HomeMy WebLinkAboutWQ0037096_Regional Office Historical File Pre 2018.11 NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory John E. Skvarla, III Governor Secretary June 19, 2014 Thompson G. Daniel III, Member/Manager Westport Lakeside No. 3 LLC P.O. Box 9007 Greensboro, NC 27429-0007 Subject: Permit No. WQ0037096 Westport Lakeside No. 3 Wastewater Collection System Extension Lincoln County Dear Mr. Daniel: In accordance with your application received April 15, 2014, and additional information received on June 17, 2014 we are forwarding herewith Permit No. •WQ0037096, dated June 19, 2014, to Westport Lakeside No. 3 LLC for the construction andoperation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter and supplement shall be considered a part of this permit and are therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T.0403 or any individual system -wide collection system permit issued to the Permittee. It shall be responsibility of the Westport Lakeside No. 3 LLC to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and fled with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding.. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Phone: 919-807-63001 Internet: www.ncwaterqualiiy.org An Equal opportunity 1 Affirmative Action Empbyer — Made in part by recycled paper Westport Lakeside No. 3 LLC Westport Lakeside No. 3 WQ0037096 If you need additional information concerning this matter, please contact Sarah Bass at (919) 807-6310 or via e-mail at Sarah.Bass@ncdenr:gov. Sincerely, for Thomas A. Reeder Division of Water Resources by Deborah Gore, Supervisor Pretreatment, Emergency Response, Collection System Unit enclosure: Operational Agreement cc: Larissa M. Coles, P.E. (electronic copy) Mooresville Regional Office, Water Quality Section Regional Operations (electronic copy) Don Chamblee, Public Works Director; East Lincoln County Sewer District (electronic copy) Water Resources Central Files: WQ0037096 PERCS (electronic copy) AWA NCDENR STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION' DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Westport Lakeside No. 3 LLC Lincoln County for the construction and operation of approximately 852 linear feet of 2-inch pressure sewer; approximately 1,337 linear feet of 2.5-inch pressure sewer; approximately 660 linear feet of 4-inch pressure sewer as well as 39 simplex grinder pump stations with on -site audible and visual high water alarms, to serve 39 single family residences (all three -bedroom homes) as part of the Westport Lakeside No. 3 project, and the discharge of 9,360 gallons per day of collected domestic wastewater into the East Lincoln County Sewer District's existing sewerage system, pursuant to the application received April 15, 2014, and additional information received on June 17, 2014 and in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. Permit issued this the 19th day of the June, 2014. for Thomas A. Reeder Division of Water Resources By Authority of The Environmental Management Commission Permit Number: WQ0037096 8 SUPPLEMENT TO PERMIT COVER SHEET Westport Lakeside No. 3 LLC is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the East Lincoln County Sewer District's Wastewater Treatment Facility (NC0088722) prior to being discharged into the receiving stream. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum. Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, MOO as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. I. SPECIAL CONDITIONS 1. The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and shall be a condition of this permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to.all sanctions provided by North Carolina General Statutes §143-215.6A to §1.43-215.6C for violation of or failure to act in accordance with the terms and conditions of this permit. A copy of the Articles of Incorporation, Declarations, and Bylaws that have been properly filed shall be submitted with certification prior to operation. Page 2 of 5 II. STANDARD CONDITIONS 1. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the. Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. • 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for theoperation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented, f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 213 .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is In place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi-annual distribution of 'grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. Page 3 of 5 i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for.a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. Noncompliance Notification: The Permittee shall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number 704-663-1599, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 7. Per 15A NCAC 27.0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Permit modifications are required prior to certification (Final or Partial) and are required for any changes resulting in non-compliance with this permit (including but no Iimitied to pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), or regulations. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. 8. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 9. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C. Page4of5 10. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 11. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 28 .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 12. The Permittee shall provide for the pump station and force main the following items: a. Pump Station Reliability: 1. Pump stations, except when exempted by Subparagraph (j)(2) of 15A NCAC 02T.0305, shall be designed with multiple pumps such that peak flow can be pumped with the largest pump out of service. 2. A standby power source or pump is required at ail pump stations except for those pump stations subject to Subparagraph (j)(2) of 15A NCAC 027.0305. Controls shall be provided to automatically activate the standby source and signal an alarm condition. 3. As an alternative to Part (c) for pump stations with an average daily design flow less than 15,000 gallons per day as calculated using 15A NCAC 02T.0114, a portable power source or pumping capability may be utilized. It shall be demonstrated to the Division that the portable source is owned or contracted by the permittee and is compatible with the station. If the portable power source or pump Is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. 4. As an alternative to Part (ii) for pump or vacuum stations connecting a single building to an alternative sewer system, wet well storage requirements shall be documented to provide 24- hours worth of wastewater storage or, exceed the greatest power outage over the last three years or the documented response time to replace a failed pump, whichever is greater. Documentation shall be required pursuant to the permit application. b. All pump stations designed for two pumps or more shall have a telemetry system to provide remote notification of a problem condition to include power failure and high water alarm. c. High water audio and visual alarm. d. Pump stations shall have a permanent weatherproof sign stating the pump station identifier, 24-hour emergency number and instructions to call in case of emergency. Simplex pump or vacuum stations serving a single-family residence shall have a placard or sticker placed inside the control panel with a 24- hour emergency contact number. e. Screened vents for all wet wells. f. The public shall be restricted access to the site and equipment. g• Air relief valves shall be provided at all high points along force mains where the vertical distance exceeds ten feet. 13. The Permittee shall maintain on hand for immediate installation an adequate supply of spare, fully operational pump units of each type used in the system. Page 5 of 5 !• CERTIFICATION Permittee: Westport Lakeside No. 3 LLC Project: Westport Lakeside No.3 Permit No. WQ0037096 Issue Date: June 19, 2014 This project shall not be considered complete nor allowed to operate until the Division has received this Engineer's Certification and all required supporting documentation. Therefore. it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. NOTE: If the permit is issued to a private entity with an operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable Countv's Register of Deeds office shall be submitted with the certification. PERMITTEE'S CERTIFICATION I, , the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. ENGINEER'S CERTIFICATION Partial ❑ Final 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the subject project for the Permittee, hereby state that to the best of my abilities, due care and diligence was used in the observation of the following construction: approximately 852 linear feet of 2-inch pressure sewer; approximately 1,337 linear feet of 2.5-inch pressure sewer; approximately 660 linear feet of 4-inch pressure sewer as well as 39 simplex grinder pump stations with on -site audible and visual high water alarms, to serve 39 single family residences (all three -bedroom homes) as part of the Westport Lakeside No. 3 project, and In conformity with the project plans, specifications, and other supporting documents subsequently filed and approved. 1 certify that the construction of the above referenced project was observed to be built within substantial compliance and intent of the approved plans and specifications. North Carolina Professional Engineer's Seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION TO THE FOLLOWING ADDRESS NCDENR / DWR / Water Quality Permitting Section Wastewater Branch — PERCS Unit 1617 Mali Service Center Raleigh,NC 27699 DWR Use Only: Flow from this project is tributary to: NC0088722 • STATE OF NORTH CAROLINA COUNTY OF Lincoln Permit No. i Q t:]C- 3- 0 9 L DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (di) and entered into this sth day of April, 2014 , by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and Westport Lakeside No. 3 LLC , a corporation/general partnership registered/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNES SETH: 1. The DEVELOPER is the owner of the certain lands lying in Lincoln County, upon which it is erecting and will erect dwelling units and other improvements, said development to be known as Westport Lakeside No. 3 Single Family (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F ofthe North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, the (Unit Owners' Association) Westport Lakeside Home Owner's Association (hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction and repair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality ofthe waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions and law. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Resources has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPERRs successor. FORM: DEV 08-13 Page I of 2 • 4. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater' treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance, 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such Rind shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. 6. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit may require as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of a permit. 9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by. the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: FOR THE ENVIRONMENTAL MAMENT COMM ISSIO 1�� Thomas A. Reeder, Director Division of Water Resources LP k.0J-2,o tA (Date) Westport Lakeside No, 3 LW Name of DEVELOPER By: (Signature) Thompson G. Daniel ill, Manager Print Name and Title 419113 • (Date) FORM: DEV 08-13 Page 2 of CERTIFICATION Permittee: Westport Lakeside No. 3 LLC Project: Westport Lakeside No. 3 RECEiVEDIDENRIDWR MAR ¶020M Water Quality Permitting Section Permit No. WQ0037096 issue Date: June 19, 2014 This project shall not be considered complete nor allowed to operate until the Division has received this Engineer's Certification and all required supporting documentation. Therefore. it is highly recommended that this certification be sent_in a manner that providesjiroof of receipt by the Division. NOTE: If the permit Is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County s Register of Deeds office shall be submitted with the certification. PERMrTTEE'S CreriFiCAT1oN i, % on,ysi•,kl 6. the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permlttee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printecf Name, Title /'j.,yll—' /1247. Signature The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. .3-i31 Date ENGINEER'S CERTIFICATION 1i [Partial ❑ Final 1, 1_14)—.1 6P� M. t _Ot.- is , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, ❑ weekly, ❑ full time) the construction of the subject project for the Permittee, hereby state that to the best of my abilities, due care and diligence was used in the observation of the following construction: approximately 852 linear feet of 2-inch pressure sewer; approximately 1,337 linear feet of 2.5-inch pressure sewer; approximately 660 linear feet of 4-inch pressure sewer as well as 39 simplex grinder pump stations with on -site audible and visual high water alarms, to serve 39 single family residences (all three -bedroom homes) as part of the Westport Lakeside No. 3 project, and in conformity with the project plans, specifications, and other supporting documents subsequently filed and approved. I certify that the construction of the above referenced project was observed to be built within substantial compliance and intent of the approved plans and specifications. North Carolina Professional Engineer's Seal, signatureogkd> ,,, al A x S Y ii g 1111/1Nliilllilltii�\\ SEND THIS FORM & SUPPORTING DOCUMENTATION TO THE FOLLOWING ADDRESS NCDENR / DWR / Water Quality Permitting Section Wastewater Branch— PERCS Unit 1617 Mail Service Center Raleigh, NC 27699 DWR Use Only: Flow from this project is tributary to: NC0088722 a 2" SDR-21 RIYATE LOW -E SEWERLINE Larissa M. Coles, PE 1701-1 Burke Road Shelby, North Carolina 28152 PUONE: 704482-7883 MOBILE: 704-692-4952 FAX: 704-487-6088 EMAIL: kolea(aymcgianiscole .corn UN1 REVIEW colAiENTs H0OT Rea* maws H kls Hco=T wept OGIA,OENTS PHASING OF oi EX1opSIc*1 WATER s SEVIER ASEULTS description Reylsons WESTPORT LAKESIDE NO. 3, LLC 3.38 N. ELM. ST., SUITE 320 GREENSB©R©, N.C.27405 (336) 255-1498 aWner 2/13/4 5/12/t4 8/8,/14 7/3/14 11/7/14 03/05/15 date WESTPORT LAKESIDE NO. 3A SINGLE FAMILY project title WATER AND SEWER AS —BUILT PLAN 1311-4 project no 11/07/14 date C-15 sheet no„ 15 of 20 1 N 660 LF 4 'FRWATE LOW RE SEWIERLIRE 1 11 ` I <\ \\ \\ Sy \) ti \l I I / �` \� `\ I\ i\� / 1 /!/[flN I I / / ) t 1 i\l )0am \ \ D spy C5 4V4 WATER AND SEWER AS --BUILT PLAN SCALE t = IDO' i z • Larissa M. Coles, PE 1701-1 Burke Road Shelby, North Cava[ina 28152 PHONE: 704.482-7883 MOBILE: 704-692-4952 FAX: 704-487-6088 EMAIL: 1coles@mcginnlscoles.com A a3 A A no. REVIEW ocikkERTs Nam kmER MEW ODVIIII111S 4{cooT R his PHASIIy0 OF fiki ERE(9oN *Am & sEIR AsstLTS description 2/13/14 5/12/14 5/8/14 7/3/14 11/7/14 03/05/15 date Revisions WESTPORT LAKESIDE NO.3, LLC 338 N. ELM STD SUITE 320 CREENSBORO, N.0 27405 (336) 255-1498 oViner WESTPORT LAKESIDE NO. 3A SINGLE FAMILY project title WATER AND SEWER AS -BUILT ELAN sheet title 1311-4 project no 11/07/14 date C-16 sheet no.15 of 20 Sifford, Barbara From: Bass, Sarah Sent: Tuesday, March 31, 2015 12:21 PM To: Sifford, Barbara; Love, Barry F Subject: Partial Certification of WQ0037096 Attachments: Partial Certification.pdf Attached is the partial certification for WQ0037096 (Westport Lakeside No. 3) of approximately 660 linear feet of 4-inch pressure sewer (total permitted) and approximately 447 linear feet of 2-inch pressure sewer (of 852 linear feet permitted) as well as 8 simplex grinder pump stations with on -site audible and visual high water alarms, to serve 8 single family residences (all -three bedroom homes) of the 39 single family homes originally permitted. Thanks, Sarah Morrison Bass N.C. Dept. of Environment and Natural Resources Division of Water Resources Pretreatment, Emergency Response and Collection Systems Unit (PERCS) 1617 Mail Service Center, Raleigh, NC 27699-1617 (919) 807-6310; fax (919) 807-6489 httk://portat ncdenr. org/veb/wq/swp/ps/pret E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. Before printing this email, please consider your budget and the environment. If you must print, please print only what you need and save ink with the free Eco-Font. 1