HomeMy WebLinkAboutWQ0016555_Regional Office Historical File Pre 2018Michael F. Easley, Governor William G, Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan Klimek, P. Coleen H. Sullins, Depu Division of Wat March 26, 2004 Mr. Barry Shearin, PE, Chief Engineer Charlotte -Mecklenburg Utilities 5100 Brookshire Blvd Charlotte, NC 28216 ector for ual'ity Subject: Permit No. WQOO16555 Modification 18118 Pompano Place CMU Project No. 379-02-630 Nantz Road (SR 2148) Original CMU Project No. 379-98-586 Pressure Sewer Extension Mecklenburg County Dear Mr. Shearin: In accordance with your permit modification application received January 16, 2004, we are forwarding herewith Permit No. WQ0016555 dated March 26, 2004, to Charlotte - Mecklenburg Utilities for the construction and continued operation of the subject wastewater collection extension. This permit shall be effective from the date of issuance until rescinded, shall void Permit No. WQ0016555 issued May 10, 1999, and shall be subject to the conditions and limitations as specified therein. The modification includes the addition of 968 feet of 2- inch pressure sewer to serve 11 residents along Pompano Place and Delray Drive. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Condition 13(c) (xii) describes the blanket variance given to Charlotte -Mecklenburg for use of SDR 13.5 Class 315 pipe material in lieu of ferrous pipe in certain circumstances. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted Ju e 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules,. Failure to comply may result in penalties in accordance with North Carolina General Statute § 143-215.6A through §143- 215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Non -Discharge Permitting Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 DENR Customer Service Center An Equal Opportunity Action Employer Internet http://h2o,enr.state.nc.us/ndpu Telephone (919) 733-5083 Fax (919) 715-6048 Telephone 1 800 623-7748 50% recycled/10% post -consumer paper Mr. Barry Shearin March 26, 2004 Page 2 If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days foilowing receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding. One set of approved plans and specifications for the latest project is being forwarded to you. if you need additional information concerning this matter, please contact Marie Doklovic at (919) 733-5083 extension 371. Sincerely Alan W. Klimek, P. E. cc: Mecklenburg County Health Department Mecklenburg County Water Quality Program Mooresville Regional Office, Wafer Quality Section (Permit NC0036277) Cooper Burton, PE/WK Dickson & Co., Inc. (Charlotte) Water Quality Central Files NDPU File NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO CHARLOTTE-MECKLENBURG UTILITIES Mecklenburg County FOR THE construction and operation of a pressure sewer collection system consisting of approximately 968 linear feet of 2-inch pressure sewer to serve 11 residences along Pompano Place and Delray Drive, and the discharge of 2,090 GPD of collected wastewater into the Charlotte -Mecklenburg existing sewerage system, pursuant to the application received January 16, 2004, and subsequent additional information received by the Division, and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. Homeowners along the permitted pressure sewer system will be responsible for installing, owning, and maintaining the simplex pump stations connecting to the system; and the continued operation of a pressure sewer system consisting of approximately 780 linear feet of 2- inch pressure sewer, 800 linear feet of 3-inch pressure sewer and 2,210 linear feet of 4-inch pressure sewer to serve 108 residences along Nantz Road, and the discharge of 24,520 GPD of collected domestic wastewater into the Charlotte -Mecklenburg Utilities' existing sewerage system, pursuant to the application received March 8, 1999, and in conformity with the project plan, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. Homeowners along the permitted pressure sewer system will be responsible for installing, owning, and maintaining the simplex pump stations connecting to the system; This permit shall be effective from the date of issuance until rescinded, shall void Permit No. WQ0016555 issued May 10, 1999, and shall be subject to the following specified conditions and limitations: 1. This permit shall become revocable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 1 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. This requirement does not apply to pump stations serving a single building associated with a properly permitted pressure sewer system. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B _0506(a), and public notice shall be provided as required by North Carolina General Statute § 143-215.1 C. 4. The sewage and wastewater collected by this system shall be treated in the Charlotte -Mecklenburg McDowell Creek Wastewater Treatment Facility (NPDES Permit No. NC0036277) prior to being discharged into the receiving stream. 5. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Wafer Quality (Division) accompanied by documentation from the parties involved and other supporting materials as may be appropriate. The approval of this request will be considered on ifs merits and may or may not be approved. 6. Construction of the sewers, pump station(s) and force main shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 7. Upon completion of construction and prior to operation of these permitted facilities, a certification and a copy of the construction record drawings shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings", and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 8. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 2 Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 10. The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (Le., local, state, and federal) having jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, soil erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. The Permittee shall provide information about the proper operating head conditions applicable to the homeowner's specific lot to the homeowner and the selected plumbing contractor for connection to the system by way of an informational packet. Other pertinent information required for the proper selection and installation of the pump station shall be provided to the plumbing contractor. This information shall include the following minimum design criteria for the simplex pump station: a. A minimum of 94 gallons of storage capacity above the pump -on activation level to meet the greater of the Permittee response time for service or the longest non -catastrophic power outage of the previous three years for any simplex pump station serving a single family residence; b. A screened vent for the wet well; c. Fillets located in the wet well at the intersection of the flooring and side walls; d. Sufficient devices which will protect the pump station from vandals; e. Flood protection if the pump station is located below the 100-year flood elevation; f. Audible and visual high water alarms; g. Anti -flotation for the pump station. Buoyancy calculations for the selected pump stations must be completed prior to the release of the final design documents for installation to insure flotation of the pump station will not occur in submerged conditions; and h. Each pump station shall be clearly and conspicuously posted with the telephone number of the maintenance company that can address any problems and instructions to call the number in the event of high water alarm activation. 12. The Permittee shall provide the following for the force main: a. An air relief valve located at all high points along the force main; b. Three feet of cover (minimum) over the force main or the use of ferrous material where three feet cannot be maintained; c. Adherence with the following minimum separations: (I) Storm sewers (vertical) 12 inches (ii) Water mains (vertical -water over sewer) 18 inches or (horizontal) 10 feet (iii) In benched Trenches (vertical) 18 inches (iv) Any private or public water supply source, including any WS-I waters or Class I or Class It impounded reservoirs used as a source of drinking water 100 feet (v) Waters classified WS (other than WS-i), B, SA, ORW, HOW, or SB [from normal high water (or tide elevation)] 50 feet (vi) Any other stream, lake or impoundment 10 feet (vii) Any building foundation 5 feet (viii) Any basement 10 feet 3 (ix) Top slope of embankment or cuts of 2 feet or more vertical height 10 feet (x) Drainage systems (1) Interceptor drains 5 feet (11) Ground water lowering and surface drainage ditches 10 feet (xi) Any swimming pool 10 feet (xii) Ferrous sewer pipe with joints equivalent to water main standards, shall be used where these minimum separations cannot be maintained. The minimum separation shall however not be less than 25 feet from a private well or 50 feet from a public water supply well; A variance has been granted to allow SDR 13.5 Class 315 pipe in lieu of ferrous pipe within 100 feet of a private or water supply well. 13. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those that may be required by this Division, such as the construction of additional or replacement wastewater collection facilities. 14. Noncompliance Notification: The Permittee shall verbally report to a water quality staff member at the Mooresville Regional Office, telephone number 704-663-1699, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that render the facility incapable of adequate wastewater transport such as mechanical or electrical failures of pumps, line blockage or breakage, etc. b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at Telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Per Condition 1(2), Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 16. A variance has been granted by the Division on April 13, 2000 (modified .January 23, 2003) for the use of SDR 13.5 PVC pipe in lieu of ductile iron pipe within the 25-ft to 100-ft radius of private wells for pipe sizes less than 4 inches. In no case shall any sewer line be placed within 25-feet of a private well or 50-feet of a public well. 17. The pressure sewer lines permitted herein shall be designated "high priority" until such time that the contributing flow provides a velocity exceeding 2 feet per second. High priority lines must be inspected once every six months and cleaned as necessary. Permit WQ0016555 is hereby issued, this the 26th day of March, 2004 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION • 6,66„....„ T-Or Alan W. Klimek, P. E., Director Division of Water Quality By Authority of the Environmental Management Commission 4 rrmit No. WQ0016555 March 26, 2004 ENGINEERS CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of [968 linear feet of 2-inch pressure sewer to serve 11 residences along Pompano Place and Delray Drive, and the discharge of 2,090 GPD for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of this permit, the approved plans and specifications, and other supporting materials. Signature Registration No. Date Seal: If modifications to the design (that affect the permit) are not on the record drawings, please indicate them below or attach an additional sheet: The above Engineer's Certification must be completed and submitted to the address below with one (1) copy of the Record Drawings (Le., as -constructed plans) of the permitted facilities. This project shall not be considered complete and allowed to operate until this Engineer's Certification and the Record Drawings have been submitted. Any wastewater flow made tributary to the permitted facilities prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES DIVISION OF WATER QUALITY WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-16I7 5 North Carolina Department of En Michael F. Easley, Governor William G. Ross Jr., Secretary arttnerd and Natural Resources Alan W. Klimek, P.E., Director Coleco H. Sullins, Deputy Director Division of Water Quality July 21, 2004 Mr. Barry Shearin, P. E., Chief Engineer Charlotte -Mecklenburg Utilities 5100 Brookshire Blvd. Charlotte, North Carolina 28216 Subject: Application No, WQ0016555 Additional Information. Request Nantz Rd. (Arbor Place) CMUD Job No. 379-03-577 Pressure Sewers Sewer- Public Mecklenburg County Shearin: The Non -Discharge Permitting Unit has completed a preliminary engineering review of the subject application. Additional information is required before we can continue our review. Please address the attached items no later than August 20, 2004. Please be aware that you are responsible for meeting all requirements set forth in North Carolina rules and regulations. Any oversights that occurred in the review of the subject application package are still the responsibility of the applicant. In addition, any omissions made in responding to the above items may result in future requests for additional information. Please reference the subject permit application number when providing the requested information. Please provide a written response/explanation to each item to enable a quicker review. All revised information, including letters, calculations, revised drawing sheets, and revised pages of the specifications, should be signed, sealed, and submitted in duplicate to my attention at the address below. Additional comments may be forthcoming following a review of the requested information. Please note that failure to provide this additional information on or before the above requested date can result in your application being returned as incomplete. Non -Discharge Permitting Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 DENR Customer Service. Center An Equal Opportunity Action Employer Internet httplfh2o enr.s'tate.ttc.us/ndpu Telephone (919) 733-5083 Fax (919) 715-6048 Telephone 1 800 623-7748 50% tecycled/10% post-consurner paper If you have any questions regarding this request, please call me at (919) 733-5083, extension 375. You may also check the future status of this project online at http://h2o.enr.state.nc.uslbims/Reports/reportsPermits.htrl. Thank you in advance for your cooperation and timely response. A. Bennie Goetze, Jr., P. E. Environmental Engineer Non -Discharge Permitting Unit Attachment cc: Mooresville Regional Office, Water Quality Section Mr. Cooper Burton, P. E., W. K. Dickson & Co., Inc. Permit Application File WQ0016555 I Charlotte -Mecklenburg Utilities Nantz Rd. (Arbor Place) CMUD Job No. 379-03-577 Pressure Sewers Application Number WQ0016555 Review Comments July 21, 2004 General 1. Based on the A/E's certification in the Permit Application that all 15A NCAC 2H .0200 requirements regarding gravity sewers and force mains, and the Division of Water Quality's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 have been met, a review of these items has not been performed. It shall be the permittee's responsibility to ensure the plans and specifications meet the appropriate design criteria and rules. Final approval of these documents will not imply approval of any variance from these criteria unless specifically requested and granted. Failure to comply may result in penalties in accordance with North Carolina General Statute 143-215.6A--143- 215.6C, construction of additional facilities, and/or referral of the N.C. Professional Engineer to the licensing board. 2. Calculations a. Provide a downstream sewer analysis for the gravity line below the pressure system. b. The schematic shown in the model does not show the street names. Indicate the location of Arbor PI. with respect to the existing system. c. Provide documentation to support the number of simultaneous pump operations. Specifications 1. The grinder pump and wetwell specifications should be separate from the calculations. Provide a copy of the pump curve for the calculations. Low Pressure Sewer Customer Information 1. Detail - Sheet 8 a. Label the screened vent. b. Indicate the dimensions of the ballast concrete required.