Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCC214881_Site Plan or Location Map_20210830
PROJECT INFO. FACILITY NAME: MISSION BEHAVIORAL HEALTH HOSPITAL PROJECT DESCRIPTION: HCA PROJECT NUMBER: 2761000003 AHJ PROJECT NUMBERS: CON NUMBER: TBD ARCHITECT PROJECT NUMBER: 20034.00 OWNER CONTACTS HCA TEAM CONTACTS DESIGN MANAGER: Ryan Rohe CONSTRUCTION MANAGER: Eddie Puckett ONE PARK PLAZA, P.O. BOX 550 BUILDING II, 3RD FLOOR EAST NASHVILLE, TN 37203 T:615.344.2733 PROJECT CONTACTS DESIGN TEAM CONTACTS ARCHITECT & INTERIOR DESIGN ESA ARCHITECTS, P.C. 1033 DEMONBREUN STREET SUITE 800 NASHVILLE, TENNESSEE 37203 T. 615.329.9445 CIVIL ENGINEER CRUNK ENGINEERING LLC 7112 CROSSROADS BLVD, SUITE 201 BRENTWOOD, TN 37027 T. 615.873.1795 STRUCTURAL ENGINNER STRUCTURAL DESIGN GROUP 220 GREAT CIRCLE RD, SUITE 106 NASHVILLE, TN 37228 T. 615.255.5537 MECH & PLUMB ENGINEER I.C. THOMASSON ASSOCIATES, INC 2950 KRAFT DR, SUITE 500 NASHVILLE, TN 37204 T.615.346.3400 ELEC & TELECOMM ENGINEER I.C. THOMASSON ASSOCIATES, INC 2950 KRAFT DR, SUITE 500 NASHVILLE, TN 37204 T.615.346.3400 9657-27-2766 EDBAR LLC D.B. 3906, P. 727 P.B. 114, P. 33 ZONING: Cl USE: WAREHOUSE PORTION OF SUBJECT PROPERTY IN ZONE AE (HATCHED) SEE NOTE 3 /ZO / 2 1 I 9657-37-2616 I I CRAYTON HOLDINGS LLC W I D.B. 4747, P. 1979 co I I P B 112 P 171 -TRACT 2 Lu ZONING: Cl USE: COMMERCIAL LIB ola CIS Of I Lu WIC i \ • WITH 1/2" REBAR I I , / / 0.3' AG :3 I � � / 01 Z � o ZI cq w m 1 CONCRETE , S 70°29'18" E \16�\//� ' I/HEADWALL ,�44.0 38.57' °59p,2 / NJ 1 % ANNUAL CHANCE ` I WO FLOOD LINE NI O OO r I\ RBC "L-2058" - 0.2' AG N.C. GRID NAD83(2011) COORDINATES 1 N:677,248.61', E:952,870.30' SEDIMENT BASIN SHALL BE\ CONVERTED INTO THE PERMANENT WET POND UPON FINAL STABILIZATION OF THE SITE. \ 9657-27-7095 HOPEMONT ASSOCIATES LLC D.B. 2657, P. 428 ZONING: Cl USE: MANUFACTURING 03. O o �O \\\ \\ 301 \\ 30' INGRESS/EGRESS \ RIGHT-OF-WAY D.B. 4664, P. 1499 D.B. 1443, P. 393 POINT OF BEGINNING \ 6"X6" CONCRETE RIGHT-OF-WAY MONUMENT 1.0' AG N.C. GRID NAD83(2011) COORDINATES N:676,766.93', E:953,029.10' i i P N� 009�6 ONO \AOpNG�F �OS�G GON41 �N GPI ��� OF � NOS \400 �T SSMH RIM: 2,049.03' INV: 2,038.9' 8" DIP rn n v Z �� SITE O OG �a INTERSTATE 40 N a 7 VICINTIY MAP 1000, gWEETEN CREEK \ NAMED TRIBUTARY TO j�/_�`�N 88°40'23" E 374.31' (TOTAL) UN 9657-37-7941 OAKLEY BAPTIST CHURCH \ D.B. 589, P. 149 P.B. 2, P. 31 \ ZONING: RS-8 \ \ USE: CEMETERY INV: 2,052.6' INV:2,053.4' \ S 50021'14" E 5.14' 7�7GRAVE ,065.5' CONRET ALL 11j (l TW: 2076.00 B __169.00 FFF ��RTM - pR� MA�� 44s pNl F�T��RiyT,�#�) E op 8y993�gy 6 Construction Sequence The construction sequence on projects shall include the following essential criteria or equivalent sequence in the priority shown below: 1. Submit plans for review; 2. Obtain grading permit (includes preconstruction conference); 3. Submit four (4) copies of stormwater component shop drawings at or prior to the preconstruction meeting and receive approval by the City of Asheville prior to ordering materials. 4. Install all erosion control measures as shown; 5. On -site inspection by Inspector to approve perimeter erosion control devices; 6. Proceed with grading; 7. Clean sediment basins when one-half full; 8. Repair or replace all erosion control measures as needed; 9. Seed and mulch denuded area, as required, after finished grades are established; 10. Maintain soil erosion control measures until permanent ground cover established; \ 1 1. Request final approval by Construction Inspector; and, \ 12. Remove all temporary soil erosion control measures and stabilize these areas LOT 4 0/ _ \�0 ` O 110 sM� -o LOT3 517 9 G) E4 �\ er O0. 18) \ E4 (TY�i ) \\ > > Xx \\ \ \ \\\ N \\\ �(5\° E4 o 0 \\ \ O \\ 0 \ II 0.2'A � \ 111 J IIII 111 I U' 9657-47-0064 �I IIIIII \ IIII III I I o l AMARX CONSTRUCTION, LLC r IIIIII II o / D.B. 5522, P. 969 1i \I IIII I \ IIIII IIIII I I o P.B. 195, P. 17 - II III III m ZONING. RS-8 v IIIII IIIIII USE: RESIDENTIAL II I IIIIII 711± SQ. FT. OVERLAP I IIIII I I II WITH ADJOINING III II PROPERTY (HATCHED) 1IIIIIII II I IIIII IIIII o la \ SEE DETAIL III II II IIIIIIIII II q I __' _Pt "IE3 m \ I � III it INV: 2,092.1'11-' OL;TNETN RAILROAD, LLC II III SEA, c:) 9 II I II ° I N I I I O III II I II - � III IIIII rn �o I III I I1��-,0 II II 10 IIIIIIIco 11I IIII 111 i IIIII I III II II b I S 12048'46" W 1111 I I I I 7.03' 'l 111111 I II II co N I IIII II o II Illo / I IIIIII 1�� II.,II I UII / 0 m/ o m/ G� w >- co Er N W �a O teary 0 2 I ¢C)(J m I W 0 =AU) o co 01-w o Z } a LL O ¢C6Q LLLL 0 / omZ 1=�w I0 o ib co rn I � EROSION CONTROL PLAN KEYNOTES CODE DESCRIPTION DETAIL LOCATION 8TEMPORARY 8 CONSTRUCTION ENTRANCE C3.3 - 1 S CONCRETE WASHOUT AREA C3.3 - 2 E3 TEMPORARY SILT FENCE C3.3 -3 E4 TEMPORARY INLET PROTECTION C3.3 -4 E5 TEMPORARY TREE PROTECTION FENCE C3.3 -5 E6 RIPRAP OUTLET PROTECTION C3.3 - 6 E7 FAIRCLOTH SKIMMER C3.3 -7 E8 DIVERSION DITCH C3.3 - 8 8SEDIMENT 8 BASIN C3.3 - 9 E10 BAFFLE C3.3 - 10 G MODIFIED POND OUTLET STRUCTURE C3.3 - 12 E12 TEMPORARY CHECKDAM C3.3 - 13 NOTES: 1. REFER TO SHEET C2.0 FOR NOTES. 2. IF BORROWED OR WASTE FILL MATERIAL IS GENERATED, AN APPROVED GRADING PERMIT MUST BE SECURED FOR THE BORROW OR WASTE MATERIAL SITE PRIOR TO INITIATION OF ANY LAND DISTURBING ACTIVITY. 3. ALL FILL SLOPES SHALE BE COMPACTED FULL DEPTH TO NOT LESS THAN 95 PERCENT MAXIMUM DENSITY, SHALL BE PLACED ON A SURFACE CLEARED OF GROWTH AND DEBRIS, AND BE PROPERLY BENCHED AND DRAINED. 4. UNLESS A PERMIT FROM NCDEQ--DIVISION OF WASTE MANAGEMENT TO OPERATE A LANDFILL IS ON FILE FOR THE OFFICIAL SITE, ACCEPTABLE FILL MATERIAL SHALL BE FREE OF ORGANIC OR OTHER DEGRADABLE MATERIALS, MASONRY, CONCRETE AND BRICK IN SIZES EXCEEDING 12 INCHES, AND ANY MATERIALS WHICH WOULD CAUSE THE SITE TO BE REGULATED AS A LANDFILL BY THE STATE OF NORTH CAROLINA. 5. INDICATING ALL CONSTRUCTED SEVERE SLOPES GREATER THAN 2:1 SHALL BE DESIGNED BY A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER. ADDITIONALLY, FOR CONSTRUCTED SEVERE SLOPES GREATER THAN FIVE FEET IN HEIGHT, AN INSPECTION AND A STABILITY CERTIFICATE ARE REQUIRED BY A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER WITH GEOTECHNICAL EXPERTISE SUFFICIENT TO PERFORM THE INSPECTION AND STABILITY ANALYSIS. FOR ALL CONSTRUCTED SEVERE SLOPES WITHIN PROPOSED OR EXISTING PUBLIC RIGHTS -OF -WAY, PERIODIC INSPECTIONS AND COMPACTION REPORTS ARE REQUIRED BY A NORTH CAROLINA REGISTERED PROFESSIONAL ENGINEER WITH GEOTECHNICAL EXPERTISE PROPOSED EROSION & SEDIMENT CONTROL LEGEND TEMPORARY CONSTRUCTION ENTRANCE TP TEMPORARY TREE PROTECTION -SF TEMPORARY SILT FENCE TEMPORARY INLET PROTECTION TEMPORARY ROCK CHECK DAM -LOD LIMITS OF DISTURBANCE 9657-46-2546 SMITH DRAY LINE & STORAGE CO. D.B. 1371, P. 455 ZONING: Cl USE: WAREHOUSE 0 30 60 120 GRAPHIC SCALE SITE DATA TABLE OWNER/DEVELOPER: MISSION HEALTH 509 BILTMORE AVENUE ASHEVILLE, NC 28801 CIVIL ENGINEER: CRUNK ENGINEERING 7112 CROSSROADS BOULEVARD SUITE 201 BRENTWOOD, TN 37027 615-873-1795 SURVEYOR: ED HOLMES & ASSOCIATES, P.A. 300 RIDGEFIELD COURT #301 ASHEVILLE, NC 28806 ARCHITECT: ESA ARCHITECTS, P.C. 1033 DEMONBREUN STREET, SUITE 800 NASHVILLE, TN 37203 615-329-9445 PROJECT DATA PIN: 9657-37-3093 ADDRESS: CRAYTON ROAD DEED BOOK/PAGE: 2017/047 SITE ACREAGE: 25.60 AC. DISTURBED AREA 15 AC EXISTING ZONING: HB - HIGHWAY BUSINESS SURROUNDING ZONING: Cl- COMMERCIAL INDUSTRIAL AND RS8- HIGH DENSITY SINGLE- FAMILY PROPOSED USE: HEALTHCARE SOIL TYPE: TmC, Ud, UhE SOIL GROUP: B, C, A BUILDING SETBACKS: FRONT = 35 FT (5' PEDESTRIAN ORIENTATION) SIDE = N/A REAR = 10 FT CORNER = 25 FT BUILDING DATA: BUILDING DESCRIPTION: BEHAVIORAL HEALTH HOSPITAL PROPOSED HEIGHT: 27' 1 " FLOOR: 1 FLOOR GFA: 81750 SF IMPERVIOUS CALCULATIONS: IMPERVIOUS PERVIOUS PRE -DEVELOPMENT: 1.07 ACRES (0.4%) 24.53 ACRES (96%) POST- DEVELOPMENT: 5.20 ACRES (20%) 20.4 ACRES (80%) REQUIRED PARKING = 1 PER 2 EMPLOYEES & 1 PER 2 BEDS EMPLOYEES: 150 BEDS: 120 SPACES REQUIRED: 135 PROVIDED PARKING: REGULAR SPACES = 200 A.D.A SPACES = 8 TOTAL SPACES = 208 CUT AND FILL VOLUMES: CUT: 35249 CU-YD FILL: 41396 CU-YD NET: 6147 CU-YD (FILL) 0 r Z iY W W Z C7 CRUNK W 7112 CROSSROADS BOULEVARD SUITE 201 BRENTWOOD, TN 37027 (615) 873-1795 WWW.CRUNKENG.COM This drawing and the design shown is the property of the architect. The reproduction, copying or use of this drawing without their written consent is prohibited and any infringement will be subject to legal action. © ESa Architects, P.C. 2019 Seals (N CAROB//// `�QQE % OF 5 S p��2i,'� � SE L 41 6�16.•' •N I NE.• fir\ O/q 1/ LItttc'?- FIRM LICENSE: P-1417 a N O x x J Q UJ 2 J Q Q 2 UJ m Z O N �� DOCUMENT CHANGES Description Date Issue Description CITY RESUBMITTAL Original Issue Date 2021.06.16 HCA Project No 2761000003 Project No 20034.00 Drawn By BER Checked By ARH Drawing Title FINAL EROSION & SEDIMENT CONTROL PLAN Sheet Number C12 GRAPHIC SCALE: 1" = 1'-0" GRAPHIC SCALE: 3/4" = 1'-0" GRAPHIC SCALE: 1/2" = 1'-0" GRAPHIC SCALE: 3/8" = 1'-0" GRAPHIC SCALE: 1/4" = 1'-0" GRAPHIC SCALE: 3/16" = 1'-0" GRAPHIC SCALE: 1 /8" = 1'-0" GRAPHIC SCALE: 3/32" = 1'-0" GRAPHIC SCALE: 1/16" = 1'-0" GRAPHIC SCALE: 1/32" = 1'-0"