Loading...
HomeMy WebLinkAboutNCG240019_2021 DMR_20210813E�BURae � o u � w 2 '/ II t y �e ��h CAR�y MECKLENBURG COUNTY Land Use & Environmental Services Agency Solid Waste August 12, 2021 DEQ Mooresville Regional Office Attn: DEMLR Stormwater Program 610 East Center Avenue Suite 301 Mooresville, NC 28115 Attention: Central Files Subject: Discharge Monitoring Report Mecklenburg County Compost Central (new) — Certificate of Coverage No. NCG240019 Dear Central Files: Please find enclosed the Discharge Monitoring Report, August 2021, for Mecklenburg County Compost Central (new), a Type I facility located at 140 Valleydale Road, North Carolina. If you have any questions, please contact me at 704-634-7705 or by email at khaliem.adamsgmecklenbur cg oun nc.g_ov. Sincerely, ;v4j�— 1 Khaliem Adams Solid Waste Environmental Specialist Enclosed: 2021 DMR PEOPLE • PRIDE PROGRESS • PARTNERSHIP 2145 Suttle Avenue Charlotte, North Carolina 28208 www.wipeoutwaste.com NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG240000 Compost Operations Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG24 0019 Person Collecting Samples: Khaliem Adams Facility Name: Mecklenburg County Compost Central (new) Laboratory Name: Pace Analytical Facility County: Mecklenburg Laboratory Cert. No.: Discharge during this period: ✓❑ Yes ❑ No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? ❑✓ Yes ❑ No If so, which Tier (I, II, or III)? Tier 1 A copy of this DMR has een ploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR 0Yes ❑ No ✓' ,, r Date Uploaded: J d (�(::1, Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall 1 Outfall Outfall Outfall Outfall Code N/A Receiving Stream Class N/A Date Sample Collected MM/DD/YYYY 8/3/2021 46529 24-Hour Rainfall in inches 0,20 in C0530 TSS in mg/L (100) 35.0 00340 Chemical Oxygen Demand (120) 112 31615 Fecal Coliform in colonies per 100 ml 872 (1000) 600 Total Nitrogen in mg/L (30) 2.3 665 Total Phosphorus in mg/L (2) 1.8 400 pH in standard units (6.0-9.0) 8.28 Copper, total recoverable in mg/L 01119 (0.010) <0.0050 Lead, total recoverable in mg/ L 01051 (0.075) <0.0050 Zinc, total recoverable in mg/ L 01094 (0.126) <0.010 Additional parameters for outfalls in drainage areas that use >55 gallons per month of new hydraulic oil on average 00552 Non Polar Oil & Grease in mg/L (15) <4.9 Estimated New Motor/Hydraulic Oil NCOIL Usage in gal/month 75 gal/month Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false informa�including the possibility of fines and imprisonment for knowing violations." Signature of Permittee or Delegated Authorized Individual Date Email Address Phone Number Facility Name I Sample Location Sample Time pH Date Device Used to Sample Mecklenburg County Compost Central (new) I Outfall 1 1203 8.28 8/3/2021 Horiba pH Meter (�Ia'ne Analytical www.pacelabs.com August 10, 2021 Darren Steinhilber Mecklenburg County Solid Waste 2145 Suttle Ave Charlotte, NC 28208 RE: Project: Compost Central 2 Pace Project No.: 92553177 Dear Darren Steinhilber: Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Enclosed are the analytical results for sample(s) received by the laboratory on August 03, 2021. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services -Asheville • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Matthew Brainard matthew.brainard@pacelabs.com (704)875-9092 Project Manager Enclosures cc: Khaliem Adams, Meclenburg County Solid Waste REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: Compost Central 2 Pace Project No.: 92553177 Pace Analytical Services Charlotte 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 Louisiana/NELAP Certification # LA170028 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 North Carolina Drinking Water Certification #: 37712 CERTIFICATIONS South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Virginia/VELAP Certification #: 460221 North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 SAMPLE ANALYTE COUNT Project: Compost Central 2 Pace Project No.: 92553177 Lab ID Sample ID Method Analysts Analytes Reported Laboratory 92553177001 Outfall 1 EPA 1664B CJM 1 PASI-C EPA 1664B CJM 1 PASI-C EPA200.7 Rev 4.4 1994 SH1 3 PASI-A SM 9222D-2006 KDF 1 PASI-C SM 254OD-2011 MJP 1 PASI-A TKN+NO3+NO2 Calculation EWS 1 PASI-A EPA 351.2 Rev 2.0 1993 MFO 1 PASI-A EPA 353.2 Rev 2.0 1993 KDF1 1 PASI-A EPA 365.1 Rev 2.0 1993 MFO 1 PASI-A SM 5220D-2011 JP1 1 PASI-A PASI-A = Pace Analytical Services - Asheville PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: Compost Central 2 Pace Project No.: 92553177 Sample: Outfall 1 Lab ID: 92553177001 Collected: 08/03/21 12:20 Received: 08/03/21 14:25 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Oil and Grease ND mg/L 4.9 1 08/08/21 11:27 1664 SGT-HEM, TPH Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Total Petroleum Hydrocarbons ND mg/L 4.9 1 08/08/21 11:27 200.7 MET ICP Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 Pace Analytical Services - Asheville Copper ND mg/L 0.0050 1 08/06/2103:31 08/06/2118:15 7440-50-8 Lead ND mg/L 0.0050 1 08/06/2103:31 08/06/2118:15 7439-92-1 Zinc ND mg/L 0.010 1 08/06/2103:31 08/06/2118:15 7440-66-6 MBIO 9222D Fecal Coliform CHT Analytical Method: SM 9222D-2006 Preparation Method: SM 9222D-2006 Pace Analytical Services - Charlotte Fecal Coliforms 872 CFU/100 mL 1.0 1 08/03/21 15:17 08/04/21 13:45 2540D Total Suspended Solids Analytical Method: SM 2540D-2011 Pace Analytical Services - Asheville Total Suspended Solids 35.0 mg/L 8.3 1 08/05/21 09:47 Total Nitrogen Calculation Analytical Method: TKN+NO3+NO2 Calculation Pace Analytical Services - Asheville Total Nitrogen 2.3 mg/L 0.52 1 08/10/21 15:54 351.2 Total Kjeldahl Nitrogen Analytical Method: EPA 351.2 Rev 2.0 1993 Preparation Method: EPA 351.2 Rev 2.0 1993 Pace Analytical Services - Asheville Nitrogen, Kjeldahl, Total 2.0 mg/L 0.50 1 08/05/21 18:27 08/06/21 05:56 7727-37-9 353.2 Nitrogen, NO2/NO3 pres. Analytical Method: EPA 353.2 Rev 2.0 1993 Pace Analytical Services - Asheville Nitrogen, NO2 plus NO3 0.33 mg/L 0.040 1 08/09/21 10:20 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Rev 2.0 1993 Preparation Method: EPA 365.1 Rev 2.0 1993 Pace Analytical Services - Asheville Phosphorus 1.8 mg/L 0.050 1 08/09/21 13:03 08/10/21 01:03 7723-14-0 5220D COD Analytical Method: SM 5220D-2011 Preparation Method: SM 5220D-2011 Pace Analytical Services - Asheville Chemical Oxygen Demand 112 mg/L 25.0 1 08/07/21 04:04 08/07/21 07:04 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/10/2021 03:59 PM without the written consent of Pace Analytical Services, LLC. Page 4 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 2 Pace Project No.: 92553177 QC Batch: 638803 Analysis Method: EPA 1664B QC Batch Method: EPA 1664B Analysis Description: 1664 HEM, Oil and Grease Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92553177001 METHOD BLANK: 3353805 Associated Lab Samples: 92553177001 Parameter Units Oil and Grease mg/L LABORATORY CONTROL SAMPLE: 3353806 Parameter Units Oil and Grease mg/L MATRIX SPIKE SAMPLE: 3353807 Parameter Units Oil and Grease mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 08/08/2111:27 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 40 38.3 96 78-114 35650614001 Spike MS MS % Rec Result Conc. Result % Rec Limits Qualifiers 47.7 133 104 42 78-114 M1 MATRIX SPIKE SAMPLE: 3353808 35650394002 Spike MS MS % Rec Parameter Units Result Conc. Result % Rec Limits Qualifiers Oil and Grease mg/L 77.0 38.8 114 97 78-114 SAMPLE DUPLICATE: 3353809 35650614005 Dup Parameter Units Result Result Oil and Grease mg/L 9AJ 9.2J RPD Qualifiers Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/10/2021 03:59 PM without the written consent of Pace Analytical Services, LLC. Page 5 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 2 Pace Project No.: 92553177 QC Batch: 638804 Analysis Method: EPA 1664B QC Batch Method: EPA 1664B Analysis Description: 1664 SGT-HEM, TPH Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92553177001 METHOD BLANK: 3353810 Associated Lab Samples: 92553177001 Parameter Units Total Petroleum Hydrocarbons mg/L LABORATORY CONTROL SAMPLE: 3353811 Parameter Units Total Petroleum Hydrocarbons mg/L MATRIX SPIKE SAMPLE: 3353812 Parameter Units Total Petroleum Hydrocarbons mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 08/08/2111:27 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 20 16.9 84 64-132 35650614001 Spike MS MS % Rec Result Conc. Result % Rec Limits Qualifiers 25.5 66.7 50.3 37 64-132 M1 SAMPLE DUPLICATE: 3353813 35650614005 Dup Parameter Units Result Result Total Petroleum Hydrocarbons mg/L 12.01-1 ND RPD Qualifiers Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/10/2021 03:59 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 2 Pace Project No.: 92553177 QC Batch: 638462 Analysis Method: EPA 200.7 Rev 4.4 1994 QC Batch Method: EPA 200.7 Rev 4.4 1994 Analysis Description: 200.7 MET Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92553177001 METHOD BLANK: 3351948 Matrix: Water Associated Lab Samples: 92553177001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Copper mg/L ND 0.0050 08/06/2116:10 Lead mg/L ND 0.0050 08/06/2116:10 Zinc mg/L ND 0.010 08/06/2116:10 LABORATORY CONTROL SAMPLE: 3351949 Spike LCS LCS % Rec Parameter Units Cone. Result % Rec Limits Qualifiers Copper mg/L 0.5 0.53 107 85-115 Lead mg/L 0.5 0.52 103 85-115 Zinc mg/L 0.5 0.49 98 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3351950 3351951 MS MSD 92551712001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Copper mg/L ND 0.5 0.5 0.50 0.49 100 98 70-130 2 Lead mg/L ND 0.5 0.5 0.50 0.48 98 96 70-130 2 Zinc mg/L 35.5 0.5 0.5 0.52 0.51 96 95 70-130 1 ug/L MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3351952 3351953 MS MSD 92552683012 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Copper mg/L 8.1 ug/L 0.5 0.5 0.52 0.47 102 93 70-130 10 Lead mg/L ND 0.5 0.5 0.48 0.44 95 87 70-130 9 Zinc mg/L 343 0.5 0.5 0.80 0.74 92 79 70-130 9 ug/L Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/10/2021 03:59 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 2 Pace Project No.: 92553177 QC Batch: 637786 Analysis Method: SM 9222D-2006 QC Batch Method: SM 9222D-2006 Analysis Description: 9222D Fecal Coliform(MF) - CHT Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92553177001 METHOD BLANK: 3348442 Associated Lab Samples: 92553177001 Parameter Fecal Coliforms SAMPLE DUPLICATE: 3348443 Parameter Fecal Coliforms Matrix: Water Blank Reporting Units Result Limit Analyzed Qualifiers CFU/100 mL ND 1.0 08/04/21 13:45 92553177001 Dup Units Result Result RPD Qualifiers CFU/100 mL 872 770 12 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/10/2021 03:59 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 2 Pace Project No.: 92553177 QC Batch: 638201 Analysis Method: SM 2540D-2011 QC Batch Method: SM 254OD-2011 Analysis Description: 2540D Total Suspended Solids Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92553177001 METHOD BLANK: 3350548 Associated Lab Samples: 92553177001 Parameter Units Total Suspended Solids mg/L LABORATORY CONTROL SAMPLE: 3350549 Parameter Units Total Suspended Solids mg/L SAMPLE DUPLICATE: 3350719 Parameter Units Total Suspended Solids mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.5 08/05/2109:45 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 250 252 101 90-110 92553184001 Dup Result Result RPD Qualifiers 11600 11800 2 SAMPLE DUPLICATE: 3350720 92553184002 Dup Parameter Units Result Result Total Suspended Solids mg/L 207000 232000 RPD Qualifiers 11 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/10/2021 03:59 PM without the written consent of Pace Analytical Services, LLC. Page 9 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 2 Pace Project No.: 92553177 QC Batch: 638358 Analysis Method: EPA 351.2 Rev 2.0 1993 QC Batch Method: EPA 351.2 Rev 2.0 1993 Analysis Description: 351.2 TKN Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92553177001 METHOD BLANK: 3351323 Associated Lab Samples: 92553177001 Parameter Units Nitrogen, Kjeldahl, Total mg/L LABORATORY CONTROL SAMPLE: 3351324 Parameter Units Nitrogen, Kjeldahl, Total mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.50 08/06/2105:48 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 10 9.5 95 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3351325 3351326 MS MSD 92553064001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Kjeldahl, Total mg/L ND 10 10 7.4 7.8 72 76 90-110 5 M1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3351637 3351638 MS MSD 92552681007 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Kjeldahl, Total mg/L ND 10 10 8.3 8.4 82 82 90-110 1 M1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/10/2021 03:59 PM without the written consent of Pace Analytical Services, LLC. Page 10 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 2 Pace Project No.: 92553177 QC Batch: 638825 Analysis Method: EPA 353.2 Rev 2.0 1993 QC Batch Method: EPA 353.2 Rev 2.0 1993 Analysis Description: 353.2 Nitrate + Nitrite, preserved Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92553177001 METHOD BLANK: 3353859 Associated Lab Samples: 92553177001 Parameter Units Nitrogen, NO2 plus NO3 mg/L LABORATORY CONTROL SAMPLE: 3353860 Parameter Units Nitrogen, NO2 plus NO3 mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.040 08/09/2110:11 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 2.5 2.5 101 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3353861 3353862 MS MSD 92553064002 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, NO2 plus NO3 mg/L 2.2 2.5 2.5 4.6 4.6 98 99 90-110 1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3353863 3353864 MS MSD 92553064003 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, NO2 plus NO3 mg/L 2.2 2.5 2.5 4.6 4.5 96 95 90-110 0 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/10/2021 03:59 PM without the written consent of Pace Analytical Services, LLC. Page 11 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 2 Pace Project No.: 92553177 QC Batch: 638644 Analysis Method: EPA 365.1 Rev 2.0 1993 QC Batch Method: EPA 365.1 Rev 2.0 1993 Analysis Description: 365.1 Phosphorus, Total Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92553177001 METHOD BLANK: 3352836 Associated Lab Samples: 92553177001 Parameter Units Phosphorus mg/L LABORATORY CONTROL SAMPLE: 3352837 Parameter Units Phosphorus mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.050 08/10/2100:50 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 2.5 2.5 100 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3352838 3352839 MS MSD 92552411001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Phosphorus mg/L 2.2 2.5 2.5 4.6 4.7 97 99 90-110 1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3352840 3352841 MS MSD 92552414001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Phosphorus mg/L ND 2.5 2.5 2.5 2.6 101 102 90-110 1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/10/2021 03:59 PM without the written consent of Pace Analytical Services, LLC. Page 12 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 2 Pace Project No.: 92553177 QC Batch: 638741 Analysis Method: SM 5220D-2011 QC Batch Method: SM 5220D-2011 Analysis Description: 5220D COD Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92553177001 METHOD BLANK: 3353620 Associated Lab Samples: 92553177001 Parameter Units Chemical Oxygen Demand mg/L LABORATORY CONTROL SAMPLE: 3353621 Parameter Units Chemical Oxygen Demand mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 25.0 08/07/2106:58 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 750 767 102 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3353622 3353623 MS MSD 92551997001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Chemical Oxygen Demand mg/L 32.1 100 100 138 138 106 106 90-110 0 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3353624 3353625 MS MSD 92552112001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Chemical Oxygen Demand mg/L ND 100 100 110 112 101 103 90-110 2 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/10/2021 03:59 PM without the written consent of Pace Analytical Services, LLC. Page 13 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALIFIERS Project: Compost Central 2 Pace Project No.: 92553177 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis ofAcrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. ANALYTE QUALIFIERS M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 08/10/2021 03:59 PM without the written consent of Pace Analytical Services, LLC. Page 14 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Pace Project No.: Compost Central 2 92553177 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92553177001 Outfall 1 EPA 1664B 638803 92553177001 Outfall 1 EPA 1664B 638804 92553177001 Outfall 1 EPA 200.7 Rev 4.4 1994 638462 EPA 200.7 Rev 4.4 1994 638510 92553177001 Outfall 1 SM 9222D-2006 637786 SM 9222D-2006 637787 92553177001 Outfall 1 SM 254OD-2011 638201 92553177001 Outfall1 TKN+NO3+NO2 639311 Calculation 92553177001 Outfall 1 EPA 351.2 Rev 2.0 1993 638358 EPA 351.2 Rev 2.0 1993 638497 92553177001 Outfall 1 EPA 353.2 Rev 2.0 1993 638825 92553177001 Outfall 1 EPA 365.1 Rev 2.0 1993 638644 EPA 365.1 Rev 2.0 1993 639050 92553177001 Outfall 1 SM 5220D-2011 638741 SM 5220D-2011 638753 Date: 08/10/2021 03:59 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 15 of 18 UuurnienL rvdrne: Sample Condition Upon Recei acmnaoical— Document No.: F•CAR-CS-033-Rev.07 uucumem nevisem uciooer Its, GVLu SCURI Page 1 of 2 Issuing Authority: Pace Carolinas Quality Office Laboratory receiving samples: Asheville ❑ Eden❑ Greenwood [] Huntersville f7 Client Na Commercial ❑Pace ❑other; Raleigh❑ Mechanicsville❑ Atlanta❑ Kernersville❑ Project il: WO#:92553177 mcliont II I Ili II III IIIIIIII 111 92553177 Custody Seal Present? ❑Yes E]No Seals Intact? []Yes ®No Date/Initials.Rer•6on•EMamining•Gontent C � Packing Material: LBLbble Wrap ❑Bubble Sags 'foNone ❑ Other Biological Tissue Frozen? Thermomet r: (-]Yes ❑No gN/A Wet ❑Blue []NoneIR Gun ID: 92TO64 Type of Ice; Correction Factor, Cooler Temp: Add/Subtract (°C) _0.1 Temp should be above freezing to 6°C ❑Samples out of temp criteria. Samples on ice, cooling process Cooler Temp Corrected (TI: r has begun USDA Regulated Sail ( E] N/A, water sample) Old samples originate in a quarantine zone within the United States: CA, NY, or SC (check maps)? Did samples originate from a foreign source (internationally, I—IYas r7Nn ,. l...4;, u,,."r;, 4 n..e..., o:, i5 r7v-. r-ln. . Camments/Discrepancy: Chain of Custody Present? "UYes ❑No ❑N/A 1. Samples Arrived within Hold Time? QSYes No [-)N/A 2. Short Hold Time Analysis (c72 hr.)? []Yes EJNo ❑N/A 3. Rush Turn Around Time Requested? [—]yes E No ❑N/A 4. Sufficient Volume? '[r']Yes ❑No ❑N/A 5. Correct Containers Used? -Pace Containers Used? JDYes EaYeS ❑No []No ❑N/A ❑N/A 6. Containers Intact? ®Yes [—]No ❑N/A 7. Dissolved analysis: Samples Field Filtered? ❑Yes ❑Na ❑N/A a. Sample Labels Match COC? -Includes Date/Time/ID/Analysis Matrix: T3Ye5 __5 / f_ __ ❑No ❑N/A 9. Headspace in VDA Vials (>5.6mm)? ❑Yes ❑No ❑N/A 10. Trip Blank Present? Trip Blank Custody Seals Present? []Yes (-]Yes []No []No QN/A []N/A 11. COMMENTS/SAMPLE DISCREPANCY Lot ID of split containers: CLIENT NOTIFICATION/RESOLUTION Person contacted: Project Manager SCURF Review: Date/Time: Date: Field Data Required? ❑Yes []No Project Manager SRF Review: Date: Page 16 of 18 Document Name: Document Revised: October 28, 2020 Document No.: F-CAR-CS-033-Rev.07 *Check mark top half of box if pH and/or dechlorination is verified and within the acceptance range for preservation samples. Exceptions: VOA, Coliform, TOC, Oil and Grease, DRO/8015 (water) DOC, LLHg **Bo-tto.m..half_af box_is_to_list_numb.er_of_b.ottles—__._....... Issuing Authority: pare Carolinas Quality Office Project# 40-#---'W553177 PM: MWB Due Date: 08/10/21 CLIENT: 92-MECK CO y u U Z a z z y a c7 o u a z z ar -,..�.7.. _ +� --• •14 Z N A C �T 2 �- M cl V � v v V�V� x W.- 2 a a Q $ u �v n d®q m z U N n '> v� a D 7 a N Z 2 O C l..J y7 r 1+ x Q 1 " O N 7 c 0i kJ a a a n `° 4 m a o E E ¢ E E 'n Q p d O a °' ¢ e E E Ln E a E $ `m _� E J E o E an E us v w = `m = E o W E E -' E J E ' E ro •> -' E E E C E o E J E rl N Vl rl N ,N.� N r-i ri N ry a q -�•. L71 N Q u> a > > vi z N u .a x ti m Jo '+ ui rn ¢ m x a+ m ai a m x 4 .mr x C7 r r a m o u a v m a m a m a m a m d m a m a m t7 Q t7 a 17 a l7 a L7 a C9 a l7 a l7 S C7 ? O ? ut a vA w a yr a m C7 Q W 7 0 C 1N I X� Xv N I 3 4 1 N N 5 6 7 9 N —�s N i N N\\ I 10 N N 11 12 \�SN--LL I �SL- F pH Adjustment Log for Preserved Samples SampSe ID Type of Preservative pH upon receipt Date preservation adjusted Time preservation adjusted Amount of Preservative added tot 4 Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carolina DEHNR Certification Office (i.e. Out of hold, incorrect preservative, out of temp, incorrect containers. Page 17 of 18 m 3 s n o CM rAs •+ j 78 W -4 0 it ? W N .+ ITEM a N o y m- a 3 a e o v _ z n N l0 3 N N E .. p o 3cr o 3 _1 _ Orf.O[ ❑ � o a 3 p m c '2 N n o m �oP�owao��� ft =s' -0 C' O Q # Z m O C O @a a # R MATRIX CODE (see valid codes to left) n m �, -� SAMPLETYPE G=GRAB C=COMP N 3 m Y o m 3 in m y -j m y � H 3 m n N us p cYJ r- w " D Az Z O A 3 3 m C m O o IT p m Z O to En z G y� 3 11 O m rr- i z SAMPLE TEMP AT COLLECTION � irn C 0 W eL a ? o im # OF CONTAINERS n W Unpreserved 'o H o' m rn H25D4 @ y o # ?C HNO3 m m ~, HCI � m a N m O 2 � , NaOH d n Na25203 N y -- Methanol s v to Other m Analyses Test YIN n }� TSS m y v 200 7 ICP Metals A IT z u Total Nitrogen (TKN+nitrate c m o 10 3 �r Fecal Coh TPH SGT-HFM 1664 m 7 C Total Phosphorus/COD ' D n Oil and Grease by 1664 N �,j m $ m a � 3 z m A 9 !v TEMP in C y = Residual Chlorine(YIN) DC �' m A m O Received on c (Y(N) o n o ) n Custody Sealed d O Cooler s� o (YIN)N Samples Intact (YIN) li Page 18 of 18 Kirllf Cnvironmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit https://deq.nc.gov/about/divisions/energy-mineral-land- resources/energy-mineral-land-permits/stormwater-pennits/np des-industrial-sw#tab-4 Permit No.: N/C/ Cam/ O'+ll�OlAll� l or Certi Cate of C vera No.: N/GG/A/ / Facility Name: 1� 0 5+ rj%j� / Phone No. County: Lt.(' Inspector: !� (j d Date of Inspection: zo I Time of Inspection: J /9 0 Total Event Precipitation (inches): 0, ��i✓� All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: of Permittee or Designee) 1. Outfall Description: n Outfall No. _i Structure (pipe, ditch, etc.): P, O U I Receiving Stream: I Describe the industrial activities that occur within the outfall drainage area: dj',� Page 1 of 2 SWU-242, Last modified 07/28/2017 2. Color: Describe the color of the disc arge using basic colors (red, bro n, blue, etc.) and tint (light, medium, dark) as descriptors: f Di�� �t f Off) 3. Odor: Describe any dist' ct odors at the chlorine odor, etc.): _A Ut? t may have (i.e., smells strongly of oil, weak 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 2 (3 f 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1 2 3 4 5 7. Is there any foam in the stormwater discharge? O Yes dYNo. 8. Is there an oil sheen in the stormwater discharge? oYes C9'No. 9. Is there evidence of erosion or deposition at the outfall? O Yes O No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe t) �'ht'r Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 07/28/2017 `}•��i 4 .. - fff� � ,dry '}c 2`n•� � R� s .. �� �'� R � } I it � "S ��;�1_ 4 • l`.- ^�'�h'`_ 3 �y. tj(P•i� • a r�.'� s, '�'afr 'A�i�P�//1r5 t.,�:.�', dr'� . ' ' 'l•_ ^r 1 �7 , 1� - •. '` i a' - ^ � _. j�Jr •�",i .mac. S�� �` ' -`' � — ,rt `cam S �� - -. � s ` 4J�il ' > - 4R � •�. ', •AIL- 1 ,� ,,����,�� �,N T �l j� ) "aV-IR"- vi 1 �n `• I�f � � Yjy � y MR -i