Loading...
HomeMy WebLinkAboutNC0021661_Technical Assistance_20070111January 11, 2007 David Robinson Pilkington North America Inc Hwy. 74 E Laurinburg NC 28352 Michael F. Easley, Governor William G. Ross Jr., Secretary" North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality SUBJECT: November 14, 2006 Technical Assistance Inspection Pilkington North America Inc Plant 75 Permit No:: NC0049514 Scotland County Dear : Mr. Robinson Enclosed please find a copy of the Technical Assistance Inspection form from the inspection conducted on November 14, 2006. The Technical Assistance Inspection was conducted by Mark Brantley, Environmental Chemist, of the Fayetteville Regional Office. The cooperation of Shaunna Johnson,.Environmental.Cotnpliance Manager, was greatly appreciated. The facility was found to.be in Compliance witli permit NC0049514. As a reminder, preservation of the Waters of the State can only be achieved through consistentNPDES Permit compliance. Please refer to the enclosed inspection report for additional observations and comments. If you or. your staff have any questions, please call me at 910-433-3300. Sincerely, Mark Brantley Environmental Chemist Fayetteville Regional Office cc: Shaunna Michele Johnson Central Files Fayetteville Files North Carolina Division of Water Quality/Aquifer Protection Section 225 Green St./ Suite 714 Fayetteville, NC 28301 Phone (910) 433-3300 Customer Service 1-877-623-6748 FAX (910) 486-0707 Internet: h2o.enr.state.nc.us One NorthCarolina Naturally An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper ' United States Environmental Protection Agency EPA Washington,'D.C. 20460' Water Compliance Inspection Report Form Approved.. OMB No. 2040-0057 . Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 INI 2 ISI 31 NC0049514. 111 121 06/11/14 117 Type Inspector Fac Type 18-I Io 19�120II i Remarks 211IIIIIIIIIIII-III.I.IIIIIIIIIIII'IIIII:II.-IIIIIIIIII-166 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 169 70 13 I 711 I 72 I NI 731 I 174 751 1 I 1 1 1 I - 180 Section B: Facility -Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) • Pant. 75:. Lye Hwy '74" E ; Laurinburg NC 28352 Entry Time/Date 01:30 PM 06/11/14 Permit Effective Date 06/01/01 Exit Time/Date 02:15 PM 06/11/14 Permit Expiration Date 09/08/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// - Shaunna Michele Johnson/ORC/910-291-2737/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted David. Robinson,Hwy 74 E Laurinburg NC 28352//910-291-2635/ No - Section C: Areas Evaluated. During Inspection (Check only those areas evaluated) Other Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Mark Brantley FRO WQ//910-433-3300 Ext.727/ V te4, /- if - 07 Signature of Managem-nt Q A Reviewer Agency/Office/Phone and Fax Numbers Dale l;i. /V /U EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES yr/mo/day Inspection Type 31 _ Ill 1217 18 1 NC0049514 06/11/14 11 DI (cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) A technical assistance visit was performed at the request of the facility to help determine why, chlorine was being detected at levels greater than the NPDES discharge permit allowed in the effluent disaharge. .After talking with Shauna Johnson (Environmental Manager for Pilkington);: Ricky Odum (ORC for the domestic wastewater plant at Pilkington), and Hach,technical essistapcegroup it was thought that oxidized Manganese or Chromium could be causing interference iri the Uttre Low Level Chlorine Test. The Hach technical support group recommended treating the sample with reagents -from the troubleshooting guide to eliminate the inference. Since this has been incorporated in the testing procedures the results from the Ultra Low Level Chlorine Test have been below permitted limits. It was then concluded that oxidized Manganese or Chromium was causing interference in the testing procedure. Page # 2