HomeMy WebLinkAboutWQ0022908_Regional Office Historical File Pre 2018/94
Michael F. Easley, Governor
William G. Ross Jr., Secretary
r North Carolina Department of Environment and Natural Resources
Alan W. Klimek, P.E., Director
Division of Water Quality
Coleen. H. Sullins, Deputy Director
Division of Water Quality
August 01, 2003
Mr. Paul Neff, Corporate Secretary
River Run Utility Company, Inc.
18608 River Ford Drive
Davidson, North Carolina 28036
Subject: Permit No. WQ0022908
River Run Utility Company, Inc.
Extension to serve Saddle Oaks Drive
Wastewater Collection System Extension
Mecklenburg County
Dear Mr. Neff:
In accordance with your application received on July 11, 2003, we are forwarding herewith
Permit No. WQ0022908, dated August 01, 2003, to River Run Utility Company, Inc. for the construction
and operation of the subject wastewater collection system extension. This permit shall be effective from
the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified
therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein
by reference.
Please pay particular attention to Permit Condition 3 which requires that the wastewater
collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any
individual system -wide collection system permit issued to the Permittee.
Permitting of this project does not constitute an acceptance of any part of the project that does
not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum
Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design
Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as
applicable, unless specifically mentioned herein. Division approval is based on acceptance of the
certification provided by a North Carolina -licensed Professional Engineer in the application. it shall be
the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design
criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General
Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater
collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing
board.
Mooresville Regional Office Internet http://h2o.enr.state.nc.usl
919 N. Main Street, Mooresville, NC 28115 Telephone (704) 663-1699 Fax (704) 663-6040
NCDENR
DENR Customer Service Center Telephone 1 877 623-6748
Mr. Paul Neff
Page 2
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North
Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby
granted to River Run Utility Company, Inc. for the construction and operation of approximately 581
linear feet of 8-inch gravity sewer to serve 5 residential units as part of the Extension to serve Saddle
Oaks Drive project, and the discharge 1,800 gallons per day of collected domestic wastewater into the
River Run WVVTP (NPDES No. NC0067920) existing sewerage system, pursuant to the application
received July 11, 2003 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer
Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design
Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as
applicable; and other supporting data subsequently filed and approved by the Department of
Environment and Natural Resources and considered a part of this permit.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have
the right to request an adjudicatory hearing upon written request within 30 days following receipt of this
permit. This request must be in the form of a written petition, conforming to Chapter 150B of North
Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service
Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and
binding.
if you need additional information concerning this matter, please contact Sonja Williams at (704)
663-1699.
Sincerely,
D. G
for Alan W. Klimek, P.E.
cc: Mecklenburg County Health Department
Mecklenburg County Department of Environmental Protection
Mooresville Regional Office, Water Quality Section (WWTF Permit No. NC0067920)
Riley Burgess, Environmental Design, PA
Water Quality Central Files
NDPU Files
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT
This permit shall be effective from the date of issuance until rescinded and shall be subject to the
following specified conditions and limitations:
1. This permit shall become voidable unless the wastewater collection facilities are constructed in
accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's
(Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the
Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force
Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically
mentioned herein.
2. This permit shall be effective only with respect to the nature and volume of wastes described in the
application and other supporting data.
3. The wastewater collection facilities shall be properly maintained and operated at all times. The
Permiee shall maintain compliance with an individual system -wide collection system permit for the
operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual
permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H
.0227:
a. The sewer system shall be effectively maintained and operated at all times to prevent
discharge to land or surface waters, and any contravention of the groundwater standards in
15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200.
b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively
maintained.
c. An operation and maintenance plan shall be developed and implemented.
d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e.
365 days per year). Pump stations that are connected to a telemetry system shall be
inspected at least once per week.
e. High -priority sewer lines shalt be inspected at least once per every six-month period of time.
f. A general observation of the entire sewer system shall be conducted at least once per year.
g. Inspection and maintenance records shall be maintained for a period of at least three years.
h. Overflows and bypasses shall be reported to the appropriate Division regional office in
accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by
North Carolina General Statute §143-215.1C.
4. This permit shall not be transferable. In the event there is a desire for the wastewater collection
facilities to change ownership, or there is a name change of the Permittee, a formal permit request
shall be submitted to the Division accompanied by documentation from the parties involved, and
other supporting materials as may be appropriate. The approval of this request shall be
considered on its merits and may or may not be approved.
5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to
interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater
to the surface waters of the State.
6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a
copy of the construction record drawings, as well as supporting design calculations for any pump
stations permitted as part of this project shall be received from a North Carolina -licensed
Professional Engineer certifying that the facilities have been installed in accordance with this
permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12,
1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump
Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this
project is to be completed in phases and partially certified, you shall retain the responsibility to
track further construction approved under the same permit, and shall provide a final certificate of
completion once the entire project has been completed. A copy of the construction record
drawings, indicating the facilities constructed in the phase being certified, shall be submitted with
each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record
Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting
Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617.
7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life
of the wastewater collection facilities.
8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the
Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's
Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted
June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an
enforcement action by the Division, in accordance with North Carolina General Statutes §143-
215.6A through §143-215.6C.
9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the
creation of nuisance conditions, the Permittee shall take immediate corrective action, including
those as may be required by this Division, such as the construction of additional or replacement
facilities.
10_ The issuance of this permit shall not exempt the Permittee from complying with any and all
statutes, rules, regulations, or ordinances that may be imposed by other government agencies
(local, state and federal) which have jurisdiction, including but not limited to applicable river buffer
rules in 15A NCAC 2B -.0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4
and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands
under 15A NCAC 2B .0200 and 15A NCAC 2H _0500.
rrincompliance Notification:
The Permittee shall report by telephone to the Mooresville Regional Office, telephone number
(704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working
day, following the occurrence or first knowledge of the occurrence of either of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable
of adequate wastewater transport, such as mechanical or electrical failures of pumps, line
blockage or breakage, etc.; or
b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters
without treatment of all or any portion of the influent to such station or facility.
Persons reporting such occurrences by telephone shall also file a written report in letter form within
five days following first knowledge of the occurrence. This report must outline the actions taken or
proposed to be taken to ensure that the problem does not recur.
Permit issued this the 1st day of August, 2003.
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
for Alan W. Kli , P.E., Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number WO0022908
Fast Track Engineering Certification
Permit No. WQ0022908
August 01, 2003
Complete and submit this form to the permit issuing regional office with the following:
• One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection
system extension
• supporting design calculations (selected pumps, system curve, operating point, available storage if portable
generator(s) or storage greater than longest past three year outage reliability option selected) for any pump
stations permitted as part of this project
• Changes to the project should be clearly identified on the record drawings or in written summary form. Permit
modifications are required for any changes resulting in non-compliance with this permit, regulations or
minimum design criteria.
This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all
required supporting documentation have been received by the Division. Therefore, it is highly recommended
that this certification be sent in a manner that provides proof of receipt by the Division.
ENGINEER'S CERTIFICATION
❑ Partial El Final
I, , as a duly registered Professional Engineer in the State of North Carolina, having
been authorized to observe (❑ periodically, ['weekly, ❑ full time) the construction of the Extension to serve
Saddle Oaks Drive, Mecklenburg County project for the Permittee hereby state that, to the best of my abilities,
due care and diligence was used in the observation of the construction such that the construction was observed
to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's
(Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's
Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000
as applicable; and other supporting materials.
North Carolina Professional Engineer's
seal, signature, and date:
SEND THIS FORM & SUPPORTING DOCUMENTATION
WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS
MOORESVILLE REGIONAL OFFICE
919 N. MAIN STREET
MOORESVILLE NC 28115
The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any
wastewater flow made tributary to the wastewater collection system extension prior to completion of this
Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate
enforcement actions.
ck APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS
PAGE 1
USE THE TAB KEY TO MOVE FROM FIELD TO FIELD!
Application Number:
(to be completed by QWQ) W a AOZZ90e
I. Owner: -
la. River Run Utility Company, Inc.
Full Legal Name (company, municipality, HOA, utility, etc.)
Ib. Paul F. Neff, Corporate Secretary •
Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!)
1c.
The
•
legal entity
Individual,
who will own this system is:
■ Federal 0 Municipality ❑ State/County
■
Private Partnership ® Corporation
■
Other (specify):
-
Id. 18608 River Ford Drive'
le. Davidson
- • LL
Street Address
City
Z
1f. North Carolina
lg. 28036
Z
State
Zip Code
O
lh. 704-896-8811
11. 704-896-8683
1 j.
-
Telephone
Facsimile
E-mail
t)
2. Project (Facility) Information:
a2a.
Extension to serve Saddle Oaks Drive
b. Mecklenburg
a
Brief Project Name (permit will refer to this name)
County Where Project is Located
<
3. Contact Person:
Q
3a. Riley D. Burgess, Jr., PE Engineer of Record
Name and Affiliation of Someone Who Can Answer Questions About
this Application
3b. 704-896-8020
3c. r.burgess@edpa.net
Phone Number
E-mail
1. Project is ► o New 0 Modification (of an existing permit)
If Modification, Permit No.:
2. Owner is ® Public (skip to Item B(3)) • Private (go
to Item 2(a))
If private, applicant will be: -
2b. If sold, facilities owned by a (must choose one)
12a.
_
I
•
•
0
Retaining Ownership (i.e. store, church, single office, etc.)
Leasing units (lots, townhomes, etc. - skip to Item B(3))
Selling units (lots, townhomes, etc. - go to Item B(2b))
• Public Utility (Instruction III)
0 Homeowner Assoc./Developer (Instruction IV)
p0' 3. River Run Utility Company, Inc.
f Owner of Wastewater Treatment Facilit
y ty (V11WTF) Treating Wastewater From This Project.
< 4a. River Run WWTP
4b. NC 0067920
1 Name of WWTF
WWTF Permit No.
0 5a. River Run Utility Company, inc.
5b. 8-inch
5c. WQ 0001807
:LLZ' Owner of Downstream Sewer
Receiving Sewer Size
Permit Number of Downstream Sewer
r
H•
6. The origin of this wastewater is (check all that apply):
M' '
_
W :.
�" .
® Residential Subdivision
D Apartments/Condominiums
0 Mobile Home Park
El School
• Car Wash
■ Institution
0 Hospital
El Church
100 % DomesticlCommercial
% Industrial
0 Restaurant
Office
❑ Nursing Home
% Other (specify):
• ; x'
❑
■ Other (specify):
7. Volume of wastewater to be permitted in this project: 1800 gallons per day
8.
If the
•
•
permitted flow is zero, indicate why:
Interceptor Line - Flow will be permitted is subsequent permits that connect to this line
Flow has already been allocated in Permit No.
`` ' ,
❑ Rehabilitation or replacement of existing sewer with no new flow expected
PTA 10/fl
CI{ APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS
PAGE 2
•
PERMIT INFORMATION (CONTINU,ED)
9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H
.0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than
that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to
the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in
. accordance with 15A NCAC 2H .0219(I)(3).
(120 gallbedroom)(3 bedrooms/DU)(5 DU) = 1800 GPD
10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary)
1
Size (Inches) Length (feet)
Gravity or Force Main
(pull down menu)
8 I 581
Gravity
Gravity
Gravity
Gravity
3
Gravity
;
Gravity
Gravity
ENTER TOTAL LINE LENGTH IN MILES 0.11
11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary)
•
Location ID
(as shown on plans)
Design Flow
(MGD)
Operational Point
GPM @ TDH
Power Reliability Option
(dual line feed, permanent generator w1ATS,
portable generator w/autodiaier, wet well storage)
N/A
•
112. Does the sewer system comply with the Minimum Desian Criteria for the Fast Trank Permittinn of Pi,mn Rintrnna and Fnrra
Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable?
® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and Indicate why a
variance is requested:
SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION
Sr
13. Have the following perrnits/certifications been submitted for approval?
Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No ® N/A
Sedimentation and Erosion Control Plan? ® Yes ❑ No ❑ NIA
Stormwater? ® Yes ❑ No ❑ N/A
G`K APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3
•;
WATERSHEDCLASSIFICATION.,
1. ,Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03
(FAST TRACK SEWER SYSTEMS)" to collect and record the stream classlfication data below (attach additional sheets as
necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality
regional office (see Instructions for addresses) OR indicate the following:
•
A Watershed Classification is not needed because all parts of the project are at least 100 feet away from any down
slope waterbody; AND,
• A Watershed Classification is not needed because the design does not depend on wet well storage as a power
reliability option for any pump station near a Class C down slope waterbody.
Location iD
on Map
Name of
Waterbody
i
County I River Basin
Waterbody Stream
Index
Waterbody
Classification
SITE
UT - South Prong
_West Brannh Rockv
Mecklenburg
Yadkin
13-17-3-1
C
Submit the 8.5" x 11" topographic map as required In Instruction VI regardless of whether a classification is provided!
a, '
T,z,,
1. Applicant's Certification: -
1 attest that this application for Extension to serve Saddle Oaks Drive has been
reviewed by me and is accurate and complete to the best of my knowledge. i understand that if all required parts of this
application are not completed and that if all required supporting documentation and attachments are not included, this
application package is subject to being retumed as Incomplete. Note: in accordance with North Carolina General
Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or
certification In any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000'
as well as civil enalties up to $25, 000 per violation.
1a. 7 —Y
-
Signing Official Signature Date
-
Z =
0.'
H
a;
LL :
• --
S3 �, *
V . ,.
-
G.,
. Professional Engineer's Certification:
1 attest that thisapplication for Extension to serve Saddle Oaks Drive has been
reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and
all other supporting documentation to the best of my knowledge. ! further attest That to the best of my knowledge the
proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria
for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump
Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance.
Although certain portions of this submittal package may have been developed by other professionals, inclusion of these
materials under my signature and seal signifies that i have reviewed this material and have judged it to be consistent with
the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who
knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2
misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
_
a. Riley D. Burgess, Jr., PE °
(
:`�
Professional Engineer Name
"�4�.
O
�a'�� ; ��
-
F �� 2b. Environmental Design, PA
� ,'x i.SS/6 9
f,.
Engineering Firm •a
r
` SEAL
;2c. 20816 North Main Street, Suite 204
10051 f'
Address
\ 1( SL
r' '
`2d. Cornelius pe. NC 2f. 28031
�Fjy lfli "c5
�. „ ..
=} .
City State I Zip
,.�
�° `E.Du1RF. c
-2g. 704-896-8020 2h. 704-892-5479 i. r.burgess@edpa.net
Telephone 1 Facsimile
E-mail
Seal, Signature Date 1, 0
3-D TopoQuads Copyright ®1999 DeLorme Yarmouth, ME 04096 Source Data: USGS }- 11000 ft Seale: 1 : 25,000 Detail: 13-0 Datum: WGS84
STATE OF NORTH CAROLINA
UTILITIES COMMISSION
RALEIGH
DOCKET NO. W-1057
BEFORE THE NORTH CAROLINA UTIL1'1'1.h5 COMMISSION
In the Matter of
Application by River Run Utility Company, Inc., d/b/a
River Ruh at Davidson, 19125 River Run Drive,
Davidson, North Carolina, for a Certificate of Public
Convenience and Necessity to Provide Sewer Utility
Service in River Run Subdivision and Pages Pond
Subdivision in Mecklenburg County, North Carolina,
and For Approval of Rates
ORDER
ADOPTING
RECOMMENDED
ORDER
BY THE COMMISSION: On June 1, 1995, the Recommended Order Granting Franchise
and Approving Initial Rates was issued in the above -captioned matter. All Parties have stipulated that
they will not appeal that Recommended Order. Based on the stipulations and the entire record of this
docket, the Commission concludes that the Recommended Order dated June 1, 1995, should be
adopted and made effective as of the date of this Order.
IT IS, THEREFORE, ORDERED that the Recommended Order Granting Franchise and
Approving Initial Rates issued on June 1, 1995, be, and hereby is, adopted and effective upon the date
of this -Order.
ISSUED BY ORDER OF THE COMMISSION.
This the Clday of � 1995
.
NORTH CAROLINA UTILITIES COMMISSION
(SEAL)
ne a S. Thigpen, Chief Clerk
08/01/03
Permit Number WQ0022908
Permit Tracking Slip
Program Category
Non -discharge
Permit Type Fast Track
Gravity Sewer Extension, Pump Stations, & Pressure Sewer
Extensions
Primary Reviewer
sonja.williams
Permitted Flow
1800
Facility
Facility Name
Extension to serve Saddle Oaks Drive
Location Address
Owner
Status Project Type
In review New Project
Version Permit Classification
Individual
Permit Contact Affiliation
FaTzAti« iSsvl z �r /o3
Major/Minor
Minor
Region
Mooresville
County
Mecklenburg
Facility Contact Affiliation
Owner Name
River Run Utility Company, Inc.
Dates/Events
Owner Type
Non-Govemment
Owner Affiliation
Paul Neff
18608 River Ford Drive
Davidson
NC 28036
Scheduled
Orig Issue App Received Draft Initiated Issuance
07/11/03
Regulated Activities
Subdivision
Outfall NULL
Public Notice Issue Effective
Requested/Received Events
Additional information requested
Additional information received
Expiration
Waterbody Name Stream Index Number
Current Class Subbasin