Loading...
HomeMy WebLinkAboutNCG120080_DMR_20210115DocuSign Envelope ID: B40EBFC5-3D37-4D79-8951-5134B4DODFDO Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG120000 Date submitted January 15, 2021 CERTIFICATE OF COVERAGE NO. NCG12 0 0 H 0 FACILITY NAME south wake MSw Landfill COUNTY wake PERSON COLLECTING SAMPLES Michael J. Liebl (Smith Gardner, Inc) LABORATORY Pace Analytical Lab Cert. If 3773e Comments on sample collection or analysis: Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2020 SAMPLE PERIOD ❑ Jan -June ❑■ July -Dec or X Monthly, December (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA Mother PLEASE REMEMBER TO SIGN ON THE REVERSE 4 ❑ No discharge this periodz Outfall No. Date Sample Collected (mo/dd/yr) 24-hour rainfall amount, Inches' Chemical Oxygen Demand mg/L Fecal Coliform Colonies per 100 mL Total Suspended Solids mg/L PH Standard Units Benchmarks _ - 120 1000 100 or 501 6.0.9.0 Parameter Code - 46529 00340 31616 C0530 00400 SDO-1 12/14/2020 0.80 32.3 63.0 15.6 6.94 SD0-4 12/14/2020 0.80 58.1 2600 201 6.62 SDO-6 12/14/2020 0.80 55.8 2800 238 8.13 , Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. 'For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. C See General Permit text, Table 1, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Note: Results must be reported in numerical format. For example, do not'report Below Detection Limit, BOIL, <PQL, Non -detect, ND, or other similar non - numerical format. When results are below the applicable limits, they must be reported in the format, "<XX ma/L". where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Conversely, where fecal coliform results exceed the dilution upper limit, report the result as ">XX". Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Permit Date: 11/1/2018.5/31/2021 SWU-248, last revised 11/1/2018 Page 1 of 2 DocuSign Envelope ID: B40EBFC5-3D374D79-8951-5134B4DODFDO Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. n No discharge this period' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -Polar Oil & Grease mg/L Total Suspended Solids, mg/L New Motor or Hydraulic Oil Usage, gal/mon Benchmarks _ - is 100 or 504 Parameter Code - 46529 00552 C0530 NCOIL Footnotes from Part A also apply to this Part B Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART 11 SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES 0 NO ❑ IF YES, HAVE YOU CONTACTED THE DEMUR REGIONAL OFFICE? YES Q NO ❑ REGIONAL OFFICE CONTACT NAME: Thad Valentine Mail an oriainal copv of this DMR. Includlna all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the Information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the Information, the information submitted Is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false Information, including the possibility of fines and imprisonment for knowing violations." �Dacusgaed by: MAW Signature of Permit Date: 11/1/2018-5/31/2021 1/25/2021 Date SWU-248, last revised 11/1/2018 Page 2 of 2