Loading...
HomeMy WebLinkAboutNCG240016_2021 DMR_20210810MECKLENBURG COUNTY Land Use & Environmental Services Agency Solid Waste August 2, 2021 DEQ Mooresville Regional Office Attn: DEMLR Stormwater Program 610 East Center Avenue Suite 301 Mooresville, NC 28115 Attention: Central Files Subject: Discharge Monitoring Report Mecklenburg County Compost Central — Certificate of Coverage No. NCG240016 Dear Central Files: Please find enclosed the Discharge Monitoring Report, July 2021, for Mecklenburg County Compost Central, a Type I facility located at 5631 West Blvd, North Carolina. If you have any questions, please contact me at 704- 634-7705 or by email at khaliem.adams@mecklenbur coun ne.gov. Sincerely, Khaliem Adams Solid Waste Environmental Specialist Enclosed: 2021 DMR PEOPLE • PRIDE PROGRESS • PARTNERSHIP 2145 Suttle Avenue Charlotte, North Carolina 28208 www.wipeoutwaste.com NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG240000 Compost Operations Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG24 0016 Person Collecting Samples: Khaliem Adams Facility Name: Mecklenburg County Compost Central Laboratory Name: Pace Analytical Facility County: Mecklenburg Laboratory Cert. No.: Discharge during this period: ✓❑ Yes ❑ No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? ❑✓ Yes ❑ No If so, which Tier (I, II, or III)? Tier 1 A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR ❑✓ Yes ❑ No Date Uploaded:V2120tt j0 o2Od Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall2 Outfall Outfall Outfall Outfall Code N/A Receiving Stream Class N/A Date Sample Collected MM/DD/YYYY 7/8/2021 46529 24-Hour Rainfall in inches 0.37in C0530 TSS in mg/L (100) 16.6 00340 Chemical Oxygen Demand (120) 63.0 31615 Fecal Coliform in colonies per 100 ml 8000 (1000) 600 Total Nitrogen in mg/L (30) 33.8 665 Total Phosphorus in mg/L (2) 0.54 400 pH in standard units (6.0-9.0) 7.26 Copper, total recoverable in mg/L 01119 (0.030) 0.0084 Lead, total recoverable in mg/ L 01051 (0.075) <0.0050 Zinc, total recoverable in mg/ L 01094 (0.126) <0.010 Additional parameters for outfalls in drainage areas that use >55 gallons per month of new hydraulic oil on average 00552 Non -Polar Oil & Grease in mg/L (15) <5.0 Estimated New Motor/Hydraulic Oil NCOIL Usage in gal/month 75.0 Notes (optional): Fecal Coliform and Nitrogen are both over the benchmark. Fecal is to be expected around this time, but we will monitor and see if Nitrogen continues to increase "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false Information, including the possibility of fines and imprisonment for knowing violations." y l Zb i Signature of3'ermittee or Delegated Authorized Individual Email Address / l r.t . Si e Date Phone Number ? �''C', -- 0 i q - ZIP.l-7 Facility Name I Sample Location Sample Time pH Date Device used to Sample Mecklenburg County Compost Central I Outfall 2 1147 7.26 7/8/2021 Horiba pH meter (�Ia'ne Analytical www.pacelabs.com July 15, 2021 Darren Steinhilber Mecklenburg County Solid Waste 2145 Suttle Ave Charlotte, NC 28208 RE: Project: Compost Central 1 Pace Project No.: 92548361 Dear Darren Steinhilber: Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Enclosed are the analytical results for sample(s) received by the laboratory on July 08, 2021. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services -Asheville • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Matthew Brainard matthew.brainard@pacelabs.com (704)875-9092 Project Manager Enclosures cc: Khaliem Adams, Meclenburg County Solid Waste REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: Compost Central 1 Pace Project No.: 92548361 Pace Analytical Services Charlotte 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 Louisiana/NELAP Certification # LA170028 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 North Carolina Drinking Water Certification #: 37712 CERTIFICATIONS South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Virginia/VELAP Certification #: 460221 North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 SAMPLE ANALYTE COUNT Project: Compost Central 1 Pace Project No.: 92548361 Lab ID Sample ID Method Analysts Analytes Reported Laboratory 92548361001 Outfall 2 EPA 1664B CJM 1 PASI-C EPA 1664B CJM 1 PASI-C EPA 200.7 Rev 4.4 1994 IDS 3 PASI-A SM 9222D-2006 KDF 1 PASI-C SM 254OD-2011 ZMC 1 PASI-A TKN+NO3+NO2 Calculation DMN 1 PASI-A EPA 351.2 Rev 2.0 1993 MFO 1 PASI-A EPA 353.2 Rev 2.0 1993 KDF1 1 PASI-A EPA 365.1 Rev 2.0 1993 KDF1 1 PASI-A SM 5220D-2011 JP1 1 PASI-A PASI-A = Pace Analytical Services - Asheville PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: Compost Central 1 Pace Project No.: 92548361 Sample: Outfall 2 Lab ID: 92548361001 Collected: 07/08/21 12:04 Received: 07/08/21 13:20 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual HEM, Oil and Grease Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Oil and Grease ND mg/L 5.0 1 07/14/21 09:49 1664 SGT-HEM, TPH Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Total Petroleum Hydrocarbons ND mg/L 5.0 1 07/14/21 09:49 200.7 MET ICP Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 Pace Analytical Services - Asheville Copper 0.0084 mg/L 0.0050 1 07/13/21 11:50 07/15/21 13:04 7440-50-8 Lead ND mg/L 0.0050 1 07/13/2111:50 07/15/2113:04 7439-92-1 Zinc ND mg/L 0.010 1 07/13/2111:50 07/15/2113:04 7440-66-6 MBIO 9222D Fecal Coliform CHT Analytical Method: SM 9222D-2006 Preparation Method: SM 9222D-2006 Pace Analytical Services - Charlotte Fecal Coliforms 8000 CFU/100 mL 1.0 1 07/08/21 15:57 07/09/21 13:58 2540D Total Suspended Solids Analytical Method: SM 2540D-2011 Pace Analytical Services - Asheville Total Suspended Solids 16.6 mg/L 5.0 1 07/13/21 18:01 Total Nitrogen Calculation Analytical Method: TKN+NO3+NO2 Calculation Pace Analytical Services - Asheville Total Nitrogen 33.8 mg/L 0.52 1 07/15/21 15:58 351.2 Total Kjeldahl Nitrogen Analytical Method: EPA 351.2 Rev 2.0 1993 Preparation Method: EPA 351.2 Rev 2.0 1993 Pace Analytical Services - Asheville Nitrogen, Kjeldahl, Total 31.4 mg/L 2.5 5 07/14/21 19:58 07/15/21 05:10 7727-37-9 353.2 Nitrogen, NO2/NO3 pres. Analytical Method: EPA 353.2 Rev 2.0 1993 Pace Analytical Services - Asheville Nitrogen, NO2 plus NO3 2.4 mg/L 0.040 1 07/13/21 10:56 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Rev 2.0 1993 Preparation Method: EPA 365.1 Rev 2.0 1993 Pace Analytical Services - Asheville Phosphorus 0.54 mg/L 0.050 1 07/15/21 09:15 07/15/21 11:16 7723-14-0 5220D COD Analytical Method: SM 5220D-2011 Preparation Method: SM 5220D-2011 Pace Analytical Services - Asheville Chemical Oxygen Demand 63.0 mg/L 25.0 1 07/13/21 02:22 07/13/21 07:36 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 07/15/2021 08:04 PM without the written consent of Pace Analytical Services, LLC. Page 4 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 1 Pace Project No.: 92548361 QC Batch: 633270 Analysis Method: EPA 1664B QC Batch Method: EPA 1664B Analysis Description: 1664 HEM, Oil and Grease Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92548361001 METHOD BLANK: 3326251 Associated Lab Samples: 92548361001 Parameter Units Oil and Grease mg/L LABORATORY CONTROL SAMPLE: 3326252 Parameter Units Oil and Grease mg/L MATRIX SPIKE SAMPLE: 3326253 Parameter Units Oil and Grease mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 07/14/2109:49 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 40 33.4 84 78-114 35644009002 Spike MS MS % Rec Result Conc. Result % Rec Limits Qualifiers 1.81 44.9 36.9 78 78-114 SAMPLE DUPLICATE: 3326254 92547166001 Dup Parameter Units Result Result Oil and Grease mg/L ND 2AJ RPD Qualifiers Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 07/15/2021 08:04 PM without the written consent of Pace Analytical Services, LLC. Page 5 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 1 Pace Project No.: 92548361 QC Batch: 633278 Analysis Method: EPA 1664B QC Batch Method: EPA 1664B Analysis Description: 1664 SGT-HEM, TPH Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92548361001 METHOD BLANK: 3326271 Associated Lab Samples: 92548361001 Parameter Units Total Petroleum Hydrocarbons mg/L LABORATORY CONTROL SAMPLE: 3326272 Parameter Units Total Petroleum Hydrocarbons mg/L MATRIX SPIKE SAMPLE: 3326273 Parameter Units Total Petroleum Hydrocarbons mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 07/14/2109:49 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 20 16.1 80 64-132 92548201001 Spike MS MS % Rec Result Cone. Result % Rec Limits Qualifiers ND 19.6 21.6 105 64-132 SAMPLE DUPLICATE: 3326274 92547166001 Dup Parameter Units Result Result Total Petroleum Hydrocarbons mg/L ND ND RPD Qualifiers Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 07/15/2021 08:04 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 1 Pace Project No.: 92548361 QC Batch: 632955 Analysis Method: EPA 200.7 Rev 4.4 1994 QC Batch Method: EPA 200.7 Rev 4.4 1994 Analysis Description: 200.7 MET Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92548361001 METHOD BLANK: 3324684 Matrix: Water Associated Lab Samples: 92548361001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Copper mg/L ND 0.0050 07/15/2111:42 Lead mg/L ND 0.0050 07/15/2111:42 Zinc mg/L ND 0.010 07/15/2111:42 LABORATORY CONTROL SAMPLE: 3324685 Spike LCS LCS % Rec Parameter Units Cone. Result % Rec Limits Qualifiers Copper mg/L 0.5 0.52 104 85-115 Lead mg/L 0.5 0.50 100 85-115 Zinc mg/L 0.5 0.49 99 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3324686 3324687 MS MSD 92547452001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Copper mg/L 0.18 0.5 0.5 0.52 0.52 68 69 70-130 1 M1 Lead mg/L ND 0.5 0.5 0.50 0.50 99 100 70-130 2 Zinc mg/L 0.61 0.62 1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3324688 3324689 MS MSD 92547438001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Copper mg/L ND 0.5 0.5 0.71 0.72 142 144 70-130 1 M1 Lead mg/L ND 0.5 0.5 0.51 0.51 102 101 70-130 0 Zinc mg/L ND 0.5 0.5 0.67 0.67 133 133 70-130 0 M1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 07/15/2021 08:04 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 1 Pace Project No.: 92548361 QC Batch: 632256 Analysis Method: SM 9222D-2006 QC Batch Method: SM 9222D-2006 Analysis Description: 9222D Fecal Coliform(MF) - CHT Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92548361001 METHOD BLANK: 3321340 Associated Lab Samples: 92548361001 Parameter Fecal Coliforms SAMPLE DUPLICATE: 3321341 Parameter Fecal Coliforms Matrix: Water Blank Reporting Units Result Limit Analyzed Qualifiers CFU/100 mL ND 1.0 07/09/21 13:58 92548280002 Dup Units Result Result RPD Qualifiers CFU/100 mL 83.0 180 74 D6 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 07/15/2021 08:04 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 1 Pace Project No.: 92548361 QC Batch: 633101 Analysis Method: SM 2540D-2011 QC Batch Method: SM 254OD-2011 Analysis Description: 2540D Total Suspended Solids Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92548361001 METHOD BLANK: 3325493 Associated Lab Samples: 92548361001 Parameter Units Total Suspended Solids mg/L LABORATORY CONTROL SAMPLE: 3325494 Parameter Units Total Suspended Solids mg/L SAMPLE DUPLICATE: 3325989 Parameter Units Total Suspended Solids mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.5 07/13/2117:57 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 250 248 99 90-110 92548361001 Dup Result Result RPD Qualifiers 16.6 20.2 20 SAMPLE DUPLICATE: 3325990 92548514001 Dup Parameter Units Result Result Total Suspended Solids mg/L 132 142 RPD Qualifiers 7 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 07/15/2021 08:04 PM without the written consent of Pace Analytical Services, LLC. Page 9 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 1 Pace Project No.: 92548361 QC Batch: 633366 Analysis Method: EPA 351.2 Rev 2.0 1993 QC Batch Method: EPA 351.2 Rev 2.0 1993 Analysis Description: 351.2 TKN Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92548361001 METHOD BLANK: 3326790 Associated Lab Samples: 92548361001 Parameter Units Nitrogen, Kjeldahl, Total mg/L LABORATORY CONTROL SAMPLE: 3326791 Parameter Units Nitrogen, Kjeldahl, Total mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.50 07/15/2103:50 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 10 10 100 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3326792 3326793 MS MSD 92548143001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Kjeldahl, Total mg/L 0.99 10 10 13.0 12.9 120 119 90-110 1 M1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3326794 3326795 MS MSD 92548161001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, Kjeldahl, Total mg/L 46.9 10 10 58.5 57.2 116 103 90-110 2 M1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 07/15/2021 08:04 PM without the written consent of Pace Analytical Services, LLC. Page 10 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 1 Pace Project No.: 92548361 QC Batch: 632930 Analysis Method: EPA 353.2 Rev 2.0 1993 QC Batch Method: EPA 353.2 Rev 2.0 1993 Analysis Description: 353.2 Nitrate + Nitrite, preserved Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92548361001 METHOD BLANK: 3324630 Associated Lab Samples: 92548361001 Parameter Units Nitrogen, NO2 plus NO3 mg/L LABORATORY CONTROL SAMPLE: 3324631 Parameter Units Nitrogen, NO2 plus NO3 mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.040 07/13/2110:25 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 2.5 2.6 102 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3324632 3324633 MS MSD 92548648003 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, NO2 plus NO3 mg/L 0.41 2.5 2.5 2.9 2.9 99 99 90-110 0 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3324634 3324635 MS MSD 92548732001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Nitrogen, NO2 plus NO3 mg/L ND 2.5 2.5 2.5 2.5 99 99 90-110 0 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 07/15/2021 08:04 PM without the written consent of Pace Analytical Services, LLC. Page 11 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 1 Pace Project No.: 92548361 QC Batch: 633514 Analysis Method: EPA 365.1 Rev 2.0 1993 QC Batch Method: EPA 365.1 Rev 2.0 1993 Analysis Description: 365.1 Phosphorus, Total Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92548361001 METHOD BLANK: 3327544 Associated Lab Samples: 92548361001 Parameter Units Phosphorus mg/L LABORATORY CONTROL SAMPLE: 3327545 Parameter Units Phosphorus mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 0.050 07/15/2111:07 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 2.5 2.6 103 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3327546 3327547 MS MSD 92548212001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Phosphorus mg/L 1.4 2.5 2.5 4.0 4.0 103 102 90-110 0 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3327548 3327549 MS MSD 92548310001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Phosphorus mg/L 0.25 2.5 2.5 2.8 2.8 101 101 90-110 0 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 07/15/2021 08:04 PM without the written consent of Pace Analytical Services, LLC. Page 12 of 18 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Compost Central 1 Pace Project No.: 92548361 QC Batch: 632896 Analysis Method: SM 5220D-2011 QC Batch Method: SM 5220D-2011 Analysis Description: 5220D COD Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92548361001 METHOD BLANK: 3324549 Associated Lab Samples: 92548361001 Parameter Units Chemical Oxygen Demand mg/L LABORATORY CONTROL SAMPLE: 3324550 Parameter Units Chemical Oxygen Demand mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 25.0 07/13/2107:30 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 750 774 103 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3324551 3324552 MS MSD 92547118001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Chemical Oxygen Demand mg/L ND 100 100 114 116 104 106 90-110 2 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3324553 3324554 MS MSD 92547982003 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Chemical Oxygen Demand mg/L 35.3 100 100 139 137 104 102 90-110 2 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 07/15/2021 08:04 PM without the written consent of Pace Analytical Services, LLC. Page 13 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALIFIERS Project: Compost Central 1 Pace Project No.: 92548361 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis ofAcrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. ANALYTE QUALIFIERS D6 The precision between the sample and sample duplicate exceeded laboratory control limits. M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 07/15/2021 08:04 PM without the written consent of Pace Analytical Services, LLC. Page 14 of 18 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Pace Project No.: Compost Central 1 92548361 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92548361001 Outfall 2 EPA 1664B 633270 92548361001 Outfall 2 EPA 1664B 633278 92548361001 Outfall 2 EPA 200.7 Rev 4.4 1994 632955 EPA 200.7 Rev 4.4 1994 633144 92548361001 Outfall 2 SM 9222D-2006 632256 SM 9222D-2006 632257 92548361001 Outfall 2 SM 254OD-2011 633101 92548361001 Outfall2 TKN+NO3+NO2 633734 Calculation 92548361001 Outfall 2 EPA 351.2 Rev 2.0 1993 633366 EPA 351.2 Rev 2.0 1993 633501 92548361001 Outfall 2 EPA 353.2 Rev 2.0 1993 632930 92548361001 Outfall 2 EPA 365.1 Rev 2.0 1993 633514 EPA 365.1 Rev 2.0 1993 633580 92548361001 Outfall 2 SM 5220D-2011 632896 SM 5220D-2011 632934 Date: 07/15/2021 08:04 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 15 of 18 Sample Condition Upon Recei t(SCUR) Page 1 of 2 Document No.: Issuing Authority: F-CAR-CS-033-Rev.07 Pace Carolinas Quality Office Laboratory receiving samples: Asheville ❑ Eden❑ Greenwood ❑ Huntersville'❑ Raleigh❑ Mechanicsville❑ Atlanta[] Kernersville❑ Sample Condition Client Name: WO# : 92548361 Upon Receipt project #: !!II ! ❑ Commercial ❑Pace ❑Other: 92548361 Custody Seal Present? []Yes ❑No Seals Intact? ❑Yes []No I}ate/Initials.Person•fixamining Content Packing Material: ❑bubble Wrap []Bubble Bags ©None ❑ Other Biological Tissue Frozen? ❑Yes ❑No FN/A Thermometer: []wet ❑91ue []None ❑,IR Gun ID: 92TO64 Type of Ice: LA 7 Correction Factor: Add/Subtract C) .0_ 1 Temp should be above freezing to 6°C Cooler Temp: {� � ❑samples out of temp criteria. Samples on ice, cooling process Cooler Temp Corrected ('C): has begun USDA Regulated Soil ( Q N/A, water sample) Did samples originate in a quarantine zone within the United States: CA, NY, or SC (check maps)? Did samples originate from a foreign source {internationally, ❑Yes [:]No including Hawaii and Puerto Rico)? []Yes [:]No Comments/Discrepancy: Chain of Custody Present? Samples Arrived within Hold Time? Short Hold Time Analysis (<72 hr.)? Rush Turn Around Time Requested? Sufficient Volume? Correct Containers Used? -Pace Containers Used? Containers Intact? Dissolved analysis: Samples Field Filtered? Sample Labels Match COC? -includes Date/Time/ID/Analysis Headspace in VOA Vials (>5.6mm17 Trip Blank Present? Trip Blank Custody Seals Present? COMMENTS/SAMPLE DISCREPANCY CLIENT NOTIFICATION/RESOLUTION Person contacted: Project Manager SCURF Review: Project Manager SRF Review: V Yes ❑No [-]N/A I. [Yes ❑No ❑NIA 2. ,Yes ON. ❑N/A 3. [—]yesdNo ❑N/A 4. Yes ❑No []N/A 5. [yes [:]No []N/A 6- [nYes []No (—]N/A Yes ❑No ❑N/A 7, [—]Yes ❑No . N/A 8. 'j�yes ❑No ❑N/A 9. []Yes ONo MYes nNo ❑N/A 1D. ❑N/A 11. Date/Time: Lot ID of splitcontainers: Date: Date: Field Data Required? Dyes ❑No Page 16 of 18 uocurnenL rvarr e: — —-- .._..-. orCrI III Pave 2' c ---------- �� ace nai -cal Document No.: Issuing Authority: r1 F-CAR-CS-033•Rev.07 Pate Carolinas Quality Office *Check mark top half of box if pH and/or dechlorination is Project # WO# : 92548361 verified and within the acceptance range for preservation PM; MWg Due Date: 07/15/21 samples. CLIENT: 92-MECK CO Exceptions: VOA, Coliform, TOC, Oil and Grease, DRO/8015 (water) DOC, LLHg "`*Bctttom._half_of_b_ox_isto_fist-number_of_battles—...-_........ --. - z z U V V 4 Z Z Z m 7 N CCL .-. f�_o v v _ Z z O ? _ Z a S z z a n z QJ a 5 .a v V v a a m ¢ i n � u � i m m a N e O m u x n a v O e m S a z c o a c n cs d d Q O a j E Q O 0 7 F�° O 7 7 T N 2 v 7 S S _ V eq iq c Phi /_+ +' v u � V U V .N U t W G1 ¢ E 2 Z E C m a m b m .V-+ b Y a W 4J 4 Gi O E O ^ Q O p Q Q Q O c. a a! W n M n V1 4 N a E E E ¢ N O. J d J J J E Q Q J ¢ J J J J J A E E E E E 41 �7 m m E a E E E E E ? A E C o 0 o Ln 0 0 o to to = '= u�i N 0 0 0 0 ;Q, IN a N 0 rq 0 1-4 LnU1 rni N N 3 ,. ri N O ? 6 Y IdQ tt i%1 "L N U LL fn N M M 01 iTl.7 y a a a a ei N 4D 0 7 7 0 7 m Q ¢ a a CC 0. m 3 a a a a a a CIO m m to :0co 1 2 3 4 5 6 7 S 9 10 11 12 pH Adjustment Log for Preserved Samples Sample 10 Type of Preservative pH upon receipt Date preservation adjusted Time preservation Amount of Pdrea ervative Lat +Y adjusted Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will he sent to the North Carolina DEHNR Certification Office (Le. Out of hold, incorrect preservative, out of temp, incorrect containers. Page 17 of 18 m � c V (D N 2 L1 A S � n *+ d y E p E G o U e ♦J 7 U E E a e W s o N n ^Q W 7 � y a m C C N !+W � E O QUv O '. m c rn M o i' Q E y � oW,- € Z o C13 C y p a a •I� m O O � � U O � O 1 � Z � � V F- L) 0 U E N . N 6 E N c d U 8 d Y v Q 9 m yl m 9� O r L d Z it v ° : m m r- N W K 0 u ate. d a. A m a o E m N rn {9 sLL � m T � n cn c O y C = ? V 0 d a o v o m N C U m U � p d b 0 m a ' m c w a s cnn Rom' U Q U MEMO . . mom NIA ;sal sasF)euV JBII;(] louey;eyl m £OZSZeN 7 �p HOeN w 10H d £ONN I I -- DQSZH } — panjesaidun� S2i3 NIV1N0030# N0110311001V dW3131dWVS� w 4 ❑ r = Li 1 a ru Li r Q: -- F- U ❑ w O U F r a 0 7 (d W00=D 8V4l0=0) 3dAl3ld WVS - (gal q sepn Alen aes) 3a00 XRIIVYI w 33 ���3amo3ao� c 0 0 A = W CL ; a E _ F S O y N WA) ;oelul saEdwcS z (NIAI O jepc o o palaag 2 O F o1sn LLI (NIA) a 831 Nuo panl80aa �. ' I I I 1 O ul dw3i r w a :Ty # W311 I '�'I HI rll al v7l m rrl m rnl �� �� � w ¢ w w Z J J a in i Z 1¢A N ¢ o Q m w w E Zm Z r w z a ac� yr Page 18 of 18 Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit https://deg.ne.gov/about/divisions/energy-mineral-land- resources/energy-mineral-land-permits/stormwater-permits/nodes-industrial-sw#tab-4 Permit No.: N/C/ G/S/�/id1_Q1O /O / or Certificateo,%-�fCoverage No.: N/C/G/-7 /�/ O/d 1, Facility Name: �V I -e (} k I to bt 1, ( j �.(J UAI / Y (�T My Os� / ; �/V)1104 County: Ck 4 Phone No. �Oq � 6 j � � T70 Inspector: at e G,^(►`, S Date of Inspection: Time of Inspection: Total Event Precipitation (inches): All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: (Signature of Permittee or Designee) 1. Outfall Description: Outfall No. ®2 Structure (pipe, ditch, etc.): Receiving Stream: Describe the industrial activities that occur within the outfall drainage area: Ve h i C (e-, Page 1 of 2 SWU-242, Last modified 07/28/2017 2. Color: Describe the color of (light, medium, dark) as descriptors: _ 3. Odor: Descri any distinct o chlorine odor, etc.): l discharge using basic colors (red, brown, blue, etc.) and tint the discharge may have (i.e., smells strongly of oil, weak 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 0 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1 2 3 4 5 7. Is there any foam in the stormwater discharge? O Yes a. C� 8. Is there an oil sheen in the stormwater discharge? OYes r6 No. 9. Is there evidence of erosion or deposition at the outfall? Q Yes b No. 10. Other Obvious Indicators of Storm,,/w�atter Pollution: / List and describe V0 �� 1k, rS Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 07/28/2017