Loading...
HomeMy WebLinkAboutSW1191201_Supplement-EZ Form_20210818WET POND 1 Drainage area number A2 B1 _ _ 2 Design volume of SCM (cu ft) 45874 cf 13124 cf GENERAL Nldc FREW Q2H 1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? yes *as 4 Is the SCM located away from contaminated soils? Yes Yes 5 W hat are the side slopes of the SCM (H:V)? 3:1 3:1 Does the SCM have retaining walls, gabion walls or other engineered 6 side slopes? No No Are the inlets, outlets, and receiving stream protected from erosion 7 (10- ear storm)? Yes Yes Is there an overflow or bypass for inflow volume in excess of the 8 desyn volume? Yes Yes 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice Drawdown Orifice 10' if applicable; VA the SCM be cleaned out after construction? Yes Yes 11 Does the maintenance access comply with Generat MDC (8)? Yes Yes 12 Does the drainage easement comply with General MDC (9)? If the SCM is on a single family lot, does (will?) the plat comply with 13 General MDC (10)? 1 14_Is there an O&M Agreement that complies with General MDC (11)? Yes Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes Yes 16 Does the SCM follow the device specjfto MDC? Yes Yes 17 Was the SCM designed by an NC licensed professional? WET POND MDC FROM 02H .1053 18[Method used Yes SA/DA Yes SA/DA 19 Has a stagelstom a table been provided in the calculations? Yes Yes 20 Elevation of the excavated main pool depth (bottom of sediment removal) (fmsl) 1196.00 1203.50 21 Elevation of the main pool bottom -(top of sediment removal) (fmsl) 1197.00 1204.00 22 Elevatlon'or the bottom of the.yegeWted shell (fmsl) 1201.00 1210.00 23 Elevation of the permanent pool (fmsl) 1201.50 1210.50 24 Elevallco ofthe,top of the vegetated shelf (fmsl) 1202.00 1211.00 25 Elevation of the temporary pool (fmsl) 1203.10 1212.25 261Surface area of the main permanent pool (square feet) 21548.00 5502.00 27 Volume of the main permanent pool (cubic feet) [ 71664 cf 18510 cf 281Average depth of the main pool (feet) 3.33 ft 3.25 ft 29, Average,depth equaffon and Equation 2 Equation 2 30 j If using equation 3, main pool perimeter (feet) 31 3 21 If using equation 3, width of submerged veg. shelf (feet) Voluma of the forebay (cubic feet) 11876 cf 2940 cf 331 Is this 15-20% of the volume in the main pool? Yes Yes 34 Clean-vut depth for forebay (inches) 54 in 51 in 35 Design volume of SCM (cu ft) 45874 cf 13124 cf 36 is the outlet an orifice or a weir? Orifice Orifice 371 If orifice, orifice diameter (inches) 3.5 in 1.5 in 381 if weir, weir height (inches) 39[ If weir, weir length (inches) 40 Drawdown time for the temporary pool (days) 2.4 3.6 41 Are the inlet(s) and outlet located in a manner that avoids short- circuiting? Yes Yes 42 Are berms or baffles provided to improve the flow path? No No 43 Depth of forebay at entrance (inches) 66 in 60 in 441 Depth of forebay at exit (inches) [ 60 in 54 in 45 Does water flow out of the forebay in a non -erosive manner? Yes Yes 46 1 Wfdth of the vegetated shelf (fast) 6 ft 6 ft 471 Slope of vegetated shelf (H:V) 6:1 6:1 48 Does the orifice drawdown from below the top surface of the permanent pool? Yes Yes 49 Does the pond minimize impacts to the receiving channel from the 1- yr, 24-hr storm? Yes Yes 50 Are fountains proposed? (If Y, please provide documentation that MDC(9) is met.) No No 51 Is a trash rack or other device provided to protect the outlet system? Yes Yes 52IAre the dam and embankment planted in non -clumping turf grass? Yes Yes 53! Species of turf that will be used on the dam and embankment Bermuda Bermuda 54 1 Has a pts n ng p n.been provided for the vegetated she e$ Yes ADDITIONAL INFORMATION Please use this space to provide any additional information about the 55 wet pond(s): Parcel is state owned land, therefore no drainage easement is required. Wet Pond 3 10:21 AM 8/10/2021