Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0022458_Regional Office Historical File Pre 2018
Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality April 29, 2003 . Mr. Daniel Spinicci, PE Manager, Facilities Design & Construction Central Piedmont Community College P.O. Box 35009 Charlotte, NC 28235-5009 Subject: Permit No. WQ0022458 Central Piedmont Community College Academic Center Wastewater Collection System Extension Mecklenburg County Dear Mr. Spinicci: In accordance with your application received March 25, 2003, we are forwarding herewith Permit No. WQ0022458, dated April 29, 2003, to Central Piedmont Community College for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet: 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; and 3) the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations ,and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 919 N. Main Street, Mooresville, NC 28115 Internet hltp:11h2o.enr.state.nc.usl Telephone (704) 663-1699 Fax (704) 663-6040 AS A NCDENR DENR Customer Service Center Telephone 1 800 623-7748 Mr. Daniel Spinicci Page 2 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to Central Piedmont Community College for the construction and operation of approximately 501 linear feet of 6 & 8-inch gravity sewer, to serve (Auditorium/ Classroom Facility to serve 900 students) as part of the Academic Center project, and the discharge of 17,465 gallons per day of collected domestic wastewater into the City of Charlotte's Sugar Creek WVVTP (NPDES No. NC0024937) existing sewerage system, pursuant to the application received March 25, 2003 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall become voidable unless the agreement between Central Piedmont Community College and City of Charlotte for the collection and final treatment of wastewater is in full force and effect. The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and shall be a condition of this permit, Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by North Carolina General Statutes §143-215.6A to §143-215.6C for violation of or failure to act in accordance with the terms and conditions of this permit. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, / tr Alan W. klimek, cc: Mecklenburg County Health Department Mecklenburg County Department of Environmental Protection Mooresville Regional Office, Water Quality Section (WWTF Permit No, NC0024937) Mr, Theodore Sanchez Jr., Little Diversified Architecutral Consulting Water Quality Central Files NDPU Files NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall .be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 21...0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 4. This permit shall not be transferable. in the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be,maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other govemment agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall report by telephone to the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 29th day of April, 2003. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimc, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WO0022458 Fast Track Engineering Certification Permit No. WQ0022458 April 29, 2003 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for anv changes resulting in non-compliance with this permit. regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERT1FICAT1ON ❑ Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Academic Center, Mecklenburg County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 919 N. MAIN STREET MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Michael F. Easley. Governor • WII trim G. Ross .Tr_ Sea --wry North Carolina Department of Env zonmerit and Natural Resources Alan W. Kimei, P_E, Dicr Division of Water Quasiy CERTIFIED MAIL RETURN RECEIPT REQUESTED Signing Official's name and title Applicant Mailing Address City, State, Zip Dear Applicant Name: DATE / mtisecc d im l S W Qb 0 22 4-518 Subject: Return of Permit Application Package Project Name Wastewater Collection System Extension XXXX County The Division of Water Quality's Mooresville Regional Office is unable to accept the endorsed app i lion package for review for the following reason(s): CHOOSE THOSE THAT APPLY, DELETE ALL OTHERS AS NECESSARY ✓ Item XXXX of the application has not been completed as is required by Instruction 1_ of the application form. ✓ The application form submitted for the subject project is no longer accepted. Please complete and retum the most current version of the fast -track application form (FORM: FTA 02103). This form is available for download from our Non -Discharge Permitting Unit web site located at http://h2o.enr.state.nc.us/ndpu. Please use FORM: FTA 02103 for all gravity sever, pump station and/or force main project submittals unless otherwise directed. This form replaces FORM FTA 06/00. ✓ An application fee was not submitted as is required by Instruction IL of the application and IEA NCAC 2H .0205(c)(1)(A). ✓ Based on your answer to question B(2)(c) in the application, a Certificate of Public Convenience and Necessity is required by instruction III of the application form. ✓ A flow acceptance letter was not provided by the owner of the downstream sewers and/or the owner of the receiving wastewater treatment facility as is required by lnsintciion V of the application. Flow acceptance letters must contain the following minimum information appffnt and project name, amount of flow accepted and name and permit number of the receiving wastewater treatment facility. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the application date. Intergovernmental agreements orother contracts will not be accepted in lieu of a project -specific flow acceptance letter. ✓ A North Carolina -licensed Professional Engineer did not sign, seal and date the Prate Engineer's Certification in Item V of the application. Mooresville Regional Office 919 N. Main Street, Mooresville, NC 28115 DENR Customer Service Center An Equal Opportunity Action Employer Internet M#p://h2o.enr.state.nc_r' Telephone (704) 663-1699 Fax (704) 5 3- Telephone 1 800 623-7748 50% recycled/10% pacer pZper ✓ The Applicant did not sign the Applicant's Certification in Item V of the application. Note that ail applications shall be signed by an appropriate official as required by 15A NCAC 2H .0206(b). ✓ ADD ANY OTHER CONCERNS OR ISSUES THAT WERE DISCOVERED DURING THE PRE - REVIEW THAT SHOULD BE ADDRESSED IN ORDER TO PREVENT THE NEED FOR AN ADD - INFO REQUEST WHEN THE APPLICATION IS RESUBMITTED. Please note that the item(s) listed above must be included andlor completed prior to resubmitting the permit application package for approval. Your application is being returned as incomplete in accordance with 15A NCAC 2H .0208. The success of the fast -track approval process depends upon the receipt of complete and accurate applications. Please make the appropriate corrections and resubmit the application. The review process will then begin upon receipt of the completed andfoc corrected application. Please be advised that construction andlor operation of wastewater collection system extension v hout a valid permit is a violation of North Carolina General Statute 143-215.1 and may subject the Applicant to appropriate enforcement actions in accordance with North Carolina General Statute 143-215.6_ Civ� penalties of up to $25,000 per day per violation may be assessed for failure to secure a permit r- by North Carolina General Statute 143-215.1. If you should .have any questions regarding the acceptance of your application, please do not heste to contact me at the number shownin our letterhead. Thank you for your cooperation. Sincerely, REVIEWER Title Enclosures cc: Engineer's name and firm (no enclosures) Application retum file TO FROM TO FROM n 0 FAST TRACK APPLICATION TRANSFER DIVISION OF WATER QUALITY NON DISCHARGE PERMITTING UNIT Corey Basinger, Winston-Salem Regional Office Date: 3/28/03 Dee Browder, Mooresville Regional Office Barbara Scantling,:Fayetteville Regional Office Kim D. Cole, Washington Regional Office Paul Clark, Raleigh Regional Office Dean Hunkele, Wilmington Regional Office Roger Edwards, Asheville Regional Office Marie Doklovic 919-733-5083 x 371 91.9-715-6048 (FAX) rmarie.doklovic ncmail.net Application Number: WQ0022458 County: Applicant: Central Piedmont CC Project Name: klenburg Academic Center The attached application was inadvertently sent to the central office. I have reviewed the application and. deemed it to be complete. The minirn.um information was entered into RIMS to generate a WQ number. We also cashed the check and sent a letter to the engineer letting hire know the application was sent to your office (attached). The following items should be performed by your regional office: L] Update BIMS with correct reviewer.. Add remaining information into BIMS such as related miles of sewer fine, etc. number, flow, regulated activity,. Wait to receive my additional information„request response from the applicant before issuance. Enter the additional information request date into RIMS as shown on the tracking sheet. El Send an additional information request for: C Review application for any additional information required. Approve project flow (previous P4 procedure). Draft, issue and distribute penult/application package. Other: Please remember to update RIMS with any events/dates during your process and especially before permit issuance. Call or E-mail .me with any questions. Thanks! 03/28/03 Permit Number WQ0022458 Permit Tracking Slip Program Category Non -discharge Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dee.browder Permitted Flow Facility Status Project Type In review New Project Version Permit Classification Individual Permit Contact Affiliation Facility Name Academic Center Location Address Owner Major/Minor Minor Region Mooresville County Mecklenburg Facility Contact Affiliation Owner Name Central Piedmont Community College Dates/Events Owner Type Non-Govemment Owner Affiliation Daniel Spinicci Facilities Service Bldg. Charlotte NC 28235 Scheduled Orig Issue App Received Draft Initiated Issuance 03/25/03 Regulated Activities NULL Outfail NULL Public Notice Issue Effective RequestedlReceived Events RO staff report received RO staff report requested Additional information requested Additional information received Expiration Waterbody Name Stream Index Number RODGERS HARDIN A A A LLIA ACE PAY Rodgers Builders, Inc. HARDIN CONSTRUCTION COMPANY. LLC P.O. BOX13446 CHARLOTTE, NC 26213-0000 (7041537-6044 Current Class DATE INVOICE AMOUNT Subbasin 66-13/633 1020 DATE � I� TO?HD CROER or 3Zlr03 l n V / C Dr 10,4 eovior o r' //fi1r 4, YJGW22,1456) BankofAmerira /DOLLARS Ac) MI; I PISCD� CHECK AMOUNT ,I KO1E V 11'00 /0 20e 1:053000 i96r: 0006404400410' _ f f Michael F, Easley, Governor JiIam G. Ross Jr,, Secretary North Carolina Department ot Environment and Natural Resources Ain W. Klimek, P.E., Director Division of Water Quality March 28, 2003 Theodore Sanchez Jr., PE Little Diversified Architectural Consulting 5815 Westpark Drive Charlotte, NC 28235 Subject: Transfer of Fast Track Permit Application Package Academic Center - Application No. WQ0022458 Wastewater Collection System Extension Mecklenburg County Dear Mr, Sanchez: The Non -Discharge Permitting Unit of the Division of Water Quality (Division) acknowledges receipt of your permit application and supporting materials on March 25, 2003. However, as of March 14, 2003, the central office transferred responsibility for this permitting program to the regional offices per the attached letter. This letter is to inform you of our new procedures and let you know that we have forwarded your package to the Mooresville Regional Office for review and permitting. Please also note at this time, processing fast -track permit applications can take as long as 30 days after receipt of a complete application. If you have any questions about your permit application, please contact Dee Browder at the Mooresville Regional Office at 704-663-1699. Please reference the application number shown above. For general questions about the Fast Track permitting program, contact me at 919-733-5083, extension 371, or via e- mail at marie.dokioviciuncmail.net Sincerely, fJ f fft,f„ K. Marie Doklovic, P.E. Environment& Engineer Enclosure cc: Mooresville Region& Office, Water Quality Section Non -Discharge Permitting Unit 1617 Mai i Service Center, Raleigh, NC 27699-16'17 Internet nttp://h2o,enr,state.nc,us/ndpu Telephone (919) 733-5083 Fax (919) 71 DENR Customer Service Center An Equal Opportunity Action Employer Telephone 1 8.00 623-7748 recycled."10", post -consumer paper RO DG ERS HARDIN Transmittal Project [1059] - Central View Piedmont Community College e 3/21/2t}03 Rodgers Builders, ,Inc. 1330 East 4th Street, Suite A Charlotte, NC 28204 Transrnitta No. 1059- Phone: (704) 344-4490 00078 Fax: (704) 344-4495 State of North Carolina Dept. of Environment and Na Resources 512 North Salisbury Street, Suite 1219 Raleigh, NC 27604 Phone (919) 733-5083 Fax (919) 715-6048 Attn From John Daniel Subject Application for Water & Sewer Tap Fees We are transmitting the following to you: r Product Data r Samples r Architectural Drawings r Letters r Engineering Drawings r Change Orders 21/2003 e being sent w Enclosed r Under Separate Cover N. Via U.S. Mail r Shop Drawings r Specifications r Submittal r ©&M Manuals r Plans r Prints r Addenda RApplication & Payment Remarks Please see attached Application and enclosed check #1020 of $400.00. Copies To Dan Spinicci, CPCC, David Powlen, Little & Associates, Architects, Kevin Patton, Rodgers Hardin, Jonathan Hartsell, Rodgers Hardin Received By: Date: State of North Carolina Department of Environment and Natural Reson Division of Water Quality FAST -TRACK APPLICATION for GRAVITY SEWERS, FUMY STATIONS, AND FORC sure sewers systems are not, to be included as part of this application package)' THIS FORM MAYBE PHOTOCOPIED FOR USE AS AN ORIGINAL INSTRUCTIONS: Indicate that you have included the following list of required application package items by signing your initials in the space provided next to each item. Failure to submit all required items will lead to additional processing and review time for the permit application. X A. Application Form - Submit one original and one copy of the completed and appropriately executed application form. Any changes to this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not peed to submit ()culled plans and specifications unless you respond NO to item 1V.b. and/or item IV 10, B. Attachment - Submit the completed and properly executed Form WSCA 10/99 for each watershed within the project location. X C. Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). N/A D. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately - owned public utility, submit two copies of the Certificate of Public Convenience and Necessity, which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a Certificate of Public Convenience and Necessity has not been issued, provide two copies of a letter from the NC Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area is contiguous to an existing franchised area, and/or that franchise approval is expected. ILL&F,.. Operational. Agreements — Submit one original and two copies of a properly executed operational agreement if the sewer extension will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparcels, etc.) that will be owned by a homeowners' association or developer. If the applicant is a homeowners' association, use Form HOA 10/99. If the applicant is a developer, use Form DEV 10/99. F. Flow Acceptance Letters — If the owner of the downstream sewers and/or WWTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the downstream sewers and WWTF. Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted, and name and permit number of the receiving sewers/WWTF. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the application date. Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific flow acceptance letter. THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY NON -.DISCHARGE PERMITTING UNIT By U.S. Postal Servipg: to rle t 1617 MAIL SERVICE CENTER 512 NORTHSALISBURY STREET, SUITE 1219 RALEIGH, NORTH CAROLINA 27699-1617 RALEIGH, NORTH CAROLINA 27604 TELEPHONE NUMBER: (919) 733-5083 FACSIMILE NUMBER: (919) 715-6048 For more information, visit our web site at: h2o,enr.stale.nc.us/ndpu/ F©RM: FTA 06/00 Page 1 of 5 Application Number: GENERAL INFORMATION: 1. Applicant's name (name of the municipaltty, corporation. individual, etc.): 2. Owner's or signing official's name and title address of applicant:*444 City: State: Telephone nu 1.-3430 4. Project name (name of the subdivision, facility or establish 5. County where project is located: 3 6. Fee submitted: $ 400. 00 7. Name and complete address of engineering firm: 5815 etpark Drive City: Charl.t tte Zip: umbel. (See Instruction C.) State: NC Zip: 8 2 17 Telephone number: (704 ) 561 .347 Facsimile number: ( 704 ) 561.8777 8. Name and affiliation of contact person who can answer questions about application: 1)C 7„ . David C. Pow.len, RLA EL PERMIT INFORMATION: 1. Project is: new; modification 2. If this application is being submitted as a result of a modification to an existing permit, provide: existing permit number and the issuance date Applicant is: public _ ry If private, units (lots, townhomes, etc.) are: leased (Skip to item III.); sold If sold, facilities owned by a: public utility (See Instruction D.); homeowners' association/developer (See Instruction E.) INFORMATION ON WASTEWATER: 1. Please provide a one- or two -word description specifying the origin of the wastewater (school,. subdivision, hospital, commercial facility, industry, apartments, condominiums, etc.): 2. Volume of wastewater generated by this projectgallons per day Explanation of how wastewater flow was determined (15A NCAC 2H .0219(1 4. Nature of FORM: F!'A 06/00 at IAA , Domestic/Commercial; % Other waste - s Page 2 of 5 % Industrial; 5. If wastewater is industrial in nature: a. Level of pretreatment that has been provided to ensure protection of the receiving collection system and wastewater treatment facility: None b. If a pretreatment permit is required, has one been issued? Yes; No. If yes, please attach a copy of the pretreatment permit. If no, provide date application was submitted: IV. DESIGN INFORMATION: I. Brief project description: Academiccenter including 11__classrooms, 1000 seat auditorium and cafe. 2. Owner and name of wastewater treatment facility (WWTF) receiving wastewater (See Instruction _ 0. zmogimeitstri:':,10,k411.144Writ,. 3. WWTF permit number (NC00***** or WQ00*****): 0,40304-203344. 4. List the owner(s) of any intermediate sewers if different from applicant or owner of WWTF (See Instruction F.): 5. Summary of GRAVITY SEWER to be permitted: Diameter (inches) Length (linear feet) 6. Does the subject gravity sewer collection system comply with the most recent version of the Gravity Sewer Minimum Design Criteria and 15A NCAC 2H .0200? Sr Yes; No. If no, please identify criteria and explain: 7. Summary of PUMP STATIONS to be permitted: No. or Narne Design Flow (MGD) Pump Operational Points GPM feet I'DH Reliability Option Selected FORM: FIA 06/00 Page 3 of 5 8. Summary of FORCE MAIN to be permitted: Diameter (inches) Length (linear feet) N/A 9. List any equipment being utilized that is not specifically mentioned elsewhere in the application or as part of the Minimum Design Criteria (e.g., telemetry, hoist, odor control equipment, mechanical bar screens, etc.): None 10. Do the subject pump stations and force mains comply with the Minimum Design Criteria for the Fast- Track Permitting of Pump Stations and Force Mains document adopted June 1, 2000 and 1SA NCAC 2H .0200? Yes; No. If no, please identify criteria and explain: N/A NOTE: If you responded I` NO to item 1V.6. and/or item IV.10. above, two (2) copies of detailed plans, specifications, supporting information, and any other materials pertaining to the identified criteria should be submitted with the completed and appropriately executed application form. FORM: PTA 06/00 Page 4 of 5 CE'RTI.FICATIONS Professional Engineer's Certification: 1, Ted Sanchez, est that this application for Centra lv Piedmont CommuriiCy College Academic Center . has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.614, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. North Carolina. Professional Engineer's seal, signature, and date: Applicant's Certification:. , attest that this application for nt:r J. Piedmont Communtry College Academ` c Centex has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: 3 FORM: FTA 06/00 Page 5 of 5 FEB-2 o LL2 °:3 10:.34 FROM: TO: 7046636040 PA%E:02 State of North Carolina Department of Environment and Natural Resou Division of Water Quality WATERSHED CLASSIFICATION AI l'ACHMENT Any changes made to this form will result is the application being retur (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) ZNSTRUCTIt' NS: To determine the classification of the watersheds) ira which the subject project will be located, you are required to submit this form, with hems I through 8 completed„ to the appropriate Division of Water Quality Regional Office Water Quality Supervisor (see Page 2 of 2) prior to submittal of the application for review At a miniatwm, you rnwst uuchade an 8.5" by 11" copy of the portion of a 7.5-minute US©S Topographic Map that shows the surface waters irnmedrately downslope of the project, You must identify the location of the project and the closest downslope surface waters (waters for which you are requesting the classification) on the submitted map copy. If the facility ill located in the Neuss River Basin, also include a copy of the soil survey reap for the project location, The corresponding non discharge application may not be submitted until this form is completed by the appropriate regional office and included with the aubrrtittat, 1. Applicants rtarrae (name of the municipality, co indivadual, etc.); illy' No 2. Name and complete address of`applicartt: P. 0. Box 3 City: ChAr Telephone number: (1QQ ) Staate: WC Facsurule airs Project name (name of the subdivision, facility or establishment, etc. 4. Country where project is located. 5. Narne(s) of closest surface waters: b. River baain(s) in which the project i 7. Topographic reap Dame and dare 8. North Carolina Professional Engine and date: TO REGIONAL OFFICE WATER QUALITY SUPERVISOR Pkaae provide me with the classificanon(s) of the surface waters, watershe these acnvtttes will occur„ as identified on the attached map segment: Names) of surface waters and river basin(s): Claasification(s) (as established by the EMC). Proposed ciassiftcarion(s), rf epphcable River basin buffer rules, if -applicable: Signature of regtorwal office personnel: FORM: WSCA 10/99 A GAR . ■�+$1.58iy 5Sio SEA 027069 and appropriate truer basins) where Cam. ,OT TE CHARLOTTE-MECKLENBURG UTILITIES February 24, 2003 Mr, David Powlen Little Diversified Architectural Consulting Land Development 5815 Westpark Drive Charlotte, NC 28217 SUBJECT: WATER AND SANITARY SEWER FLOW ACCEPTANCE CPCC — ACADEMIC CENTER Dear Mr, Powlen: In response to your request, a flaw acceptance study of the subject site has been completed and the following has been determined: Upon completion and acceptance of all necessary sewer lines to serve the subject site, Charlotte - Mecklenburg Utilities agrees to accept the gravity sewage flow of 17,465 gallons per day [(900 students x 12 gpolstudent); (1,000 seats x 5 glad/seat); (45 employees x 25 gpolernployee)] from this project for transmission to the Sugar Creek Wastewater Treatment Plant; NPDES permit number NCI0024937, for treatment. This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works; which is contingent upon final acceptance and issuance of a discharge permit from the appropriate local, State, or Federal Agency, whichever might have control. Upon completion and acceptance of all necessary water mains to serve the subject site, Charlotte - Mecklenburg Utilities agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, dated January 2000, (WMSP # 00-00251 & PWS ID # 0160010),, on file with the Public Water Supply Section of NCDENR. However, C-MU cannot guarantee a constant pressure or quality of flow, This agreement is also contingent upon approval by the Division of Environment, Health, and Natural Resources, Charlotte -Mecklenburg Utilities does not expect any of the above con°:.itions tc preclude water or sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the C-MU system is accepted on a first come, first served basis. If you have any questions, you may contact me at (704) 391-5121. Sincerely, CHARLOTTE-MECKLENBURG UTILITIEk Barbara Gross Engineering Assistant CHARLOTTE-MECKLENBURG UTILITIES Engineering Division • New Services Section www.crnutilities.cam 5100 Brookshire Boulevard Charlotte,, NC 28216 Ph: 704/399-2221 Fax 704/393-2219 Page 1 of 1 Marie Doklovic From: "Daniel Spinicci" <Daniel.Spinicci@cpcc.edu> To: <marie.doklovic@ncmail.net> Sent: Friday, March 28, 2003 6:26 AM Subject: Re: New Academic Center Sewer Extension Yes, that is my official signature.. Sorry to put this extra work on you.. Dan.. Daniel A. Spinicci, PE Manager, Facilities Design & Construction Central Piedmont Community College PO Box 35009 Charlotte, NC 28235-5009 (704) 330-6524 Fax (704) 330-6166 »> "Marie Doklovic" <marie.doklovic©ncmail.net> 3/27/03 6:27:38 PM »> Mr. Spinicci, I wanted to verify that you signed the sewer permit application for the new academic center submitted by Little Diversified Architectural Consulting. I'm afraid I can't verify the signature! Just so you know, as of March 14, 2003, we transferred permitting .of these projects to the regional offices. So I will be logging the project in and forwarding it to the Mooresville Regional Office for permitting. Thank you, Marie Doklovic K. Marie Doklovic, PE Environmental Engineer Non -Discharge Permitting Unit Division of Water Quality 3/28/03