Loading...
HomeMy WebLinkAboutNC0020117_Pretreatment Inspection_20010921ATA NCDENR North. Carolina Department of Environment and. Natural Resources Michael F. Easley, Governor September 21, 2001 Mr. Wayne Hollowell Director of Public Works & Utilities City of Clinton P.O. Box 199 Clinton, NC 28328-0199 SUBJECT: Pretreatment Compliance Inspection (PCI) City of Clinton Wastewater Treatment Plant NPDES Permit No. NC0020117 Sampson. County Dear Mr. Hollowell: William G. Ross Jr., Secretary Gregory J. Thorpe, Ph.D. Acting Director Division of Water Quality Enclosed you will find a copy of the Pretreatment Compliance Inspection Report for the inspection conducted on August 22, 2001 at the City of Clinton, Norman H. Larkins Wastewater Treatment Plant in which I met with Enrique Coello. The report indicates that the Clinton WWTP meets the pretreatment requirements as outlined in 15A NCAC 2H .0900 for Local Pretreatment Programs. Please send the Industrial Waste Survey to the Pretreatment Unit for approval as soon as possible. A file review was performed on the records of Sanmina, Nestaway, and Sampson County Department of Corrections. The report is self-explanatory and contains observations and recommendations. -If you or your staff have any questions, please do not hesitate to contact me at (910) 486-1541. • Sincerely, Dale Lopez Environmental Specialist /dl Enclosure: Pretreatment Compliance Inspection (PCI) Report cc: Keyes McGee, DWQ Pretreatment Unit Enrique Coello, Pretreatment Coordinator, City of Clinton Fayetteville Regional Office 225 Green Street— Suite 714, Fayetteville, North Carolina 28301-5043 Phone: 910-486-1541 1 FAX 910-486-07071 Internet: www.enr.state.nc.us/ENR An Equal Opportunity 1 Affirmative Action Employer — 50% Recycled \ 10% Post Consumer Paper NORTH CAROLINA DIVISION OF WATER QUALITY PRETREATMENT COMPLIANCE INSPECTION (PCI) REPORT FAYETTEVILLE REGIONAL OFFICE 1. Control Authority (POTW) Name: City of Clinton WWTP 2. Control Authority Representative: Enrique Coello 3. Title(s): Pretreatment Coordinator/ ORC 4. Last Inspection Date: October 10, 2000 Inspection Type (Circle One): PCI 5. Has Program Completed All Requirements from the Previous Inspection or Program Info Sheet(s)? 6. Is POTW under an Order That Includes Pretreatment Conditions? Order Type And Number: Are Milestone Dates Being Met? Yes / No Audit PCS CODING Trans.Code )N� Program NPDES Number 1NICIO 1012101111 17[ MM/DD/YY 08 /22 /01 (DTIAI Inspec.Type JPl (TYPI) Inspector (INSP) fres / No Yes / No Fac.Type !11 (FACC) 7. Current Number of Significant Industrial Users (SIUs)? 7 SIUS 8. Current Number of Categorical Industrial Users (CIUs)? 3 CIUS 9. Number of SIUs Not Inspected by POTW in the Last Calendar Year? 0 10. Number of SIUs Not Sampled by POTW in the Last Calendar Year? 0 11. Enter the Higher Number of 9 or 10. 0 NOIN 0 NO CM 12. Number of SIUS With No IUP or With an Expired IUP? Just renewed the permits on June 10, 2001 13. Number of SIUs In SNC for Either Reporting or Limits Violations During Either of the Last 2 Semi -Annual Periods (Total Number of SIUs in SNC). 0 PSNC 14. Number of SIUs in SNC for Reporting During Either of the Last 2 Semi -Annual Periods. 0 MSNC 15. Number of SIUs in SNC for Limits Violations During Either of the Last 2 Semi -Annual Periods? 0 SNPS 16. Number of SIUs in SNC for Both Reporting and Limits Violations During Either of the Last 2 Semi -Annual Periods? 0 POTW INTERVIEW 17. Since the Last PCI, has the POTW had any NPDES Limits Violations? If Yes, What are the parameters and how are these problems being addressed? 18. Since the Last PCI, has the POTW had any Problems Related to an Industrial Discharge (Interference, Pass -Through, Blockage, Citizens' Complaints, Increased Sludge Production, Etc.)? If Yes, How Are These Problems Being Addressed? YES NO YES NO 19. Which Industries have been in SNC during either of the Last 2 Semi- SNC for Limits: Annual Periods? Have any Industries in SNC (During Either of the Last 2 Semi -Annual Periods) not been Published for Public Notice? SNC for Reporting: (May refer to PAR if Excessive SIUs in SNC) Not Published: 20. Which Industries are on Compliance Schedules or Orders? For all SIUs on an Order, Has a Signed copy of the Order been sent to the Division? 21. Are any Permits or Civil Penalties Currently Under Adjudication? If Yes, Which Ones? 0 0 0 0 YES f N0 PRETREATMENT PROGRAM ELEMENTS REVIEW —Please review POTW files and complete the following: Program Element Date of Last Approval Date Next Due, If Applicable Headwork Analysis (HWA) 05/04/01 Industrial Waste Survey (IWS) 08/22/96 As Soon As Possible Sewer Use Ordinance (SUO) 03/07/97 Enforcement Response Plan (ERP) 05/18/01 Long Term Monitoring Plan (LTMP 05/18/01 22. Is the LTMP Monitoring Being Conducted at Appropriate. Locations and Frequencies? 23. Should any Pollutants of Concern be Eliminated From or Added to the LTMP? If Yes, which ones? Eliminated: Added: 24. Are Correct Detection Levels being used for all LTMP Monitoring? 25. Is the LTMP Data Maintained in a Table or Equivalent? Yes / No Is the Table Adequate? Yes NoI fres Yes INDUSTRIAL USER PERMIT (UP) FILE REVIEW 26. User Name 1. Sanmina 2. Nestaway 3.DOC (Sampson County) 27. IUP Number 00081 0009 10002 28. Does File Contain Current Permit? [Yes / No Yes/No M o 29. Permit Expiration Date? 05/31/05 05/31/05 05/31/05 30. Categorical Standard Applied (I.E. 40 CFR 413, Etc.) or N/A 433 433 N/A 31. Does the File Contain Permit Application Completed Within One Year Prior to Permit Issue Date? [Yes / No es No WM i o 08/17/99 11/12/99 11/19/99 32. Does the File Contain an Inspection Completed Within Last Calendar Year? . [Yes / No Yes/No NS i o 05/18/01 06/20/01 06/13/01 33. a. Does File Contain A Slug Control Plan? b. If No, is One Needed? (See Inspection Form from POTW) a. b. Yes Yes / / No No a.Yes/NoYes/No b. Yes/No Yesl[Nol 34. For 40 CFR 413 And 433 TTO Certifiers, Does The File Contain A Toxic Organic Management Plan (TOMP)? Yes / Nol N/A Yes i i /A N/A Letter sent to CA Letter sent to quarterly] CA quarterly 35. a. Does the File Contain Original Permit Review Letter from the Division? b. All Issues Resolved? a.Yes / No OMi to E i to b.Yes / No N/A Yes/No N/A N/A 36. During the Most Recent Semi -Annual Period, Did the POTW Complete its Sampling as Required by IUP? !Yes / No E i o ME t To 37. Does File Contain POTW Sampling Chain -Of -Custody's? [Yes / No E o E o 38. During the Most Recent Semi -Annual Period, Did the SIU Complete its Sampling as Required By IUP? am i o Yes/No Y No N/A lby POTWil 39. Does Sampling Indicate Flow or Production? FYes / No N/A El i o Elli ro 40. During the Most Recent Semi -Annual Period, Did the POTW Identify All Non -Compliance from Both POTW and SIU Sampling? lYes / No OM i o Yes/No 41. a. Was the POTW Notified by SIU (Within 24 Hours) of All Self- Monitoring Violations b. Did Industry Resample Within 30 Days? a.Yes / No/ N/A N Nisum i o/ N/A i To N/A Not required b. es No/ N/A N/A 42. Was the SIU Promptly Notified of any Violations (Per ERP)? Yes / No N/A Yes/No N 43. During the Most Recent Semi -Annual Period, Was the SIU in SNC?. Yes / No Yes/IV I E 44. During the Most Recent Semi -Annual Period, Was Enforcement Taken as Specified in the POTWs ERP? Yes /No/ N/A E o N/A N/AI 45. Does the File Contain Penalty Assessment Notices? Yes / No N/A Yes/No/ N/A N/A 46. Does the File Contain Proof of Penalty Collection? Yes / No N/A Yes/No N/AI IN/AI 47. a. Does the File Contain any Current Enforcement orders? b. Is SIU in Compliance with Order? a.Yes / No b.Yes / No Yes/No / N/Al pi/A Yes/No/ N/AI N/A N/A 48. Did the POTW Representative Have Difficulty in Obtaining any of this Requested Information for You? Yes / No Yes/IN1 No FILE REVIEW COMMENTS PCI SUMMARY AND COMMENTS PCI Comments: This facility has an organized pretreatment program. Files are neat and organized. Requirements: Please send the Industrial Waste Survey (IWS) to the Pretreatment Unit for approval as soon as possible. The Industrial Waste Survey and the Head Works Analysis (HWA) are due every five years. Recommendations: NOD: YES NOV: YES QNCR: YES POTW Rating: NO NO NO Satisfactory X Marginal Unsatisfactory / PCI COMPLETED BY: Dale Lopez, Environmental Specialist Ni-�6& L cl�>> Date: 09/21/01 INDUSTRY INSPECTION CODING: Trans.Code Main Program Permit Number MM/DD/YY Inspec.Type Inspector Fac.Type N1 11 I 1 1 / / jIl Ls.1 121 (DTIA) (TYPI) (INSP) (FACC) 1. Industry Inspected: 2. Industry Address: 3. Type of Industry/Product: 4. Industry Contact: 5. Phone: Fax: 6. Does the POTW use The Division Model Inspection Form or Equivalent? Yes / No 7. Did the POTW Contact Conduct the Following Parts of the Industrial Inspection Thoroughly? Comments: A. Initial Interview B. Plant Tour C. Pretreatment Tour D. Sampling Review E. Exit Interview Industrial Inspection Comments: