HomeMy WebLinkAboutGW1-2021-00909_Well Construction - GW1_20210402 WELL CONSTRUCTION RECORD(GW-1) For Internal Use Only:
1.Well Contractor Information:
Jon Keifer 14.WATER ZONES
FROM TO DESCRIPTION
Well Contractor Name ft. ft.
NCWC 4097-A ft. ft.
NC Well Contractor Certification Number 15.OUTER CASING for multi-cased wells OR LINER if a livable
Landprobe, Dept. of Bunnell Lammons Eng., Inc. FROM To DIAMETER THICIwFss MATERIAL
ft. ft. in.
Company Name
WI0300435 16.INNER CASING ORTUBnvG eothermalchssed-loo
2.Well Construction Permit#: FROM TO DIAMETER THICKNESS MATERIAL
List all applicable well construction permits(i.e.U1C,County,State, Variance,etc) 0 ft• 45 ft- 611 m SChd 80 PVC
3.Well Use(check well use): ft. ft.17.
in
Water Supply Well: FROMREE TO DIAMETER ' SLOT SIZE THICKNESS MATERIAL
❑Agricultural ❑Municipal/Public 45 ft. 70 ft' 6" 1O .010 SChd 80 SS 304
❑Geothermal(Heating/Cooling Supply) ❑Residential Water Supply(single) k• 45 ft. in.
❑Industrial/Commercial ❑Residential Water Supply(shared) I&GROUT
❑Irrl ation ❑Wells>100000 GPD FROM I TO MATERIAL EMPLACEMENT M ETHOD&AMOUNT
Non-Water Supply Well: 0 ft 39 ft- Neat Grout Tremie 150 Gallons
❑Monitoring ❑Recovery ft. ft.
Injection Well:
ft. ft.
❑Aquifer Recharge InGroundwater Remediation
19.SAND/GRAVEL PACK if applicable)
❑Aquifer Storage and Recovery ❑Salinity Barrier FROM TO MATERIAL EMPLACEMENT METHOD
❑Aquifer Test ❑Stormwater Drainage 39 fr 43 ft #1 Choker Sand ITremie
❑Experimental Technology ❑Subsidence Control 43 ft' 72 ft- #2 Filter Sand JTremie
❑Geothermal(Closed Loop) ❑Tracer 20.DRILLING LOG attach additional sheets if necessary)
❑Geothermal(Heating/Cooling Return) ❑Other(explain under#21 Remarks) FROM I TO DESCRIPTION color,hardness,soittrock type,grain size,etc.
0 ft 10 ft- Not logged-Vacuum Utility Clearance
4.Date Wcll(s)Completed: 03/31/21 Well tD# I W-45 10 ft• 20 ft- No Recovery
Sa.Well Location: 20 ft• 67 ft. Sift
Allen Steam/Duke Energy N/A 67 ft• 74.5 ft- Bedrock ..
Facility/Owner Name Facility ID#(if applicable) ft. ft. ra•
253 Plant Allen Road, Belmont, NC 28012 ft. ft.
Physical Address,City,and Zip ft. ft.
APR U 'Lull
Gaston 3592779998 21.REMARKS
County Parcel Identification No.(PIN)
5b.Latitude and longitude in degrees/minutes/seconds or decimal degrees:
(if well field,one lat/long is sufficient) 22.Certification:
529601.4 N 1400191 Easting w Jon Keifer Jon 20211--03-3116:01:52 3/31/2021
6.Is(are)the well(s): [!]Permanent or ❑Temporary Signature of Certified Well Contractor Date
By signing this form,/hereby certify that the well(s)was(were)constructed in accordance with
7.Is this a repair to an existing well: ❑Yes or IINo 15A NCAC 02C.0100 or 15A NCAC 02C.0200 Well Construction Standards and that a copy
Ifthis is a repair,fill out known well construction information and explain the nature of the ofthis record has been provided to the well owner.
repair under#21 remarks section or on the back of this form.
23.Site diagram or additional well details:
8.For Geoprobe/DPT or Closed-Loop Geothermal Wells having the same You may use the back of this page'to provide additional well construction info
construction,only 1 GW-1 is needed. Indicate TOTAL NUMBER of wells (add'See Ovee in Remarks Box).You may also attach additional pages if necessary.
drilled: 24.SUBMITTAL INSTRUCTIONS
9.Total well depth below land surface: 74.5 (ft)
For multiple wells list all depths trdifferent(example-3 a 00'and 2@100) Submit this GW-1 within 30 days of well completion per the following:
24a. For All Wells: Original form to Division of Water Resources (DWR),
10.Static water level below top of casing: (ft) Information Processing Unit,1617 MSC,Raleigh,NC 27699-1617
/fsvater level is above casing,use"+"
11.Borehole diameter: 10 (in.) 24b.For Injection Wells:Copy to DWR,Underground Injection Control(IUC)
Program,1636 MSC,Raleigh,NC 27699-1636
12.Well construction method: ��ta'J�/ 24c.For Water Supply and Open-Loop Geothermal Return Wells:Copy to the
(i.e.auger,rotary,cable,direct push,etc.) county environmental health department of the county where installed
FOR WATER SUPPLY WELLS ONLY: 24d.For Water Wells producing over 100,000 GPD:Copy to DWR,CCPCUA
13a.Yield(gpm) Method of test: Permit Program,1611 MSC,Raleigh,NC 27699-16 1 1
13b.Disinfection type: Amount:
i
Form GW-1 North Carolina Department of Environmental Quality-Division of Water Resources Revised 6-6-2018