HomeMy WebLinkAboutNCG080760_Inspection Report_20210818Compliance Inspection Report
Permit: NCG080760 Effective: 07/01/21 Expiration: 06/30/26 Owner : ABF Freight System Inc
SOC: Effective: Expiration: Facility: ABF Freight System Incorporated
County: Forsyth 1165 NC Hwy 66 S
Region: Winston-Salem
Kernersville NC 27284
Contact Person: Tisha Cochran Title: Phone: 479-785-6026
Directions to Facility:
System Classifications: SWNC,
Primary ORC: Certification: Phone:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 08/18/2021 Entry Time 11:OOAM Exit Time: 12:15PM
Primary Inspector: Levi Hiatt Phone: 336-776-9658
Secondary Inspector(s):
Tyler B Pearson
Reason for Inspection: Routine Inspection Type: Technical Assistance
Permit Inspection Type: Transportation w/Vehicle Maintenance/Petroleum Bulk/Oil Water Separator Stormwater Discharge COC
Facility Status: ❑ Compliant ❑ Not Compliant
Question Areas:
Other
(See attachment summary)
Page 1 of 3
Permit: NCG080760 Owner - Facility:ABF Freight System Inc
Inspection Date: 08/18/2021 Inspection Type : Technical Assistance Reason for Visit: Routine
Inspection Summary:
This site was inspected on August 18, 2021, by Levi Hiatt and Tyler Pearson in response to a Technical Assistance request
The facility requested that Outfall 002 be moved to the most southeast corner of the parking lot, due to the current outfall
location being in an earthen channel and possibly increasing the Total Suspended Solids contents of the sampling results
Upon inspecting the facility, it was determined that Outfall 002 could be moved to the most southeast corner of the parking
lot, with the exception that an additional monitoring location be added at the curb inlet directly southwest of the fueling
station.
It was also determined that another monitoring location will need to be added in the trailer parking area directly north of the
main building.
Furthermore, there were a few issues that also need to be addressed to be in compliance with the current permit. Please
see the below comments.
Outfall 001 appeared to be clogged with debris and was not properly functioning during the inspection (an adequate rain
event had just occurred prior to inspection). This outfall needs to be cleaned out to restore its functionality.
The outfall that serves the two yard inlets on the north side of the parking lot was overgrown with vegetation, and was not
accessible. A path needs to be maintained for all outfalls so that they are easily reachable. Furthermore, this outfall is not
listed in our database and will need to be added.
Debris and trash were noted around the perimeter fence of the facility, and around the outfalls. Please clean-up all debris
and trash around the facility and the outfalls.
There are two above ground oil tanks with capacities greater than 660-gallons. It is unclear if these tanks are double walled.
If the tanks are not double walled, secondary containment must be provided for these tanks. If the thanks are double walled,
please submit verification to this office.
A reinspection will occur within 30-days of receipt of this report. Please contact this office if there are any questions.
Page 2 of 3
Permit: NCG080760
Inspection Date: 08/18/2021
Other
Comment:
Owner - Facility:ABF Freight System Inc
Inspection Type : Technical Assistance Reason for Visit: Routine
Yes No NA NE
Page 3 of 3