HomeMy WebLinkAboutNC0072877_Inspection_20140702ATA, NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Pat McCrory John E. Skvarla, III Governor - Secretary July 2, 2014 Gerald W Darden Town of Newton. Grove PO Box 4 Newton Grove NC 28366 SUBJECT: June 26, 2014 Compliance Evaluation Inspection Town of Newton Grove Newton Grove WWTP. Permit No: NC0072877 Sampson County Dear Mr. Darden : Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on June 26, 2014. The Compliance Evaluation Inspection was conducted by Trent Allen of the Fayetteville Regional Office. The facility was found to be in Compliance with permit NC0072877. Asa reminder, preservation of the Waters of the State can only be achieved through consistent NPDES Permit compliance. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 910-433-3322. Sincerely, Trent Allen Environmental Engineer Division of Water Resources Water Quality Regional Operations Section cc: James -Edward Ballance, ORC Central Files 7--Fayettevil Files ENCLOSURE: NPDES Permit NC0072877 Location: 225 Green Street, Suite 714, Fayetteville, NC .28301 Phone (910) 433-3300\FAX: 910-486-0707\Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org hhCaroliIla attiradi An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper United States Environmental Protection Agency E PA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction CodeNPDES yr/mo/day Inspection 1 InI l '5I 2 3 I NC0072877 111 12 1 14/06/26 117 Type 1812I I I I I I Inspector Fac Type 19 Li 201 211111 11 I I I I II I I I I I I I I I I I I I I I I I I II I I I I I p6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 • QA 67I I 70I I 71 I I 72 1LJ 1 Reserved 731 I 174 751 I I I r 1 1 1 1 1 18° Section B: Facility Data Name and Location of FacilityInspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Newton Grove WWTP Pork Chop Hill Rd Newton Grove NC 28366 Entry Time/Date 09:15AM 14/06/26 Permit Effective Date 12/09/01 Exit Time/Date 12:30PM 14/06/26 Permit Expiration Date 17/01/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// James Edward Ballance/ORC/910-591-7871/ Other Facility Data Name, Address of Responsible Official/fitle/Phone and Fax Number Contacted Gerald Darden,PO Box4 Newton Grove NC 28366/Mayor/910-594-0827/9105940827 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit � Flow Measurement Operations & Maintenanc6 Records/Reports Compliance Schedules Self -Monitoring Program . Sludge Handling Disposal • Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s`))of Inspector(s) Agency/Office/Phone and Fax Numbers Trent Allen #2.A/age FRO WQ//910-433-3300/ Date +1 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers , Date __3` 1 Li Belinda S Henson �1 FFFRO 1(j/Q//�,1 Q 43333-33-0000 Ext.72F 7-3- EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# 1 NODES yr/mo/day Inspection Type 31 NC0072877 I11 121 14/06/26 17 18 i , i 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The VVWTP was very clean and appeared to be well maintained. Bench sheets for the month of December 2013 were compared to the DMR and results appeared consistent. Flow meter was last calibrated on December 2013. Back-up generator is tested every Monday for 1 hour. Page# 2 Permit: NC0072877 Owner - Facility: Newton Grove WWrP Inspection Date: 06/26/2014 Inspection Type: Compliance Evaluation Compliance Schedules Yes No NA NE Is there a compliance schedule for this facility? 0 ❑ • 0 Is the facility compliant with the permit and conditions for the review period? ® 0 0 ❑ Comment: Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: pH,DO,Sludge judge Yes No NA NE ❑ ❑ ❑ ® ❑ ❑ ❑ Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ 0 II 0 application? Is the facility as described in the permit? ® ❑ 0 0 # Are there any special conditions for the permit? ❑ ❑ ® 0 Is access to the plant site restricted to the general public? 0 0 0 Is the inspector granted access to all areas for inspection? 1 0 0 0 Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? ® 0 0 0 Is all required information readily available, complete and current? ® 0 0 0 Are all records maintained for 3 years (lab. reg. required 5 years)? © 0 0 0 Are analytical results consistent with data reported on DMRs? 1 ❑ ❑ ❑ Is the chain -of -custody complete? I ❑ ❑ 0 Dates, times and location of sampling l Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? 1 0 0 0 Has the facility submitted its annual compliance report to users and DWQ? ■ ❑ ❑ ❑ Page# 3 Permit: NC0072877 Owner - Facility: Newton Grove VVVVTP Inspection Date: 06/26/2014 Inspection Type: Compliance Evaluation Record Keeping (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? Is the ORC visitation log available and current? Is the ORC certified at grade equal to or higher than the facility classification? Is the backup operator certified at one grade less or greater than the facility classification? Is a copy of the current NPDES permit available on site? Facility has copy of previous year's Annual Report on file for review? Comment: Yes No NA NE ❑ ❑ ® ❑ ® ❑ ❑ ❑ ® ❑ ❑ ❑ El El It El El El III El El El Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? ® ❑ ❑ ❑ Is flow meter calibrated annually? IN ❑ ❑ ❑ Is the flow meter operational? II ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ® ❑ Comment: Calibrated on 12/4/2013 Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: Yes No NA NE PM ® ❑ ❑ ❑ IN ❑ ❑ ❑ ® ❑ ❑ ❑ ® ❑ ❑ ❑ Equalization Basins Yes No NA NE Is the basin aerated? II ❑ ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? ® ❑ ❑ ❑ Is the basin free of excessive grease? ❑ ❑ ❑ Are all pumps present? ® ❑ ❑ ❑ Are all pumps operable? 1 ❑ ❑ ❑ Are float controls operable? ❑ ❑ ❑ II Are audible and visual alarms operable? ❑ ❑ ❑ MI Page# 4 Permit: NC0072877 Owner - Facility: Newton Grove WWT'P Inspection Date: 06/26/2014 Inspection Type: Compliance Evaluation Equalization Basins # Is basin size/volume adequate? Comment: Secondary Clarifier Is the clarifier free of black and odorous wastewater? Is the site free of excessive buildup of solids in center well of circular clarifier? Are weirs level? Is the site free of weir blockage? Is the site free of evidence of short-circuiting? Is scum removal adequate? Is the site free of excessive floating sludge? Is the drive unit operational? Is the return rate acceptable (low turbulence)? Is the overflow clear of excessive solids/pin floc? Is the sludge blanket level acceptable? (Approximately 1/1 of the sidewall depth) Comment: Filtration (High Rate Tertiary) Type of operation: Is the filter media present? Is the filter surface free of clogging? Is the filter free of growth? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids and filter media? Comment: Yes No NA NE • ❑ ❑ ❑ Yes No NA NE NI ❑ ❑ ❑ El 0 El II 0 El El II ❑ ❑ ❑ II ❑ ❑ ❑ III ❑ .❑ ❑ ▪ ❑ ❑ ❑ • ❑ ❑ ❑ III ❑ ❑ ❑ 0 El 0 II Yes No NA NE • Cross flow ® ❑ ❑ ❑ El 0 El ® ❑ ❑ ❑ ❑ ❑ MI ❑ ❑ ❑ i ❑ • ❑ ❑ ❑ Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? 1. ❑ ❑ ❑ Are UV bulbs clean? II ❑ 0 ❑ Is UV intensity adequate? 11 0 ❑ 0 Is transmittance at or above designed level? ❑ ❑ 0 Is there a backup system on site? ❑ ❑ • ❑ Page# 5 Permit: NC0072877 Owner -Facility: Newton Grove VVWTP Inspection Date: 06/26/2014 Inspection Type: Compliance Evaluation Disinfection - UV Yes No NA NE Is effluent clear and free of solids? ® ❑ ❑ ❑ Comment: Standby Power Is automatically activated standby power available? Is the generator tested by interrupting primary power source? Is the generator tested under load? Was generator tested & operational during the inspection? Do the generator(s) have adequate capacity to operate the entire wastewater site? Is there an emergency agreement with a fuel vendor for extended run on back-up power? Is the generator fuel level monitored? Comment: Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/I) Comment: Yes No NA NE ® ❑ ❑ ❑ 11 El El 0 El El El 11 ® ❑ ❑ ❑ ® ❑ ❑ ❑ Yes No NA NE Ext. Air Surface ® ❑ ❑ ❑ 11 ❑ ❑ ❑ ❑ ❑ ® ❑ 11 El El El ❑ ❑ ❑ ❑ ❑ ❑ 11 Page# 6