Loading...
HomeMy WebLinkAboutNC0072877_Inspection_20090501ATA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary May 1, 2009 Gerald Darden,Mayor Town of Newton Grove PO Box 4 Newton Grove NC 28366 SUBJECT: April 28, 2009 Compliance Evaluation Inspection Town of Newton Grove Newton Grove WWTP Permit No: NC0072877 • Sampson County Dear Mr. Darden: Enclosed please find a copy of the Compliance Evaluation Inspection Report from the inspection conducted on April 28, 2009 by Hughie White of the Fayetteville Regional Office. Mr. Jim Ballance assisted with this inspection and his assistance was greatly appreciated. The facility was found to be in Compliance with permit NC0072877. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff has any questions, please call me at 910-433-3300. Sincerely, Hughie .White ' • Environmental Specialist • cc: James Ballance, ORC Central Files Fayetteville Files 225 Green St., Suite 7.14, Fayetteville, NC 28301-5043 Phone: 910-433-33001 FAX: 910-486-07071'Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity 1 Affirmative Action Employer NonrthCarolina 77aturaI`j • United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 I NI 2 15I 3I NC0072877 111 121 09/04/28 , 117 Type Inspector Fac Type 181 ci 191 SI 201 I Li 1 1 1 1 1 1 1 I 1 1 1 1 I l 166 Remarks 211 1 1 1 1 1 1 1.1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 169 70 I I •71 I I 721 NI 731 Li 1 174 761 1 1 1 1 I - I 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Newton Grove WWTP Pork Chop Hill Rd Newton Grove NC 28366 Entry Time/Date 12:00 PM 09/04/28 Permit Effective Date 07/02/01 Exit Time/Date 02:00 PM 09/04/28 Permit Expiration Date 12/01/31 Name(s) of.Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// 'James Edward Ballance/ORC/910-591-7871/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Gerald Darden,P0 Box 4 Newton Grove NC Contacted 28366/Mayor/910-594-0827/9105940827 No, Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports ■ Self -Monitoring Program Sludge Handling Disposal Facility Site Review • Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspectors) - Agency/Office/Phone and Fax Numbers Date Hughie White r�/' FRO WQ//910-433-3300 Ext.708/ /,,7 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date Belinda S Henson �Wi,fp FRO WQ//910-433-3300 Ext.726/ 5/41/b 9 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES yr/mo/day Inspection Type NC0072877 111 121 09/09/28 117 18id (cont.). 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) A copy of the permit was available for review. The previous years annual report was also available for ' review. The ORC visitation log appeared to be complete and current. Calibration records appeared to be complete. Laboratory data was reviewed and all data appeared to be correct as reported on the DMR's. The flow meter is being calibrated at six month intervals. All units appeared to be in good working condition. The plant appears to be operated and maintained properly -with very good housekeeping. The effluent was very clear and appeared to be free of any visible solids. Page # 2 Permit: NC0072877 Owner - Facility: Newton Grove VWVfP Inspection Date: 04/28/2009 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ n ❑ n Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? n n ■ n Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ ■ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ n n n Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? ■ n n n Are all records maintained for 3 years (lab. reg. required 5 years)? ■ n n ❑ Are analytical results consistent with data reported on DMRs? ■ n n n . Is the chain -of -custody complete? ■ ❑ ❑ ❑ Dates, times and location of sampling ❑ Name of individual performing the sampling ❑ Results of analysis and calibration ❑ Dates of analysis ❑ Name of person performing analyses ❑ Transported COCs ❑ Are DMRs complete: do they include all permit parameters? ■ n ❑ n Has the facility submitted its annual compliance report to users and DWQ? ■ n ❑ n (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? n n ■ n Is the ORC visitation log available and current? ■ ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? • n n n Is the backup operator certified at one grade less or greater than the facility classification? ■ ❑ n n Is a copy of the current NPDES permit available on site? ■ ❑ ❑ ❑ Page # Permit: NC0072877 Owner - Facility: Newton Grove V VVTP Inspection Date: 04/28/2009 Inspection Type: Compliance Evaluation. Record Keeping Facility has copy of previous year's Annual Report on file for review? Comment: Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Equalization Basins Is the basin aerated? • Is the basin free of bypass lines or structures to the natural environment? Is the basin free of excessive grease? Are all pumps present? Are all pumps operable? Are float controls operable? Are audible and visual alarms operable? # Is basin size/volume adequate?. Comment: Oxidation Ditches Are the aerators operational? Are the aerators free of excessive solids build up? .# Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Are settleometer results acceptable (> 30 minutes)? Is the DO level acceptable?(1.0 to 3.0 mg/I) Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes) Yes No NA NE ■ nnn Yes No NA NE ■ n ■ nnn ■ nnn. ■ nnn ■ n n n YesNo NA NE •nnn ■ nnn E n n n • n n n ■ nnn ■ nnn nnn■ ■ nnn Yes No NA NE ■ .nnn ■ nnn ■ n n n ■ n n n . nnn n nn ■ ■ n n n n nn■ Page # .4 Permit: NC0072877 Owner - Facility: Newton Grove WWTP Inspection Date: 04/28/2009 Inspection Type: Compliance Evaluation Oxidation Ditches Comment: Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow dear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately '/d of the sidewall depth) Comment: Aerobic Digester Is the capacity adequate? Is the mixing adequate? Is the site free of excessive foaming in the tank? # Is the odor acceptable? # Is tankage available for properly waste sludge? Comment: The wasted sludge is land applied (sprayed) on land adjacent to the VWVTP. Disinfection - UV Are extra UV bulbs available on site? Are UV bulbs clean? Is UV intensity adequate? Is transmittance at or above designed level? Is there a backup system on site? Is effluent clear and free of solids? Comment: Yes No NA NE Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nnn ■ nEln ■ nnn ■ nnn Yes No NA NE ■ nnn ■ nnn ■ nnn ■ nnn n n■n Yes No NA NE n nn■ ■ nnn ■ nnn n nn■ ■ nnn ■ nnn Page # 5 Permit: NC0072877 Owner - Facility: Newton Grove VWVfP Inspection Date: 04/28/2009 Inspection Type: Compliance Evaluation Standby Power Is automatically activated standbypower available? Is the generator tested by interrupting primary power source? Is the generator tested under load? - Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Comment: The generator was not tested during this inspection. Effluent Sampling Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? .Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: The sampler collects samples on time intervals not by flow rate. Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Yes No NA NE ■ nnn ■ nnn ■nnn o .—o 0 • .nnn ■ nnn ■ nnn Yes No NA NE. n■nn ■ nnn n nn■ ■ nn.n n n■n . ono Yes No NA NE ■ nnn •nnn n n■n Yes No NA NE ■ n n n ■ nnn ■ nnn. n n■n Page # 6