Loading...
HomeMy WebLinkAboutWQ0014391_Final Permit_20210824 August 24, 2021 G RIFF B URK M ANAGER B UILDERS F IRST S OURCE R ALEIGH, LLC 23 R ED C EDAR W AY A PEX, N ORTH C AROLINA 27523 Subject: Permit No. WQ0014391 Builders FirstSource Apex Yard WWTF Wastewater Irrigation System Chatham County Dear Mr. Burk: In accordance with your permit renewal request received May 27, 2021, we are forwarding herewith Permit No. WQ0014391 dated August 24, 2021, to Builders FirstSource Raleigh, LLC for the continued operation of the subject wastewater treatment and irrigation facilities. Please note that this renewed permit shall become effective on November 1, 2021 (i.e., the day after the expiration date of the existing permit). This permit shall be effective from November 1, 2021 through January 31, 2028, shall void Permit No. WQ0014391 issued November 2, 2016, and shall be subject to the conditions and limitations therein. The Permittee shall submit a renewal application no later than August 4, 2027. Please pay attention to the monitoring requirements listed Attachment A for they may differ from the previous permit issuance. Failure to establish an adequate system for collecting and maintaining the required operational information shall result in future compliance problems. The Division has removed the following permit condition since the last permit issuance dated November 2, 2016: Old Condition I.1. This condition has been satisfied. Old Condition I.2. This condition requirement has been removed. Old Condition VI.2. This condition has been removed because the permit is not voidable. Mr. Griff Burk August 24, 2021 Page 2 of 2 The following permit conditions are new since the last permit issuance dated November 2, 2016: Condition I.1. This condition requires the Permittee to submit a new lease agreement or an extension for the current agreement between Goldston Apex Properties, LLC and Builders FirstSource Raleigh, LLC. Condition III.16. The Permittee is required to test and calibrate metering equipment annually. Condition VI.10. This permit shall not be renewed if the Permittee or any affiliation has not paid the required annual fee. If any parts, requirements, or limitations contained in this permit are unacceptable, the Permittee has the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request shall be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings at 6714 Mail Service Center, Raleigh, NC 27699-6714. Otherwise, this permit shall be final and binding. If you need additional information concerning this permit, please contact Poorva Mokashi at (919) 707-3661 or poorva.mokashi@ncdenr.gov. Sincerely, S. Daniel Smith, Director Division of Water Resources cc: Chatham County Health Department (Electronic Copy) Raleigh Regional Office, Water Quality Regional Operations Section (Electronic Copy) Steve Reid Protection and Enforcement Branch (Electronic Copy) Laserfiche File (Electronic Copy) Digital Permit Archive (Electronic Copy) NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY RALEIGH WASTEWATER IRRIGATION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Builders FirstSource Raleigh, LLC Chatham County FOR THE continued operation of a 3,750 gallon per day (GPD) (150 employees at 25 GPD for five days) wastewater treatment and irrigation facility consisting of: a 3,000 gallon septic tank and a 2,000 gallon septic tank with an effluent filter; a 3,000 gallon pump tank; a 3,000 gallon dosing tank with two 29 GPM pumps; four EZ Treat Model 1200 recirculating media filter pods; an ultraviolet (UV) disinfection unit; a 299,000 gallon synthetically-lined storage pond; an irrigation pump station with two 31 GPM pumps and an effluent flow meter; a 3.6 acre drip irrigation area consisting of eight zones (i.e., Zones 01-1A through 01-4B and Zones 02-01A through 02-04B); and all associated piping, valves, controls and appurtenances to serve the Builders FirstSource Apex Yard WWTF, with no discharge of wastes to surface waters, pursuant to the application received May 27, 2021, and in conformity with the Division-approved plans and specifications considered a part of this permit. This permit shall be effective from November 1, 2021 through January 31, 2028, shall void Permit No. WQ0014391 issued November 2, 2016, and shall be subject to the following conditions and limitations: I. SCHEDULES 1. Prior to July 31, 2025, the Permittee shall provide a new lease agreement or an extension of the existing lease agreement with Goldston Apex Properties, LLC. The current lease agreement allows the Permittee to operate and maintain wastewater collection, treatment, conveyance, and irrigation system on the land owned by Goldston Apex Properties, LLC. This lease expires July 31, 2025. The Permittee shall submit a new agreement or an extension to the Division of Water Resources, Non-Discharge Branch, 1617 Mail Service Center, Raleigh, NC 27699-1617, or Non-Discharge.Reports@ncdenr.gov. \[15A NCAC 02T .0108(b)(1)(B)\] 2. A gauge to monitor waste levels in the 299,000 gallon synthetically-lined storage pond shall be installed within 60 days of the effective date of this permit. Caution shall be taken not to damage the integrity of any liner (if present) when installing a gauge. \[15A NCAC 02T .0108(b)(1)(B), 02T .0505(d)\] 3. The Permittee shall request renewal of this permit on Division-approved forms no later than August 4, 2027. \[15A NCAC 02T .0105(b), 02T .0109\] WQ0014391 Version 5.0 Shell Version 200201 Page 1 of 9 II. PERFORMANCE STANDARDS 1. The Permittee shall maintain and operate the subject non-discharge facilities so there is no discharge to surface waters, nor any contravention of groundwater or surface water standards. In the event the facilities fail to perform satisfactorily, including the creation of nuisance conditions due to improper operation and maintenance, or failure of the irrigation areas to assimilate the effluent, the Permittee shall take immediate corrective actions, including Division required actions, such as the construction of additional or replacement wastewater treatment or disposal facilities. \[15A NCAC 02T .0108(b)(1)(A)\] 2. This permit shall not relieve the Permittee of their responsibility for damages to groundwater or surface water resulting from the operation of this facility. \[15A NCAC 02T .0108(b)(1)(A)\] 3. Effluent quality shall not exceed the limitations specified in Attachment A \[15A NCAC 02T .0505(b)\] 4. Application rates, whether hydraulic, nutrient, or other pollutant, shall not exceed those specified in Attachment B. \[15A NCAC 02T .0505(c), 02T .0505(n)\] 5. The Permittee shall connect the irrigation system to a rain or moisture sensor designed to prevent irrigation during precipitation events or wet conditions. \[15A NCAC 02T .0505(x)\] 6. This disposal system was individually permitted on or after December 30, 1983 and therefore the compliance boundary is established either 250 feet from the wastewater irrigation area, or 50 feet within the property boundary, whichever is closest to the wastewater irrigation area. Any exceedance of groundwater standards at or beyond the compliance boundary shall require corrective action. Division- approved relocation of the compliance boundary shall be noted in Attachment B. Multiple contiguous properties under common ownership and permitted for use as a disposal system shall be treated as a single property with regard to determination of a compliance boundary. \[15A NCAC 02L .0106(d)(2), 02L .0107(b), 02T .0105(h), G.S. 143-215.1(i), G.S. 143-215.1(k)\] 7. The review boundary is midway between the compliance boundary and the wastewater irrigation area. Any exceedance of groundwater standards at or beyond the review boundary shall require preventative action. \[15A NCAC 02L .0106(d)(1), 02L .0108\] 8. The Permittee shall apply for a permit modification to establish a new compliance boundary prior to any sale or transfer of property affecting a compliance boundary (i.e., parcel subdivision). \[15A NCAC 02L .0107(c)\] 9. No wells, excluding Division-approved monitoring wells, shall be constructed within the compliance boundary except as provided for in 15A NCAC 02L .0107(g). \[15A NCAC 02L .0107\] 10. Except as provided for in 15A NCAC 02L .0107(g), the Permittee shall ensure any landowner who is not the Permittee and owns land within the compliance boundary shall execute and file with the Chatham County Register of Deeds an easement running with the land containing the following items: a. A notice of the permit and number or other description as allowed in 15A NCAC 02L .0107(f)(1); b. Prohibits construction and operation of water supply wells within the compliance boundary; and c. Reserves the right of the Permittee or the State to enter the property within the compliance boundary for purposes related to the permit. The Director may terminate the easement when its purpose has been fulfilled or is no longer needed. \[15A NCAC 02L .0107(f)\] WQ0014391 Version 5.0 Shell Version 200201 Page 2 of 9 11. The facilities herein were permitted per the following setbacks: a. The irrigation sites, Fields 01-1A through 01-4B, were originally permitted December 10, 1997. The setbacks for drip irrigation sites originally permitted or modified from February 1, 1993 to August 31, 2006 are as follows (all distances in feet): i. Each private or public water supply source: 100 ii. Surface waters: 100 iii. Groundwater lowering ditches: 25 iv. Surface water diversions (upslope): 10 v. Surface water diversions (downslope): 25 vi. Each well with exception of monitoring wells: 100 1 vii. Each property line: 50 viii. Top of slope of embankments or cuts of two feet or more in vertical height: 15 ix. Each water line: 10 x. Each swimming pool: 100 xi. Public right of way: 50 xii. Nitrification field: 20 xiii. Each building foundation or basement: 15 1 Setbacks to property lines are not applicable when the Permittee, or the entity from which the Permittee is leasing, owns both parcels separated by the property line. \[15A NCAC 02H .0219(j)(5)\] b. The irrigation sites, Fields 02-1A through 02-4B, were originally permitted November 2, 2016. The setbacks for drip irrigation sites originally permitted or modified from September 1, 2006 to August 31, 2018 are as follows (all distances in feet): 1 i. Each habitable residence or place of assembly under separate ownership: 100 ii. Each habitable residence or place of assembly owned by the Permittee: 15 iii. Each private or public water supply source: 100 iv. Surface waters: 100 v. Groundwater lowering ditches: 100 vi. Surface water diversions: 25 vii. Each well with exception of monitoring wells: 100 2 viii. Each property line: 50 ix. Top of slope of embankments or cuts of two feet or more in vertical height: 15 x. Each water line: 10 xi. Subsurface groundwater lowering drainage systems: 100 xii. Each swimming pool: 100 xiii. Public right of way: 50 xiv. Nitrification field: 20 xv. Each building foundation or basement: 15 1 Habitable residences or places of assembly under separate ownership constructed after the facilities herein were originally permitted or subsequently modified are exempt from this setback. 2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the Permittee is leasing, owns both parcels separated by the property line. WQ0014391 Version 5.0 Shell Version 200201 Page 3 of 9 \[15A NCAC 02T .0506(a), 02T .0506(e), 02T .0506(f)\] c. The storage and treatment units comprising of the 3,000 gallon septic tank; the 2,000 gallon pump tank converted to a 2,000 gallon septic tank; the 299,000 gallon synthetically lined storage pond; and the irrigation pump station were originally permitted December 10, 1997. The setbacks for storage and treatment units originally permitted or modified from February 1, 1993 to August 31, 2006 are as follows (all distances in feet): i. Each private or public water supply source: 100 ii. Surface waters: 50 iii. Each well with exception of monitoring wells: 100 1 iv. Each property line: 50 v. Nitrification field: 20 1 Setbacks to property lines are not applicable when the Permittee, or the entity from which the Permittee is leasing, owns both parcels separated by the property line. \[15A NCAC 02H .0219(j)(5)\] d. The storage and treatment units comprising of the 3,000 gallon pump tank; a 3,000 gallon dosing tank; four EZ Treat Model 1200 recirculating media filter pods; and an ultraviolet (UV) disinfection unit were originally permitted November 2, 2016. The setbacks for storage and treatment units originally permitted or modified from September 1, 2006 to August 31, 2018 are as follows (all distances in feet): 1 i. Each habitable residence or place of assembly under separate ownership: 100 ii. Each private or public water supply source: 100 iii. Surface waters: 50 iv. Each well with exception of monitoring wells: 100 2 v. Each property line: 50 1 Habitable residences or places of assembly under separate ownership constructed after the facilities herein were originally permitted or subsequently modified are exempt from this setback. 2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the Permittee is leasing, owns both parcels separated by the property line. \[15A NCAC 02T .0506(b), 02T .0506(e), 02T .0506(f)\] WQ0014391 Version 5.0 Shell Version 200201 Page 4 of 9 III. OPERATION AND MAINTENANCE REQUIREMENTS 1. The Permittee shall operate and maintain the subject facilities as a non-discharge system. \[15A NCAC 02T .0500\] 2. The Permittee shall maintain an Operation and Maintenance Plan, which shall include operational functions, maintenance schedules, safety measures, and a spill response plan. \[15A NCAC 02T .0507(a)\] 3. classification of the subject non-discharge facilities, the Permittee shall designate and employ a certified operator in responsible charge (ORC), and one or more certified operators as back-up ORCs. The ORC or their back-up shall operate and visit the facilities as required by the WPCSOCC. \[15A NCAC 02T .0117\] 4. The Permittee shall maintain vegetative cover on the irrigation sites, such that crop health is optimal, allows even effluent distribution, and allows inspection of the irrigation system. \[15A NCAC 02T .0507(b)\] 5. The Permittee shall take measures to prevent effluent ponding in or runoff from the irrigation sites listed in Attachment B. \[15A NCAC 02T .0507(c)\] 6. The Permittee shall not irrigate treated effluent during inclement weather, or when the soil is in a condition that will cause ponding or runoff. \[15A NCAC 02T .0505(x)\] 7. Irrigation equipment shall be tested and calibrated once per permit cycle. \[15A NCAC 02T .0507(d)\] 8. Only treated effluent from the Builders FirstSource Apex Yard WWTF shall be irrigated on the sites listed in Attachment B. \[15A NCAC 02T .0501\] 9. The Permittee shall not allow vehicles or heavy machinery on the irrigation area, except during equipment installation or maintenance activities. \[15A NCAC 02T .0507(e)\] 10. The Permittee shall prohibit public access to the wastewater treatment, storage, and irrigation facilities. \[15A NCAC 02T .0505(q)\] 11. The Permittee shall dispose or utilize generated residuals in a Division-approved manner. \[15A NCAC 02T .0508, 02T .1100\]. 12. The Permittee shall not divert or bypass untreated or partially treated wastewater from the subject facilities. \[15A NCAC 02T .0505(j)\] 13. Freeboard in the 299,000 gallon synthetically-lined storage pond shall not be less than two feet at any time. \[15A NCAC 02T .0505(d)\] 14. A gauge to monitor waste levels in the 299,000 gallon synthetically-lined storage pond shall be provided. This gauge shall have readily visible permanent markings, at inch or tenth of a foot increments, indicating the following elevations: maximum liquid level at the top of the temporary liquid storage volume; minimum liquid level at the bottom of the temporary liquid storage volume; and the lowest point on top of the dam. \[15A NCAC 02T .0507(f)\] 15. A protective vegetative cover shall be established and maintained on all berms, pipe runs, erosion control areas, surface water diversions, and earthen embankments (i.e., outside toe of embankment to maximum allowable temporary storage elevation on the inside of the embankment). Trees, shrubs, and other woody vegetation shall not be allowed to grow on the earthen dikes or embankments. Earthen embankments shall be kept mowed or otherwise controlled and accessible. \[15A NCAC 02T .0507(g)\] WQ0014391 Version 5.0 Shell Version 200201 Page 5 of 9 16. Metering equipment shall be tested and calibrated annually. \[15A NCAC 02T .0507(d)\] IV. MONITORING AND REPORTING REQUIREMENTS 1. The Permittee shall conduct and report any Division required monitoring necessary to evaluate this groundwater and surface water. \[15A NCAC 02T .0108(c)\] 2. A Division-certified laboratory shall conduct all analyses for the required effluent, groundwater, and surface water parameters. \[15A NCAC 02H .0800\] 3. Flow through the treatment facility shall be continuously monitored, and daily flow values shall be reported on Form NDMR. Facilities with a permitted flow less than 10,000 GPD may estimate their flow from water usage records provided the water source is metered. \[15A NCAC 02T .0105(k), 02T .0108(c)\] 4. The Permittee shall monitor the treated effluent at the frequencies and locations for the parameters specified in Attachment A. \[15A NCAC 02T .0108(c)\] 5. The Permittee shall maintain records tracking the amount of effluent irrigated. These records shall include the following information for each irrigation site listed in Attachment B: a. Date of irrigation; b. Volume of effluent irrigated; c. Site irrigated; d. Length of time site is irrigated; e. Continuous weekly, monthly, and year-to-date hydraulic (inches/acre) loadings; f. Continuous monthly and year-to-date loadings for any non-hydraulic parameter specifically limited in Attachment B; g. Weather conditions; and h. Maintenance of cover crops. \[15A NCAC 02T .0108(c)\] 6. Freeboard (i.e., waste level to the lowest embankment elevation) in the 299,000 gallon synthetically- lined storage pond shall be measured to the nearest inch or tenth of a foot, and recorded weekly. Weekly freeboard records shall be maintained for five years, and shall be made available to the Division upon request. \[15A NCAC 02T .0108(c)\] 7. Three copies of all monitoring data (as specified in Conditions IV.3. and IV.4.) on Form NDMR for each PPI, and three copies of all operation and disposal records (as specified in Conditions IV.5. and IV.6) on Form NDAR-1 for every site in Attachment B shall be submitted on or before the last day of the following month. If no activities occurred during the monitoring month, monitoring reports are still required documenting the absence of the activity. All information shall be submitted to the following address: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 \[15A NCAC 02T .0105(l)\] WQ0014391 Version 5.0 Shell Version 200201 Page 6 of 9 8. The Permittee shall maintain a record of all residuals removed from this facility. This record shall be maintained for five years, and shall be made available to the Division upon request. This record shall include: a. Name of the residuals hauler; b. Non-Discharge permit number authorizing the residuals disposal, or a letter from a municipality agreeing to accept the residuals; c. Date the residuals were hauled; and d. Volume of residuals removed. \[15A NCAC 02T .0508(b)\] 9. A maintenance log shall be kept at this facility. This log shall be maintained for five years, and shall be made available to the Division upon request. This log shall include: a. Date of flow measurement device calibration; b. Date of irrigation equipment calibration; c. Visual observations of the plant and plant site; and d. Record of preventative maintenance (e.g., changing of equipment, adjustments, testing, inspections and cleanings, etc.). \[15A NCAC 02T .0507(h)\] 10. An annual representative soils analysis (i.e., Standard Soil Fertility Analysis) shall be conducted on each irrigation site listed in Attachment B. These results shall be maintained at the facility for five years, and shall be made available to the Division upon request. Each Standard Soil Fertility Analysis shall include the following parameters: Acidity Exchangeable Sodium Percentage Phosphorus Base Saturation (by calculation) Magnesium Potassium Calcium Manganese Sodium Cation Exchange Capacity Percent Humic Matter Zinc Copper pH \[15A NCAC 02T .0108(c)\] 11. Noncompliance Notification: The Permittee shall report to the Raleigh Regional Office, telephone number (919) 791-4200, within 24 hours of first knowledge of the following: a. Treatment of wastes abnormal in quantity or characteristic, including the known passage of a hazardous substance. b. Any process unit failure (e.g., mechanical, electrical, etc.) rendering the facility incapable of adequate wastewater treatment. c. Any facility failure resulting in a discharge to surface waters. d. Any time self-monitoring indicates the facility has gone out of compliance with its permit limitations. e. Ponding in or runoff from the irrigation sites. Emergencies requiring reporting outside normal business hours shall call Response personnel at telephone number (800) 662-7956, (800) 858-0368, or (919) 733-3300. All noncompliance notifications shall file a written report to the Raleigh Regional Office within five days of first knowledge of the occurrence, and this report shall outline the actions proposed or taken to ensure the problem does not recur. \[15A NCAC 02T .0108(b)(1)(A)\] WQ0014391 Version 5.0 Shell Version 200201 Page 7 of 9 V. INSPECTIONS 1. The Permittee shall perform inspections and maintenance to ensure proper operation of the wastewater treatment and irrigation facilities. \[15A NCAC 02T .0507(i)\] 2. The Permittee shall inspect the wastewater treatment and irrigation facilities to prevent malfunctions, facility deterioration, and operator errors that may result in discharges of wastes to the environment, threats to human health, or public nuisances. The Permittee shall maintain an inspection log that includes the date and time of inspection, observations made, and maintenance, repairs, or corrective actions taken. The Permittee shall maintain this inspection log for a period of five years from the date of the inspection, and this log shall be made available to the Division upon request. \[15A NCAC 02T .0507(h), 02T .0507(i)\] 3. Division authorized representatives may, upon presentation of credentials, enter and inspect any property, premises, or place related to the wastewater treatment and irrigation facilities permitted herein at any reasonable time for determining compliance with this permit. Division authorized representatives may inspect or copy records maintained under the terms and conditions of this permit, and may collect groundwater, surface water, or leachate samples. \[G.S. 143-215.3(a)(2)\] VI. GENERAL CONDITIONS 1. Failure to comply with the conditions and limitations contained herein may subject the Permittee to a Division enforcement action. \[G.S. 143-215.6A, 143-215.6B, 143-215.6C\] 2. This permit is effective only with respect to the nature and volume of wastes described in the permit application, and Division-approved plans and specifications. \[G.S. 143-215.1(d)\] 3. Unless specifically requested and approved in this permit, there are no variances to administrative codes or general statutes governing the construction or operation of the facilities permitted herein. \[15A NCAC 02T .0105(n)\] 4. The issuance of this permit does not exempt the Permittee from complying with all statutes, rules, regulations, or ordinances that other jurisdictional government agencies (e.g., local, state, and federal) may require. \[15A NCAC 02T .0105(c)(6)\] 5. If the permitted facilities change ownership, or the Permittee changes their name, the Permittee shall submit a permit modification request on Division-approved forms. The Permittee shall comply with all terms and conditions of this permit until the permit is transferred to the successor-owner. \[G.S. 143- 215.1(d3)\] 6. The Permittee shall retain a set of Division-approved plans and specifications for the life of the facilities permitted herein. \[15A NCAC 02T .0105(o)\] 7. The Permittee shall maintain this permit until the proper closure of all facilities permitted herein, or until the facilities permitted herein are permitted by another authority. \[15A NCAC 02T .0105(j)\] WQ0014391 Version 5.0 Shell Version 200201 Page 8 of 9 8. This permit is subject to revocation or modification upon 60-day notice from the Division Director, in whole or part for: a. violation of any terms or conditions of this permit or Administrative Code Title 15A Subchapter 02T; b. obtaining a permit by misrepresentation or failure to disclose all relevant facts; c. i. to enter the where a system is located or where any records are required to be kept; ii. to have access to any permit required documents and records; iii. to inspect any monitoring equipment or method as required in this permit; or iv. to sample any pollutants; d. ee for administering and compliance monitoring; or e. a Division determination that the conditions of this permit are in conflict with North Carolina Administrative Code or General Statutes. \[15A NCAC 02T .0110\] 9. Unless the Division Director grants a variance, expansion of the facilities permitted herein shall not occur if any of the following apply: a. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has been convicted of environmental crimes under G.S. 143-215.6B, or under Federal law that would otherwise be prosecuted under G.S. 143-215.6B, and all appeals of this conviction have been abandoned or exhausted. b. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has previously abandoned a wastewater treatment facility without properly closing the facility. c. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid a civil penalty, and all appeals of this penalty have been abandoned or exhausted. d. The Permittee or any parent, subsidiary, or other affiliate of the Permittee is currently not compliant with any compliance schedule in a permit, settlement agreement, or order. e. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid an annual fee. \[15A NCAC 02T .0120(b), 02T .0120(d)\] 10. This permit shall not be renewed if the Permittee or any affiliation has not paid the required annual fee. \[15A NCAC 02T .0120(c)\] th Permit issued this the 24 day of August 2021 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION ____________________________________________ S. Daniel Smith, Director Division of Water Resources By Authority of the Environmental Management Commission Permit Number WQ0014391 WQ0014391 Version 5.0 Shell Version 200201 Page 9 of 9 THIS PAGE BLANK 1 5.0 of 1 Page GrabGrabGrabGrabGrabGrabGrabGrabGrab Type Version: Sample Estimate 11111111 14391 Weekly Monthly 3 x Year 3 x Year 3 x Year 3 x Year 3 x Year 3 x Year 3 x Year 3 x Year Frequency MONITORING REQUIREMENTS Measurement Number: WQ00 Daily Maximum Permit Daily Minimum 200 Monthly Geometric Mean EFFLUENT LIMITS Attachment A 2 301530 750 , 3 . Average Monthly . su GPD mg/Lmg/Lmg/Lmg/Lmg/Lmg/Lmg/L Units of Measure #/100 mL and November , March, July n i FC Broth, 44.5 ºC - LIMITATIONS AND MONITORING REQUIREMENTS Parameter Description Day (20 ºC) - WWTF Effluent BOD, 5Coliform, Fecal MF, MFlow, in Conduit or thru Treatment PlantNitrogen, Ammonia Total (as N)Nitrogen, Kjeldahl, Total (as N)Nitrogen, Nitrate Total (as N)Nitrogen, Total (as N)pHPhosphorus, Total (as P)Solids, Total Suspended ear sampling shall be conducted EFFLUENT CHARACTERISTICS Y 002 3 x The average daily flow of 3,750 GPD is based upon a five day work week PCS Code PI 00310316165005000610006250062000600004000066500530 ATTACHMENT A P 1.2.WQ0014391 Version 4.0 THIS PAGE BLANK 1 nches Units inchesinchesinchesinchesinchesinchesiinchesinchesinchesinchesinchesinchesinchesinchesinches 5.0 of 1 Max 22.4822.4822.4822.4822.4822.4822.4822.4818.1118.1118.1118.1118.1118.1118.1118.11 Yearly Page Version: 0.40.40.40.40.40.40.40.40.20.20.20.20.20.20.20.2 Rate Hourly 14391 APPLICATION LIMITATIONS Parameter Discharge Application RateDischarge Application RateDischarge Application RateDischarge Application RateDischarge Application RateDischarge Application RateDischarge Application RateDischarge Application RateDischarge Application RateDischarge Application RateDischarge Application RateDischarge Application RateDischarge Application RateDischarge Application RateDischarge Application RateDischarge Application Rate ---------------- NonNonNonNonNonNonNonNonNonNonNonNonNonNonNonNon Number: WQ00 012840128401284012840128401284012840128401284 01284 01284 01284 01284 01284 01284 01284 Permit PolktonPolktonPolktonPolktonPolktonPolktonPolktonPolktonPolktonPolktonPolktonPolktonPolktonPolktonPolktonPolkton ---------------- Dominant Soil Series White StoreWhite StoreWhite StoreWhite StoreWhite StoreWhite StoreWhite StoreWhite StoreWhite StoreWhite StoreWhite StoreWhite StoreWhite StoreWhite StoreWhite StoreWhite Store complex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopescomplex, 2 to 6% slopes WhB WhB WhB WhB WhB WhB WhB WhB WhB WhB WhB WhB WhB WhB WhB WhB 6 . 3 Net 0.190.190.190.190.190.190.190.190.180.220.280.230.320.250.280.32 Attachment B Acreage °°°°°°°° 1313131313131313 Apex Yard WWTF 78.957578.957578.957578.957578.957578.957578.957578.957578.957463°78.957737°78.957187°78.957160°78.957460°78.957197°78.957764°78.957904° Longitude ---------------- °°°°°°°° 03090309090303 797 Latitude REA INFORMATION 35.738635.738435.738235.738135.738035.73735.737635.737435.739527°35.739517°35.739583°35.739139°35.738999°35.738757°35.738903°35.738699° County ChathamChathamChathamChathamChathamChathamChathamChathamChathamChathamChathamChathamChathamChathamChathamChatham Builders FirstSource IRRIGATION A Lessee Raleigh, LLCRaleigh, LLCRaleigh, LLCRaleigh, LLCRaleigh, LLCRaleigh, LLCRaleigh, LLCRaleigh, LLCRaleigh, LLCRaleigh, LLCRaleigh, LLCRaleigh, LLCRaleigh, LLCRaleigh, LLCRaleigh, LLCRaleigh, LLC Raleigh, LLC Builders FirstSourceBuilders FirstSource Builders FirstSource Builders FirstSource Builders FirstSource Builders FirstSource Builders FirstSource Builders FirstSource Builders FirstSource Builders FirstSource Builders FirstSource Builders FirstSource Builders FirstSource Builders FirstSource Builders FirstSource Builders FirstSource APPROVED LAND APPLICATION SITES AND LIMITATIONS Owner 91 Version 5.0 Goldston Apex Goldston Apex Goldston Apex Goldston Apex Goldston Apex Goldston Apex Goldston Apex Goldston Apex Goldston Apex Goldston Apex Goldston Apex Goldston Apex Goldston Apex Goldston Apex Goldston Apex Goldston Apex Properties, LLCProperties, LLCProperties, LLCProperties, LLCProperties, LLCProperties, LLCProperties, LLCProperties, LLCProperties, LLCProperties, LLCProperties, LLCProperties, LLCProperties, LLCProperties, LLCProperties, LLCProperties, LLC 1B2B3B4B1B2B3B4B 1A2A3A4A1A2A3A4A -------- -------- uilders FirstSource Field 0101010102020202 0101010102020202 Totals ATTACHMENT B B WQ00143 Deedibeat.-riciflolo ;)ro-vided t�y Chatharn County.] 31