HomeMy WebLinkAboutWQ0035325_Regional Office Historical File Pre 2018 (2)North Caro Beverly Eaves Perdue Governor NCDENR ina Department of Environment and Natural Resources Division of Water Quality Coleen H. Sullins Director Mr, Burns Whittaker, Director of Public Works Lincoln County 115 West Main Street Lincolnton, NC 28092 Dear Mr. Whittaker, May 6, 2011 Dee Freeman Secretary Subject: Permit No, WQ0035325 Airlie Industrial Park Wastewater Collection System Extension Lincoln County, North Carolina In accordance with your complete application received 'on April 25, 2011, we are forwarding herewith Permit No.. WQ0035325 dated May 6, 2011 for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and !imitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0493 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional C fit ce Location 610 East centerAve . Suite 301 Mooresville, NC 28115 Phone: (704) 663-1599 'ti Fax: (704) 563-6040 \ Customer Service. 1-877-623-6748 Internet: www. ncwaterouality.orq ,one ,orthCarofna 'aturally w s,nc,e rwww.wwwwwwwrwdzAwintWf. Cwnct Crw,^w.,rrnor r,,zr, r Mr. Whltt. Page 2 May 5, 2C11 In accordance with the provisions of Article 21 of Chapter 143,General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 3,880 linear feet of 8 inch gravity sewer, 870 linear feet of 4-inch force main, a 150 gallon per minute pump stations (with duplex pumps, on -site audible and visual high water alarm, and a permanent generator with ATS), and the discharge of 72,000 gallons per day of domestic wastewater in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Lincoln County WWTP (NPDES Permit No, NC0088722) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of Lincoln County. Lincoln County must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and the collection system permit WQCS00149. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1508 of North Carolina General. Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. Sincerely, r Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, '1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting. data. 3. - The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. t 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee,, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5, Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. y. A copy of the construction record drawings shall be maintained on The by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit, 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track. Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina Genera! Statutes §143- 215.6A through §143-215.6C. in the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government. agencies (local, state andfederal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B 0200 and 15A NCAC 2H .0500, Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following; a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; ar b. Any failure of a pumping station or sewer Vine resulting in a by-pass directly to receiiviwaters without 'treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part 1 of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 6th day of May, 2011. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0035325 3 Fast Track Engineering Certification Permit No. WQ0035325 May 6, 2011 Owner/VVQCS/WWTP Barry McKinnon Lincoln County 115 West Main Street, 2" Floor Lincointon, NC 23092 PE David Richmond McGill Associates, PA 1240'h 19u'h Street Lane, NW Hickory, NC 28603 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or n written summary form, Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CEFRT$F1CATION D Partial Final , as a duty registered Professional Engineer in the State of North Carolina, having been authorized to observe periodically, weekly, El full time) the construction of Airlie industrial Park, a Lincoln County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other .supporting materials. 'North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received_ Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. c� ill ASSOCIATES April 7, 2011 Mr. Rob Krebs Surface Water Protection Supervisor North Carolina Division of Water Quality 610 E. Center Avenue Mooresville, North Carolina 28115 Dear Mr. Krebs: RECE":./'v« o" DIVISION vy R12 sINP'S ON sMO'iRESVILL F;.:G!0NAL OFFICE QUALIT RE: Fast Track Permit Application Airlie Industrial Park Lincoln County, North Carolina Please find enclosed for your review and approval one (1) original and one (1) copy of the Fast -Track Application for the Gravity Sewers, Pump Stations, and Force Mains, one (1) color copy of a quad sheet, a one (1) Watershed Classification form for the above referenced project. Please also find enclosed a check in the amount of $480 to cover the application fee. The project includes the installation of approximately 3,880 linear feet of 8-inch diameter gravity sewers, one (1) wastewater pumping stations, and 870 linear of 4-inch diameter force main to serve the Proposed Airlie Industrial Park. The design of the project has been prepared in accordance with NCDWQ's minimum design criteria for gravity sewer lines. If you have any questions during your review or require further information regarding this project, please do not hesitate to contact us at (828) 328-2024. Sincerely, McGIL TES DAVID E. RICHMOND Senior Project Manager DER Enclosures Cc: Burns Whittaker, Lincoln County F:110.01415\Design PhaselCorrespondencelNCDENR-Fast_Track_4-07-2011.doc .Engineering Planning m Finance McGill Associates, P.A. • P.O. Box 1136, Hickory, NC 28603 • 1240 19th St. Lane NW, Hickory, NC 28601 Office: 828-328-2024 • Fax: 828-328-3870 Cl tVED WATER r2 : t ,At.lT' Dep irtment of Environ State of North Carolina nt and Natural Resources Division of Water Quality FAST -TRACK APPLICATION (FTA i 2/07 ) \ITV SEWERS, PUMP STATIONS, AND FORCE MAINS (Pressure. & Va. cuu n sewer systems are not to he included as part of tins application package) INSTRUCTIONS: Indicate that you have included/addressed the following list of required application package items by checking the space provided next to each applicable item. Failure to submit all required items will lead to your application being returned as incomplete. Forms are available from the web site or by calling the Regional Office serving your county: http://h2o.enrstate.nc. us/peres/Collection % 2OSystems/CollectionSystemApplications.html A. Application Form - Submit one original and one copy of the completed and appropriately executed application form. The application should include a project narrative describing the final build -out design (i.e, system and/or pump station to ultimately serve 500 homes, but flow for only 100 homes being requested now), For modifications, clearly explain the reason for the modification (i,e. adding another phase, changing line size/length, etc,). Only include the modified information in this permit application - do not duplicate project information that has already been included in the original permit. Any changes to this form will result in the application being returned, The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed plans and s ecifications unless ou res and NO to item B 13 Separate applications should be made for non-contiquous sewer systems. Application Fee - Submit a check in the amount of $480 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). Checks shall be dated within 90 days of application submittal. C. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately -owned public utility, submit two copies of the Certificate of Public Convenience and Necessity (CPCN) which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a CPCN has not been issued, provide two copies of a letter from the North Carolina Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area is contiguous to an existing franchised area, and/or that franchise approval is expected. The project name in the CPCN or letter must match that provided in Item A(2)a of this application. D D. Operational Agreements -. Submit one original and two copies of a properly executed operational agreement, as per 15A NCAC 02T .0115, if the application is submitted by a private applicant and will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparcels, etc.) that will be sold to another entity. If the applicant is a home or property owners association, use Form HOA 02/03. If the applicant is a developer, use Form DEV 02/03, EVEN IF THE PROJECT MAY BE TURNED OVER TO A MUNICIPALITY UPON COMPLETION, FORM DEV 02/03 IS REQUIRED. E. Downstream Sewer, W1NTF Capacity and Flow Tracking/Acceptance — FORM FTSE 10/07 (Flow Tracking/Acceptance for Sewer Extension Permit Applications) is required with every application. The applicant (and owners of downstream sewers, pump stations and/or treatment facilities submitting FORM FTSE-10/07) certifies that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving treatment plant, and that the flow from this project will not cause capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving wastewater treatment plant Where the applicant is not the owner of the downstream sewer, submit two copies of FORM FTSE 10/07 from the owner of the downstream sewer and owner of the WWTF, if different. The flow acceptance indicated in FORM FTSE-10/07 must not expire prior to permit issuance and must be dated Tess than one year prior to the application date. Submittal of this application and FORM FTSE-1O/07 indicates that owner has adequate capacity and will not violate G.S. 143-215.67(a). Intergovernmental agreements or other contracts will not be accepted in lieu of project -specific FTSE 10/07, Z Q. Map — Submit an 8,5-inch by 11-inch COLOR copy of a USGS Topographic Map of sufficient scale to identify the entire project area and the closest surface waters. Each map or maps must show the location of the sewer line and pump stations and be of reproducible quality. Include a street level map showing the downstream connection point, and the permit number for the downstream sewer, if known. FTA 12/07 G. Stream Classifications — Watershed Classification Attachment (Form WSCAS-12/07) If any portion of the sewer system project is within 100 feet of any surface water or wetlands, the Watershed Classification Attachment may need to be completed. A variance must be requested for encroachment within required setbacks or buffers pursuant to 2T ,0305 (f) and be indicated in Item B-13 with supporting documentation/justification provided H Environmental Assessments — If this project is subject to an Environmental Assessment (EA) [15A NCAC 01C], this application cannot be used. Send the project application on the most current version of Form PSFMGSA to the Design Management Unit, 1633 Mail Service Center, Raleigh, NC 27699-1633, Applications cannot be accepted until a Finding of No Significant Impact (FONSI) or Environmental Impact Statement (EIS) has been issued, A copy is to be submitted with that permit application Flow Direction — Many wastewater treatment systems are entering into agreements for regionalization efforts and emergency treatment capacity Paris of the system are installed so that the wastewater flow can be directed to more than one treatment facility. If this is the case with this project, please indicate in B(12) and give the permit number of the second treatment facility. Certifications — Section C The application must be certified by both the applicant and the design engineer who is a North Carolina Registered Professional Engineer (PE), The applicant signature must match the signing official listed in Item A(1b), The PE should NOT certify the application if he/she is unfamiliar with 15A NCAC Chapter 2T, the Gravity Sewer Minimum Design Criteria (most recent version) and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (most recent version), as applicable to the project. THE COMPLETED FTA 12/07 APPLICATION PACKAGE, INCLUDING ALL SUPPORTING DOCUMENTS AND $480 FEE, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS Asheville Regional Offlce Fayetteville Regional Office ooresville Regional Office Raleigh Regional Office on Regional Office 2090 US Highway 70 Swannanoa, North Carolina 28778 (828) 296-4500 (828) 299-7043 Fax 225 Green Street Suite 714 Fayetteville, North Carolina 28301-5094 (910) 433-3300 (910) 486-0707 Fax 610 E. Center Avenue Mooresville, North Carohna 28115 (704) 663-1699 (704) 663-6040 Fax 1628 Mail Service Center Raleigh, North Carolina 27699-1628 (919) 791-4200 788-7159 Fax 43 Washington Square Washington, North Carolin. (252) 946-6481 (252) 975-3716 Fax COUNTIES SERVED Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey Anson, Bladen, Cumberland, Harnett, Hoke, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland Alexander, Cabarrus, Catawba, Cleveland Gaston, Iredell. Lincoln, Mecklenburg, Rowan, Stanly, Union Chatham, Durham, Edgecombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson aufort, Bertie, Camden, Chowan. Craven, 27889 Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 350-2004 Fax 585 Waughtown Street Winston-Salem, North Carolina 27107 (336) 771-5000 (336) 771-4630 Fax Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pender Alamance, Alleghany, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin For more information, please visit our web site at: http://www.nccql.n EnqineerinceSe r31020Perm ts.html or contact the Regional Office serving your county. 7 KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) Owner/Perrnittee: 1a. Lincoln County, North Carolina Full Legal Name (company, municipality, HOA, utility, etc.) • lb, Bums Whittaker, P.E. - Director of Public Works Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) fo uthorized signing officials!) 1 c. The legal entity who will own this system is: 0 Individual ❑ Federal ❑ Municipality ® State/County ❑ Private Partnership ❑ Corporatio O 1d. 115 West Main Street LL Mailing Address 1 f, North Carolina Z State • 1 h. (704) 736 - 8497 Telephone Facsimile 2. Project (Facility) Information: J 2a. Airlie Industrial Park LL Brief Project Name (permit will refer to this name) Contact Person: Q 3a. David Richmond, PE Name and Affiliation of Someone Who Can Answer Questions About this Application 3b, (828) 328 - 2024 3c, da've.richmondcmcgjijengineers.com Phone Number E-mail 1 e. Lincolnton City 1 g. 28092 Zip Code E- ail Other (specify): MOORE ?'NAL :OFFICE 2b. Lincoln County County Where Project is Located New ❑ Modification (of an existing permit) edification, Permit No.: 2. Owner is Public (skip to Item B(3)) 2a. If private, applicant will be: ❑ Private go to Item 2(a)) 2b. If sold, facilities owned by a (must choose one 0 Retaining Ownership (i.e. store, church, single office, etc.) or 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) 0 Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. Lincoln County, North Carolina Owner of Wastewater Treatment Facility (WWTF) Treating Was 4a. Middle Forney Creek WWTP Name of WWTF 5a. Lincoln County Owner of Downstream Sewer b. 24" Gravity Receiving Sewer Size ❑ Force Main Public Utility (Instruction C) ❑ Homeowner Assoc./Developer (Instruction D) ater From This Project 4b. NC0074012 The origin of this wastewater is (check all that apply): ❑ Residential Subdivision 0 Apartments/Condominiums ❑ Mobile Home Park © School ❑ Restaurant 0 Office WWTF Permit No. c. WQCS00149 Permit # of Downstream Sewer (Instruction E O Retail (Stores, shopping centers) O Institution Hospital ❑ Church ❑ Nursing Home ❑ Other (specify): 100 % Domestic/Commercial % Industrial (attach description) (RO: contact your Regional Office Pretreatment staff) % Other (specify): 7. Volume of wastewater to be allocated or permitted for this particular project: '72,000 gallons per day *Do not include future flows or previously permitted allocations 8. If the permitted flow is zero, indicate why: ❑ Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA l 2/l17 B. PERMIT INFORMATION (CONTINUED) 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Itern B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item 13(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). 72 developable acres x 1,000 gpd = 72,000 gpd = 0.072 MGD 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) New Gravity or Additional Force Main 8 in. 3,880 Gravity 4 in. 870 Force Main 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID PS 1 (self chosen - as. shown on plans/map for reference) 7.— Design Flow (MGD) Operational Point GPM @TDH .................. .......-.__ - Power Reliability Option 1 - permanent generator w/ATS; ; 2 - portable generatorw/MTS Force Main Size Force Main Length 0.072 150 gpm @ 58' 1 4 in. 870 Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w/ATS; 2 - portable generator wIMTS Force Main Size Force a Main Length Pump Station Location ID (self chosen - as shown on planslmap for reference) Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option i f 1 - permanent generator w1ATS; ' Force Main Size 2 - portable generator wIMTS Force Main Length 1 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ['Yes ® No If Yes, permit number of 2nd treatment facility N/A (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ►_ Yes ■ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTAI2/07 04-07-' 11 11:'Ly MUM-L1N UU PUI]11C worKS roq-idp-64 1-101 ri ue3reurio r-Yua 04. Have the following permitsicertificalions been submitted for approval for the system or project to be served? 71/4 Si B 9 'n Official Si n1 e— D to 9 _ • (ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS 'APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY( in TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 WetlandiStream Crossings - General Permit or 401 Certification? I❑ Yes ❑ No ® N/A Sedimentation and Erosion Control Plan? ® Yes ❑ No 0 N/A Stormwaler? ['Yes ❑ No ® NIA 115. Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered hi* ot)rords and must he checked eingtevery six month ;Cheat if Yes: ❑ and provide details Owner/Permittee's Certificalion: (Signature of Signing Official and Project Name) • 1, Bums 14 hittaker P.E. Qirectorp(P}rblic Works , attest That this application for Lincoln County. North Cemline has been reviewed by me and is accurate and complete fo the best of my knowledge. 1 understand that it ell required parts of this application are not completed and that if all required supporting documentation and attachments ere not included, this application package is subject to being retumed as incomplete, Nola: ►n accordance with North Carolina General Statutes 142-215.6A end 143.2156H, any person who knowinglymakes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include aline not to exceed $ 10,000 as well 8scivippnelties U to 325,000 par violation. l a. z O. p. 0. iL i • 45 Professional Engineer's Certification: (Signature of Design Engineer and Project Name) Qftvid Richmond. P.E. attest that this application for Uric n County. North Carolina has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge.- 1 further attest that to the best of my knowledge the proposed design has been prepared in accorda-neil with the licable ►egu►ations, 'Gravity Sewer Minimum Design Criteria for Gravity Sewers - adopted February-1 2. f 998, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package. inclusion of these materials under my signature and seal signifies that ► have reviewed this material and have judged it to be consistent with the proposed design. Note; in accordance with NC General Statutes 143-215.6A and f43-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 as well as civil penalties up to S25.000 per violation. • 2a. David Richmond, P.E. •Professional Engineer Name 2b. McGill Associates,, P:A. 'Engineering Firm W- -- _- :: 2c. 1240 19 Street, Lane NW;.._ __ W .-_ �_ _. ..r--r-...... - • - Madmg Address 2d. HickNC 2 ory 2e. f. 28603 City I State . ! zip .,cN..RO� 11 : •-& • . ; 4 SEAL 9- 37 033635 = -., es • (828) 328.2024 th, (828).328 - 3870 i. David.Richmondf mcrgiitengineers.com i '' ► ��� i-IG• 11 Telephone - - - • - Facsimile - - -- -j- _E-mail - . - - - I NC P6 Seel Signature &Dale FTA12l07 Lowesvilie, NC NE/4 Gastonia 15' Quadrangle N3522.5 - W8100 / 7.5 04-01-" 11 11 Ly t t UM-LIN l.0 r'up11G worxs r 04- r ou-o-10� • 4 W A T-,�, State of North Carolina O• pG Department of Environment and Natural Resources a11. -mac Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE —10/07) Division of Water Quality Project Applicant Name: _Lincoln County Project Name for which flow is being requested: Airlie Industrial Park More than one FTSE 10/07 may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Middle Form Creek WWTP b. WWTP Facility Permit#: _ NC0074012 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow 0300 f. Total flow for this specific request 0.072 g. Total actual and obligated flows to the facility O. 317 h. Percent of permitted flow used 3070 All flows are in MGD 0.975 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity, MGD Approx. Current Avg. (Firm/Design) Daily Flow, MGD III. Certification Statement; 1, Burns Whittaker, P.E. — Public Works Director, certify that, to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacityrelated sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II for which I am the responsible party. Signature of this form indic accepts , e r - is a w w. % // Date tgning 0 tgnature FORM' WSCAS-12/07 WATERSHED CLASSIFICATION ATTACHMENT FOR SEWER SYSTEMS Applicant Name Project Name Lincoln County Airlie Indus Professional Engineer Name Engineering Firm Name David Richmond, PE McGill Associates, P.A. ©cation ID 1 2 Name of Waterbod UT to Forney Creek Coun incoln y River Basin Catawba UT to Forney Creek. nco Catawba UT to Forney Creek incoln Catawba aterbody Stream Index No. 119-2-3 Waterbody Classification 9-2- 9-2-3 1 If unnamed, indicate "unnamed tributary to X"°, where X is the named waterbody to which the unnamed tributaryjoins. I certify that as a Registered Professional Engineer in the State of North Carolina that I have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief. PE Seal, Signature and Date *** END OF FORM WSCAS-12/07 *** FORM: WSCAS-12/07 Page I of 1 LawesviUie, NC NE/4 Gastonia 15' Quadrangle N3522.5 - W8100 / 7.5 Permit Number WQ0035325 Central Files: APS_ SWP 05/05/11 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Fast Track Version Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Extensions Primary Reviewer dee.browder Coastal SW Rule Permitted Flow 72000 Facility Permit Classification Individual Permit Contact Affiliation Facility Name Major/Minor Region Airlie Industrial Park Minor Mooresville Location Address County Lincoln Owner Facility Contact Affiliation Owner Name Owner Type Lincoln County Government - County Owner Affiliation Barry McKinnon Director interim Public Works 115WMain St Lincolnton NC 28092 Dates/Events Orig Issue 05/06/11 App Received 04/12/11 Draft Initiated Scheduled Issuance Public Notice Issue Effective Expiration 05/06/11 05/06/11 Regulated Activities Re uested/Received Events Wastewater collection Additional information requested Additional information received Outfall NULL 04/27/11 04/27/11 Waterbody Name Stream Index Number Current Class Subbasin eGill SSOCI A 1" E S April 7, 2011 Mr. Rob Krebs Surface Water Protection Supervisor North Carolina Division of \Vater Quality 610 E. Center Avenue Mooresville, North Carolina 281 - RE: Fast Track Permit Application Airlie Industrial Park Lincoln County, North Carolina .Dear Mr. Krebs: Please find enclosed for your review and approval one (1) original and one (1.) copy of the Fast -Track Application for the Gravity Sewers, Pump Stations, and Force Mains, one (1) color copy of a quad sheet, a one (1) Watershed Classification form for the above referenced project. Please also find enclosed a check in the amount of $480 to cover the application fee. The project includes the installation of approximately 3,880 linear 'feet of 8-inch diameter gravity sewers, one (1) wastewater pumping stations, and 870 Linear of 4-inch diameter three main to serve the Proposed Airlie Industrial. Park, 'Die design of the project has been prepared in. accordance with NCDWO's minimum design criteria for gravity sewer lines. If you have any questions during your review or require further information regarding this project, please do not hesitate to contact us at (828) 328-2024. Sincerely', McGILE ES I)AVID 1—RICHMOND Senior Project Manager DER Enclosures Cc: Burns Whittaker, Lincoln County F:11 0.01415 Taiga Phase\CorrcspondenceANCDE N R-Fasi Jrack4-072011doc Engin eer g • Planning • Finance .4,;-sbb,bbc P Rox Lit5, Hi4.4ory 24,9 Mb Sr. i„ane r,c 2 n 011icc S28- 3 21)2'4 • bb4v.: bb 2r., 3S 70