Loading...
HomeMy WebLinkAboutWQ0022908_Regional Office Historical File Pre 2018/94 Michael F. Easley, Governor William G. Ross Jr., Secretary r North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality Coleen. H. Sullins, Deputy Director Division of Water Quality August 01, 2003 Mr. Paul Neff, Corporate Secretary River Run Utility Company, Inc. 18608 River Ford Drive Davidson, North Carolina 28036 Subject: Permit No. WQ0022908 River Run Utility Company, Inc. Extension to serve Saddle Oaks Drive Wastewater Collection System Extension Mecklenburg County Dear Mr. Neff: In accordance with your application received on July 11, 2003, we are forwarding herewith Permit No. WQ0022908, dated August 01, 2003, to River Run Utility Company, Inc. for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. it shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office Internet http://h2o.enr.state.nc.usl 919 N. Main Street, Mooresville, NC 28115 Telephone (704) 663-1699 Fax (704) 663-6040 NCDENR DENR Customer Service Center Telephone 1 877 623-6748 Mr. Paul Neff Page 2 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to River Run Utility Company, Inc. for the construction and operation of approximately 581 linear feet of 8-inch gravity sewer to serve 5 residential units as part of the Extension to serve Saddle Oaks Drive project, and the discharge 1,800 gallons per day of collected domestic wastewater into the River Run WVVTP (NPDES No. NC0067920) existing sewerage system, pursuant to the application received July 11, 2003 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. if you need additional information concerning this matter, please contact Sonja Williams at (704) 663-1699. Sincerely, D. G for Alan W. Klimek, P.E. cc: Mecklenburg County Health Department Mecklenburg County Department of Environmental Protection Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0067920) Riley Burgess, Environmental Design, PA Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permiee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shalt be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10_ The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B -.0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H _0500. rrincompliance Notification: The Permittee shall report by telephone to the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 1st day of August, 2003. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Kli , P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WO0022908 Fast Track Engineering Certification Permit No. WQ0022908 August 01, 2003 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial El Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ['weekly, ❑ full time) the construction of the Extension to serve Saddle Oaks Drive, Mecklenburg County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. ck APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 1 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by QWQ) W a AOZZ90e I. Owner: - la. River Run Utility Company, Inc. Full Legal Name (company, municipality, HOA, utility, etc.) Ib. Paul F. Neff, Corporate Secretary • Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) 1c. The • legal entity Individual, who will own this system is: ■ Federal 0 Municipality ❑ State/County ■ Private Partnership ® Corporation ■ Other (specify): - Id. 18608 River Ford Drive' le. Davidson - • LL Street Address City Z 1f. North Carolina lg. 28036 Z State Zip Code O lh. 704-896-8811 11. 704-896-8683 1 j. - Telephone Facsimile E-mail t) 2. Project (Facility) Information: a2a. Extension to serve Saddle Oaks Drive b. Mecklenburg a Brief Project Name (permit will refer to this name) County Where Project is Located < 3. Contact Person: Q 3a. Riley D. Burgess, Jr., PE Engineer of Record Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-896-8020 3c. r.burgess@edpa.net Phone Number E-mail 1. Project is ► o New 0 Modification (of an existing permit) If Modification, Permit No.: 2. Owner is ® Public (skip to Item B(3)) • Private (go to Item 2(a)) If private, applicant will be: - 2b. If sold, facilities owned by a (must choose one) 12a. _ I • • 0 Retaining Ownership (i.e. store, church, single office, etc.) Leasing units (lots, townhomes, etc. - skip to Item B(3)) Selling units (lots, townhomes, etc. - go to Item B(2b)) • Public Utility (Instruction III) 0 Homeowner Assoc./Developer (Instruction IV) p0' 3. River Run Utility Company, Inc. f Owner of Wastewater Treatment Facilit y ty (V11WTF) Treating Wastewater From This Project. < 4a. River Run WWTP 4b. NC 0067920 1 Name of WWTF WWTF Permit No. 0 5a. River Run Utility Company, inc. 5b. 8-inch 5c. WQ 0001807 :LLZ' Owner of Downstream Sewer Receiving Sewer Size Permit Number of Downstream Sewer r H• 6. The origin of this wastewater is (check all that apply): M' ' _ W :. �" . ® Residential Subdivision D Apartments/Condominiums 0 Mobile Home Park El School • Car Wash ■ Institution 0 Hospital El Church 100 % DomesticlCommercial % Industrial 0 Restaurant Office ❑ Nursing Home % Other (specify): • ; x' ❑ ■ Other (specify): 7. Volume of wastewater to be permitted in this project: 1800 gallons per day 8. If the • • permitted flow is zero, indicate why: Interceptor Line - Flow will be permitted is subsequent permits that connect to this line Flow has already been allocated in Permit No. `` ' , ❑ Rehabilitation or replacement of existing sewer with no new flow expected PTA 10/fl CI{ APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 2 • PERMIT INFORMATION (CONTINU,ED) 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in . accordance with 15A NCAC 2H .0219(I)(3). (120 gallbedroom)(3 bedrooms/DU)(5 DU) = 1800 GPD 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) 1 Size (Inches) Length (feet) Gravity or Force Main (pull down menu) 8 I 581 Gravity Gravity Gravity Gravity 3 Gravity ; Gravity Gravity ENTER TOTAL LINE LENGTH IN MILES 0.11 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) • Location ID (as shown on plans) Design Flow (MGD) Operational Point GPM @ TDH Power Reliability Option (dual line feed, permanent generator w1ATS, portable generator w/autodiaier, wet well storage) N/A • 112. Does the sewer system comply with the Minimum Desian Criteria for the Fast Trank Permittinn of Pi,mn Rintrnna and Fnrra Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and Indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION Sr 13. Have the following perrnits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No ® N/A Sedimentation and Erosion Control Plan? ® Yes ❑ No ❑ NIA Stormwater? ® Yes ❑ No ❑ N/A G`K APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 •; WATERSHEDCLASSIFICATION., 1. ,Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST TRACK SEWER SYSTEMS)" to collect and record the stream classlfication data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see Instructions for addresses) OR indicate the following: • A Watershed Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, • A Watershed Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location iD on Map Name of Waterbody i County I River Basin Waterbody Stream Index Waterbody Classification SITE UT - South Prong _West Brannh Rockv Mecklenburg Yadkin 13-17-3-1 C Submit the 8.5" x 11" topographic map as required In Instruction VI regardless of whether a classification is provided! a, ' T,z,, 1. Applicant's Certification: - 1 attest that this application for Extension to serve Saddle Oaks Drive has been reviewed by me and is accurate and complete to the best of my knowledge. i understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being retumed as Incomplete. Note: in accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification In any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000' as well as civil enalties up to $25, 000 per violation. 1a. 7 —Y - Signing Official Signature Date - Z = 0.' H a; LL : • -- S3 �, * V . ,. - G., . Professional Engineer's Certification: 1 attest that thisapplication for Extension to serve Saddle Oaks Drive has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. ! further attest That to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that i have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. _ a. Riley D. Burgess, Jr., PE ° ( :`� Professional Engineer Name "�4�. O �a'�� ; �� - F �� 2b. Environmental Design, PA � ,'x i.SS/6 9 f,. Engineering Firm •a r ` SEAL ;2c. 20816 North Main Street, Suite 204 10051 f' Address \ 1( SL r' ' `2d. Cornelius pe. NC 2f. 28031 �Fjy lfli "c5 �. „ .. =} . City State I Zip ,.� �° `E.Du1RF. c -2g. 704-896-8020 2h. 704-892-5479 i. r.burgess@edpa.net Telephone 1 Facsimile E-mail Seal, Signature Date 1, 0 3-D TopoQuads Copyright ®1999 DeLorme Yarmouth, ME 04096 Source Data: USGS }- 11000 ft Seale: 1 : 25,000 Detail: 13-0 Datum: WGS84 STATE OF NORTH CAROLINA UTILITIES COMMISSION RALEIGH DOCKET NO. W-1057 BEFORE THE NORTH CAROLINA UTIL1'1'1.h5 COMMISSION In the Matter of Application by River Run Utility Company, Inc., d/b/a River Ruh at Davidson, 19125 River Run Drive, Davidson, North Carolina, for a Certificate of Public Convenience and Necessity to Provide Sewer Utility Service in River Run Subdivision and Pages Pond Subdivision in Mecklenburg County, North Carolina, and For Approval of Rates ORDER ADOPTING RECOMMENDED ORDER BY THE COMMISSION: On June 1, 1995, the Recommended Order Granting Franchise and Approving Initial Rates was issued in the above -captioned matter. All Parties have stipulated that they will not appeal that Recommended Order. Based on the stipulations and the entire record of this docket, the Commission concludes that the Recommended Order dated June 1, 1995, should be adopted and made effective as of the date of this Order. IT IS, THEREFORE, ORDERED that the Recommended Order Granting Franchise and Approving Initial Rates issued on June 1, 1995, be, and hereby is, adopted and effective upon the date of this -Order. ISSUED BY ORDER OF THE COMMISSION. This the Clday of � 1995 . NORTH CAROLINA UTILITIES COMMISSION (SEAL) ne a S. Thigpen, Chief Clerk 08/01/03 Permit Number WQ0022908 Permit Tracking Slip Program Category Non -discharge Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sonja.williams Permitted Flow 1800 Facility Facility Name Extension to serve Saddle Oaks Drive Location Address Owner Status Project Type In review New Project Version Permit Classification Individual Permit Contact Affiliation FaTzAti« iSsvl z �r /o3 Major/Minor Minor Region Mooresville County Mecklenburg Facility Contact Affiliation Owner Name River Run Utility Company, Inc. Dates/Events Owner Type Non-Govemment Owner Affiliation Paul Neff 18608 River Ford Drive Davidson NC 28036 Scheduled Orig Issue App Received Draft Initiated Issuance 07/11/03 Regulated Activities Subdivision Outfall NULL Public Notice Issue Effective Requested/Received Events Additional information requested Additional information received Expiration Waterbody Name Stream Index Number Current Class Subbasin