HomeMy WebLinkAboutNC0072877_NPDES Permit Renewal_20110720NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Beverly Eaves Perdue Coleen H. Sullins Dee Freeman
Governor • Director Secretary
July 20, 2011
MEMORANDUM
To: Maureen Scardina
Point Source Branch, Expedited Unit
Through: Belinda Henson, Water Quality Regional Supervisor-8/./Stteit 9414614r11)
Fayetteville Regional Office
From: Mark Brantley, Environmental Chemist ; ^•�� l �4 r7 -moo-
Fayetteville Regional Office
SUBJECT: Minor NPDES Permit Renewal
Town of Newton Grove
Town of Newton Grove, WWTP
NPDES Permit No. NC0072877
Sampson County
Please find below, regional comments for the subject minor permit renewal.
• Applicant is not requesting modification of the facility or increasing flow at this time.
• A rating sheet is not attached as no modifications were made to this facility during the previous permit cycle.
• A review of compliance data did not reveal any significant or repetitive violations.
• No significant reports of equipment outages have been reported.
• Currently the effluent limitations and monitoring requirements page requires total phosphorous to be tested
quarterly (The town has interpreted this as once a quarter). However the footnote reads, "The quarterly average
for total phosphorus shall be the average of samples collected weekly during each calendar quarter." There is
some confusion on this as to what is required.
The facility -has asked that the following be considered:
• The town has asked that the testing frequency for Total Nitrogen and Total Phosphorus remain the same
(quarterly sampling). During the last permit cycle it was proposed that Total Nitrogen and Total Phosphorus be
monitored three times a week. The town appealed this and was able to prove this would be a financial hardship.
The monitoring requirements were then reduced to quarterly.
• The town has also asked if the upstream and downstream fecal requirement be dropped.
The Fayetteville Regional Office agrees in re-issuing.this permit in keeping with the Cape Fear River Basin Wide
Planning Strategy.
Cc: Central Files
C
rC�Files (mb)
Location: 225 Green Street, Suite 714, Fayetteville, North Carolina 28301
Phone: 910-433-3300 \ FAX: 910-486-0707 \ Customer Service: 1-877-623-6748
Internet: www.ncwaterqualitv.orq
An Equal Opportunity Employer
Nne
orthCarolina
Naturally
Aria
NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Beverly Eaves Perdue Coleen H. Sullins Dee Freeman .
Governor Director Secretary
July 20, 2011
Gerald Darden, Mayor
Town of Newton Grove
P.O. Box 4
-.------------ � Newton Grove, Grove, NC 28366
SUBJECT: June 19, 2011 Compliance Evaluation Inspection
Town of Newton Grove -
Newton Grove WWTP
Permit No: NC0072877
Sampson County
Dear Mr. Darden:
Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on
June 19, 2011. The Compliance Evaluation Inspection was conducted by Mark Brantley, Environmental Chemist,
of the Fayetteville Regional Office. The cooperation of Mr. Jim Balance, facility ORC, was greatly appreciated.
The facility was found to be in Compliance with permit NC0072877. As a reminder, preservation of the Waters of
the State can only be achieved through consistent NPDES Permit compliance.
Comments
• Facility was clean and neat in appearance at the time of the inspection.
• Records and logbooks are well kept and maintained. January 2011 and April 2011 laboratory records were
compared to the monthly DMR's and all data appeared to be reported correctly. All parameters and
sampling appear to be performed as required by the facility's NPDES permit.
• The Fayetteville Regional Office understands that the town plans to paint the exposed metal surfaces at the
WWTP in the near future. Painting these items should protect them from rusting and prolong the life span
of these items. By painting these structures the town could avoid costly repairs in the future.
• On the day of the inspection the effluent was very clear and appeared to be free of any visible solids.
Location: 225 Green Street, Suite 714, Fayetteville, NC 28301
Phone (910) 433-3300\FAX: 910-486-0707\Customer Service: 1-877-623-6748
Internet: www.ncwaterquality.org
NorthCarolina
Naturally
An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper
Mr. Darden
Page 2
July 20, 2011
Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have
any questions, please call me at 910-433-3327.
Sincerely,
Mark Brantley
Environmental Specialist
Surface Water Protection Section
Fayetteville Regional Office
cc: James Edward Ballance, ORC
Central Files
Fayetteville Files
United States Environmental Protection Agency
E PA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection
1 I NI 2 1 51 31 NC0072877 1 11 121 11/06/19 1 17
Type Inspector Fac Type
181 CI 191 SI 201 11
Remarks
2111111111111111111111111111111111111_11111111111166
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
671 1 69. 701 31 711 NI 72 I N I "I I 174 751 -1 11 1 I I I''
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Newton Grove WWTP
Pork Chop Hill Rd
Newton Grove NC 28366
Entry Time/Date
09:30.AM 11/06/19
Permit Effective Date
07/02/01
Exit Time/Date
12:00 PM 11/06/19
Permit Expiration Date
12/01/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
James Edward Ballance/ORC/910-591-7871/
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number •
Contacted
Gerald Darden,PO Box 4 Newton Grove NC
28366/Mayor/910-5,94-0827/9105940827 No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement • ■ Operations & Maintenance • Records/Reports
Self -Monitoring Program • Sludge Handling Disposal • Facility Site Review
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
•
•
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Mark Brantley FRO WQ//910-433-3300 Ext.727/
t7= 0-1i
Signature of Management Q A Reviewer . Agency/Office/Phone and Fax Numbers Date Belinda S Henson 4.5e,L FRO WQ//910-433-3300 Ext.726/ { - a 1 - 11j
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page # 1
NPDES
31 NC0072877 111 121
yr/mo/day
11/06/19
17
Inspection Type
1810I
(cont.) 1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Comments
Facility was clean and neat in appearance at the time of the inspection.
Records and logbooks are well kept and maintained. January 2011 and April 2011 laboratory records were
compared to the monthly DMR's and all data appeared to be reported correctly. All parameters and
sampling appear to be performed as required by the facility's NPDES permit.
The Fayetteville Regional Office understands that the town plans to paint the exposed metal surfaces at the
WWTP in the near future. Painting these items should protect them from rusting and prolong the life span of
these items. By painting these structures the town could avoid costly repairs in the future.
On the day of the inspection the effluent was very clear and appeared to be free of any visible solids.
Page # 2
Permit: NC0072877 Owner - Facility: Newton Grove WWTP
Inspection Date: 06/19/2011 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with' acceptable housekeeping? ■ n ❑ n
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge n n ❑ •
Judge, and other that are applicable?
Comment:
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new application? • n n n
Is the facility as described in the permit? ■ n n n
# Are there any special conditions for the permit? n n ■ ❑
Is access to the plant site restricted to the general public? ■ n n n
Is the inspector granted access to all areas for inspection? - ■ ❑ n
Comment:
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit? ■ n n ❑
Is all required information readily available, complete and current? - ■ ❑ n n
Are all records maintained for 3 years (lab. reg. required 5 years)? ■ n n n
Are analytical results consistent with data reported on DMRs? ■ n n n
Is the chain -of -custody complete? ■ n n n
Dates, times and location of sampling ■
Name of. individual performing the sampling ■
Results of analysis and calibration ■
Dates of analysis ■
Name of person performing analyses ■
Transported COCs ■
Are DMRs complete: do they include all permit parameters? ■ n n n
Has the facility submitted its annual compliance report to users and DWQ? ❑ n ❑ ■
(If thec:is =oa5Mrn permitted flow) Do they operate 4/7 with ^C2rtif 2d operator on each shift? nnmin
Is the ORC visitation log available and current? ■ n ❑ n
Is the ORC certified at grade equal to or higher than the facility classification? ■ n n ❑
Is the backup operator certified at one grade less or greater than the facility classification? ! n n n
Is a copy of the current NPDES permit available on site? ■ n n n
Page # 3
Permit: NC0072877 Owner - Facility: Newton Grove WWTP
Inspection Date: 06/19/2011 Inspection Type: Compliance Evaluation
Record Keeping Yes No NA NE
Facility has copy of previous year's Annual Report on file for review? ■ n ❑ n
Comment:
Flow Measurement - Effluent Yes No NA NE
# Is flow meter used for reporting? ■ n n n
Is flow meter calibrated annually? • n n n
Is the flow meter operational? • n n n
(If units are separated) Does the chart recorder match the flow meter? n ❑. ■ ❑
Comment:
Aerobic Digester Yes No NA NE
Is the capacity adequate? • •❑ ❑ n
Is the mixing adequate? • n 0 ❑
Is the site free of excessive foaming in the tank? ■ ❑ n n
# Is the odor acceptable? • n ❑ n
# Is tankage available for properly waste sludge? . • n n n
Comment:
Bar Screens Yes No NA NE
Type of bar screen
a.Manual U
b.Mechanical El
Are the bars adequately screening debris? • ❑ n ❑
Is the screen free of excessive debris? • n n n
Is disposal of screening in compliance? • n n n
Is the unit in good condition? • 0 0 0
Comment:
Equalization Basins Yes No NA NE
is the basin aerated?
Is the basin free of bypass lines or structures to the natural environment? ■ n n n
Is the basin free of excessive grease? ■ n n n
Are all pumps present? ■ n n n
Are all pumps operable? ■ n Q ❑
Page # 4
Permit: NC0072877 Owner - Facility: Newton Grove WWTP
Inspection Date: 06/19/2011 Inspection Type: Compliance Evaluation
Equalization Basins
Are float controls operable?
Are audible and visual alarms operable?
# Is basin size/volume adequate?
Comment:
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately '/4 of the sidewall depth)
Comment:
Oxidation Ditches
Are the aerators operational?
Are the aerators free of excessive solids build up?
# Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin's surface?
Is the DO level acceptable?
Are settleometer results acceptable (> 30 minutes)?
Is the DO level acceptable?(1.0 to 3.0 mg/I)
Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes)
Comment:
Disinfection - UV
Are extra UV bulbs available on site?
Are UV bulbs clean?
Yes No NA NE
nn■n
n n■n
■ nn.n
Yes No NA NE
• nnn
■nnn
■ nnn
■ nnn
• nnn
■ nnn
■ nnn
■ nnn
■ nnn
■ nnn
■ nnn.
Yes No NA NE
■ nnn
■ nnn
■ nnn
■ nnn
■ nnil
n nn■
■ nnn
n nn■
Yes No NA NE
■ nnn
■ nnn
Page # 5
Permit: NC0072877 Owner - Facility: Newton Grove WWTP
Inspection Date: 06/19/2011
Inspection Type: Compliance Evaluation
Disinfection - UV
Is UV intensity adequate?
Is transmittance at or above designed level?
Is there a backup system on site?
Is effluent dear and free of solids?
Comment:
Standby Power
Is automatically activated standby power available?
Is the generator tested by interrupting primary power source?
Is the generator tested under load?
Was generator tested & operational during the inspection?
Do the generator(s) have adequate capacity to operate the entire wastewater site?
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
Is the generator fuel level monitored?
Comment:
Pumps-RAS-WAS
Are pumps in place?
Are pumps operational?
Are there adequate spare parts and supplies on site?
Comment:
Influent Sampling
# Is composite sampling flow proportional?
Is sample collected above side streams?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)?
Is sampling performed according to the permit?
Comment:
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Yes No NA NE
■ nnn
■ nnn
n n■n
■ nnn
Yes No NA NE
■ nnn
■ nnn
■ nnn
n n■n
■ nnn
n nn■
■ nnn
Yes No NA NE
■ nnn
■ nnn
n nn■
Yes No NA NE
n n■n
■ nnn
■ nnn
■nnn
■ nnn
■ nnn
Yes No NA NE
n n®n
■ nnn
Paae # 6
Permit: NC0072877 Owner - Facility: Newton Grove WWTP
Inspection Date: 06/19/2011
Inspection Type: Compliance Evaluation
Effluent Sampling Yes No NA NE
Is proper volume collected? o n n n
Is the tubing clean? • n n n
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? sin n n
Is the facility sampling performed as required by the permit (frequency, sampling type representative)? ■ n n n
Comment:
Upstream / Downstream Sampling Yes No NA NE
Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? ■ Linn
Comment:
Filtration (High Rate Tertiary) Yes No NA NE
Type of operation:
Is the filter media present? • n n n
Is the filter surface free of clogging? ■ n ❑ n
Is the filter free of growth? ■ n n n
Is the air scour operational? ■ n n n
Is the scouring acceptable? i• n n n
Is the clear well free of excessive solids and filter media? ■ n n n
Comment: