HomeMy WebLinkAboutNCG550655_Inspection_20210816DocuSign Envelope ID: 7D6E82A3-F1AD-434A-9AAE-9CC587105F0C
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code
1 IN I 2 IL
21IIIIII
NPDES yr/mo/day Inspection
I 3 I NCG550655 111 121 21/08/10 117
Type
1810I
IIIIIIIIIII
Inspector Fac Type
19I S I 2011
IIIIIIIIIIIIIIIIII I IIIIII
P6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
671 I 70I I 711 1 72 I N I 73I 1 74 71
I I
I I I I I I 180
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Laurel Creek Mobile Home Park
4136 NC Hwy 18 S
Morganton NC 28655
Entry Time/Date
11:OOAM 21/08/10
Permit Effective Date
20/04/07
Exit Time/Date
12:30PM 21/08/10
Permit Expiration Date
20/10/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Jevon M Morris,508 Riverside Dr Morganton NC 28655//828-433-7735/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran Facility Site Review Effluent/Receiving Wate
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s)
Linda S Wiggs
of Inspector(s)
DS
PIO
Agency/Office/Phone and Fax Numbers Date
DWR/ARO WQ/828-296-4500 Ext.4653/
Signature of Management Q A Reviewer
,-ps Agency/Office/Phone and Fax Numbers Date
44
•
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page# 1
DocuSign Envelope ID: 7D6E82A3-F1AD-434A-9AAE-9CC587105F0C
3I
NPDES yr/mo/day
N CG550655 I11 121 21/08/10
17
Inspection Type
18LI
(Cont.)
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
The Inspector, Linda Wiggs, met with the Owner, Jevon Morris, onsite.
No site plans were found in the Division of Water Resource records. The Owner walked the Inspector
through the property pointing out where he believes the wastewater components are located,
including three septic tanks, lines, the sand filter, the chlorine contact components and the discharge
pipe.
This is an old system that was under an Individual Permit (NC0057631) when first issued; it was
transitioned to a General Permit in 1993. Depending on how many of the trailers are occupied,
given at least two bedrooms at 120 gallons per bedroom, this system if not operated and maintained
properly could fail, requiring new treatment components and/or have to go under an Individual Permit
again. The Inspector asked the Burke County Health Department (HD) to search their records for
information on this site. Burke County HD found no records associated with this site for conventional
septic system having been installed.
Recent sampling was compliant with permit limitations and all tanks had recently been pumped by
Asbury's Septic. Chlorine tablets were present, with two tubes in use. We discussed the rate at
which chlorine tablets are to be added to the tubes given there may be groundwater present; more
frequent checks to add tablets is likely needed. More frequent pumping of the septic tanks may also
be necessary.
Eight trailers are onsite; five are rented. We discussed how many people were on the system at the
time of the inspection - the Owner believed three were at home. There was a moderate flow
discharging at the time of the inspection. The DWR historical file mentions the presence of
groundwater; it is likely groundwater remains present.
The NCG550655 Permit is for system discharging no more than 1,000 gallons per day. The amount
of wastewater flow from this system is to be reported to the Asheville Regional Office. Refer to the
Notice of Deficiency NOD-2021-PC-0433.
Page# 2
DocuSign Envelope ID: 7D6E82A3-F1AD-434A-9AAE-9CC587105F0C
Permit: NCG550655
Inspection Date: 08/10/2021
Owner - Facility: Laurel Creek Mobile Home Park
Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable El El El
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new El ❑ ❑
application?
Is the facility as described in the permit? El El • El
# Are there any special conditions for the permit? El El • El
Is access to the plant site restricted to the general public? ❑ ❑ • ❑
Is the inspector granted access to all areas for inspection? • ❑ ❑ ❑
Comment: Billing is current.
Septic Tank Yes No NA NE
(If pumps are used) Is an audible and visual alarm operational? ❑ ❑ • ❑
Is septic tank pumped on a schedule? • ❑ ❑ ❑
Are pumps or syphons operating properly? ❑ El • ❑
Are high and low water alarms operating properly? ❑ ❑ • ❑
Comment: All tanks were recently pumped; receipts were presented.
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: Moderate flow; groundwater likely present. Recent Fecal Coliform, TSS and BOD
sample results were presented and compliant.
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
Yes No NA NE
❑ ❑ • ❑
Page# 3
DocuSign Envelope ID: 7D6E82A3-F1AD-434A-9AAE-9CC587105F0C
Permit: NCG550655
Inspection Date: 08/10/2021
Owner - Facility: Laurel Creek Mobile Home Park
Inspection Type: Compliance Evaluation
Effluent Sampling Yes No NA NE
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 ❑ ❑ ❑ •
degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type ❑ • ❑ ❑
representative)?
Comment: Flow needs to be measured. See summary.
Disinfection -Tablet Yes No NA NE
Are tablet chlorinators operational? • ❑ ❑ ❑
Are the tablets the proper size and type? ■ ❑ ❑ ❑
Number of tubes in use? 2
Is the level of chlorine residual acceptable? ❑ ❑ ❑ •
Is the contact chamber free of growth, or sludge buildup? • ❑ ❑ ❑
Is there chlorine residual prior to de -chlorination? ❑ ❑ ❑ •
Comment:
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit? ❑ • ❑ ❑
Is all required information readily available, complete and current? ❑ • ❑ ❑
Are all records maintained for 3 years (lab. reg. required 5 years)? ❑ • ❑ ❑
Are analytical results consistent with data reported on DMRs? ❑ ❑ • ❑
Is the chain -of -custody complete? ❑ ❑ ❑ •
Dates, times and location of sampling ❑
Name of individual performing the sampling ❑
Results of analysis and calibration ❑
Dates of analysis ❑
Name of person performing analyses ❑
Transported COCs ❑
Are DMRs complete: do they include all permit parameters? ❑ ❑ • ❑
Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ • ❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified ❑ ❑ • ❑
operator on each shift?
Is the ORC visitation log available and current? ❑ ❑ • ❑
Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ • ❑
Page# 4
DocuSign Envelope ID: 7D6E82A3-F1AD-434A-9AAE-9CC587105F0C
Permit: NCG550655
Inspection Date: 08/10/2021
Owner - Facility: Laurel Creek Mobile Home Park
Inspection Type: Compliance Evaluation
Record Keeping
Is the backup operator certified at one grade less or greater than the facility
classification?
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Yes No NA NE
❑ ❑ • ❑
▪ El El El
❑ ❑ • ❑
Comment: Flow rate was not available. Gallons per day of wastewater needs to be determined.
See summary for details.
Page# 5