HomeMy WebLinkAboutWQ0038997_Regional Office Historical File Pre 2018IN° er°ResoU Resources:
[prvir ONP°Ef lA_ (1MJnt4!Y
Thompson G. Daniel III, Member/Manager
The Springs at Westport Club, LLC
PO Box 9007
Greensboro, NC 27429
Subject:
August 3, 2017
Permit No. WQ0038997
The Springs at Westport Club , LLC
The Springs at Westport Club -- Phase III
Wastewater Collection System Extension Permit
Lincoln County
Dear Mr, Daniel:
R. Y COOPER
MICHAEL, S. REGAN
sroviwy
S. JAY ZIMMERMAN
arecor
In accordance with your application received January 23, 2017 and additional information received on.
June 14, 2017 we are forwarding herewith Permit No. WQ0038997, dated August 3, 2017, to The Springs
at Westport Club, LLC (Permittee) for the construction and operation upon certification of the subject
wastewater collection system extension. This permit shall be effective from the date of issuance until
rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter and
supplement shall be considered a part of this permit and are therefore incorporated therein by reference,
Please pay ;particular attention to the following conditions contained within this permit:
Condition 1,1: The Operational Agreement between the Permittee and the Environmental
Management Commission is incorporated herein by reference and shall be a condition
of this permit. Noncompliance with the terms of the Operational Agreement shall
subject the Permittee to all sanctions provided by North Carolina General Statutes §143-
21.5.6A to §143-215.6C for violation of or failure to act in accordance with the terms and
conditions of this permit. A copy of the Articles of Incorporation, Declarations, and
Bylaws that have been properly filed shall be submitted with certification prior to
operation.
Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained
in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system
permit issued to the Permittee.
It shall be responsibility of the Permittee to ensure that the as -constructed project meets the appropriate
design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina
General Statute §143-215.6A through §143-215.6C, construction of additional or replacement
wastewater collection facilities, 'and/or referral of the North Carolina -licensed Professional Engineer to
the licensing board.
State of North Carolina I F.nv rcrrttateartai Quality I %VurcrResources
(17 Mail Service Center I Raleigh, North Carolina 27699.16 i 7
919.8074300
The Sp1JnXSntW(o�1)w'/C1vb,UI
xuf,vs1]`2D17
Permit No. WQW38997
/fany parts, requirements, wrlimitations contained imrhispann|taeonacceptab|e,youhaveUe right to
reqUe.st an adjudicatory hearing upon written request within 30 days following receipt of this permit. This
request must 6einthe form ofuwritten petition, conforming toChapter 15U8nfNorth Carolina General
Statutes, and filed wkh the Office of Administrative Hearings, 6714 Mail 3emirc Center, Raleigh, NC
27699-6y14. Unless such demands are made, this permit shall befinal and binding,
If you need additional information concerning this matter, please contact ChristVn Fertenbwugh P.E,at
(929)807-63lZorvia e-mail o\chhstymoden,.guv.
Sinmrmk\
,
for S,Jay Zimmerman, P.G.
Director, Division of Water Resources
byDeborah Gore, Supervisor
Pretreatment, Irnergency Response, Collection System Unit
Enclosure: Operational Agreement
M. LarhsaK4.[oks,P.E./e|ccn/niccopy—
Mooresv|heBegionm|Offioe,VVaterQoa/itySertionHeQiooa|Operatkmn*
Tommy Drum, OR[ Killian Creek VVVVTP Lincoln County (electronic copy)
Water Resources Central Files: VVCNO38997
PERCS (electronic copy)
Page 2of 8
Environmental .
Quality
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to
The Springs at Westport Club, LLC
for the construction and operation of approximately 1,720 linear feet of 3-inch pressure sewer and
approximately 105 linear feet of 2.5-inch pressure sewer; as well as 48 simplex grinder pump stations with
on -site audible and visual high water alarms, to serve 48 single family residential units (all 3-bedroom
homes) as part of the Springs at Westport Club, Phase III project, and the discharge of 11,520 gallons per
day of collected domestic wastewater into Lincoln County's existing sewerage system, pursuant to the
application received January 23, 2017, and additional information received on June 14, 2017 and in
conformity with the project plans, specifications, and other supporting data subsequently filed and
approved by the Department of Environmental Quality and considered a part of this permit.
This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified
conditions and limitations contained therein.
Ls„
for S. Jay Zimmerman, P.G.
Director, Division of Water Resources
By Authority of The Environmental Management Commission
Permit Number: WQ0038997
Permit Issued: August 3, 2017
• Treatment Facility: Killian Creek WWTP (NC0088722)
Page 3 of 8
SUPPLEMENT PERMIT COVER SWEET
The Permittee is hereby authorized to:
Construct, arid then operate Upon certification the aforementioned wastewater collection extension,
Permitting of this project does not constitute an acceptance of any part of the project that does not meet
15A NCA[ZT: the Division's Gravity Sewer Minimum Design Criteria adopted Februory1J, 1998as
applicable, and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and
Force Mains adopted June 1' 2000as applicable, unless apecKica|h/mentioned herein. Division approval
is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in
the application, It shall be the Permittee's responsibility to, ensure that the as-COnStrUcted project rneets
the appropriate design criteria and ,u|e$.
Com4ruction and operation is contingent LIP011 compliance with the Standard Conditions and any Special
Conditions identified below,
1. SPECIAL CONDITIONS
1. The Operational Agreeuwnt between the Permittee and the Environmental Management Commission
is incorporated herein by reference and shall be a condition of this permit. Noncompliance with the
terms of the Operational Agreement shall subject the Permittee to all sanctions provided by North
Carolina General Statutes §143'215.6Ato §143-215.GCfor violation oforfailure tnact in accordance
with the terms and conditions of this permit, 8 copy of the Articles o/ Incorporation, Declarations,
and Bylaws that have been properly filed shall be submitted with certification priorto operation.
2. Per the submitted downstream oewercapachyana|ysb,itappeauthatsmvem|pipevo|edtiesame|ess
than 2 feet per second throughout the pipe network, and are thereby defined as "high -priority sewer,"
per I58 NCA[ 02T0402. In accordance with 15A NCA[ 02T.0403, high -priority sewers shall be
inspected. by the permittee or its representative at least once every six -months and inspections shall
bedooumented.
H. STANDARD CONDITIONS
l. This pennit shall not be transferable, in the event there is o desire for the wastewater collection
facilities to change ownership, or there is a narne change of the Permittee, a formal permit request
shall besubmitted tothe Division accompanied bydmcumoentation,fromthe parties involved, and
other supporting materials as may be appropriate. The approval of this request shall be considered
nn its merits and may Vrmay not be approved, (15ANCACO2T.8104,- G.S. I43'215.1/d3\J
2. This permit shall become voidable unless the wastewater collection facilities are constructed in
accordance with the conditions of this permit; 15A NCAC Z-C the Division's Gravity Sewer Minimum
Design Criteria adopted February 12,I996axapplicable; the Division's Minimum Design Criteria for
theFast'TrackPermhdngofPompSietionxandForcek4ainsad"ptedJune1,lOOOasappUcab|e|and
other supporting materials unless specifically mentioned herein. /15ANCACO2T.0I101
3. This permit shall be effective only with respect to the mature and volume of wastes described in the
application and other supporting data, [15ANCACO2T/011O]
Page 4 of 8
i
4. The wastewater collection facilities shall be properly maintained and operated at all times. The
Permittee shall maintain compliance with an individual system -wide collection system permit for the
operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual
permit is not required, the following performance criteria shall be met: [15A NCAC 2T .0108(b)]
a. The sewer system shall be effectively maintained and operated at all times to prevent discharge
to land or surface waters, and to prevent any contravention of groundwater standards or surface
water standards.
b. A map of the sewer system shall be developed and shall be actively maintained.
c. An operation and maintenance plan including pump station inspection frequency, preventative
maintenance schedule, spare parts inventory and overflow response has been developed and
implemented.
d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365
days per year). Pump stations that are connected to a telemetry system shall be inspected at
least once per week.
e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are
documented.
f. A general observation of the entire sewer system shall be conducted at least once per year.
g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance
with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina
General Statute §143-215.1C.
h. A Grease Control Program is in place as follows:
1. For public owned collection systems, the Grease Control Program shall include at least
biannual distribution of educational materials for both commercial and residential users and
the legal means to require grease interceptors at existing establishments. The plan shall also
include legal means for inspections of the grease interceptors, enforcement for violators and
the legal means to control grease entering the system from other public and private satellite
sewer systems.
2. For privately owned collection systems, the Grease Control Program shall include at least bi-
.annua! distribution of grease education materials to users of the collection system by the
permittee or its representative.
3. Grease education materials shall be distributed more often than required in Parts (1) and (2)
of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows.
i. Right-of-ways and easements shall be maintained in the full easement width for personnel and
equipment accessibility.
j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three
years with exception of the map, which shall be maintained for the life of the system.
Page 5 of 8
Noncompliance Notification:
The Permittee shall report by telephone to a water resources staff member at the Wilmington
Regional Office, telephone number (910) 796.72:1.5, as soon as possible, but in no case, more than 24
hours, following the occurrence or first knowledge of the occurrence of either of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable
of adequate wastewater transport, such as mechanical or electrical failures of pumps, line
blockage or breakage, etc.; or
b. Any SSO and/or spill over 1,000 gallons; or
c, Any SSO and/or spill, regardless of volume, that reaches surface water
Voice mail messages or faxed information is permissible, it this shall not be considered as the Initial
verbal report. Overflows and spills occurring outside normal business hours may also be reported to
the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300.
Persons reporting any of the above occurrences shall file a spill report by completing and submitting
Part 1 of Forrn CS-SSO (or the most current Division approved form) within five days following first
knowledge of the occurrence. This report must outline the actions taken or proposed to he taken to
ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved
form) can also be completed to show that the SSO was beyond control. [GS. 143-215.1C(a1)]
Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to
interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater
to ttie surface waters of the State, 115A NCAC 02T,01,08(b)j
7. Upon completion of construction and prior to operation of these permitted facilities, the completed
Engineering Certification form attached to this permit shall be submitted with the required supporting
documents to the address provided on the form. A complete certification is one where the form is
fully executed and the supporting documents are provided as applicable. Any wastewater flow made
tributary to the wastewater collection system extension prior to completion of this Engineer's
Certification shall be considered a violation of the permit and shall subject the Permittee to
appropriate enforcement actions,
if the permit is 'issued to a private entity with an Operational Agreement, then a copy of the Articles
of incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately
filed with the applicable County's Register of Deeds office shall be submitted with the certification.
A complete certification is one where the form is fully executed and the supporting documents are
provided as applicable, Supporting documentation shall include the following:
a. One copy of the project construction record drawings (plan & profile views of sewer lines & force
mains) of the wastewater collection system extension. Final record drawings should be dear on
the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are
marked up or annotated with after construction information and show required buffers,
separation distances, material changes, etc.
b. Changes to the project that do not result in non-compliance with this permit, regulations, or the
MViinirnum Design Criteria should be clearly identified on the record drawings, on the certification
in the space provided, or in written summary form.
Page 6 of 8
V'iorto
Certification (Final or Partial): Permit modifications are required for any changes resulting in
non-compliance with this permit (including pipe length increases of 10% or greater, increased flow,
pump station design capacity design increases of 5% or greater, and increases in the number/type of
connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to
the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit.
Please note that variances to the Minimum Design Criteria should be requested and approved during
the permitting process prior to construction. After -construction requests are discouraged by the
Division and may not be approved, thus requiring replacement or repair prior to certification &
activation. [15A NCAC 02T .0116]
8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's
Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until
corrected. If there is an unforeseen obstacle in the field where al! viable solutions have been
examined, a slope variance can be requested from the' Division with firm supporting documentation.
This shall be done through a permit modification with fee. Such variance requests will be evaluated
on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting
the construction certification. [ 15A NCAC 02T.0105(n)]
9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of
the wastewater collection facilities. [15A NCAC 027 .0116]
10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's
Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design
Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as
applicable; and other supporting materials may subject the Permittee to an enforcement action by
the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C,
construction of additional or replacement wastewater collection facilities, and/or referral of the North
Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 027
.0108(b-c)]
11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the
creation of nuisance conditions, the Permittee shall take immediate corrective action, including those
as may be required by this Division, such as the construction of additional or replacement facilities.
[15A NCAC 02T .0108(b)]
12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes,
rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local
government agencies which have jurisdiction or obtaining other permits which maybe required by the
Division or any other Federal, State, of Local government agencies. [G.5.143-215.1(b)]
13..The Permittee shall provide for the pump station and force main the following items:
a. Pump Station Reliability [15A NCAC 02T.0305(h)(1)]:
1. Pump stations, except when exempted by Subparagraph (j)(2) of 15A NCAC 027.0305,
shall be designed with multiple pumps such that peak flow can be pumped with the
largest pump out of service.
Page 7 of 8
Q'
2, A standby power source or purnp is required at all pump stations except for those pump
stations subject /oSubparagraph (j)(2)o/I5AW[ACO2T.O905. Controls shall beprovided
\mautomatically activate the standby source and signal aoalarm condition,
l As an alternative to Part (c) for pump stations with an average daily design flow less tharl
15,000 gallons per day as calculated using 15A NCAC 02"1'.0114, a portable power source
or pumping capability may be utilized. It shall be demonstrated to the Division that the
portable source is owned or contracted by the penwi10ee and bcompatible with the
station, |fthe Portable Power source mrpumpbdedicated toMultiple pumpStations, an
ova|ontion of all the pump stations' storage capacities and the rotation schedule of tile
portable power source. orpump, including travel dmefrnmes,shall beprovided |nthe case
Of Multiple station power outage.
4. As an alternative to Part (i) for pump or vacuum stations connecting a dmO|e building to
an alternative scwcrxysiem' wet well storage requirements shall be documented to
provide 24-hours' worth u[wastewater storage or, exceed thegreatest power outage
over the last three years or the documented response time to replace a failed pump,
whichever is greater. Documentation shall be required pursuant to the permit
application,
b. All pump stations designed for two pumps ormore shall have tclemetrysyoken to provide
,emote notification ofa problem condition to include power failure and high water alarm. [15A
c. High water audio and visual alarm, 115ANCACO2T.0305(h)
d. Pumpstations shall have a permanent weatherproof sign stating the Pump station identifier, 24-
houremeqpencynumberandinmirucUmms tocall incase ofemergency. Simplex pump mrvacuum
stations serving asiogie-fami|y residence shall have o placard orsticker placed inside the control
panel with a24'bnuremergency contact number. [15ANCACO2T.0305(h)(2)]
e, Screened vents for all wet wells, [15A NCAC 02T.0305(h)(3)]
The Public shall berestricted access cathe site and equipment. [15ANCACO2TJ0305(h)yV]
Air relief valves shall he provided at all high points, along force mains where the vertical distance
Page 8 of 8
ENGINEERING CERTIFICATION
Permittee: The Springs at Westport Club, LLC
Permit No: WQ0038997
Project: The Springs at Westport Club Phase HI
Issue Date: August 3, 2017
County: Lincoln
This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit
until the Division has received this Certification and all required supporting documentation, which includes:
• One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of
the wastewater collection system extension. Final record drawings should be clear on the plans or on digital
media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after
construction information and show required buffers, separation distances, material changes, etc.
Permit modifications are required for any changes resulting in non-compliance with this permit. A detailed
description for partial certifications should be attached to this form along with any certification comments.
Certification should be submitted in a manner that documents the Division's receipt. The Permittee is responsible
for tracking all partial certifications up until a final certification is received.
PERMITTEE'S CERTIFICATION
I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the
applicable standards & requirements, the Professional Engineer below has provided applicable design/construction
information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system
permitted herein or portions thereof.
Printed Name, Title
Signature Date
ENGINEER'S CERTIFICATION
1, as a duly registered Professional Engineer in the State of North Carolina, having
been authorized to observe (0 periodically, ❑ weekly, ❑ full time) the construction of the project name and
location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and
diligence was used in the observation of the following construction: approximately 1,720 linear feet of 3-inch
pressure sewer and approximately 105 linear feet of 2,5-inch pressure sewer; as well as 48 simplex grinder pump
stations with on -site audible and visual high water alarms, to serve 48 single family residential units (all 3-bedroom
homes) as part of the Springs at Westport Club, Phase Ili project, and the discharge of 11,520 gallons per day of
collected domestic wastewater into Lincoln County's existing sewerage system, and in conformity with the project
plans, specifications, supporting documents, and design criteria subsequently filed and approved. I certify that the
construction of the above referenced project was observed to be built within substantial compliance and intent of
the approved plans and specifications.
North Carolina Professional Engineer's Seal w/signature & date:
❑ Final ❑ Partial (include description)
Send the Completed Form & Supporting Documentation to the Following Address:
DWR WATER QUALITY PERMITTING SECTION
WASTEWATER BRANCH — PERCS UNIT
1617 Mail Service Center
Raleigh, NC 27699
STATE OF NORTH CAROLINA
COUNTY OF Lincoln
Permit No. U3ic3, Y699 3-
DEVELOPER'S OPERATIONAL AGREEMENT
This AGREEMENT made pursuant to G.S. 143-215.1 (di) and entered into this 9lh day of
September, 2D16 , by and between the North Carolina Environmental Management
Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and
The Springs atWeslportC4ub,Lie , a corporation/general partnership registered/licensed to do
business in the State of North Carolina, hereinafter known as the DEVELOPER.
WITNESSETH:
1. The DEVELOPER is the owner of the certain lands lying in Lincoln County, upon
which it is erecting and will erect dwelling units and other improvements, said development to be known
as The Springs at Westport Club. Phase 1N (hereinafter the Development).
2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment
works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve
the Development on said lands.
3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143-
215.1 to construct, maintain, and operate the Disposal System.
4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements
and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter
47C or 47F of the North Carolina General Statutes.
5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the
Declaration, the (Unit Owners' Association) me Springs at Westport Club (hereinafter
Association), a non-profit corporation organized and existing under and by the virtue of the laws of the
State of North Carolina, for the purpose, among others, of handling the property, affairs and business of
the Development; of operating, maintaining, re -constructing and repairing the common elements of the
lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues
and assessments to provide funds for such operation, maintenance, re -construction and repair.
6. The COMMISSION desires to assure that the Disposal System of the Development is properly
constructed, maintained and operated in accordance with law and permit provisions in order to protect the
quality of the waters of the State and the public interest therein.
NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties
hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows:
I. The DEVELOPER shall construct the Disposal System in accordance with the perinit and plans and
specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate
and maintain such systems and facilities in accordance with applicable permit provisions and law.
2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association
until construction has been completed in accordance with the permit and approved plans, and the staff of
the Division of Water Resources has inspected and approved of the facilities. In order to change the name
of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The
request must include a copy of the Association Bylaws and Declaration.
3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility
for the operation and maintenance of its Disposal System until a permit has been reissued to the
DEVELOPER's successor.
FORM: DEV 08-13 Page 1 of 2
4. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and
appurtenances thereto are part of the common elements and shall thereafter be properly maintained and
operated in conformity with law and the provisions of the permit for co.nstruction, operation, repair, and
maintenance of the system and facilities.. The -Declaration and Bylaws shall identify the entire wastewater
treatment, collection and disposal system as a common element which will receive the highest priority for
expenditures by the Association except for .Federal„ State, and local taxes and insurance,
5. The DEVELOPER shall provide in the ,Declaration and Association -Bylaws that the Disposal System
be maintained out of the common expenses. In order to assure that there shall be funds readily available to
repair, maintain or construct the Disposal System, beyond the routine operation and maintenance
expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common
expenses. Such fund shall be separate front the routine maintenance funds allocated for the facility and
shall be part of the yearly budget,
6. In the event the conunon expense allocation and separate fund are not adequate for the construction,
repair, and maintenance of the Disposal System, the .Declaration and Association Bylaws shall provide for
special assessments to cover such necessary costs. There shall be no limit on the amount of such
assessments., and the Declaration and Bylaws shall provide that such special assessments can be made as
necessary at any time.
7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city,
town, village, county, water and sewer authorities, or other unit of government shall hereinafter become
available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the
existing and future wastewater of the Development to be accepted and discharged into said governmental
system, and shall convey or transfer as much of the Disposal System and such necessary easements as the
governmental unit may require as condition of accepting the Development's wastewater,
Recognizing that it would be contrary to the public interest and to the public health, safetyand welfare for
th.e Association to enter into voluntary dissolution without having made adequate provision for the
continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER„ shall
provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without
first having transferred its said system and facilities to some person, corporation or other entity acceptable
to and approved by the COMMISSION by the issuance of a permit.
9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any
permit issued by the COMMISSION to the DEVELOPER for the construction, mainten.ance, repair and
operation of the Disposal System,
10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is
filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the
Association.
IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized
representative of the parties hereto on the day and year written as indicated by each of the parties named below:
FOR THE ENVIRONMENTAL
GEMENT COMMISSION
rq
S. Jay Zimmerman, PG,
t .
\ Director, Division of Water Resources.
The Springs al Westport Glob, LLG
Name of DEVELOPER
Print Mitte. and Title
Date)
FORM: DF,V 08-13
Page 2 of 2