Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0039715_Regional Office Historical File Pre 2018
Water Resources ENVIRONMENTAL QUALITY January 9, 2018 Kerry Avant, Senior Vice President H & H Homes, Inc. 2919 Breezewood Avenue, Suite 400 Fayetteville, NC 28303 ,ROY DOPER f 1 f � -Frovemor MICHAEL S. REGAN Secretary LINDA CULPEPPER Interim Director Subject: Permit No. WQ0039715 H & H Homes, Inc. Creek Park Subdivision Wastewater Collection System Extension Permit Lincoln County Dear Mr. Avant: In accordance with your application received December 22, 2017, we are forwarding herewith Permit No. WQ0039715 dated January 9, 2018 to the H & H Homes, Inc. (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. .This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition I1.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina-Iicensed Professional Engineer to the Iicensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you. have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. State of North Carolina L Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704 663 1699 If you need additional 'information concernit.g this matter, please contact Ori Tuvia at (704) 235-2190 ar via e-mail at ori.tuvia(ncdenr.gov. Sincerely, by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ cc: Dan Brewer (P.E.) (E-copy) Mooresville Regional Office Files Water Resources Central Files PERCS (E-copy) Page 2 of 8 Environmental Quality STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the H & H Homes, Inc. Lincoln County for the construction and operation of approximately 4,647 linear feet of 8-inch gravity sewer to serve 106 single family 3 bedrooms homes and 14,400 sgwire feet clubhouse as part of Creek Park Subdivision Development, and the discharge of 32,640 gallons per day of collected wastewater into the Lincoln County existing sewerage system, pursuant to the application received December 22, 2017, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ By authority of the Environmental Management Commission Permit Number: WQ0039715 Permit Issued: January 9, 2018 Page 3 of 8 SUPPLEMENT TO PERMIT COVER SHEET H & 1 Homes, Inc. is hereby authorized to: Construct, and then operate uponcernfication the aforementioned wastewater collection extension, The sewage and wastewater collected by this system shall be treated in the Killian. Creek Regional Wastewater Treatment Facility in accordance with. Permit Number NC0088722. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity SewerMinimum Design Criteria adopted February 12, 1996, as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the J'ermittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules, Construction and operation is contingent upon compliance with the Standard Conditions and any° Special Conditions identified below. I. SPECIAL CONDITIONS I) No flow in e cess of the quantity pert riled herein, 32,640 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow° has been submitted to and approved by the Division. [15A NCAC 02T.0304 (b)] II. STANDARD CONDITIONS This permit is not transferable. In the event there i a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval. of this request shall be considered on its rnerits and may or may not be approved, [15A NCAC 02T.0104; G,S 143-215.1(d3)] This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned 'herein. [15A NCAC 02T..0110] 3 This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [1.5A NCAC 02T .011.0 4. The wastewater collection facilities shall he properly maintained and operated at all t .e The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be mete [15A NCAC 02T ,0108(b):1: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. Page 4 of 8 b. - A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six months and inspections documented.. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with I5A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute § 143-215.1 C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. J. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable ofadequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Page 5 of 8 Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Foul' CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved forrn) can also be completed to show that the SSO was beyond control. [G.S. 143- 215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [l5A. NCAC 0217.0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form.. A complete certification is one where the formis fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Pemiittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the .applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form i.s fully executed and the supporting documents are provided as applicable. Supporting .documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DV[) disk) and are defined as the design drawings that are marked up or annotated with after construction information a.nd show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity', pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low° points in force mains with a pump cycle, and downstream sewer capacity- analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes to the project that do not result in noncompliance with this permit, regulations, or the Minimum. Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 1.0% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are Page 6 of 8 discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; I5A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes § 143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which maybe required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] Page 7 of 8 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: H . H HOMES, INC. PERMIT #: WQ0039715 PROJECT: CREEK PARK SUBDIVISION ISSUE DATE: JANUARY 9, 2018 This project shall, not be considered complete nor allowed to operate in accordance with standard Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation to the Regional Supervisor, Water Quality Regional Operations Section at the address noted in the page footer. Any wastewater flow made tributary to the wastewater collection system extension prior to completion. of this Certification shall be considered a violation of the permit and shall subject the Perrnittee to appropriate enforcement actions, The Perrnittee is responsible for tracking all partial certifications up until a final certification is received by the Division. A Final Certification ,shall. be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIF'€C:ATiON 1, the undersigned agent for the Perntittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Perrittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof, Printed Name. T itle Date ENGINEER'S CERT1VLC TJON 1, , as a duly registered Professional En ineer in the State of North Carolina, having been authorized to observe ([-] periodically, weekly, J full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T, the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina Professional Engineer's Seal wlsignature & date: Final Ej Partial (include description Certification :omments/Qualifiers (attueh ssary): NC DWR Water Quality Regional Operations Section 610 East Center Avenue, .Suit e30 oaresville, NC 28115 STATE OF NORTH CAROLINA COUNTY OF LINCOLN Permit No. CON /5 DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (di) and entered into this day of , y and between the North Carolina Environmental Management Commission, an agency of the S e of North Carolina, hereinafter known as the COMMISSION; and H & H HOMES, INC. , a corporation/general partnership registered/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: 1. The DEVELOPER is the owner of the certain lands Iying in LINCOLN County, upon which it is erecting and will erect dwelling units and other improvements, said development to be known as CREEK PARK (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, the (Unit Owners' Association) (hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with Iaw and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Resources has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. FORM: DEV 08-13 Page 1 of 2 FOR THE ENVIRONMENTAL MANAGEMENT CO l' l!dISSION —Hire'tmr, Division of" at:er Resourt 4. The DEVELOPER shall provide in the Declaration and Association 13ylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will. be maintained out ofthe common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part ofthe yearly budget. 6. In the event the common expense allocation and separate fund are not adequate for the construction,. repair, and maintenance of the Disposal. System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much ofthe Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a permit. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction; maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. N WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized. representative of the parties hereto on the day and year written as indicated by each of the parties named below: H& H HOMES, INC. ASSf T N 5 Name of DEVELOPER B:,�� (Signature' 6,vP Print N a FORM: DEV OS- l 3 Page 2 of 2 Res, woes State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Numbert(-59 I I (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: FI & H„Homes,. ximpany, municipality, BOA, utility, etc.) 2. Applicant type:Individual Corporation El General Partnership El Privately -Owned Public Utility Ej Federal El State/County El Municipal Ej Other 3, Signature authority's name: Kerry Avant per MA NCAC 02'F .0 I Q,(),(t) Title: Senior V.P. 4. Applicant's mailing address: 2919 Brcezewood Avenue, Suite 400 City: Fayetteville State: NC Zip: 283037_,_ 5. Applicant's contact information: Phone number: (910) 486-4864 Email Address: kerryavant@II.Ithomes.com II. PROJECT INFORMATION: 1. Project name: Creek Park Subdivision 2. Application/Project status: 4 Proposed (New Permit) 11 Existing Permit/Project If a modification, provide the existing permit number: WQ00and issued date: If new construction but part: of a master plan, provide the existing permit number: WQ00 3. County where project is located: 1...incoin 4. Approximate Coordinates (Decimal„Degrees): Latitude: 35...4664 Longitude: -.8..1,0336' 5. Parcel ID (if applicable): 34839, 3480L34840 & 54084 (or Parcel ID to closest downstream sewer) 111. CONSULTANT INFORMATION: 1. Professional Engineer: Dan E Brewer License Number: 17582 Firm: ESP Associates, P.A. Mailing address: :2 0 4 8 4 Chartwell Center Drive, Suite :D. City: Cornelius State:. NC Zip: 28031- Phone number: (704) 990-9428 Email Address: dbrewer@espassoeizites.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1.. Facility Name: Killian Creek WWTP Permit Number: NC 0088722 Owner Name: East Lincoln Sewer District V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): . Permit Numher(s): WQ System Wide Collection System Owner Name(s): Downstream (Receiving) Sewer Size: inch it Number(s) (if applicable): WQCS FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public lltili , has a Certificate of Public Convenience and Necessity been attached? 0 Yes QNo N/A 2. If the Applicant is a Developer of lots to be sold has a Developer's Operational and =.') been attached? pp p elo er's O _eratiunal r1 r�,entent )°(7EtM: I�E1�, Yes LNo ]NIA If the Applicant is a Home/Propert Owners' Association, has an Operational Agreement (FORM: NOA) been attached? ❑ Yes ©No;+INIA 4. Origin of wastewater: (check all that apply): ] Residential Owned. 0 Residential Leased School. / preschool / day care 0 Food and drink facilities Businesses / offices / factories Nature of w e Ej Retail (stores, centers, malls) ID Retail with food preparationlservice ® Medical ./dentalveterinary facilities 0 Church © Nursing Home 100 "?/© Domestic/Commercial % Comm ial % Industrial (See 15A NCAC 0'2T .0103(20)) tots there a Pretreatment Program in effect? 6. Has a flow reduction been approved under 15A NCAC 02T .01 14(t)? O Yes Y If yes, provide a copy of flow reduction approval utter 7. Summarize wastewater generated by project: Establishment Type (see 02T.OI I4(f)) Daily Design Flow O Car Wash 0 Hotel and/or Motels 0 Swimming Pool ,/Clubhouse 0 Swimming Pool/Filter Backwash 0 Other (Explain in Attachment) No No. of Units' Flow Single Family, 3 Bedroom 240 gal/day 106 25,440 GPD Clubhouse 50 gall00 sf gal/ gal/ gal/ gal/ 14,400 7,200 GPD a See L5A NCAC 02T ,01 14 [b),(d), tel(1) and (e)(2.1 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G,S; 42A-4), b Per 15A NCAC 02T .0114(e), design flow rates for establishments not identified [in table I5A NCAC 02T.01.141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. Wastewater generated by project: 32,640 GPD (per 15.'1 NCAC 021 .0114) Do not include future bows or previously permitted allocations If pennitted flow is zero, indicate why: Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line © Flow has already been allocated in Permit Number: Rehabilitation or replacement of existing sewer with no new flow expected © Other (Explain): FORM: FIFA 04-16 Page VII. GRAVITY SEWER DESIGN CRITERIA Applicable) - 02T .0305 & M ; . Summarize gravity sewer to be permitted: Size (inches) Length (feet) 8" 4,647 Material PVC ').). Section li & 111 of the MDC for Permitting of Gravity Sewers contains information related to design criteria • Section III contains information related to minimum slopes for gravity sewer(s) • Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VI1L PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mainsl: COMPLETE, FOR EACH PUMP STATION INCLUDED IN THIS PROJEC I I. Pump station number or name: _ 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with ,C 02T .0305(11)(1): El Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(13): • Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day • Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: El P• ortable power source with manual. activation, quick -connection receptacle and teleme4ry - 15A NCAC 02T .0305(h)(1 )(c) Of El P• ortable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): • It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station, If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel titneframes, shall be provided in the case of a multiple station power outage, FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS - (02B .0200 & I5A NCAC 02T .03050): 1. Does the project comply with all separations found in 15A NCAC 02T .03051,1) & (g) ' 15A NCAC 02T.0305D contains minimum separations thatihat shailbe rovided fbr sewer s stems: Setback Parameter* torrn sewers and other utilities not listed below (vertical) ater mains v 'cal -water over sewer includin&in benched trenc ains horizontal) Reclaimed water lines (vertical - reclaimed over sewer) eclaimed water lines (horizontal - reclaimed over sewer) **Any private or public water supply source, including any wells, Class II impounded reservoirs used as a source of drinking water S-1 waters of Class 1 or Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HOW, or SB from norma liih water (or tide elevation) and wetlands (see item 1X.2) 50 feet Yes Separation Required 24 inches 18 inches 10 feet 18 inches 2 feet 100 feet *Any other stream, lake, impoundment, or ground water lowering and surface drainage itches Any building foundation Any basement Tops1j of embankment or cuts of 2 feet or o e vertical heigh Drainage systems and interceptor drains Any swimming pools al earth grade (vertical) 10 feet 5 feet 10 feet 10 feet 5 feet 10 feet 6 inches • 15A NCAC 02T,030,5(g) contains alternatives where separations in 02T.0305(1) cannot be achieved. ). **Stream classifications can be identified using the Division's i\g' Surface Water Classifications weltpage If noncompliance with 02.1,0.105(1)or gt„ see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) » See the Division's draft separation requirements for situations where separation cannot be meet ). No variance is required if the alternative design criteria specified is utilized in design and construction • As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 0213 0200? ). This would include Trout Buffered Streams per I 5A NCA.(213,02.02, Yes El No No 4. Does the project comply with an individual 404 Permit or any 401 Certifications? 4 Yes U No • Wetland -related permits shall he requested, obtained, and adhered to for projects that impact wetlands or surface waters ) Information can be obtained from the 401 St.J3utfer Permitting Branch 5. Does project comply with I5A. NCAC 02T.0.105(s)1:6) (additional permits/certifications)? Yes El No Per 15A. NCAC 02T,010,5(c)(6), directly related environmental pennits or certification applications are being prepared, have been. applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NC AC 02T,0402„ "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to strearribanks that is subject to erosion that undermines or deteriorates the sewer. Yes No • lfyes, include an attachment with details for each line, including type (aerial line, size, tnaterial, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the perinitee's individual System -Wide Collection permit. FORM: ETA 04-16 Page 4 of .5 X CERTIFICATIONS: 1. Does the submitted system comply with 1A NC ',17 the Minimum .Design_ Ant fee,,,..M.ins„,llatest„.„ and the sr_Miniinum Poilm_critetitt No Yes ggj Non plicable? If No, complete and submit the Variance/Altemative Desi Request plication (VADC 10-14) and supporting documents for review, Approval of the request is required prior to sullutittld of tbeFat,Tack Application and supporting 2. Professional Engineer's Certification: 1*- b F. trewgr (Professional Engineer's name from Application Item 111.1.) ,attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — in accordance with General Statutes 143-21.5.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guiltyof a Class 2 misdemeanor, which may include afin.e not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3.„Applicant's Certification per 15A. NCAC 02T .0106(b): 1/16C_Pac--5 J.-r attest that this application for Authority's name & title from A.pplication. Item 1..3.) has been reviewed by me and is accurate and ,complete to the best of my knowledge. 1 understand that Wail required parts of this application are not completed and that if all required supporting documentation and attachtnerits are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. 1 will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application pack • .e are not completed. and that if all required supporting information and attachments are not included, this application 'package will be returned to me as incomplete. NOTE In accordance with General Statutes .143:11, A and 1.415,613, any person who knowingly makes any false statement, representation, or certification in any application package shall be ilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: _ Date: FORM: FTA 04-16 Page 5 of 5 Business Registration Division Page 1 of 1 North Carolina Elaine F. Marshall DEPARTMENT of THE Secretary SECRETARY of STATE PO Box 29622 Raieigh,NC 27626-0622 (919)314-5490 Click Here To: View Document Filings File an Annual Report Amend a Previous Annual Report Print a Pre -Populated Annual Report form Corporate Names Account Login Create Site Account Legal: H&H Homes Realty, LLC Prev Legal: H&H New Homes Realty, LLC Limited Liability Company information Sosld: Status: Annual Report Status: Citizenship: Date Formed: Fiscal Month: Registered Agent: Corporate Addresses 1479068 Current -Active Current Domestic 11/3/2015 Rostefter, Jack Reg Office: 2919 Breezewood Avenue Suite 400 Fayetteville, NC 28303 Reg Mailing: 2919 Breezewood Avenue Suite 400 Fayetteville, NC 28303 Company Officials All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20. https://www.sosnc.gov/Search/profcorp/11865970 9/1/2017 State of North Carolina Department of Environmental Quality Division of Water Resources Dit a ,rF .F �° E.aer r' e low Tracking/Acceptance for Sewer Extension Applications esou (VISE 04-16) Entity Requesting Allocation: Project Name for which flow is being, requested: Creek Park Subdiw ision - Phase I Afore than one FTSE rrr a: > r t atarc>r./f rar ca singl prr;ee stations ahmg the router, 'the proposed it astew3%ater flown. 1. Complete this section only a. \VVWTP Facility Narne: h. W WTP Fa_cPermit c, WWII' facility ns perniit:ted flow ner of the wastewater treatment plant.. 3.35 c➢. Estimated obligated Clow not yet tributary to the °WTP 1.255 e. 'WWTP facility's actual avg, flow f. Total flow for tspecific request 1.01.5 0.032 "Total actual and c bliwzated flows to the facility'` 2,27 'ercent of permitted floww used 67.7'?%u Complete this section for each pump station you are responsible for along the route of this proposed wastewater flown, t pump stations located bet. ww`een the proje Pump Station (Name or Number) 7 irin city, * nection point and the W\V 1 P: (A) (8) (C,) (D)-(i;+C) (F)=(A-D) Design Obligated, Average Daily Approx, Not Yet Total Current Flow** Current Avg. Tributary Flow Plus (t:irira ! pf), Daily Flow, Daily FlOW, Obligated A.vaita.ble MGD MGI:) MGD Flow Capacity*** 7,776 5.110 L655 1.l)C 2.715 ().3 ** Design Average Daily 1 1 factor (pi) not less than Z.a. *** A Planning Assessment Addendum shall he attached for each pump station located between the project connection point and the WWTI' where the Available Capacity is < U. pump station is defined as the maximum pumped flow that •gest pump taken out of service. ice. r rw is the firm capacity of the pup station divided by a pealing, Downstream Facility Name (Sewer): Lincoln Count y° Sew er System Downstream Permit Number: 149 FTSE 046 III. Certification Statement: I Donald V. Chamblee certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. 'DJ)/ Signing Official Signature Date Page 2 of 6 FTSE 04-16 PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section II where Available Capacity is < 0. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for % and MGD of the Available Capacity (E) in Pump Station ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately MGD per year; and that. c. A funded Capital Project that will provide the required planned capacity, namely is in design or under construction with planned completion in ; and/or d. The following applies: Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. Signing Official Signature Date Page 3 of 6 FTSE 04-16 Instructions for Flow Tracking/Acceptance form (FTSE) and Planning Assessment Addendum (PAA) Section I a. WWTP Facility Name: Enter the name of the WWTP that will receive the wastewater flow. b. WWTP Facility Permit #: Enter the NPDES or Non -Discharge number for the WWTP receiving the wastewater flow. c. WWTP facility's permitted flow, MGD: From WWTP owner's NPDES or Non -Discharge permit. d. Estimated obligated flow not yet tributary to the WWTP, MGD: This includes flows allocated to other construction projects not yet contributing flow to the collection system. Flows allocated through interlocal agreements or other contracts not yet contributing flow to the collection system are also included. For POTWs that implement a pretreatment program, include flows allocated to industrial users who may not be using all of their flow allocation. Please contact your Pretreatment Coordinator for information on industrial flow tributary to your WWTP. As of January 15, 2008 the POTW should have reviewed flow allocations made over the last two years and reconciled their flow records, to the best of their ability, so it is known how much flow has been obligated and is not yet been made tributary to the WWTP, in accordance with local policies and procedures employed by the reporting entity. e. WWTP facility's actual avg. flow, MGD: Previous 12 month average. f. Total flow for this specific request, MGD: Enter the requested flow volume. g. Total actual and obligated flows to the facility, MGD Equals [d + e + f] h. Percent of permitted flow used: Equals [(g / c)* 100] For example: On January 15 a POTW with a permitted flow of 6.0 MGD, reported to the Regional Office that there is 0.5 MGD of flow that is obligated but not yet tributary. The annual average flow for 2007 is 2.7 MGD. There is a proposed flow expansion of 0.015 MGD. The first Form FTSE submitted after January 15, 2008 may have numbers Iike this: c. = 6.0 MGD d. = 0.5 MGD e. = 2.7 MGD £=0.015MGD g. = 3.215 MGD h. = 53.6 % The next Form FTSE may be updated like this with a proposed flow expansion of 0.102 MGD: c. = 6.0 MGD d. = 0.515 MGD e. = 2.73 MGD f. = 0.102 MGD g. = 3.349 MGD h. = 55.8% Each subsequent FTSE form will be updated in the same manner. Page 4 of 6 FTSE 04-16 Section II List the pump station name or number and approximate pump station firm capacity, approximate design average daily flow (A) approximate current average daily flow (B), and the obligated, not yet tributary flow through the pump station (C) for each pump station that will be impacted by the proposed sewer extension project. Calculate the total current flow plus obligated flow (D=B+C) and the available capacity (E=A-D). Include the proposed flow for this project with other obligated flows that have been approved for the pump station but are not yet tributary (C). Firm capacity is the maximum pumped flow that can be achieved with the largest pump out of service as per the Minimum Design Criteria. Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) of not less than 2.5. If the available capacity (E) for any pump station is < 0, then prepare a planning assessment for that pump station if the system has future specific plans related to capacity that should be considered in the permitting process. Design Firm Average Pump Station Capacity Daily Flow (Name or Number) MGD (Firm / pf) Kaw Creek PS 0.800 0.320 Valley Road PS L895 0.758 Approx. Current Avg. Daily Flow, MGD (C) (D)=(B+C) (E)=(A-D) Obligated, Not Yet Total Current Tributary Flow Plus Daily Flow, Obligated Available MGD Flow Capacity* 0.252 0.080 0.332 -0.012 0.472 0.135 0.607 0.151 Page 5 of 6 FTSE 04-16 Planning Assessment Addendum Instructions Submit a planning assessment addendum for each pump station listed in Section II where available capacity is < 0. A planning assessment for Kaw Creek PS (see example data above) may be performed to evaluate whether there is significant likelihood that needed improvements or reductions in obligated flows will be in place prior to activating the flows from the proposed sewer extension project. If the system decides to accept the flow based on a planning assessment addendum, it is responsible to manage the flow without capacity related sanitary overflows and must take all steps necessary to complete the project or control the rate of flow to prevent sanitary sewer overflows. The planning assessment may identify a funded project currently in design or construction, or a planned project in the future not yet funded but in a formal plan adopted by the system. The system should carefully weigh the certainty of successful timely project completion for any expansion, flow management diversion or infiltration and inflow elimination projects that are the foundation of a planned solution to capacity tracking and acceptance compliance. For example: Given that: a. The proportion and amount of obligated, not yet tributary flow accounts for 24 % and 0.080 MGD of the committed flow in Pump Station Kaw Creek; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0.01 MGD per year; and that c. A funded capital project that will provide the required planned capacity, namely is in design or under construction with planned completion in ; and/or d. The following applies: The master plan and ten year capital plan contain recommended scope and funding for a capital project entitled Kaw Creek Pump Station upgrade with funding planned in July 2014. This project is planned to add 0.100 MGD to the firm capacity of the pump station by October 2015. Inclusion of this proposed capital project as a condition of this Flow Trackina/Acceptance for Sewer Extension Permit Application elevates this project's priority for funding and construction to be implemented ahead of the activation of obligated, not yet tributary flows in amounts that exceed the firm pump station capacities identified in Section II above. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant Iikelihood of over -allocating capacity in the system infrastructure. Page 6 of 6 FTSE 04-16 mUSGS U. IR, OIMOLCOICAL MUMMY 1 OS Togo FORM WSCAS 08-13 WATERSHED CLASSIFICATION ATTACHMENT FOR SEWER SYSTEMS Applicant Name Project Name H&H Homes, :I_ nci Creek Park Subdivision 'Professional. Engineer Name Engineering Firm Name Dan 'E Brewer P E1 ESP Associates,P::AT Location ID Name of Waterbody1 Flfiian-Cr County din oc In River Basin Cat Waterbody Stream Index No. 1 '.11.s:-2{95) c Waterbody Classification 1 J _J 1 r 1 If unnamed, indicate "unnamed tributary to X", where X is the named waterbody to which the unnamed tributary joins. 1 certify that as a Registered Professional Engineer in the State of North Carolina that 1 have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief. PE Seal, Signature and Date ***END OF FORM WSCAS 08-13 *** otill �•``p���FES51�j -r: Ar'17582 FORM: WSCAS 08-13 Pagel of1 SANITARY SEWER CALCULATIONS CREEK PARK SUBDIVISION Prepared for: H & H Homes, Inc. 2919 Breezewood Avenue, Suite 400 Fayetteville, NC 28303 Prepared by: ESP Associates, P.A. P.O. Box 7030 Charlotte, NC 28241 (803) 802-2440 Project Number: EO72.400 Original: September 1,2017 ESP Associates, P.A. NARRATIVE Creek Park Subdivision is a 170 lot single family subdivision situated on approximately 85 acres. Phase 1 is a 106 lot single family subdivision of approximately 27 acres. The property is situated north of the intersection of Drury Lane and N. Little Egypt Road. The development includes an approximately 40,000 s.f. amenity site. Wastewater Collection System Creek Park Subdivision Lincoln County, NC September 7, 2017 CHECK FLOW FROM VERDICT RIDGE TO NORTH OF COUNTY SCHOOLS Average Daily Flow estimate: Number of Dwellings: 170 Estimated Usage/capita: 240 GPD Pool/clubhouse usage: 7,200 GPD estimate Average Daily Flow: 48,000 GPD Average Flow at Site: Canopy Creek Killian Creek Verdict Ridge: Windsor Forest: Lift Station #21: Creek Park (From Above): Total: Existing Sanitary Sewer line: Pipe Size: Flow depth y: 50% Depth: Q=AV V=1.49/n*(Rh)2/3*51/2 Existing Sanitary Sewer line: Minimum slope used, s: Manning's n: Pipe Size: (Proposed) (Proposed) Allocated 36,480 GPD 14,160 GPD 147,480 GPD 17,280 GPD 11,250 GPD 48,000 GPD 274,650 GPD 0.42 CFS Current Approx. Flow 0 GPD 0 GPD 83,760 GPD 10,080 GPD 11,250 GPD 48,000 GPD 153,090 GPD 0.24 CFS 15 " From Attached Calculations 0.34 FT V= A= P= Q= 50% Full Capacity: Allocated Flow Depth: 50% Capacity Depth: OK (based on above flow) 0.0016 ft/ft 0.013 15" 2.11 fps 0.61 sf 1.96 ft 1.30 cfs 837,204 GPD 1.30 CFS 0.34 ft 0.625 ft CHECK FLOW FROM COUNTY SCHOOLS TO 30' Average Flow at Schools: North of Schools (From Above): Trilogy A: Trilogy B-C (Partial): Clubhouse: Welcome Center: Lincoln County Schools: Lincoln County Schools: Total: Existing Sanitary Sewer line: Pipe Size: Flow depth y: Existing Sanitary Sewer line: Minimum slope used, s: Manning's n: Pipe Size: ' GRAVITY AT TRILOGY Allocated 274,650 GPD 30,240 GPD 24,240 GPD 10,000 GPD 300 GPD 14,307 GPD 9,840 GPD 363,577 GPD 0.56 CFS Current Approx. Flow 153,090 30,240 24,240 0 300 14,307 9.840 232,017 0.36 15 " From Attached Calculations 0.36 FT V= A= P= Q= 50% Full Capacity: OK (based on above flow) 0.0022 ft/ft 0.013 15" 2.48 fps 0.61 sf 1.96 ft 1.52 cfs 981,709 GPD 1.52 CFS Allocated Flow Depth: 0.36 50% Capacity Depth: 0.625 ft ft GPD GPD GPD GPD GPD GPD GPD GPD CFS CHECK FLOW FROM 30" GRAVITY TO KILLIAN CREEK P5 (36" GRAVITY) Average Flow at Pump Station: Allocated Current Approx. Flow From Above: 363,577 GPD 232,017 GPD Trilogy B & C (Partial): 19,920 GPD 13,200 GPD Trilogy G&H: 36,000 GPD 36,000 GPD Trilogy F: 17,040 GPD 17,040 GPD From PS 15: 1,970,000 GPD 1,534,630 GPD Total: 2,406,537 GPD 1,832,887 GPD 3.72 CFS 2.84 CFS Existing Sanitary Sewer line: Pipe Size: 30 " From Attached Calculations Flow depth y: 1.108 FT OK (based on above flow) Existing Sanitary Sewer line: Minimum slope used, s: 0.0005 ft/ft Manning's n: 0.013 Pipe Size: 30 " V = 1.87 fps A = 2.45 sf P = 3.93 ft Q = 4.60 cfs 50% Full Capacity: 2,971,688 GPD 4.60 CFS Allocated Flow Depth: 50% Capacity Depth: 1.11 ft 1.250 ft CHECK FLOW FROM KILLIAN CREEK PS Average Flow at Pump Station: Allocated Current Approx. Flow From Above: 2,406,537 GPD 1,832,887 GPD Trilogy D: 104,640 GPD 0 GPD Trilogy E: 67,920 GPD 0 GPD Trilogy K: 12,000 GPD 0 GPD Total: 2,591,097 GPD 1,832,887 GPD 4.01 CFS 2.84 CFS Existing 30" Sanitary Sewer line: Pipe Size: 30 " From Attached Calculations Flow depth y: 0.50 FT OK (based on above flow) Minimum slope used, s: Manning's n: Pipe Size: 0.0123 ft/ft 0.013 30" V = 9.29 fps A = 2.45 sf P = 3.93 ft Q = 22.81 cfs 50% Full Capacity: 14,739,092 GPD 22.81 CFS Allocated Flow Depth: 50% Capacity Depth: 0.50 ft 1.250 ft Existing 36" Sanitary Sewer line: Pipe Size: 36 " From Attached Calculations Flow depth y: 1.01 FT OK (based on above flow) Minimum slope used, s: Manning's n: Pipe Size: 0.0006 ft/ft 0.013 36" V = 2.32 fps A = 3.53 sf P = 4.71 ft Q = 8.19 cfs 50% Full Capacity: 5,293,511 GPD 8.19 CFS Allocated Flow Depth: 50% Capacity Depth: 1.01 ft 1.500 ft Normal depth in a partially full circular culvert, Victo iguel Ponce, San Diego State University Page 1 of 3 CHECK FLOW FROM VERDICT RIDGE TO NORTH OF COUNTY SCHOOLS el06.php: Normal depth in a partially full ter culvert Formulas 2 (y/D} A (D2/8 (e _ sine) V = Q/A INPUT DATA: Select: Pipe diameter D: Discharge Q: Bottom slope S: Manning's n: SI units (metric) U.S, Customary units 1,25 0.42 efs J.0016 I .013 ft ft/ft INTERMEDIATE CALLS: Constant k: 1.486 Flow area A: 0,271 ft2 Wetted perimeter P: 1,373 ft Hydraulic radius R: 0.197 ft Relative depth y/D: 0.272 Froude number [based on y]: 0,468 OUTPUT: Flow depth y: 0.340 ft Flow velocity V: 1.549 fps Calculate Reset Your request was processed at 08:15:46 am on September 7th, 2017 (1709C)7 08:15:46 ]. Thank you for running onllnechannel_06, Please call again. (1408181 You created this PDF from en application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 9/7/2017 Normal depth in a partially full circular culvert, Victor Miguel Ponce, San Diego State University Page 1 of 3 CHECK FLOW FROM COUNTY SCHOOLS TO 30" GRAVITY AT TRILOGY onlinechanne106.php: Normal depth in a partially full circular culvert Formulas e 2 cos-1[1 - 2 (y/D) A = (D2/8) Se - sin0) P re = A/P ( k /n AR2 3Si / 2 INPUT DATA: Select: SI units (metric) U.S. Customary units Pipe diameter D: Discharge Q: Bottom slope S: Manning's n: 1.25 .56 .0022 013 ft ft/ft INTERMEDIATE CALCS: Constant k: 1.486 Flow area A: 0.297 ft2 Wetted perimeter P: 1.424 ft Hydraulic radius R: 0,208 ft Relative depth y/D: 0.291 Froude number [based on y]: 0.550 OUTPUTt Flow depth y: 0.363 ft Flow velocity V: 1.885 fps Calculate Reset Your request was processed at 08:25:00 am on September 7th, 2017 [170907 08:25:00 ]. Thank you for running onlinechannal_08. Plana call again. [1408181 You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com) 9/7/20l 7 Normal depth in a partially full circular culvert, Victor Miguel Ponce, San Diego State University Page 1 of 3 CHECK FLOW FROM 30" GRAVITY TO KILLIAN CREEK PS (36'" GRAVITY) oniinechannnI06µphp: Normal depth in a partially full circular culvert Formulas R = A/P AR 2 V = Q/A INPUT DATA: Select: SI units (metric) U.S. Customary units Pipe diameter D: Discharge Q: Bottom slope S: Manning's n: 3.72 .0005 cfs .©13 ft ft/ft INTERMEDIATE CALLS: Constant k: 1.486 Flow area A: 2.100 ft2 Wetted perimeter P: 3.642 ft Hydraulic radius R: 0.576 ft Relative depth yID: 0.443 Froude number [based on y]: 0.296 OUTPUT: Flow depth y: 1,108 ft Flow velocity V: 1.770 fps Calculate Reset Your request was processed at 08:28:41 am on September 7th, 2017 [ 170907 08:28:41 ]. Thank you for running onllnerhannel_ 06. Plana call again, [140618] You created this PDF from an application that is not licensed to print to novaPDF printer (http;l/www,novapdf..comj 9/7/20 l 7 Normal depth in a partially full circular culvert, Victor Miguel Ponce, San Diego State University Page 1 of 3 CHECK FLOW FROM KILLIAN CREEK PUMP STATION (30" DIAMTER PIPE) onlincchanne106.php: Normal depth in a partially full circular culvert Formulas 2(y/D) A = (D2/B) (e - sine) P re R = A/P V Q/A INPUT DATA: Select: Pipe diameter D: Discharge Q: Bottom slope S: Manning"s n: SI units (metric) U.S„ Customary units 2.5 4.01 cfs .0123 ft/ft INTERMEDIATE CALLS; Constant k: 1.486 Flow area A: 0.702 ft2 Wetted perimeter P: 2.322 ft Hydraulic radius R: 0.302 ft Relative depth yfD: 0.200 Froude number [based on y]: 1.421 OUTPUT Flow depth y: 0:501 ft Flow velocity V: 5.711 fps Calculate Reset Your request was processed at 08:31:32 am on September 7th, 2017 [ 170907 08:31:32 1. Thank you for running onlinechannel 06. Please call again. 1140618] You created this PDF from an application that is not licensed to print to novaPDF printer (htt+:,//wy .novapdf.corn) 9/7/2017 Normal depth in a partially full circular culvert, Victor Miguel Ponce, San Diego State University Page 1 of 3 CHECK FLOW FROM KILLIAN CREEK PUMP STATION (36" DIAMETER PIPE) onlinechanne106.php: Normal depth in a partially full circular catlw Formulas 2 (y/D) 1 sine) P = r6 R = A/P (k/n) AR2/3S112 V = 4/A NPIJT DATA: Select: SI units (metric) U.S. Customary units Pipe diameter D: Discharge Q: Bottom slope S: Manning's n: 4.©1 .013 ©006 cfs ft ft/ft INTERMEDIATE CALCS: Constant k: 1.486 Flow area A: 2.097 tt2 Wetted perimeter P: 3.719 ft Hydraulic radius R: 0.564 ft Relative depth y/D: 0,337 Froude number [based on y]: 0.334 OUTPUT: Flow depth y: 1.012 ft Flow velocity V: 1.911 fps Reset Your request was processed at 08:38:11 am on September 7th, 2017 [ 170907 08:38: Thank you for running onllnechannel_06. Please call again. 11406181 You created this PDF from an application that not licensed to print to novaPDF printe httwwvr.n(vapd 9/7/2017 Wastewater Collection System Creek Park Lincoln County, NC September 1, 2017 By: RIG Checked: DB CANOPY CREEK - SEWER CAPACITY DESIGN CRITERIA 50% CAPACITY FROM TO SLOPE (FT/FT) HOUSES FLOW (GPD) FLOW (CF5) MANNING'S N PIPE SIZE (IN) V (FPS) A (SF) P (FT) Q (CFS) Q (GPD) MH-1 EX-MH 0.0605 170 40,800 0.0631 0.013 8 8.54 0.17 1.05 1.49 963,043 „'', a MI-1-2 MH-1 0.0941 170 40,800 0.0631 0.013 8 10.65 0.17 1.05 1.86 1,201,055 MH-3 MH-2 0.0970 106 25,440 0.0394 0.013 8 10.81 0.17 1.05 1.89 1,219,422 MH-4 MI-I-3 0.0265 96 23,040 0.0357 0.013 8 5.65 0.17 1.05 0.99 637,369 MH-5 MH-4 0.0146 88 21,120 0.0327 0.013 8 4.19 0.17 1.05 0.73 473,091 MH-6 MH-5 0.0091 80 19,200 0.0297 0.013 8 3.31 0.17 1.05 0.58 373,498 MH-7 MH-6 0.0104 76 18,240 0.0282 0.013 8 3.54 0.17 1.05 0.62 399,287 *MI-8 MH-7 0.0134 75 25,200 0.0390 0.013 8 4.02 0.17 1.05 0.70 453,232 MFI-9 •MH-8 0.0138 70 16,800 0.0260 0.013 8 4.08 0.17 1.05 0.71 459,947 MH-10 MH-9 0.0186 63 15,120 0.0234 0.013 8 4.73 0.17 1.05 0.83 533,980 MH-11 MH-10 0.0145 55 13,200 0.0204 0.013 8 4.18 0.17 1.05 0.73 471,468 MH-12 MH-11 0.0045 52 12,480 0.0193 0.013 8 2.33 0.17 1.05 0.41 262,648 MH-13 MH-12 0.0045 44 10,560 0.0163 0.013 8 2.33 0.17 1.05 0.41 262,648 MH-14 MH-13 0.0045 44 10,560 0.0163 0.013 8 2.33 0.17 1.05 0.41 . 262,648 MH-15 MH-14 0.0450 3 9,170 0.0142 0.013 8 7.36 0.17 1.05 1.29 830,566 MH-16 MH-15 0.0350 1 240 0.0004 0.013 8 6.49 0.17 1.05 1.13 732,491 M H-34 MH-15 0.0045 32 7,680 0.0119 0.013 8 2.33 0.17 1.05 0.41 262,648 MH-35 MH-34 0.0045 24 5,760 0.0089 0.013 8 2.33 0.17 1.05 0.41 262,648 MH-36 MH-35 0.0040 13 3,120 0.0048 0.013 8 2.20 0.17 1.05 0.38 247,627 MH-37 MH-36 0.0040 11 2,640 0.0041 0.013 8 2.20 0.17 1.05 0.38 247,627 M14-38 MH-37 0.0040 2 480 0.0007 0.013 8 2.20 0.17 1.05 0.38 247,627 MH-39 MH-38 0.0045 7 1,680 0.0026 0.013 8 2.33 0.17 1.05 0.41 262,648 MH-40 MH-39 0.0045 3 720 0.0011 0.013 8 2.33 0.17 1.05 0.41 262,648 MH-33 MH-14 0.0525 2 480 0.0007 0.013 8 7.95 0.17 1.05 1.39 897,114 MH-32 •MH-8 0.0200 1 240 0.0004 0.013 8 4.91 0.17 1.05 0.86 553,711 MH-30 MH-3 0.0060 5 1,200 0.0019 0.013 8 2.69 0.17 1.05 0.47 303,280 MH-31 MH-30 0.0060 2 480 0.0007 0.013 8 2.69 0.17 1.05 0.47 303,280 MH-17 MH-2 0.0060 64 15,360 0.0238 0.013 8 2.69 0.17 1.05 0.47 303,280 ,. w m n MH-18 MI-17 0.0112 64 15,360 0.0238 0.013 8 3.67 0.17 1.05 0.64 414,359 MH-19 MH-18 0.0422 64 15,360 0.0238 0.013 8 7.13 0.17 1.05 1.24 804,312 MH-20 MH-19 0.0212 64 15,360 0.0238 0.013 8 5.05 0.17 1.05 0.88 570,080 MH-21 MH-20 0.0150 36 8,640 0.0134 0.013 3 4.25 0.17 1.05 0.74 479,528 MH-22 MH-21 0.0150 34 8,160 0.0126 0.013 8 4.25 0.17 1.05 0.74 479,528 MH-23 MH-22 0.0150 30 7,200 0.0111 0.013 8 4.25 0.17 1.05 0.74 479,528 MH-24 MH-23 0.0150 24 5,760 0.0089 0.013 8 4.25 0.17 1.05 0.74 479,528 MH-25 MH-24 0.0200 21 5,040 0.0078 0.013 8 4.91 0.17 1.05 0.86 553,711 MH-26 MH-25 0.0450 13 3,120 0.0048 0.013 8 7.36 0.17 1.05 1.29 830,566 MH-27 MH-26 0.0500 8 1,920 0.0030 0.013 8 7.76 0.17 1.05 1.35 875,494 MH-28 MH-27 0.0550 5 1,200 0.0019 0.013 8 8.14 0.17 1.05 1.42 918,226 MH-29 MH-28 0.0200 1 240 0.0004 0.013 8 4.91 0.17 1.05 0.86 553,711 MH-41 MH-20 0.0250 14 3,360 0.0052 0.013 8 5.49 0.17 1.05 0.96 619,068 MH-42 MH-41 0.0150 6 1,440 0.0022 0.013 8 4.25 0.17 1.05 0.74 479,528 MH-43 MH-42 0.0440 3 720 0.0011 0.013 8 7.28 0.17 1.05 1.27 821,286 *Amenity area sewer service connects between MN-32 and MH-8. Design Is not complete but assumed 120' x 120' Recreational Facility, 50 gal/100 sq. ft. 7,200 GPD OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK OK Resources Quality February 1, 2017 Chris Henderson Engineering Associate Lincoln County Public Works 115 West Main Street Lincolnton, NC 28092 Subject: Killian Creek WWTP, NPDES # NC0088722 Residential Flow Reduction Lincoln County Dear Mr. Henderson: ROY COOPER Governor MiCHA,EL S. REGAN Secretory S. JAY Z MMERMAN Director RE IVEDDE,NRJdWR DEC 20 2017 Water Resources Permitting Section On January 29, 2007 the Division of Water Quality (now Division of Water Resources) granted a flow reduction for residential flow to Middle Forney Creek WWTP (NC0074012). Middle Forney Creek has been decommissioned and the NPDES permit rescinded. The flow previously being treated at Middle Forney Creek WWTP is now being treated at Killian Creek WWTP. All areas currently served by Kilian Creek WWTP and conveyed through pump stations # 15 and # 37 were included in the analysis done for the flow reduction granted in 2007. Based upon the data provided by the County for the 2007 flow reduction, the Division of Water Resources hereby approves the use of 80 GPD per residential bedroom, with a minimum of 160 gpd for one and two bedroom units in all applicable non -discharge permit applications to Killian Creek WWTP (NC0088722). Flow shall be incremented by 80 gpd for each bedroom above two. Regardless of the adjusted design daily wastewater flow rate, at no time shall the wastewater flows exceed the effluent limits defined in the NPDES permit for the treatment facility of exceed the capacity of the sewers downstream of nay new sewer extensions or service connection(s). The granting of this flow reduction does not prohibit the Division from reopening, revoking, reissuing and /or modifying the flow reduction as allowed by the laws, rules, and regulation contained in 15A NCAC 02T, NCGS 143-215.1, or as needed to address changed in State and/or Federal regulations with respect to wastewater collection systems, protection of surface waters and/or wastewater treatment. State of North Carolina I Environmental 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 919-707-91100 If you have any questions, please contact me at (919) 807-6383, or via email at deborah.gore@ncdenr.,gov. Sincerely, for S. Jay Zimmerman Director, Division of Water Resources by Deborah Gore, Supervisor Pretreatment, Emergency Response and Collection Systems Branch Cc: Mooresville Regional Office, Water Quality Regional Operations Central Files: NC0088722 PERCS (electronic copy) ESP ESP Associates, P.A. NCDEQ/DWR Water Quality Section — Wastewater Branch PERCS UNIT 1617 Mail Service Center Raleigh, NC 27699-1636 SUBJECT: Creek Park Subdivision — Phase I 695 N. Little Egypt Road Application for Sewer Extension Lincoln County, NC Ladies and Gentlemen, August 23, 2017 ESP Associates has prepared the attached Fast -Track Application for Gravity Sewer Extension. Included in the application is listed below: • Fast -Track Sewer System Extension Application (FTA 04-16) with documentation • A check for the application fee in the amount of $480 • Flow Tracking/Acceptance for Sewer Extension Application (FTSE 04-16) • Site Maps • Developer's Operational Agreement (DEV 08-13) This project involves a proposed 8-inch gravity sanitary sewer to serve I 70 residential units. The proposed sewer will discharge into the existing County's gravity sewer trunk line along Killian's Creek with an estimated average daily flow of 41,200 gpd. Please do not hesitate to contact me if you have any questions or comments. Sincerely, ESP Associates, P,A. eAt.4fre-'" Dan Brewer, RE. Senior Project Manager RECEIN/FnirDV+IR DEC?0 2.011 Waiteesourcos Perm action 2048.4 Currier Drive Suiic I) - Cornelius, ,NC 28031 L800.060,7317 704..990.9428 tax 704.581,49SO vivvvv,espiassociutes.coin, DEPARTMENT PHONE COUNTY OF LINCOLN, NORTH CAROLINA 1 1 5 WEST MAIN STREET, 2 V$ FLOOR CITIZENS CENTER, LINCOLNTON. NORTH CAROLINA 28092 UBLIC WORKS (704) 736-8497 FAX (704) 736-8499 WWW.LINCOINCOUNTY,ORC December 12, 201.7 ESP Associates, P. A. Attn: Dan Brewer 20484 Chartwe11 Center Drive. Suite D Cornelius, NC 28031 RE: Creek Park Subdivision Pfrase 1 1t=lr. Brewer, This letter is provided in response wastewater treatment i. (the 'Project"). Lincoln County (the' Creek Wastewater Treatment Plant to treat the dog grant approval for the Project.,, subject est, dated August 17, 2017, for flow acceptance r° #rwe C.reh P trl Subdivision Phase 1 Development -age daily flow capacity at its Killian s requested, and does coridnionailr however, to the terms and conditions belong: 1.. The amount of flow requested for the Project is 1 flow of 32,640 gallons per day of additional flow at 240 gallons per day per home into LS-37, and 2, For the NCL)I: NR Permits. Permit #NC 0088722, The sewer c.olleeti District, Permit #V QCS 00149); and 106 lots and TM: oral NCDE-NR approved reduced ate of er treatment coin Colt an Creek WWTP, er and Sewer 3. The County shall not be named as the Perrtaittee. on NCD[NR system applications. You :must - make the application to NCD.ENR in your own name for the System: and 4. Acceptance of the System and iransf following: System to the C"ounty is subject to the a. A complete final inspection and approval of the System by the County, and receipt of other applicable documentation requested by the Count, and b. Approval of the System by NCDPNR, and proof provided to the County of a valid penilit. issued by NCDENR with. an Authorization to Construct: (ATC): and c. Initiating construction of the Project within two years of the date of this conditional approval You must. notify the Lincoln County Public Works Depaartment in writing when construction of the l'rc iect is irtitiatecl; rand d, The County contint domes wastewater as requested at tore tune all ether conditions precedent have been satisfied. This acceptance and allocation of flow shall only be effective upon your compliance with all of the above terms and conditions and the County providing an acknowledgment that you have complied with all of the above terms and conditions. Included in this mailing is the Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE — 04/16) with the County's portion completed. If you have any questions, please do not hesitate to call me at 704-736-8497. Sincerel , Chris Henderson Engineering Associate Cc: File Permit Number Central Files: APS WQ0039715 Permit Tracking Shp SWP 1/9/2018 Program Category Status Project Type Non -discharge Active New Project Permit Type Version Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions 1,00 Primary Reviewer orituvia Coastal SWRuIe Permitted Flow 32,640 Facility Permit Classification Individual Permit Contact Affiliation Facility Name Creek Park Subdivision Location Address Owner Major/Minor Region Minor Mooresville County Lincoln Facility Contact Affiliation Owner Name H & H Homes Inc Dates/Events Owner Type Non -Government Owner Affiliation Kerry Avant 2919 i3reezewood Ave Fayetteville NC 28303 Orig issue App Received 119/2018 12/22/2017 Regulated Activities Draft Initiated Scheduled Issuance Subdivision Wastewater collection Outfall Public Notice Issue Effective Expiration /9/2018 1/9/2018 Requested /Received Ev Additional information requested 1/9/18 Additional information received 1/9/18 Waterbody Name Sireamindex Number Current Class Subbasin