Loading...
HomeMy WebLinkAboutWI0100624_Application_20210809Speedway LLC Speedway Office 500 Speedway Drive Enon, OH 45323 Telephone 937-864-3000 July 23, 2021 Ms. Shristi Shrestha North Carolina Department of Environment Quality Division of Water Quality — Aquifer Protection Section, UIC Program 1636 Mail Service Center Raleigh, North Carolina 27699-1636 Re: Notice of Intent to Construct or Operate Injection Wells Subsurface Injection Pilot Study Speedway No. 7917 527 West Main Street Forest City, Rutherford County, North Carolina NCDEQ Incident No. 23681 NCDEQ Priority Ranking: Intermediate Dear Ms. Shestha: Speedway LLC (Speedway) is submitting the enclosed Notice of Intent to Construct or Operate Injection Wells prepared by our environmental consultant ATC Associates of North Carolina, P.C. (ATC). The permit application covers injection of Klozur ® CR. The injection event will be conducted at two distinct areas on the site, in the vicinity of monitoring well MW-03R and in the vicinity of monitoring well MW-15. Injection of remediation product will occur in the vicinity of monitoring well MW-03R through existing groundwater recovery wells (RW-01 and RW-02). Injection of remediation product in the vicinity of monitoring well MW- 15 will be accomplished through direct push technology at three injection points. If you have any questions or require additional information, please contact me at 919-516-8069 or by email at cachiara@speedway.com. Sincerely, Speedway LLC Charles A. Chiara Environmental Representative Attachments cc: ATC Associates of North Carolina, P.C., 7606 Whitehall Executive Center Drive, Suite 800, Charlotte, NC 28273 Speedway No. 7917 NOTICE OF INTENT FORM June 30, 2021 NC Department of Environmental Quality — Division of Water Resources (DWR) NOTIFICATION OF INTENT (NOI) TO CONSTRUCT OR OPERATE INJECTION WELLS The following are "permitted by rule" and do not require an individual permit when constructed in accordance with the rules of ISA NCAC 02C.0200 (NOTE: This form must be received at least 14 DAYS prior to injection) AQUIFER TEST WELLS (.15A NCAC 02C .0220) These wells are used to inject uncontaminated fluid into an aquifer to determine aquifer hydraulic characteristics. IN SITU REMEDIATION (15A NCAC 02C .0225) or TRACER WELLS (I5A NCAC 02C .0229): 1) Passive Injection Systems - In -well delivery systems to diffuse injectants into the subsurface. Examples include ORC socks, iSOC systems, and other gas infusion methods (Note: Injection Event Records (TER) do not need to be submitted for replacement of each sock used in ORC systems). 2) Small -Scale Injection Operations — Injection wells located within a land surface area not to exceed I0,000 square feet for the purpose of soil or groundwater remediation or tracer tests. An individual permit shall be required for test or treatment areas exceeding�10,000 square feet. 3) Pilot Tests - Preliminary studies conducted for the purpose of evaluating the technical feasibility of a remediation strategy in order to develop a full scale remediation plan for future implementation, and where the surface area of the injection zone wells is located within an area that does not exceed five percent of the land surface above the known extent of groundwater contamination. An individual permit shall be required to conduct more than one pilot test on any separate groundwater contaminant plume. 4) Air Injection Wells - Used to inject ambient air to enhance in -situ treatment of soil or groundwater. 5) In -Situ Thermal Wells (IST) —Used to 'heat' contaminated groundwater to enhance remediation Print Clearly or Type Information. Illegible Submittals Will Be Returned as Incomplete. DATE: July 6 , 2021 PERMIT NO. (to be filled in by DWR) NOTE- If this NOI is being submitted as notification of a modification of a previously issued NOI for this site (e.g., different injection wells, plume, additives, etc.) and still meets the deemed permitted by rule criteria, provide the previously assigned permit tracking number and any needed relevant information to assess and approve injection: A. B. Permit No. WI Issued Date: WELL TYPE TO BE CONSTRUCTED OR OPERATED (1) Air Injection Well Complete sections B through F. J, M (2) Aquifer Test Well .Complete sections B through F, J, M (3) Passive Injection System ..Complete sections B through F, H-M (4) Small -Scale Injection Operation Complete sections B through M (5) X Pilot Test Complete sections B through M (6) In -Situ Thermal (IST) Well Complete all sections except K STATUS OF WELL OWNER: ilo(; e Deemed Permitted GW Remediation NO1 Rev. 2-14-2020 Page 1 C. WELL OWNER(S) — State name of Business/Agency, and Name and Title of person delegated authority to sign on behalf of the business or agency: Name(s): Speedway LLC (John M. Helms — Manager. Environmental Remediation) Mailing, Address: 500 Speedway Drive City: Enon State: OH Zip Code: 45323 County: Clark Day Tele No.: 937-863-6507 Cell No.: Not Available EMAIL Address: jmhelms@speedway.com Fax No.: Not Available D. PROPERTY OWNER(S) (if different than well owner/applicant) Name and Title: Same Company Name Mailing Address: City: State: Zip Code: County: Day Tele No.: Cell No.: EMAIL Address: Fax No.: E. PROJECT CONTACT (Typically Environmental Consulting/Enaineering Firm) Name and Title: Bob Bolton. Senior Project Manager Company Name ATC Associates of North Carolina. P.C. Mailing Address: 2725 East Millbrook Road. Suite 121 City: Raleigh State: NC Zip Code: 27604 County: Wake Day Tele No.: 919-871-0999 Ce11 No.: 803-767-1552 EMAIL Address: bob.bolton@atcas.com Fax No.: 737-207-8261 F. PHYSICAL LOCATION OF WELL SITE (1) Facility Name & Address: Speedway No. 7917 523 West Water Street City: Forest City County: Rutherford Zip Code: 28043 (2) Geographic Coordinates: Latitude*: ° " or 35 °. 339526N Longitude**: ° " or -81 °. 877044W Reference Datum: Accuracy: Method of Collection: Goog,le Earth **FOR AIR INJECTION AND AQUIFER TEST WELLS ONLY: A FACILITY SITE MAP WITH PROPERTY BOUNDARIES MAY BE SUBMITTED IN LIEU OF GEOGRAPHIC COORDINATES. G. TREATMENT AREA Land surface area of contaminant plume: square feet Land surface area of inj. well network: 800 square feet (< 10,000 ft2 for small-scale injections) Percent of contaminant plume area to be treated: 5% (must be < 5% of plume for pilot test injections) Deemed Permitted GW Remediation NO1 Rev. 2-14-2020 Page 2 H. INJECTION ZONE MAPS — Attach the following to the notification. (1) Contaminant plume map(s) with isoconcentration lines that show the horizontal extent of the contaminant plume in soil and groundwater, existing and proposed monitoring wells, and existing and proposed injection wells; and (2) Cross-section(s) to the known or projected depth of contamination that show the horizontal and vertical extent of the contaminant plurne in soil and groundwater, changes in lithology, existing and proposed monitoring wells, and existing and proposed injection wells. (3) Potentiometric surface map(s) indicating- the rate and direction of groundwater movement, plus existing and proposed wells. See Figures I through 8 for site location, injection zone maps, and cross sections. DESCRIPTION OF PROPOSED INJECTION ACTIVITIES AT THE SITE — Provide a brief narrative regarding the cause of the contamination, and purpose, scope, goals of the proposed injection activity: ATC will install Klozur ® CR(Persulfate and calcium peroxide in recovery wells RW-01 and RW-02. Injection of the remediation product will occur in the vicinity of MW-15 through direct push technology in order to aide in natural attenuation and reduce compounds concentrations to below the North Carolina Groundwater Quality Standards (2L Standards). Based on the most recent sampling event performed in October 2020. several compounds exceeding 2L Standards were detected in the site monitoring and recovery wells. ATC will install the remediation product at a depth of approximately 25 feet below land surface. Groundwater monitoring for chemicals of concern will take place prior to the application followed by additional sampling events at one month. three months and six months post application. ATC will also measure dissolved oxygen, conductivity. temperature. pH. and oxygen reduction potential in the site monitoring wells. J. WELL CONSTRUCTION DATA (1) No. of injection wells: 3 Proposed 2 Existing (provide NC Well Construction Record (GW-1) for each well) — See Appendix A (2) Appx. injection depths (BLS): 25 feet (3) For Proposed wells or Existing wells not having GW-1 s, provide well construction details for each injection well in a diagram or table format. A single diagram or line in a table can be used for multiple wells with the same construction details. Well construction details shall include the following (indicate if construction is proposed or as -built): (a) Well type as permanent, Geoprobe/DPT, or subsurface distribution infiltration gallery (b) Depth below land surface of casing, each grout type and depth, screen, and sand pack (c) Well contractor name and certification number K. INJECTION SUMMARY NOTE: Only injectants approved by the epidemiology section of the NC Division of Public Health, Department of Health and Human Services can be injected. Approved injectants can be found online at http://deq. nc. goy/about/divisions/water-resources/water-resources-permits/wastewater-branch/ground-water- protection/ground-water-approved-injectants. All other substances must be reviewed by the DHHS prior to use. Contact the UIC Program for more info if you wish to get approval for a different additive. However, please note it may take 3 months or longer. Deemed Permitted GW Remediation NOI Rev. 2-14-2020 Page 3 Injectant: Klozur ® CM (See Appendix B for MSDS) Total Amt. to be injected (gal)/event: 277 Amt. Water to be injected (gal/event): 2,200 gallons Total Amt. to be injected (gallevent): 2,477 gallons No. of separate injection events: 1 Est. Total Amt. to be injected (gal): 2,477 Source of Water (if applicable): On site municipal water L. MONITORING PLAN — Describe below or in separate attachment a monitoring plan to be used to determine if violations of groundwater quality standards specified in Subchapter 02L result from the injection activity. Semi-annual sampling events of all monitoring wells are performed. ATC's next sampling event will occur October 2021. During the sampling event. ATC will collect samples from the monitoring well network for analysis of volatile organic compounds by EPA Method 6200B including_ methyl tertiary -butyl ether (MTBE) and isopropyl ether (1PE). The sample will be shipped to Pace Laboratories in Mount Juliet, Tennessee. M. SIGNATURE OF APPLICANT AND PROPERTY OWNER Well Owner/Applicant: "I hereby certify, under penalty of law, that I am familiar with the information submitted inthis document and all attachments thereto and that, based on my inquiry of those individuals immediately responsible for obtaining said information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties, including the possibility of fines and imprisonment, for submi s ise information. 1 agree to construct, operate, maintain, repair, and if applicable, abandon the inje or ell and all rappurtenances in accordance with the 15A NCAC 02C 0200 Rules." John M. Helms — Manager, Environmental Remediation Signatu e of Applicant Print or Type Full Name and Title Property Owner (if the property is not owned by the Well Owner/Applicant): "As owner of the property on which the injection well(s) are to be constructed and operated, I hereby consent to allow the applicant to construct each injection well as outlined in this application and agree that it shall be the responsibility of the applicant to ensure that the injection well(s) conform to the Well Construction. Standards (15A NCAC 02C .0200)." "Owner" means any person who holds the fee or other property rights in the well being constructed. A well is real property and its construction on land shall be deemed to vest ownership in the land owner, in the absence of contrary agreement in writing. Signature*. of Property Owner (if different from applicant) Print or Type Full Name and Title *An access agreement between the applicant and property owner may be submitted in lieu of a signature on this form. Please send 1 (one) hard color copy of this NOI along with a copy on an attached CD or Flash Drive at least two (2) weeks prior to injection to: DWR — UPC Program 1636 Mail Service Center Raleigh, NC 27699-1636 Telephone: (919) 707-9000 Deemed Permitted GW Remediation NOI Rev. 2-14-2020 Page 4 TABLE 1 SUMMARY OF RECENT GROUNDWATER ELEVATION MEASUREMENTS SPEEDWAY NO. 7917 527 WEST MAIN STREET, FOREST CITY, NORTH CAROLINA NCDEQ INCIDENT NO. 23681 ATC ASSOCIATES OF NORTH CAROLINA, P.C. PROJECT NO. SWDP791714 Well ID Number Date Total Well Depth (ft) Screen Interval (ft) Top of Casing Elevation (ft) Depth to Free Product (ft btoc) Depth to Groundwater (ft btoc) Free Product Thickness (ft) Groundwater Elevation (ft) Notes MW-01R 02/27/19 32 22-32 1029.02 --- 23.07 --- 1,005.95 10/13/20 --- 20.94 --- 1,008.08 MW-02 02/27/19 34.5 19.5-34.5 1028.88 --- 23.30 --- 1,005.58 10/13/20 --- 20.81 --- 1,008.07 MW-03R 02/27/19 32 22-32 1028.61 --- 24.48 --- 1004.13 10/13/20 --- 21.97 --- 1006.64 MW-04 02/27/19 40 20-40 1030.23 --- 24.80 --- 1005.43 10/13/20 --- 22.13 --- 1008.10 MW-05 02/27/19 35 20-35 1028.57 --- NM --- --- Not Located 10/13/20 --- 20.70 --- 1007.87 MW-06 02/27/19 35 20-35 1031.62 --- 28.08 --- 1,003.54 Not Located 10/13/20 --- 23.28 --- 1008.34 MW-07 02/27/19 30 15-30 UNK --- NM --- --- Not Located 10/13/20 --- NM --- --- Not Located MW-08 02/27/19 35 20-35 1031.04 --- 24.00 --- 1007.04 10/13/20 --- 25.59 --- 1005.45 MW-09 02/27/19 30 10-30 UNK --- NM --- --- Not Located 10/13/20 --- NM --- --- Not Located MW-10 02/27/19 30 10-30 1020.12 --- 13.20 --- 1006.92 10/13/20 --- NM --- --- Obstructed MW-11 02/27/19 35 20-35 1029.23 --- 23.22 --- 1,006.01 10/13/20 --- 22.90 --- 1,006.33 MW-12 02/27/19 35 20-35 1030.15 --- 25.88 --- 1004.27 10/13/20 --- 22.18 --- 1007.97 MW-13R 02/27/19 32 22-32 1028.61 --- 22.95 --- 1,005.66 10/13/20 --- 21.16 --- 1,007.45 MW-14 02/27/19 35 20-35 1029.53 --- 30.41 --- 999.12 10/13/20 --- 21.66 --- 1007.87 MW-15 02/27/19 35 20-35 1030.19 --- 24.68 --- 1005.51 10/13/20 --- 22.31 --- 1007.88 VW-01 02/27/19 64 UNK 1030.27 --- 24.57 --- 1,005.70 10/13/20 --- 22.19 --- 1,008.08 RW-01 02/27/19 33 23-33 1029.85 --- 24.38 --- 1005.47 10/13/20 --- 21.93 --- 1007.92 RW-02 02/27/19 33 23-33 1030.06 --- 24.60 --- 1005.46 10/13/20 --- 22.10 --- 1007.96 NOTES: TOC ft btoc NM = Top Of Well Casing = Feet below top of well casing = Not detected = With free product present, the following formula was used to calculate the groundwater elevation: Groundwater Elevation = Actual Water Level Meaurement + ( Product Thickness x 0.73) = Water level Not Measured = Pre MMPE Water Level = Post MMPE Water Level Speedway No. 7917 FIGURES June 30, 2021 -.........TTJ ATC An Atlas Company Bus 74 0 Fraternal Order Ea.1esyLatke EHELER,RD NORTH CAROLINA Latitude: N 35' 20' 22.5" Longitude: W 81' 52' 36.9" OLD WADY 0 1/2 / _Gy R� 0VC) J8EW ST LOCATION 1 MILE 0 1000 2000 4000 6000 FEET USGS 7.5—Minute Topographic Nap; Rutherfordton South, NC Quadrangle 2013; Scale: 1:24,000 FORE Hi RlV'fRHICCSip BOB-RO V4LLEYVIEW Di .1 ...Speedway7917—SLM.dwg 'WATC ASSOCIATES OF NORTH CAROLINA, P.C. CHARLOTTE, NORTH CAROLINA 28217 PHONE: (704) 529-3200 FAX: (704) 529-3272 DATE: 5/8/19 DRAWN BY: l SBM J REVIEWED BY: BB 1" = 2000' PROJECT NO.: 1 SWDP791712 J SCALE: ) FIGURE 1� f SITE LOCATION MAP SPEEDWAY LLC STORE No. 7917 (NCDEQ FACILITY ID 23681) 523 WEST MAIN STREET FOREST CITY, RUTHERFORD COUNTY, NORTH CAROLINA SURVEY — JAY S. JOSHI PLS August 10, 2020 CC 06\28\2021 10:37am — Admin — H:A 125 — ATC\ 1254479p1-06-25-21.dwg MW-07 (NOT LOCATED) ASPHALT MW-09 FORMER SITE FEATURES 0 FORMER UST 0 FORMER DISPENSER ISLAND 0 FORMER PRODUCT LINES COMMERCIAL BUILDING • MW-05 C / J MW-1 3R, MW-13zikj / / 0 / MWT02 // f". `O/ • 'll 1 E©7 J20 MW-01 R A • TMW-01 Of \ 0( VW— MW-114 MW-03 ®MW-15 41416) SPHALT 0 I 7 4\16)N. STORE No. 7917 MW-08 0c ♦� \ De ♦ \ De r��Rogo �♦ � cis cyq� FF`♦ \0 BMW-04 05 0.TMW-03 WE -sr MW-03R DISPENSER & CANOPY AREA MW-10 (OBSTRUCTED) • TMW-02 SrREEr o' 0( o' ASPHALT q,MW-06 GAS 0 20 i 40 i SCALE IN FEET \ 0c \ 0� \0e � LEGEND — — — PROPERTY BOUNDARY LINE DE UE GAS G OVERHEAD ELECTRIC LINE UNDERGROUND ELECTRIC LINE NATURAL GAS LINE MONITORING WELL (TYPE II) MONITORING WELL (TYPE III)(DEEP) RECOVERY WELL DESTROYED MONITORING WELL PROPOSED INJECTION POINT 80 PROJECT NO. SWDP791714 w 0 06-25-2021 0 w CO II (NCDEQ FACILITY ID No. 23681) 1 0' 1 NORTH CAROLINA CC LL CC Lil CC uJ Li m LU CO TYPE CODE w L 0 1254479.dwg w cIfi z SURVEY — JAY S. JOSHI PLS August 10, 2020 CC 0 12/02/2020 10.11am — Steve Thompson — H:A 125 — ATC\ 1254479p1-12-01-20.dwg MW-07 ASPHALT / MW-05 (1007.87) COMMERCIAL BUILDING MW-13R (1007.45) ` M09I \• I FORMER SITE FEATURES 0 FORMER UST 0 FORMER DISPENSER ISLAND 0 FORMER PRODUCT LINES / / / / / / / 1 1 ( TMW-01 Oc 0( VW-01 • TMW-03 0 RW-01 14/E-s (1007.92) % MW-02 1008.07 MW-01 R (1008.08) (1008.08) s • TMW-02 0( ASPHALT RW-02 (1007.96 MW-03R MAIN BMW-04 (1008.10) MW-00 (1005.45) \ 0e • `F �c,et>F •` • MW-10 0 20 40 80 SCALE IN FEET \ 0c \ 0� \0E � MW-06 (1008.34) • 00� LEGEND — — — PROPERTY BOUNDARY LINE DE UE GAS GAS • G "• 1008 (1006.33) OVERHEAD ELECTRIC LINE UNDERGROUND ELECTRIC LINE NATURAL GAS LINE MONITORING WELL (TYPE II) MONITORING WELL (TYPE III)(DEEP) RECOVERY WELL DESTROYED MONITORING WELL GROUNDWATER ELEVATION CONTOUR (ft,) GROUNDWATER ELEVATION (ft.) INFERRED GROUNDWATER FLOW DIRECTION PROJECT NO. SWDP791714 w 0 1 2-01 -2020 0 w co c II (NCDEQ FACILITY ID No. 23681) TITLE FIGURE 3 POTENTIOMETRIC SURFACE MAP 0 z >- O w w 0 C/) NORTH CAROLINA U CC Li CC LLJ CC U w Li TYPE CODE w L 0 1254479.dwg w 0 z SURVEY — JAY S. JOSHI PLS August 10, 2020 CC CC 0 06\30\2021 11:49am — Admin — H:A 125 — ATC\ 1254479p1-06-25-21.dwg MW-07 (NOT LOCATED) ASPHALT COMMERCIAL BUILDING / / / MW— \ A FORMER SITE FEATURES 0 FORMER UST 0 FORMER DISPENSER ISLAND 0 FORMER PRODUCT LINES • MW-05 1 U/ MW-1 3R,, MW-13 i 0 /7MWT02 L0 /�L MW-01 '%1W-01 R A / / / / / / / • TMW-01 VW- 40- MW-14 MW— '10 • MW-08 / B' 0.TMW-03 MW-03R / \ �, \W-12/ 6 MW-10 (OBSTRUCTED) / • TMW-02 WEST BMW-04 SER & AREA / \ \ / / \ UE MW-1 1 .- STREET v`F ASPHALT q,MW-06 GAS 0 20 40 SCALE IN FEET � oc \ OC \oe � LEGEND — — — PROPERTY BOUNDARY LINE DE UE GAS G OVERHEAD ELECTRIC LINE UNDERGROUND ELECTRIC LINE NATURAL GAS LINE MONITORING WELL (TYPE II) MONITORING WELL (TYPE III)(DEEP) RECOVERY WELL DESTROYED MONITORING WELL PROPOSED INJECTION POINT 80i PROJECT NO. SWDP791714 w 0 06-25-2021 0 w II co (NCDEQ FACILITY ID No. 23681) TITLE FIGURE 4 TRANSECT MAP 6' 0 z SPEEDWAY NORTH CAROLINA CC LL CC w CC 1-1 w oo > CO Lu CO TYPE CODE 0 1254479.dwg w 0 z CANOPY DISPENSER 1040.00' 1030.00' 1020.00' 1010.00' 1000.00' 990.00' 1-06-25-21.d A MW-09 (NA) BROWNISH RED SILT MW-1 5 (1030.19') rr/ 0/7 we rry/ r/r/r INJECTION POINTS BROWNISH RED SILT RW-01 (1029.85') A' LEGEND 7 BROWNISH RED SILT WATER TABLE DMW-3 �WELL IDENTIFICATION (98.22') TOP OF CASING WELL CASING WELL SCREEN SCALES: VERTICAL SCALE: 1" = 10' HORIZONTAL SCALE: 1 " = 20' (NCDEQ FACILITY ID No. 23681) TITLE FIGURE 5 GEOLOGIC CROSS-SECTION A -A' C 0 >- 0 w w 0L U) w w z w LC) CC CC CC Li CC W CC U co w LL 0) w 0 z PROJECT NO. SWDP791714 06-25-2021 021 m m S w a 0 w O 0 0 d w 0 O 1254479.dwg 1040.00' 1030.00' 1020.00' 101 0.00' 1000.00' 990.00' 06\30\2021 11:48am — Admin — H:A125 — ATC\ 1254479x51-06-25-21.dwg B MW-08 (1031.04') BROWNISH RED SILT //• BROWNISH RED SILT B' MW-03R (1028.61') RW-02 RW-01 (1030.06') (1029.85') BROWNISH RED SILT r/r LEGEND BROWNISH RED SILT WATER TABLE DMW-3 ' WELL IDENTIFICATION (98.22') ®� TOP OF CASING WELL CASING WELL SCREEN SCALES: VERTICAL SCALE: 1" = 10' HORIZONTAL SCALE: 1" = 20' PROJECT NO. SWDP791714 uJ 0 0 06-25-2021 w 0 U 0 z (NCDEQ FACILITY ID No. 23681) TITLE FIGURE 6 m CO GEOLOGIC CROSS-SECTION w w cc C3' U) o Q >- 0 WI 3 w w cY) OL CV Cn LC) NORTH CAROLINA CC LL CC w CC U cf.) w cc Li TYPE CODE w O O U 1254479.dwg 0) w 0 z VW-01 RW-01 peedway7916-03.dwg MW-02 3/28/18 2/27/19 B 1 6.091 I 20.11 T 2.82 <1 E 146 11 X 21.4 <3 MTBE 26.7 1 1581 N 70.1 <5 1,2—DCA <2 <1 IPE <2 2.58 MW-13R 3/28/18 2/27/19 B <1 T <1 E <1 X <3 MTBE 6.00 N <5 1,2—DCA <1 IPE <1 MW-15 3/28/18 2/27/19 B r 6860 2060 T 3370 46.9 E 1490 1 11801 X 6800 436 MTBE 1280 665 N <1000 174 1,2—DCA <200 <25 IPE <200 I 1311 MW-07 MW-07 3/28/18 2/27/19 B NOT NOT T SAMPLED; SAMPLED; E TA NOT X REQUESTED LOCATED MTBE NO N SAMPLE 1,2—DCA IPE MW-09 3/28/18 2/27/19 B NOT NOT T SAMPLED; SAMPLED; E TA NOT X REQUESTED LOCATED MTBE NO N SAMPLE 1,2—DCA IPE MW-05 3/28/18 2/27/19 B <1 NOT T <1 SAMPLED; E <1 DAMAGED X <3 WELL MTBE 1 21.61 N <5 1,2—DCA <1 IPE <1 MW-01R COMMERCIAL UILDING 3/28/18 2/27/19 B 565 274 T 1410 424 E 215 222 X 2200 1570 MTBE 40.2 34.5 N <125 <125 1,2—DCA <25 <25 IPE <25 <25 • MW-09 I 1 \ 1 MW-08 3/28/18 2/27/19 B NOT <1 T SAMPLED; <1 E TA <1 X REQUESTED <3 MTBE NO <1 N SAMPLE <5 1,2—DCA <1 IPE <1 MW-14 3/28/18 2/27/19 B 1 12901 I 641 T 57.4 306 E 125 284 X 403 1190 MTBE 232 167 N 141 <125 1,2—DCA <25 <25 IPE 43.3 33.2 MW-05 UNIT No. 228 AS/SVE SYSTEM MW-10 TMW-01 0 MW-140 3/28/18 2/27/19 B NOT T SAMPLED; E TA X REQUESTED MTBE NO N SAMPLE 1,2—DCA IPE <1 <1 <1 <3 <1 <5 <1 <1 3/28/18 2/27/19 B <1 <1 T <1 <1 E <1 <1 X <3 <3 MTBE 1 22.81 1 20.4 N <5 <5 1,2—DCA <1 <1 IPE 2.46 1.75 L_ RW-01 vw 01 MW-03 MW-08 F\ 4MW-10 ®MW-03 3/28/18 2/27/19 B 3950 1 82601 T 2580 2000 E 823 1220 X 7020 4920 MTBE 958 14501 N <1000 <500 1,2—DCA <200 <100 IPE <200 1 1391 MW-04 MW-03R 3/28/18 2/27/19 B -1 1 156001 T 18100 12400 E Iligall 1770 X ii 13200 MTBE 1900 21301 N <2500 <2500 1,2—DCA <500 <500 IPE <500 <500 ®TMW-02 ASPHALT UST AREA oZ / MW-11 MW-12 3/28/18 2/27/19 B I 33001 I 48401 T 85 59.7 E 968 I 8361 X 214 <150 MTBE 552 I 5301 N <250 <250 1,2—DCA <50 <50 IPE 65.8 66.7 RW-02 3/28/18 2/27/19 B I 140001 1 18300 T 17000 16500 E 2130 2250 X 14600 13900 MTBE 19501 1 2440 N <2500 <2500 1,2—DCA <500 <500 IPE <500 <500 MW-06 3/28/18 2/27/19 B NOT AAAAAAAA T SAMPLED; E TA X REQUESTED MTBE NO N SAMPLE 1,2—DCA IPE MW-04 3/28/18 2/27/19 B NOT <1 T SAMPLED; <1 E TA <1 X REQUESTED <3 MTBE NO <1 N SAMPLE <5 1,2—DCA <1 IPE <1 3/28/18 2/27/19 B NOT AA A AAA T SAMPLED; E TA X REQUESTED MTBE NO N SAMPLE 1,2—DCA IPE Nfl// VT4_ ASSOCIATES OF NORTH CAROLINA, P.C. CHARLOTTE, NORTH CAROLINA 28217 PHONE: (704) 529-3200 FAX: (704) 529-3272 l DATE: 5/8/19 ) DRAWN BY: 1 SBM J REVIEWED BY: 1 BB J / / / / PROJECT NO.: 1 SWDP791712 J SCALE: 1"=40' ) FIGURE 7J SCALE IN FEET LEGEND: — — — — PROPERTY LINE MONITORING WELL 0 DESTROYED MONITORING WELL CONCENTRATIONS IN ppb (ug/L) SAMPLE DATE B T X MTBE N 1,2—DCA IPE BENZENE TOLUENE ETHYLBENZENE XYLENES METHYL —TERTIARY —BUTYL —ETHER NAPHTHALENE 1,2—DICHLOROETHANE ISOPROPYL ETHER ITALIC/ZED I BOLD VALUE EXCEEDS 2L STANDARD VALUE EXCEEDS 10X 2B STANDARD VALUE EXCEEDS GCL (NA) NOT ANALYZED FORMER SITE FEATURES: 0 FORMER UST O2 FORMER DISPENSER ISLAND ©3 FORMER PRODUCT LINES CONCENTRATIONS OF PETROLEUM CONSTITUENTS MAP MARCH 28, 2018 & FEBRUARY 27, 2019 SPEEDWAY LLC STORE No. 7917 (NCDEQ FACILITY ID 23681) 523 WEST MAIN STREET FOREST CITY, RUTHERFORD COUNTY, NORTH CAROLINA Speedway No. 7917 APPENDIX A SDS FORM June 30, 2021 SAFETY DATA SHEET KLOZUR® CR SDS # : 7775-27-1-2 Revision date: 2015-05-01 Format: NA Version 1 PeroxyChem 1. PRODUCT AND COMPANY IDENTIFICATION Product Identifier Product Name Other means of identification KLOZUR® CR Recommended use of the chemical and restrictions on use Recommended Use: In situ and ex situ chemical oxidation of contaminants and compounds of concern for environmental remediation applications Restrictions on Use: No uses to be advised against were identified. Manufacturer/Supplier Emergency telephone number PeroxyChem LLC 2005 Market Street Suite 3200 Philadelphia, PA 19103 Phone: +1 267/ 422-2400 (General Information) E-Mail: sdsinfo@peroxychem.com For leak, fire, spill or accident emergencies, call: 1 800 / 424 9300 (CHEMTREC - U.S.A.) 1 703 / 527 3887 (CHEMTREC - Collect - All Other Countries) 1 303/ 389-1409 (Medical - U.S. - Call Collect) 2. HAZARDS IDENTIFICATION Classification OSHA Regulatory Status This material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR 1910.1200). Acute toxicity - Oral Category 4 Skin corrosion/irritation Category 2 Serious eye damage/eye irritation Category 1 Respiratory sensitization Category 1 Skin sensitization Category 1 Specific target organ toxicity (single exposure) Category 3 Oxidizing Solids Category 2 GHS Label elements, including precautionary statements EMERGENCY OVERVIEW Page 1 / 8 KLOZUR® CR SDS # : 7775-27-1-2 Revision date: 2015-05-01 Version 1 Danger Hazard Statements H334 - May cause allergy or asthma symptoms or breathing difficulties if inhaled H335 - May cause respiratory irritation H318 - Causes serious eye damage H315 - Causes skin irritation H317 - May cause an allergic skin reaction H302 - Harmful if swallowed H272 - May intensify fire; oxidizer Precautionary Statements - Prevention P261 - Avoid breathing dust/ fume/ gas/ mist/ vapors/ spray P271 - Use only outdoors or in a well -ventilated area P285 - In case of inadequate ventilation wear respiratory protection P280 - Wear protective gloves/ protective clothing/ eye protection/ face protection P270 - Do not eat, drink or smoke when using this product P264 - Wash face, hands and any exposed skin thoroughly after handling P210 - Keep away from heat/sparks/open flames/hot surfaces. - No smoking P220 - Keep/Store away from clothing/combustible materials P221 - Take any precaution to avoid mixing with combustibles Precautionary Statements - Response P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing P310 - Immediately call a POISON CENTER or doctor P302 + P352 - IF ON SKIN: Wash with plenty of water and soap P333 + P313 - If skin irritation or rash occurs: Get medical advice/ attention P304 + P340 - IF INHALED: Remove person to fresh air and keep comfortable for breathing P301 + P312 - IF SWALLOWED: Call a POISON CENTER or doctor if you feel unwell P370 + P378 - In case of fire: Use water for extinction Precautionary Statements - Storage P403 + P233 - Store in a well -ventilated place. Keep container tightly closed Hazards not otherwise classified (HNOC) No hazards not otherwise classified were identified. Other Information Risk of decomposition by heat or by contact with incompatible materials. Page 2 / 8 KLOZUR® CR SDS # : 7775-27-1-2 Revision date: 2015-05-01 Version 1 3. COMPOSITION/INFORMATION ON INGREDIENTS Chemical name CAS -No Weight % Sodium Persulfate 7775-27-1 40-60 Proprietary ingredient Proprietary 40-60 Calcium Hydroxide 1305-62-0 8 - 12 Synonyms are provided in Section 1. 4. FIRST AID MEASURES General Advice Eye Contact Skin Contact Inhalation Ingestion Most important symptoms and effects, both acute and delayed Indication of immediate medical attention and special treatment needed, if necessary Remove from exposure, lie down. Show this material safety data sheet to the doctor in attendance. Rinse thoroughly with plenty of water for at least 15 minutes, lifting lower and upper eyelids intermittently. Consult a physician. In case of contact, immediately flush eyes with plenty of water. If symptoms persist, call a physician. Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. Get medical attention if irritation develops and persists. Remove from exposure, lie down. If breathing is irregular or stopped, administer artificial respiration. Call a physician immediately. Do NOT induce vomiting. Call a physician or poison control center immediately. Rinse mouth. Drink 1 or 2 glasses of water. Itching; Redness; Coughing and/ or wheezing Treat symptomatically. 5. FIRE -FIGHTING MEASURES Suitable Extinguishing Media Unsuitable extinguishing media Specific Hazards Arising from the Chemical Explosion data Sensitivity to Mechanical Impact Sensitivity to Static Discharge Protective equipment and precautions for firefighters Water. Cool containers with flooding quantities of water until well after fire is out. Do not use carbon dioxide or other gas filled fire extinguishers; they will have little effect on decomposing persulfate. Decomposes under fire conditions to release oxygen that intensifies the fire. Not sensitive. Not sensitive. As in any fire, wear self-contained breathing apparatus pressure -demand, MSHA/NIOSH (approved or equivalent) and full protective gear. 6. ACCIDENTAL RELEASE MEASURES Personal Precautions Other Keep off any unprotected persons. Avoid contact with the skin and the eyes. Avoid breathing dust. Wear personal protective equipment. Never add other substances or combustible waste to product residues. Containers of contaminated waste material should be monitored for signs of decomposition (fuming or smoking). Page 3 / 8 KLOZUR® CR Environmental Precautions Methods for Containment Methods for cleaning up Handling Storage Incompatible products Control parameters Exposure Guidelines SDS # : 7775-27-1-2 Revision date: 2015-05-01 Version 1 Knock down dust with water spray. Avoid penetration into waterways, sewers, soil or groundwater. Local authorities should be advised if significant spillages cannot be contained. Do not return product to the original storage container/tank due to risk of decomposition. Vacuum, shovel or pump waste into a drum and label contents for disposal. Store in closed container. Do not allow material to enter storm or sanitary sewer system. Clean up spill area and treat as special waste. 7. HANDLING AND STORAGE Wear personal protective equipment. Use only in area provided with appropriate exhaust ventilation. Avoid dust formation. Handle product only in closed system or provide appropriate exhaust ventilation at machinery. Avoid contact with skin and eyes. Avoid breathing dust. Remove and wash contaminated clothing before re -use. Reference to other sections. Keep containers tightly closed in a dry, cool and well -ventilated place. Keep away from heat. Do not store near combustible materials. Avoid contamination of opened product. Keep away from food, drink and animal feedingstuffs. Avoid formation and deposition of dust. Acids, Bases, Halides, Oxidizing agents, Strong reducing agents, Combustible materials, 8. EXPOSURE CONTROLS/PERSONAL PROTECTION Chemical name ACGIH TLV OSHA PEL NIOSH Mexico Sodium Persulfate 7775-27-1 TWA: 0.1 mg/m3 - - - Calcium Hydroxide 1305-62-0 TWA: 5 mg/m3 TWA: 15 mg/m3 TWA: 5 mg/m3 TWA: 5 mg/m3 Mexico: TWA 5 mg/m3 Chemical name British Columbia Quebec Ontario TWAEV Alberta Sodium Persulfate 7775-27-1 TWA: 0.1 mg/m3 - TWA: 0.1 mg/m3 TWA: 0.1 mg/m3 Calcium Hydroxide 1305-62-0 TWA: 5 mg/m3 TWA: 5 mg/m3 TWA: 5 mg/m3 TWA: 5 mg/m3 Appropriate engineering controls Engineering measures Ensure adequate ventilation. Individual protection measures, such as personal protective equipment Eye/Face Protection Skin and Body Protection Hand Protection Respiratory Protection Hygiene measures General information Eye protection recommended: Tightly fitting safety goggles. Wear suitable protective clothing. Protective shoes or boots. Protective gloves: Neoprene gloves, Polyvinylchloride, Natural Rubber Use only with adequate ventilation. Respirator must be worn if exposed to dust. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Wash hands before breaks and after shifts. Keep work clothes separate, remove contaminated clothing - launder after open handling of product. Protective engineering solutions should be implemented and in use before personal protective equipment is considered. Page 4 / 8 KLOZUR® CR SDS # : 7775-27-1-2 Revision date: 2015-05-01 Version 1 9. PHYSICAL AND CHEMICAL PROPERTIES Information on basic physical and chemical properties Appearance Physical State Color Odor Odor threshold pH Melting point/freezing point Boiling Point/Range Flash point Evaporation Rate Flammability (solid, gas) Flammability Limit in Air Upper flammability limit: Lower flammability limit: Vapor pressure Vapor density Density Specific gravity Water solubility Solubility in other solvents Partition coefficient Autoignition temperature Decomposition temperature Viscosity, kinematic Viscosity, dynamic Explosive properties Oxidizing properties Molecular weight Bulk density Fine granules Solid Off-white odorless Not applicable 11.2 (1% solution) Decomposes No information available Not applicable No information available Not flammable Not applicable No information available No information available No information available 1.0 - 1.19 (5 to 30% slurries) slightly soluble No information available No information available (inorganic) Product is not self -ignitable. > 100 °C (assume) No information available No information available Not explosive oxidizer No information available 51.8 Ib/cu ft (loose) 10. STABILITY AND REACTIVITY Reactivity Chemical Stability Possibility of Hazardous Reactions Hazardous polymerization Conditions to avoid Incompatible materials Strong oxidizer. Stable under recommended storage conditions. Use of persulfates in chemical reactions requires appropriate precautions and design considerations for pressure and thermal relief. Decomposing persulfates will evolve large volumes of gas and/or vapor, can accelerate exponentially with heat generation, and create significant and hazardous pressures if contained and not properly controlled or mitigated. Use with alcohols in the presence of water has been demonstrated to generate conditions that require rigorous adherence to process safety methods and standards to prevent escalation to an uncontrolled reaction. Hazardous polymerization does not occur. Heat (decomposes at temperatures >100 °C); Moisture Acids, Bases, Halides, Oxidizing agents, Strong reducing agents, Combustible materials, Hazardous Decomposition Products None known based on information supplied. 11. TOXICOLOGICAL INFORMATION Product Information Page 5 / 8 KLOZUR® CR Proprietary ingredient and calcium hydroxide are not classified for acute toxicity LD50 Oral LD50 Dermal LC50 Inhalation SDS # : 7775-27-1-2 Revision date: 2015-05-01 Version 1 No data available for the formulation. 895 mg/kg (rat) Sodium Persulfate No data available for the formulation. > 10,000 mg/kg (rabbit) Sodium Persulfate No data available for the formulation. = > 5.1 mg/L (4-hr) (rat) Sodium Persulfate Sensitization Sensitizing to skin and respiratory system. Positive in a local lymph node assay. (based on components). Information on toxicological effects Symptoms Dust is irritating eyes, nose, throat, and lungs. Delayed and immediate effects as well as chronic effects from short and long-term exposure Carcinogenicity Not recognized as carcinogenic by Research Agencies (IARC, NTP, OSHA, ACGIH). Mutagenicity This product is not recognized as mutagenic by Research Agencies Reproductive toxicity This product is not recognized as reprotox by Research Agencies. STOT - single exposure May cause respiratory irritation. STOT - repeated exposure No information available. Target organ effects Aspiration hazard Eyes, Skin, Respiratory System. No information available. 12. ECOLOGICAL INFORMATION Ecotoxicity Ecotoxicity effects Sodium Persulfate (7775-27-1) Active Ingredient(s) Duration Species Value Units Sodium Persulfate 96 h LC50 Rainbow trout 163 mg/L Sodium Persulfate 48 h LC50 Daphnia magna 133 mg/L Sodium Persulfate 96 h LC50 Grass shrimp 519 mg/L Sodium Persulfate 72 h EC50 Algae Selenastrum capricornutum 116 mg/L Persistence and degradability Biodegradability does not pertain to inorganic substances. Bioaccumulation Does not bioaccumulate. Mobility Dissociates into ions. Other Adverse Effects None known. 13. DISPOSAL CONSIDERATIONS Waste disposal methods This material, as supplied, is a hazardous waste according to federal regulations (40 CFR 261). It must undergo special treatment, e.g. at suitable disposal site, to comply with local Page 6 / 8 KLOZUR® CR US EPA Waste Number Contaminated Packaging regulations. Containers of contaminated waste decomposition (fuming or smoking). D001 SDS # : 7775-27-1-2 Revision date: 2015-05-01 Version 1 material should be monitored for signs of Dispose of in accordance with local regulations. 14. TRANSPORT INFORMATION DOT UN/ID no Proper Shipping Name Hazard class Packing Group Reportable Quantity (RQ) TDG UN/ID no Proper Shipping Name Hazard class Packing Group ICAO/IATA UN/ID no Proper Shipping Name Hazard class Packing Group IMDG/IMO UN/ID no Proper Shipping Name Hazard class Packing Group UN 1479 OXIDIZING SOLID N.O.S. (sodium persulfate, calcium peroxide) 5.1 (Oxidizer) I I not applicable UN 1479 OXIDIZING SOLID N.O.S. (sodium persulfate, calcium peroxide) 5.1 I I UN 1479 OXIDIZING SOLID N.O.S. (sodium persulfate, calcium peroxide) 5.1 I I UN 1479 OXIDIZING SOLID N.O.S. (sodium persulfate, calcium peroxide) 5.1 I I 15. REGULATORY INFORMATION U.S. Federal Regulations SARA 313 Section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 (SARA). This product does not contain any chemicals which are subject to the reporting requirements of the Act and Title 40 of the Code of Federal Regulations, Part 372 SARA 311/312 Hazard Categories Acute health hazard Chronic health hazard Fire hazard Sudden release of pressure hazard Reactive Hazard Yes No Yes No No Clean Water Act This product does not contain any substances regulated as pollutants pursuant to the Clean Water Act (40 CFR 122.21 and 40 CFR 122.42) CERCLA This material, as supplied, does not contain any substances regulated as hazardous substances under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA) (40 CFR 302) or the Superfund Amendments and Reauthorization Act (SARA) (40 CFR 355). There may be specific reporting requirements at the local, regional, or state level pertaining to releases of this material Page 7 / 8 KLOZUR® CR SDS # : 7775-27-1-2 Revision date: 2015-05-01 Version 1 International Inventories Component TSCA (United States) DSL (Canada) EINECS/EL INCS (Europe) ENCS (Japan) China (IECSC) KECL (Korea) PICCS (Philippines ) AICS (Australia) NZIoC (New Zealand) Sodium Persulfate 7775-27-1 (40-60 X X X X X X X X X Trade secret ( 40-60 ) X X X X X X X X X Calcium Hydroxide 1305-62-0 ( 8 - 12 X X X X X X X X X CANADA WHMIS Hazard Class C - Oxidizing materials D2A - Very toxic materials D2B - Toxic materials E - Corrosive material 16. OTHER INFORMATION NFPA Health Hazards 2 Flammability 0 Stability 1 Special Hazards OX HMIS Health Hazards 2 Flammability 0 Physical hazard 0 Special precautions J NFPA/HMIS Ratings Legend Revision date: Revision note Severe = 4; Serious = 3; Moderate = 2; Slight = 1; Minimal = 0 Protection=J (Safety goggles, gloves, apron, combination dust and vapor respirator) 2015-05-01 Initial Release Disclaimer PeroxyChem believes that the information and recommendations contained herein (including data and statements) are accurate as of the date hereof. NO WARRANTY OF FITNESS FOR ANY PARTICULAR PURPOSE, WARRANTY OF MERCHANTABILITY OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, IS MADE CONCERNING THE INFORMATION PROVIDED HEREIN. The information provided herein relates only to the specified product designated and may not be applicable where such product is used in combination with any other materials or in any process. Further, since the conditions and methods of use are beyond the control of PeroxyChem, PeroxyChem expressly disclaims any and all liability as to any results obtained or arising from any use of the products or reliance on such information. Prepared By: PeroxyChem © 2015 PeroxyChem. All Rights Reserved. End of Safety Data Sheet Page 8 / 8 Speedway No. 7917 APPENDIX B MONITORING WELL CONSTRUCTION June 30, 2021 EXISTING SURFACE 8"0 MANBOX (12" MIN. DEPTH) CONCRETE PAD (24"x24"x12") (SEE NOTES 1 & 2) EXTEND GROUT/BENTONITE TWO INCHES INTO MANBOX 2"0 SCH. 40 PVC; FLUSH THREADED; 5'-10' LENGTH GROUT/BENTONITE 2' BENTONITE PELLET SEAL SAND PACK 2"0 SCH. 40 PVC; FLUSH THREADED; CONTINUOUS WRAP; 0.010" OPENINGS; 10' LENGTH 8" BORING; TOTAL DEPTH 15'-20' NOTES: 1. SLOPE CONCRETE AWAY FROM MANBOX. 2. USE QUIKCRETE® COMMERCIAL GRADE FASTSETT"" DOT MIX EXTENDED (#1244-81) OR EQUAL. 3. SCREEN SLOT OPENING, SCREEN, AND RISER LENGTHS MAY VARY BASED ON INDIVIDUAL WELL AND STATE REGULATIONS. 4. STATE REGULATIONS MAY REQUIRE ALTERATIONS TO THIS STANDARD WELL CONSTRUCTION DETAIL. DISCUSS WITH YOUR LOCAL SPEEDWAY ENVIRONMENTAL REPRESENTATIVE. WELL STANDARD CONSTRUCTION DETAIL 5/18/17 NO. RENSIONS N OAIE� Pfl T. NM. DATE fl0AIR Speedway Speedway Prepared By: Speedway Environmental Department 600 Speedway Drive Enon, OH 45323 GEOGNED MAS GELAJL® SBM TYPICAL 2" WELL CROSS SECTION TRAFFIC AREAS aEa® BCD QiENTILOCATIGN: SPEEDWAY, LLC FIGURE 1 This drawing is the property of Speedway and is not to be used or reproduced without expressed written consent o Speedway. EXISTING SURFACE CONCRETE PAD (24"x24"x8") (SEE NOTES 1 & 2) 4" DOT 304 BASE (OR EQUIVALENT) 2"0 SCH. 40 PVC; FLUSH THREADED; 5'-10' LENGTH GROUT/BENTONITE 2' BENTONITE PELLET SEAL SAND PACK 2"0 SCH. 40 PVC; FLUSH THREADED; CONTINUOUS WRAP; 0.010" OPENINGS; 10' LENGTH 8" BORING; TOTAL DEPTH 15'-20' 8"0 MANBOX (12" MIN. DEPTH) EXTEND GROUT/BENTONITE TWO INCHES INTO MANBOX NOTES: 1. SLOPE CONCRETE AWAY FROM MANBOX. 2. USE QUIKCRETE® COMMERCIAL GRADE FASTSETT"" DOT MIX EXTENDED (#1244-81) OR EQUAL. 3. SCREEN SLOT OPENING, SCREEN, AND RISER LENGTHS MAY VARY BASED ON INDIVIDUAL WELL AND STATE REGULATIONS. 4. STATE REGULATIONS MAY REQUIRE ALTERATIONS TO THIS STANDARD WELL CONSTRUCTION DETAIL. DISCUSS WITH YOUR LOCAL SPEEDWAY ENVIRONMENTAL REPRESENTATIVE. WELL STANDARD CONSTRUCTION DETAIL 5/18/17 NO. RENSIONS N OAIE� Pfl T. NM. DATE fl0AIR Speedway Speedway Prepared By: Speedway Environmental Department 600 Speedway Drive Enon, OH 45323 GEOGNED MAS GELAJL® SBM TYPICAL 2" WELL CROSS SECTION NON -TRAFFIC AREAS aEa® BCD QiENTILOCATIGN: SPEEDWAY, LLC FIGURE 1 This drawing is the property of Speedway and is not to be used or reproduced without expressed written consent o Speedway.