporting Form Page 2 Action Taken to Contain Spill, Clean Up and Remediate the Site (if applicable): n/a Action Taken or Proposed to be Taken to Prevent Occurrences: There is ongoing inspections and repair of the collections system. This action has helped with maintaining the fight against I&I. Additional Comments About the Event: Contacted Roberto Scheller at 0837 on 9/2/21, spoke to him again at 1115 to make sure I completed form right. Alex Laytham is no longer ORC, the ORC is now Wyatt Howell. 24-Hour Report Made To: Division of Water Resources X Emergency Management Contact Name: Roberto Scheller Date: 9/2/21 Time: 704-677-2315 Other Agencies Notified (Health Dept, etc): Person Reporting Event: Wyatt Howell Phone Number: 704-280-6399 Did DWR Request an Additional Written Report? No If Yes, What Additional Information is Needed: Spill/Bypass Reporting Form (August 2014)