Loading...
HomeMy WebLinkAboutWQ0017700_Regional Office Historical File Pre 2018 (3)State of North Carolina Department of Environment � and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director v Douglas Ervin, Vive President Braemar Housing LimitedPartnership 1349 East Broad Street Columbus, OH 43205 CDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES December 2, 1999. Subject: Permit No. WQ0017700 Braemar Housing Limited Partnership The Residences At Braemar Wastewater Collection System Mecklenburg County Dear Mr. Ervin: In accordance with your application received November 8, 1999, attached is Permit No. WQ4017700, dated December 2, 1999, to Braemar Housing Limited Partnership for the construction and operation of the subject wastewater collection extension. This permit shall be effective from the date of issuance until rescinded and you shall be subject to the conditions and limitations as specified in the North Carolina Gravity Sewer Design Criteria adopted February 12, 1996 and the attached permit. In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 893 linear feet of 10-inch gravity sewer and 1,016 linear feet of 8-inch gravity sewer to serve 160 apartment units as part of The Residences At Braemar project, and the discharge of 21,600 GPD of collected domestic wastewater into the Charlotte - Mecklenburg Utilities Department's existing sewerage system, pursuant to the application received November 8, 1999, and in conformity with the North Carolina Gravity Sewer Design. Criteria. The sewage and wastewater collected by this system shall be treated in the Charlotte - Mecklenburg Utilities Department Wastewater Treatment Facility (NPDES Permit No. NC0024945) prior to being discharged into the receiving stream. This permit shall become voidable unless the agreement between Braemar Housing Limited Partnership and Charlotte -Mecklenburg Utilities Department for the collection and final treatment of wastewater is in full force and effect. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the forrn of a written petition, conforming to Chapter 1.50B of North 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 FAX (919) 715-6048 An Equal opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (l©cal,. state, and federal) which have jurisdiction. If you need additional information concerning this matter, please contact Will 'Wilson at (919) 733-5083 extension 375. Sincerely, rrtki rr T. Stevens cc: Mecklenburg County health Department Mooresville Regional Office, Water Quality Section Engineering Concepts, Inc. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH GRAVITY SEWER COLLECTION SYSTEMS PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of the Division of Water Quality Gravity Sewer Design Criteria adopted February 12, 1996. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The facilities must be properly maintained and operated at all times. 4. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change' of the Permittee, a formal permit request must be submitted to the Division of Water Quality (Division) accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of this permitted facility, a certification and a copy of the record drawings (i.e., as constructed plans) must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the Division of Water Quality Gravity Sewer Design Criteria adopted February 12, 1996, and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Certification and one (1) copy of the "Record Drawings;' to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the Record Drawings shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. 8. Failure to abide by the conditions and limitations contained in this general sewer permit or the North Carolina Gravity Sewer Design Criteria may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 1 9. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater collection facilities. 10. Noncompliance Notification: The Permittee shall report by telephone to the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five (5) clays following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the Second day of December, 1999 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION I rr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0017700 2 Permit No. WQ0017700 December 2, 1999 ENGINEER'S CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the • project, for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit, the certificate of coverage, the North Carolina Gravity Sewer Minimum Design Manual, and other supporting materials. Signature Registration No. Date The above Engineer's Certification must be completed and submitted to the address below with one (1) copy of the "Record Drawings" (i.e., as -constructed plans) of the wastewater collection system This project shall not be considered complete and allowed to operate until this Engineer's Certification and the "Record Drawings" plans have been submitted. Any wastewater flow made tributary to the wastewater collection system prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 CHARLOTTE-MECKLENBURG UTILITIES November 23, 1999 Mr. Jack Ellinwood Engineering Concepts, Inc. PO Box 619 Fincastle, VA 24090 SUBJECT: THE RESIDENCE AT BRAEMAR FLOW ACCEPTANCE Dear Mr. Ellinwood: In response to your request a study of the subject site has been completed and the following has been determined: Upon completion and acceptance of all necessary sewer lines, Charlotte -Mecklenburg Utilities agrees to accept the sewage flow of 21,600 gallons per day (160 units at 135 GPD/home) from this project for transmission to McAlpine Creek Wastewater Treatment Plant, NPDES permit number NC0024970, for treatment This acceptance of flow is based on the existing capacity of the designated publicly owned treatments works, and contingent upon final acceptance and ISSUANCE OF A DISCHARGE PERMIT from the appropriate local, State, or Federal Agency, whichever might have control. Connection to the C-MUD syetein.is accepted on a FIRST -COME, FIRST -SERVED basie, ae capacity for future projects cannot be guaranteed. Upon completion and acceptance of all necessary water mains, Charlotte -Mecklenburg Utilities agrees to furnish water to the subject site. Currently, an adequate supply of water for domestic use during peak demand times is available to serve the subject site. While water quality to the subject project is regulated by the Safe Drinking Water Act Amendments of 1986, C-MUD cannot guarantee a constant pressure or quality of flow. This agreement is also contingent upon approval by the Division of Environment, Health and Natural Resources. Charlotte -Mecklenburg Utilities does not expect any of the above conditions preclude water or sewer service to the subject site. However, the applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. If you have any questions, you may contact me at (704) 391-5107. Sincerely, MA^ Steven K. Miller CHARLOTTE•MECKLENBURG UTILITIES Engineering, New Services 991 123skm'.doc Enwineerine Division 5100 Brookshire Boulevard Charlotte, NC 2821b 704.399.2221, fax 393.2219 Smillert ici.charlorte.nc.us Charlotte -Mecklenburg Utilities SOURCE: Online USGS topographic map tte 7.5 min. Quadrangle (enlarged to scale shown) in 1996 Source File: 03548OC7. TIF received on tape/group 35080s-2m ion: UTMZ©ne 17 NAD 27 Load Date: 6/26/1999 9:45:16 PM via job DRG-35084s 2m INGNEERNG cows sy e4C. 20 !. ROANOKE sr.. PO BOX 619 SITE LOCATION MAP RESIDENCES AT BRAEMAR CHARLOTTE, E.T.J.- N.0 PROJECT MEMO TO: NCDENR, Reviewer FROM: Michelle Caruthers, Hal T. Bailey, PE CC: File: 02048 DATE: January 19, 2004 RE: Residence at Braemar Sewer Lift Station INTRODUCTION RT N - r �:k�x..0..MA,. ENGINEERING CONCEPTS INC. Permit No. W00017700, dated December 2, 1999, was granted to Braemar Housing Limited Partnership for the construction and operation of the subject wastewater collection extension. However, since that time, complete gravity flow has been determined nonviable. As the utility infrastructure construction for the development is nearing completion, the owner is submitting a Fast -Track Application for the modification of the existing permit. The proposed Residence at Braemar is located in Long Creek. Township, Mecklenburg County, at the intersection of Vance Road and Treyburn Drive. The proposed development consists of a total of 160 apartment units for leased. Onsite sewer and water service will be privately owned and maintained by the developing partnership. Water and sewer connections will be made at existing CMUD lines. Water service will be accomplished with a connection to the existing water main along Treybum Drive. Sewer service will be accomplished with a gravity collection system and lift station within the development. Sewer flows will be directed to the low side of the site where a sewer lift station will force sewer flow back to the higher portion of the site where a public sewer manhole exists. A sewage pump station is needed for this proposed development due to the inability to gravity feed to the existing sewer system in the area. The closest feasible sewage manhole is located at the corner of Treyburn Drive and Vance Road. As built plans of the existing receiving manhole indicate it's approximate depth of 11.7 ft deep with an invert out elevation of 718.46. The lift station location in the proposed subdivision is planned at elevation 711.5. This elevation is 0.5 feet above the FEMA designated 100-yr flood elevation for the adjacent Long Creek. Please find attached, the permit application, miscellaneous support documents, and Supplemental Drawing No. 1. A copy of the testing records and Operation & Maintenance Manual will be submitted separately from the general contractor, the owner's representative. II. SEWER DESIGN FLOW 1. Average Daily Flow = 21,600 gpd See accompanying Flow Acceptance Letter from Charlotte -Mecklenburg Utilities. P.O. Box 619, Fancastle, VA 24090 Phone 540-473.1253, Fax 540-473-1254 1/8 21,600gpd = 15.0 gpm 2. Peaking Factor = 2.5 minimum 3. Design Flow: Pipe = 4 inch SDR 21 15 gpm *2.5 = 37.5 gpm 9say 38 gpm target design flow for each pump V = Q/A = 38 gpm / 7.48 gal/cf / 60 slmin / (pi/4*(3.97"/12)2) = 1.0 fps 4 Velocity too low. Minimum Velocity = 2 fps If pumping rate is 83 gpm, then V = QIA = 83 gpm / 7.48 gallcf / 60 s/min / (pi/4*(4.0712)2) = 2.1 fps Actual Design Peaking Factor = 83115 = 5.5 III. PUMP STATION DESIGN 1. Location: Pump Station is located at approximately the lowest practical point in the development at elevation 711.5. 2. Wet Well: Wetwell Size: 6' diameter produces 211 gal/vertical ft. Desire cycle time to produce between 2 to 8 cycles per hour; V = T (Qddf (1 -- Qddf/Q) Qddf= 15.0 gpm design daily flow Q = 80.0 gpm pumping rate V = volume of cycle, gallons T = cycle time, minutes If 2 starts per hour, then T = 60 min / 2 = 30 min V = 30 (15 (1— 15/80) = 366 gallons Or, 366 / 211 = 1.7' active storage If 8 starts per hour, then T = 60 min 18 = 7.5 min V=7.5(15(1 —15/80)=91 gallons Or, 91 / 211 = 0.4' active storage P.O. Box 619, Fincastle, VA 24090 Phone 540-473-1253, Fax 540-473-1254 2/8 1, Therefore, desired active volume is between 0.4' and 1.7' > choose 1.2', which produces a cycle time of 20.7 minutes, or 2.9 starts per hour. Set Start Lag Pump at 0.5 ft. below High Water Alarm 0.5' Set Start Lead Pump at 1 ft. below Start Lag Pump 1.0' Set Cycle Depth at 1.2 ft. below Start Lead Pump = Stop Lead/Lag 1.2' Set Invert of Pump Station at lft. below Stop Lead/Lag for min. submergence 1.0' Total: 3.7' Invert of influent pipe = 706.62 Set invert of pump station = 697.52 Set Stop Lead/Lag = 698.52 Set Start Lead Pump = 699.72 Set Start Lag Pump = 700.72 Set High Water Alarm = 701.22 Set Top of Pump Station = 711.5 3. Reliability and Emergency Storage: Total storage volume above the high water alarm is 711.5' — 701.22' = 10.3', approximately 211 gal/ft x 10.3 = 2,173 gallons. At design daily flow of 15.0 gpm, this equals 2,173 / 15 = 145 min (2.4 hr). However, during a power outage, the sewer flow is anticipated to significantly drop over the average daily flow. Flows from cooking, showers, and clothes washing will be limited, if not terminated completely. The only anticipated flows during a power outage are from those generated from toilets and sinks. Assuming flows during an outage are 10 percent of the average daily flow, then the available emergency storage volume is 2,1731(0.1 x 15.0 gpm) = 1449 min (24.1 hr) The system does not have a telemetry system to signal a power outage or pump failure. A variance to this requirement is requested based on the stated option provided in Section 5.04.B.4 of the "Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains". As determined by website information provided by the North Carolina Department of Environment and Natural Resources, the description for the zone "C" classification of Long Creek is as follows: "From source to a point 0.6 mile downstream of Mecklenberg County SR 2074." The sanitary sewer lift station for the Residences at Braemar project lies approximately 240' off the centerline of Long Creek near its intersection with Dixon Branch (another category "C" classified stream) which is approximately 1.4 miles upstream from the intersection of Long Creek and Mecklenberg County Secondary Route 2074. This portion of Long Creek is clearly classified category "C". See attachments in the Appendix. Duke Power has provided power outage historical data for the property adjacent to the site (see Appendix for hardcopy of email). One power outage has occurred in the last , three years, and the length of down time was 37 minutes, well within the emergency storage availability. Power outage data for the entire surrounding Vance Road area was P.O. Box 619, Fincastle, VA 24090 Phone 540-473-1253, Fax 540-473-1254 3/8 also included, and indicates a maximum downtime of 37 hours, 19 minutes. Please note; the 37-hour nearby power outage did not affect the adjacent property. Although a significant power outage has not occurred within the past three years, the engineer recommends the owner includes, in the pump station maintenance contract, means of backup portable generator power to the pump station during a power failure. 4. Force Main Present Day Conditions: Minimum Force Main size: 4" for non -clog pumps Sizing: Using the Modified Hazen Williams Equation to estimate the frictional head loss: Hf = 10.44 * L * Q1.85 1 C1.85 1 d4.8655 Determine Equivalent Lengths of force main piping attributes: TABLE 1 Braemar Wastewater Pumping Station Equivalent Lengths (Le) for Minor Losses Type Quantity Unit Le Total Le Reference* 90° bend 3 10.10 30.3 Cameron 45° bend 3 5.0 15.0 Cameron 22.5° bend 1 5.0 5.0 Cameron tee (thru flow) 1 6.70 6.7 _ Cameron _ Gate valve 2 2.7 5.4 Cameron Check valve 1 33.6 33.6 Cameron Total Le 96 (*Ref: Cameron Hydraulic Data, 17th Edition) Length of force main = 1199.8 ft. L = Equivalent Length = 1199.8 ft. + 96 ft. = 1296 ft. Q = 83 gpm C = 140 for initial service design d = 4.0 in. Hf = 10.44 *1296 *831.85 11401.851 4.04.8655 = 6.0 ft. Static Head: Discharge invert = 726.26 Peak in line = 726.26 4 use higher elevation. Pumps off = 698.52 P.O. Box 619, Fincastle, VA 24090 Phone 540-473-1253, Fax 540-473-1254 4/8 • Static Head = 27.7 ft. Total Dynamic Head: Static Head = 27.7 Friction Head = 6.0 TDH = 33.7 ft. Design Condition: 83 gpm at 33.7 ft. TDH 5. Force Main Long Term Conditions: Length of force main = 1199.8 ft. L = Equivalent Length = 1199.8 ft. + 96 ft. = 1296 ft. Q = 76 gpm C = 120 for long term design d =4.0 in. Hf = 10.44 *1296 *761'85 / 1201'85 / 4.04'8655 = 6.8 ft. Static Head: Discharge invert = 726.26 Peak in line = 726.26 4 use higher elevation. Pumps off = 698.52 Static Head = 27.7 ft. Total Dynamic Head: Static Head = 27.7 Friction Head = 6.8 TDH = 34.5 ft. Long-term operating condition is 76 gpm at 34.5 TDH. A flow rate of 76 gpm produces a velocity of approximately 1.95 fps, slightly less than the desired minimum of 2.0 fps. However, proper maintenance through flushing of the forcemain may keep the buildup within the pipe to a minimum and reduce the friction losses through the pipe, in turn maintaining higher velocities. Flushing of the forcemain can be obtained by operating both pumps simultaneously, and should be part of the preventive maintenance plan outlined in the O&M manual. 6. Buoyancy: Buoyancy calculations were performed and are included in the Appendix. P.O. Box 619, Fincastle, VA 24090 Phone 540-473-1253, Fax 540-473-1254 5/8 1 7. Wetwell Detention Time: Average detention time in the wetwell is based on the cycle time at average daily design flow as discussed earlier in section 111.2. Although the average detention time is estimated to be 20.7 minutes, the worst case scenario may be much longer. It is anticipated that the longest detention time may occur between peak evening flows and peak morning flows, typically between 8:00 PM and 7:00 AM. It is anticipated that the pump will cycle during each of these peak demand periods, therefore, the maximum detention time is approximately 11 hours. 8. Forcemain Detention Time: Total volume in the forcemain is 1200 ft x (3.14 x (2"/12)"2 = 105 cu. ft., or 786 gallons 786 gal / 253 gal per cycle = 3.1 cycles At 2.9 cycles per hour; 3.1 / 2.9 = 1.1 hours average detention 9. Analysis of Depressed Sections of the Forcemain: Longest length of a depressed section, 310 ft x (3.14 x (2"112)"2 = 27 cu. ft., or 202 gallons 202 gal < 253 gal cycle volume, therefore, depressed area will be completely flushed during each cycle. 10. Surge and Water Hammer: The forcemain has been analyzed with respect to the development of hydraulic transients. Calculations indicate the maximum pressure surge to be 33 psi, well within manufacturer's recommendation of a maximum safe pressure surge of 98 psi. See Appendix for calculations. 11. Pump Selection: The following pump has acceptable operating points: Myers Model 4V50M4-21 with 6.5" impeller trim 12. Net Positive Suction Head: 32' - Atmospheric head available 3' - Local variation 1' - Submergence 30' - Net Positive Suction Head Available 18' - Net Positive Suction Head Required 30' available > 18' required, therefore ok P.O. Box 619, Fincasfle, VA24090 Phone 540-473-1253, Fax 540-473-1254 6/8 A ,./ 13. Flow Acceptance: Charlotte -Mecklenburg Utilities has indicated available capacity and has agreed to accept the flow from the development. (See flow acceptance letter in the Appendix). 14. Controls and Instrumentation: See plans for Control Description. The pump station supplier shall provide the required controls and instrumentation. Functionally, the station will operate automatically or manually. The pumps will alternate and will have run time meters installed. Any alarm conditions will be produce audible and visual notifications. 15. Other Considerations: A. Grit Removal: Pumps are capable of passing up to 3 inch solids, so any grit -like substances accumulating in wet well will be passed on. Integrity testing of sewer lines and manholes also insures minimum input of grit -like substances. B. Grease: Since the station will serve a residential community, grease is not expected to pose any operational problems for the pump station that need to be specifically addressed in the design. C. Pump Removal: The pumps specified are small and relatively light in weight. The pumps should be able to be lifted easily with a portable pump hoist using the lifting cable. P.O. Box 619, Fincastle, VA 24090 Phone 540-473-1253, Fax 540-473-1254 7/8 APPENDIX P.O. Box 619, Fincaslle, VA 24090 Phone 540-473-1253, Fax 540-473-1254 8/8 North Carolina Waterbodies Listed by County Note: Waterbodies are listed in more than one county if they cross Bounty lines, Name of Stream Cuir„ Class Date .Prop. Class Basin Report Date: 12131/03 ecords Found; if Search Parameters: County: Meck)enburg Class: Spies: Marne: Desc: index#: Index It CATAWBA .RIVER (Lake Norman below elevation 760) (Iambics Creek (Cathey Creek) Knox Creek I£aa er Creek Ramsey Creek CATAWBA RIVER (Mountalzl From Lyle Creek to Cowan's Ford Dam From source to Lake Norman, Catawba River rg County WS-IV,B„CA 08/03/92 IV,,CA 08/03/92 From Source to Like WS-IV,9(CA 00/03/92 Norman, Catawba River From source to Lake WS-IV,B;CA 08/03/92: ,Norman, Catawba River From source to Lake WS-IV Norman,Catawba River From Cowan's Ford Dam WS-IV;CA 08/03/92 to Water Intake at Island Lake below River Bend Steam elevation 648) Station CATAWBA RIVER From Water Intake at (Mountain River Bend Steam Island Lake below Station to Mountain. elevations, 64H) Island Dam (Town o€ Mount Molly water supply intake) McDowell Creek McDowell Creek Caldwell Station. Creek Caldwell Station Cree Torrence Creek From source to U,S. WS-IV,B;CA 08/03/92 From U.S. Hwy. 21. to WS-IV a point 0,1 mile upstream o£ mouth From source to I-77 From I-77 to McDowell WS-1V Creek 09/01/74 2 09/01/14 From source to McDowell WS-IV 08/03/92 Creek Catawba Catawba Catawba Catawba Catawba Catawba Catawba Catawba Catawba Catawba Catawba Catawba 11- (75) 11-107 11-108 11-109 11-(1.12) 11-(114) 7.1-115-(1) Page l of Name of Stream ©escnption Curr: Class Date Prop, Class Basin Stream Index # McDowell Creek Gar Creek Gar Creek CATAWBA RIVER (Lake Wylie below elevation 570) ilarwoc d Lakes and Brinkley Twin Lakes Long Creek on Branch Vances Twin Lakes Swaringer Lake Long Creek McIntyre Creek. McIntyre Creek From a point 0.7 mile WS-IV;CA 08/03/92 upstream of mouth to Mountain Island Lake, Catawba River From source to a p int 0.6 mile upstream of mouth WS-IV From a point 0.6 mile WS-IV;CA upstream of mouth to Mountain. Island Lake, Catawba River 09/03/92 2 From Mountain Island WS-IV;CA 08/03/92 Dam to 'Interstate Highway 85 Bridge at Belmont Entire lakes and connecting streams to Lake Wylie, Catawba River From source to a point 0.6 mile downstream of Mecklenburg County SR 2074 From source to Long Creek Entire lakes and connecting stream to Dixon Branch Entire lake and connecting stream to Long Creek C V;CA 08/03/92 From a point 0.6 mile WS-IV' downstream of Mecklenburg County SR 2074 to a point 0.4 mile upstream of Mecklenburg County SR 1606 From source to a point 0.3 mile upstream of Mecklenburg County SR. 2025 From a point 0.3 mile upstream of Mecklenburg County SR 2035 t0 Long Cr. C WS-IV 09/01,/74 09/01/7'4 09/01/74 09/01/74 08/03/92 09/01/74 08/03/92 Catawba Catawba Catawba Catawba Catawba Catawba Catawba Catawba Catawba Catawba Catawba Catawba 11-115- (5) 11-116- (1) 16- (2) 1.1-(1171 120-(0.5) 11-120-1 11-120-1-1 11-120-2 11-120- (2.5) 11-120-3- (1) 11.-120-"3- (2) Page 2 of 7 Mitchell Mason From: Tamara T Trexler [tttrexle@duke-energy.com] Sent: Monday, January 05, 2004 4:01 PM To: mmason@engineeringconcepts.com Subject: Reliability History for Braemar Happy New Year Mason! Per your request, I have researched the circuit which will feed the sewer lift station at Braemar. The circuit currently feeding this delivery has had 0 station circuit breaker operations within the last 3 years. The address you provided at 9220 Vance has experienced 1 outage, 37 minutes in duration, in the past 3 years. Hope this information is useful. Your Power Partner, Tammy Tammy Trexler-Whaley, PE / Duke Power / Sales & Service / 6325 Wilkinson Blvd. / Charlotte, NC 28214 tttrexle@duke-energy.com 704-382-5122 (Office) 704-995-4084 (Mobile) 704-382-5300 (Fax) http://www.dukepower.com/ 1 Wd99:Z •9 •uer eW1j pania3aa Three Year Outage History Vance Road Area in Charlotte, N C DATE/TIME 08/09/01 18:42 12/05/02 07:41 12/21/02 13:24 DURATION COMMENTS 2 hr 18 min Line burned down 37 hr 19 min tree on line, ice storm 41 min. tree on line ZO'd 172:VT VC/CZ 9 uef L90V-829—VOL: xed 13ITIOd Dna Buoyancy Caicuations Manhole Nominal Diameter (ft) Manhole Thickness (in) Manhole Invert Elevation Manhole Rim Elevation Water Surface Elevation Manhole Height (ft) Submerged Height (ft) Concrete Unit Weight (pcf) Total Manhole Weight (Ibs) Volume of Displacement (cf) Unit weight of liquid (pcf) Buoyancy Force (Ibs) 4.0 6 705.0 711.5 711.5 150 62.4 6947,0 Extra Weight Required (Ibs) 2499 7 Height of Extra Base (ft) Weight of filled Base (Ibs) Total Manhole Weight (Ibs) 1.5 1518.4 80250 Buoyancy Force (Ibs) 078.84 Positve numbers indicate float Factor of Safety MH-BOUY.XLS 1 1/19/2004 Water Flow Characteristics - Water Hammer PVC and CPVC Pipe Calculation Pressure Sum = aV/ 2.31g = Shock Pressure pipe Is exposed to. Where a= 4660/ (((1+ (Kdi/Et))".5) a= wave velocity, ft/Sec Calculated factor see results below. p= pressure surge caused by the sudden change in velocity V= maximum velocity change, ft/Sec (V= Q/A) Pipe Area =0,785398 * d^2 g= acceleration of gravity, 32,2 ft/Sec "2 k= fluid bulk modulus, 300,000 psi for water di= inside pipe diameter in inches E= modulus of elasticity of the pipe, 420,000 psi PVC, 360,000 psi CPVC, t== pipe wall thickness, inches Q= Flow Through Pipe, GPM PUT DATA. Q= 83 di= 4 V= 2.00 K= 300000 E= 420000 t= 0.214 Results for "a" a= 230 Results for Pressure Surge NOTE: Maximum safe Pressure Serge PVC pipe = 98 PSIC, Critical Time for valve closure/opening or pump startup/shutdown Wave velocity, a, ft/sec: 1230 ength of pipe, ft: 1200 'Critical Time (sec): 2,0 sec Hamlc.xis/PVC LONG-TERM CONDITIONS (C=120) Static Head 27.74 Pipe size (IN) 4.00 3.00 PUMP Equivalent length 1296 0 Additional flow 0 0 FE Meyers Flow FRICTION FRICTION TDH MAX 4V50M4-21 GPM FT FT FT FT 0 0.00 0.00 10 0.16 0.00 27.90 20 0.58 0.00 28.32 30 1.23 0.00 28.97 40 2.09 0.00 29.83 50 3.15 0.00 30.89 66.7 5.37 0.00 33.11 83.3 8.10 0.00 35.84 100 11.36 0.00 39.10 36.3 35.1 33.9 32.8 The Braemar Pump Station System Curve (Long -Term Conditions) 45 - 0 40 a 35 m 30 25 .i 9 .E 20 c 15 0 10 0 5 1- 0 0 20 40 60 Flow Rate 80 (gpm) 100 120 -�4V50M4-21 -o-TDH PUMP CURVE.xls/Long-term 1 Aea;uasaJdls1X 3AH110 dWCld •I + _ O a n ril •'o .ma.�yy L1 C_ 9 N ..r. C N C) 0)p co c co m - Q Z 0 a-z -1 O 7-1 iv a 0 z +0 T' o °o a) z O W C)t ? W N -� O W --1 0 0 0 0 0 0 (1) 0 II OD O p A N-tO O O O �j - Oh ..A COO A c •v N t N 0 O O Q) O O -n -I O O O O O O O O O b 0 b 0 0 0 0 O O O O O O O O O O O coWCO CO O CND CONCo -4 N OD �1 G7 6) - aD co co co — -1. co 00 CA CO CO CO CO n) W cn co OD co 1 W - n XVW Hai NO11.O11:1 -I < m c cn E m N 7, WIDE CROP TO HE PROPERLY TED.fUNCT)c" BOX TO MANHOLE. /OLLGIN pew SPECIFICATIONS FOR 0190E DROP lase' 9 1' BERIAGE POLE opnON INu, wicR MAAS MP PU12 ON PUS 1 PUMPS CST' 1' s:- +--^- FLASHING A0ARti LIGHT �wFanEERPttooF DONTROL Bon POKER SUPPLY CONO1FT CORD SEAL CONIEGTORS FOR (PURER MD SHOWN°N CORDS WATERPROOF ACCESSDOOR2) r.� MUSHROOM VENT PLACED NOT TO INTERFERE WITH HATCH OPENING TOP RAIL (DOLTS ID COVER FRAME) MMERT ELEV. 69752. NOT TO SCALE FUMBLE PIPE JOINTS SHALL BE USED ON Pmt*., BETWEEN THE PUMP STATION STRUCTURES. FLomATIC CHECK VALVE mom VALvE } `PAERIIEDYITE RAIL SUPPORT pap DEPTH PI IPITSS Of 20 MELT GALV. STEEL OR DUCTILE IRON TOP OF STRUCTURE ELEV.. 7119' f/ oast NL PIPE GUIDE RAILS E PU2103 MODEL MYERS 4v50Y4-21 r/6•s• OAPELUR SUBNF ,E NON -CLOG PIMP L1FTOUT ASSENBLY Mom INOST LEVEL INVERT ElEV.70SA 24• CONCRETE BASE FOR ANTI -FLOTATION INVERT ELEV.7O .o BoTTDM OF Ms"' MIST HAVE SMOOTH TROUELED SURFACE FOR MT0. SUPPORT CASTING PUMP STATION'S PUMPS. CONTROLS. RAN. LIFT' OUT, FLOATS. AND VALVES TO BE COORDINATED WITH: CHAD SMAI I EY PREFERRED SOURCES. INC. 321E SMITH FARM RD. STAWNCS, NC. PHONE: 804-271-4057 THIS DRAWING SHALL BE A SUPPLEMENT TO DRAWING C11. "SEWER LIFT STATION DETAIL, DATED MAY 2, 2002. THE REVISIONS, IDENTIFIED AS "I" ON THIS SHEET, ARE REQUIRED TO BRING THE PUMP STATION DESIGN IN CONFORMANCE WITH NCDENR MINIMUM DESIGN CRITERIA FOR THE FAST —TRACK PERMITTING OF PUMP STATIONS AND FORCE MAINS. ENGINEERING CONCEPTS, INC. 20 S. ROANOKE ST,. PO BOX 619 FINCASTLE, VMONA 24090 540.473.1253 FAX: 540473.1254 SUPPLEMENTAL DWG #1 RESIDENCES OF BRAEMAR Into j NTS ECT N0. 01/20/03 02042 \\ ` SANITARY LIFT STATION ENGINEERING CONCEPTS, INC. 20 3. ROANOKE: ST., PO BOX 619 ',CASTLE. VIONA 24090 540.473.t253 FAX:540.473.1254 TREYBURN DRIVE SHEET A' SEWER OVERVIEW PLAN RESIDENCES AT BRAEMAR . JAN, 2004 PmEcCHARLOTTE - NC 02048 SCALE 1 "=120' 1 MATCH LINE • i ENGINEERING CONCEPTS, INC. 20S.ROANOKLST.,POBOX 619 PR4CASTLE YlONA 24090 540473.1253 FAX• 540.473.1254 STING MANHOLE i SHEET 'Bs SEWER OVERVIEW PLAN SCALE1"=120' RESIDENCES AT BRAEMAR JANURY, 2004 CHARLOTTE - NC o NO.