HomeMy WebLinkAboutWQ0011095_Regional Office Historical File Pre 2018 (3)Water Resources ENVIRONMENTAL QUALITY March 31, 2017 Mr. Don Chamblee, Public Works Director East Lincoln Sewer District 115 West Main Street Lincolnton, NC 28092 Lr--- kOY COOPER IGovernor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director Subject: Permit No. WQ0011095 MODIFICATION East Lincoln Sewer District . Contract #5, Pump Station #11 Wastewater Collection System Extension Permit Lincoln County Dear Mr. Chamblee: In accordance with your application received March 28, 2017, we are forwarding herewith Permit No. WQ0011095 MODIFICATION dated March 31, 2017, to East Lincoln Sewer District (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, shall void Permit No. WQ0011095 issued October 10, 2016, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. This modification is for pump station modification due to additional flow from Rock Creek Subdivision. This upgrade to the pump station will increase the flow rate capacity of the pump from 345 GPM to 400 GPM. No additional flow will be added. Please pay particular attention to the following conditions contained within this permit: Condition I1.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be the responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. State of North Carolina 1 Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Officel 610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115 704 663 1699 if any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Ori Tuvia at (704) 235-2190 or via e-mail at ori.tuvia@ncdenr.gov. Sincerely, by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ cc: Jonathan Carter, P.E. (e-copy) Regional Office Files Water Resources Central Files PERCS (e-copy) Page 2 of 8 Envlronmen tal Quality WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to East Lincoln Sewer District Lincoln County for the construction and operation of a 400 GPM pump station with duplex pumps and high water alarms, as part of the Contract #5, Pump Station #11 upgrade project, and no new additional discharge of collected wastewater (previously permitted 133,056 GPD of domestic wastewater) into the East Lincoln Sewer District existing sewerage system, pursuant to the application received March 28, 2017, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. Permit No. WQ0011095 was originally issued on July 18,1995 for 7,965 linear feet of 8-inch gravity sewer, a peruse sewer collection system consisting of a maximum of 854 grinder pump stations each with 40 GPM (Maximum) simplex pump and high water alarm; approximately 1,187 linear feet of 2-inch pressure sewer, approximately 13,103 linear feet of 2.5-ich pressure sewer, approximately 4,032 linear feet of 3- inch pressure sewer and approximately 3,111 linear feet of 4-inch pressure sewer; a 210 GPM pump station with duplex pumps, telemetry system, portable generator hookup, high water alarms and approximately 11,475 linear feet of 6-inch force main; a 300 GPM pump station with duplex pumps, telemetry system, portable generator hookup, high water alarms and approximately 3,960 linear feet of 6-inch force main; the entire system shall serve approximately 657 connections in contract 5 for the East Lincoln County Water and Sewer District, with the discharge of 133,056 GPD of collected municipal wastewater into the county of Lincoln's existing sewage system. Additionally, on October 10, 2016 the Permit was modified to increase the existing pump station number 11 into 345 GPM. This Modification will upgrade the existing pump station number 11 into 400 GPM. No new flow is added. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. by W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ Permit Number: Permit Issued: WQ0011095 MODIFICATION March 31, 2017 Page 3 of 8 SUPPLEMENT TO PERMIT COVER SHEET East Lincoln Sewer District is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension, The sewage and wastewater collected by this system shall be treated in the East Lincoln Sewer District's Killian Creek Wastewater Treatment Plant in accordance with Permit Number NCO088722. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15ANCAC2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 13, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting ofPump Stations and Force Mains adopted June 1, 2O8O,aoapplicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. it shall be the Pernoittee's responsibility toensure that the as -constructed project meets the appropriate design crVte,ria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below, |. SPECIAL CONDITIONS 1 No flow in excess of the quantity permitted herein, 8 additional GPD dlaU be made tributary tothe subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division. [15A NCAC 02T,030:4(b)] Z. Pump station shall beclearly and conspicuously pustedusim#awe sign with opump station identifying name/number, 24-Hour Emergency telephone number, and name of the owner/operator of the sewer system/pump station and instructions to call the number in the event of alarm activation or other emergency. NLSTAYNDARD CONDITIONS 1. This permit |snot transferable. |nthe event there isodesire for the wastewater collection facilities to change ownership, or there is a name change of the Pennittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriete. The approval of this request shall be considered on its merits and may ormay not beapproved. Jl54NCA[O2T.010/kG.SI43'I15.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 154 NCAC 3T; the Division's Gravity SeworK8knhnum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.01101 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data, [15AWCACO2T.O11Q] Page 4 of 8 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: 115A NCAC 02T .0108(b)]: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. I. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (1) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. Page 5 of 8 . The Permitteeshall report by telephone to a water resources staff member at the Mooresville Regional Office, telephone number 3-l699,assoon aopossible, but innocase more than 24, following the occurrence or , knowledge a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage orbreakage, etc.;or b' Any SS[Jand/or spill over l,O8Ogallons; ur c. Any SSOand/or spill, regardless ofvolume, that reaches surface water Voice mail messages or faxed information is permissible, but thisshall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number(8OQ) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part | of Form CS-SSO (or the most current Division approved form) within five day; following first knowledge qfthe occurrence. This report must outline the actions taken nrproposed Tqbetaken to ensure that the problem does not recur. Part ||ofForm CS-SSC)(or the most current Division approved form) can also becompleted tnshow that the SSOwas beyond control. [G.S'243-Z15.1[(a1)] 6. Construction of the gravity sewers, pump stations, and force nnabg shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater tothe surface waters ofthe State. [1SANCACO2T.O108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities,the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents tothe address provided onthe form. Acomplete certification isone where the form io fully executed and the sopport)ngdecunmentsare provided asapplicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. if the permit isissued tpaprivate entity with amOperational Agreement, then acopy mfthe Articles mfincorporation, 0m«Jaratiunw/Cowenents/Restr|ct|on$,and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. Acomp|ete certification is one where the form in fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy ofthe project construction record drawings (plan & profile views of sewer lines & force maims) of the wastewater collection system extension. Final record drawings should be dear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc, b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, a,bihty to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If portable power source or pump is dedicated tomultiple stations, an evaluation ofall the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timefrannes,shall beprovided. Page 6 of 8 c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimiurr—Design Criteria should be clearly identified on the record drauvirigs; on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000, as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. (15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be _ required by the Division or any other Federal, State, of Local government agencies. [G.S. 143- 215.1(b)] Page 7 of 8 FAST TRACK SEWER ENGINEERING CERTIFICATION -East Lincoln Sewer District VVQ0811095N1OD|F|CAT|QN Contract #S,Pump Station #11 March 31,2017 This project shaDnutbeconsideredcomp|eteno,aKmwedtoqpenateinaccordanoowithCondition7of this permit until the Division has received this Certification and all required supporting documentation. It should besubmitted inamanner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Pennitteetn appropriate enforcement actions. The Perrni1tee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'GCERTIqCATON |,the undersigned agent for the Pennittee, hereby state that this project has been constructed pursuant tothe applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEER"S CERTIFICATION |, ,asaduly registered Professional ErintheStatcofNmrth[oro|ina, having been authorized to observe (F� periodically, [—| weekly, �l full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A N[ACUIT; the Division of Water Resources' (Division) Gravity Sevve, Minimum Design Criteria adopted February II' 1996,asapplicable; the Division's Minimum Design Criteria for the Fast -Track Permitting ofPump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting, materials. North Carolina Professional Engineer's Seal vv/signature&date: 0 Final F_� Partial (include description) Certification Comme|ifiers (attach if : State ^xNorth caroLinu|s"=onmemta;o"ai�y|Water x°source^|Water Quality scloona/ovm="ms Mooresville Regional omc am'Fastc^merxm^ "e,uuit°m1|Moon*"ue,worthcw*xnazol 15 State of North Carolina Department of Environmental. Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION I7lvlslons of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: Qcmnp et d by DWR) All items roust be completed or the applieatiott will be returned APPLICANT INFORMATION: 1. Applicant's name: East Lincoln, ?. Applicant type: 0 individual 0 Corporation 0 Federal © State/County Signature authority's name: Don Chamblee per 1tir1„_ Title: Public Works Director 4. Applicant's mailing address: 115 V. Main Street. City: Lincolnton State: NC Zip: 28097-_T Applicant's contact information: Phone number: (704) 736-8497 Email Address: dchamb.lee@lincolncaunty.org PROJECT INFORMATION: 1. Project name: Contract #5,x P 2. Application/Project status: District (company. municipality, HOA, utility, etc.) 0 General Partnership 0 Privately -Owned Public `litility tiara # 11 Upgrade 0 Proposed (New Pet Municipal .j 0 1..„01 tJ(x(11µ? Existing Perrnit/Project If a modification, provide the existing permit number: WQ001,1095 and issued date: J Iy 18> 1995 If new construction but part of a master plan, provide the existing permit number: WQOO 3. County where project i Iocated: Lincoln 4, Approximate Coordinates (Decimal Degrees): Latitude: 35 2)1 9' Longitude-81,020191 5. Parcel ID(if applicable): 71176 (or Parcel ID to closest downstream sewer) 1:11. CONSULTANT INFORMATION: 1. Professional Engineer: Jonathan A. Carter License Number: 30916 Firm: Bluestone Land. Management PLLC Mailing address: 115 Autumn Frost Avenue City: Statesville State: NC Zip: 28677- Phone number: (704) 649-2863 Email Address: ion athan,carter(a7bluestonelandmnanagement.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I, Facility Name: Killian Creek WWTP Permit Number: NC0088722 Owner Nance: East Lincoln Sewer District V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Nurnber(s): WQ __ Downstream (Receiving) Sewer Size: 12 inch System Wide Collection System Permit Number(s) (if applicable): WQCS00149 Owner Name(s): East Lincoln Sewer District been attached? hed? 0 Car Wash 0 Hotel and/or Motels 0 Swimming Pool /Clubhouse © Swimming Pool/Filter Backwash. 0 Other (Explain in Attachment) Yes No GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? 0 Yes ONO N/A 2. If the Applicant is a Developer of Lots to be sold, has a Do... 0 Yes ©No N/A lithe Applican 4. Origin of wastewater: (check all that apply): Residential Owned 0 Residential Leased 0 School / preschool / day care 0 Food and drink facilities 0 Businesses / offices / factories 5. Nat © Retail (stores, centers, malls) © Retail with food preparation/service 0 Medical / dental / veterinary facilities 0 Church 0 Nursing Home e of wastewater : 1 QQ % Domestic/Com:mercial % Commercial % Industrial (See c—ls there a Pretreatment Program in effect? b. Has a flow reduction been approved under l 5 A N (2� AC (I)? Yes )0 iIf ves, provide a copy of flow reduction approval letter 7, Summarize wastewater generated by project: ablishment Typ a See o NC:AC 02T ,01 14(b); ciiLcJk) and ,,e)QJ for caveats to wastewater design flow rates (i.e., tninimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in (IS,4 'h-)• b Per I.5A NCAC 02T .0114((), design flow rates for establishments not identified [in table 1 < \t () i l l l] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: Q GPD (per Do not include future flows or previously permitted allocation If permitted flow is zero, indicate why: Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit Number © Rehabilitation or replacement of existing sewer with no new flow expected Other (Explain): Pump station modification due to additional flow from Rock Creek Subdivision (130 pts) GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 1. Summarize gravity sewer to be permitted: Size (inch Length (feet) Material r Section II & 11I of the MDC for Permitting of Gravity 'Sewers contains information t related to design criteria Section 1.11: contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA Of Applicable) — 02T ,03,05 & M O!C.Arup COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Contract #5, Pump Station # 1 1 2. Approximate Coordinates (Decimal Degrees): Latitude: 35.521139' Longitude:-g1.0201914' 3. Design flow of the pump station: 0.5760 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 400 gallons per minute at ?'26 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): ches) Length (feet) Material Power reliability in accordance with Standby power source or pump with automatic ar vation and telemetry - 15A :NCAC 02T .0305(hX 1)(R): S> Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day r- Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: El Portable power source with manual activation, quick -connection receptacle and telemetry .0305(h)(1)(C) or 5A NCAC 02T Q Portable pumping unit with plugged emergency pump connection and telemetry - I5A NCAC 02T .0305(It)(IC): S' It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. • If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case ofa multiple station power outage. SETBACKS & SEPARATIONS - (028 .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15,Nt � t� 1` .(1 t1 'll & ( ) • 15A NCAC 02TA305(f) contains minimum separations that shall be provided for ewerstems: Storm sewers and other u Water mains (vertical - water over' sewer including in benched trenches) _-_ Water mains (horizontal) Reclaimed water lines (vertical reclaimed over sewer) Setback Parameter* isted below (vertical) Reclaimed water lines (horizontal - reclaimed over sewer) Yes D No Separation Required **Any private or public water supply source, including any wells, WS-I waters of Class I or Class Il impounded reservoirs used as a source of drinking water **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HOW, or SB from normal _high water or tide elevation) and wetlands see item IX.2) **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches. Any building foundation Any basement Top slope of embankment or cuts of 2 feet or more vertical. height Drainage systems and interceptor drains Any swimming pools Final earth grade (vertical) • \{',AC 02'F 0 r0512contains alternatives where separations in 0 A * Stream classifications can be identified using the Division's situ° ➢ If non compliance with (M' (C _11) or 1 pep, see Section X of this application 24 inches inches 10 feet inche 2 feet 100 feel 50 feet e 10 feet 0 feet 5 feet 10 feet 36 inches achieved. Tk,toils, r:OP!,? Does the project comply with separation requirements for wetlands? (50 feet of separation) A See the Division's draft separation requirements for situations where separation cannot be meet A No variance is required if the alternative design criteria specified is utilized in design and construction A As built documents should reference the location of areas effected Does the project comply with all setbacks found in the river basin rules per 1 , ' NO(` A This would include Trout Buffered Streams per I s ,NUAC 1 12,02 Does the project comply with an individual 404 Permit or any 401 Certifications? No No No • Wetland -related permits shall be requested obtained, and adhered to for projects that impact wetlands or surface wat ➢ Information can be obtained from the <1101 ,KL.3uu1ter Perm 1ttik Does project comply with i ; '.r t ( 1(i�la'.)(0) (additional permitslcertthcations)? Yes ] No Per dh \ v ri (_o' u 10 1_0j, directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are: deemed "high -priority?" Per ri 15A Aall02T (s4U2, high -prior syseer" means erosion ty aerial sewer, sewer contacting surface waters, siphon, or sewer P pav subjectthat undermines or deteriorates the sewer. D Yes ® No A if yes, include an attachment with details for each line, including type (aerie line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at Least once every six -months and insp, etions documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. CERTIFICATiONS: 1, Does the submitted system comply w tni_&ct�c\lain LEar,est,,cision,andtheCis' of P iiip applicable? ` tati ® Yes No If No, complete and submit. the VariancelAlternative Design Request application (V.ADC 10-14) and supporting documents for review. Approval of the requcst is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: (Professional Engineer's name :from Application lte attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the hest of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE In accordance with General Statutes I43-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed '$10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: Applicant's Certification per 15A NCAC 02T .0106(b);. (Signature Authority's name title from Application item 1. has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included_ this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution, 1 will make no claim against the Division of Water Resources should a condition of this permit he violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. arse application for NOTE In accordance with General Statutes i 43 ? I ,i> and 1 , ? 1 .6 t1, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. COUNTY OF LINCOLN, NORTH CAROLINA 1 1 5 WEST MAIN STREET, 21\° FLOOR CITIZENS CENTER, LINCOLNTON, NORTH CAROLINA 28092 DEPARTMENT OF PUBLIC WORKS PHONE (704) 736-8497 FAX (704) 736--8499 WWW,LINCOLNCOUNT ,ORG September 19, 2016 NCDEQ/DWR Water Quality Permitting Peres Unit 512 N. Salisbury Street, Suite 925 Raleigh, NC 27604 RE: ELSD — Upgrade to Co Dear Sir or Madam, #5 (WQ001091.8) Pump ns#1 and#11. This letter is provided for flow acceptance of the wastewater treatment infrastructure (the "System") for the Rock Creek — Phase I and Phase II Development (the "Project"). Lincoln County (the "County") has the actual average daily flow capacity at its Killian Creek. Wastewater Treatment Plant to treat the domestic wastewater as requested, and does conditionally grant approval for the Project, subject, however, to the terms and conditions below: 1.. The amount of flow requested for Phase I of the Project is for 57 lots with a total flow of 13,680 gallons per day of additional flow at the NCDENR approved reduced flow rate of 240 gallons per day per home into LS-01 and. LS-1 1; and The amount of flow requested for Phase 11 of the Project is for 73 lots with a total flow of l 7,520 gallons per day of additional flow at the NCDENR. approved reduced flow rate of 240 gallons per day per home into LS-01 and LS-11; and The total amount of flow requested for Phase I and Phase II of the Project is for. 130 lots w a total flow of 31,200 gallons per day of additional flow at the NCDEQ approved reduced Mow rate of 240 gallons per day per home into LS-01 and LS-1 1; and 4. 1t is Lincoln County understanding that Pump Stations #1 and 41.1 (WQ0410918) are to be upgraded to accommodate the Clow from Phase I and Phase II of the Rock Creek Development. At this time only Phase 1 (57 lots) of the Rock Creek Development is being permitted by NCDEQ and constructed. Phase 11 (73 lots) will be seeking submittal and approval of a permit by Lincoln County and NCDEQ at a later date; and 5. For the NCDEQ Permits, the receiving sewer treatment facility is the Killian Creek WWTP, Permit #NC 0088722. The sewer collections facility is the East Lincoln County Water and Sewer District, Permit #WQCS 00149; and 6. The County shall be named as the Permittee on NCDEQ system applications; and. 7. Final acceptance of the System to the County is subject to the following: a. A complete final inspection and approval of the System by the County, and receipt of other applicable documentation requested by the County; and b. Approval of the System by NCDEQ, and proof provided to the County of a valid permit issued by NCDEQ with an Authorization to Construct (ATC); and c. Initiating construction of the Project within two years of the date of this conditional approval. The Rock Creek Development must notify the Lincoln County Public Works Department in writing when construction of the Project is initiated; and d. The County continuing to have actual average daily flow capacity to treat the domestic wastewater as requested at the time all other conditions precedent have been satisfied. e. That upgrades and improvements to sewer pump station #01 and sewer pump station # 11 are complete and fully operational as designed to accommodate the Rock Creek Phase I and Phase II Development sewer flow prior to any approval, acceptance of any phase of the Rock Creek Development, and transferal of the Rock Creek Development to the County. This acceptance and allocation of flow shall only be effective upon compliance with all of the above terms and conditions and the County providing an acknowledgment that has complied with all of the above terms and conditions. Included in this mailing is the Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE — 04/16) with the County's portion completed. If you have any questions, please do not hesitate to call me at 704-736-8497. Sincerely, 0 ,,Q u,,LC.9-1,--- Chris Henderson Engineering Associate Cc: File SUUFCI;t aK: 9t 91330 T19 Jan 29 2007 14:10 P.02 Michael F. Easley, Governor hr�+sam a Ross Jr„ 3iatlary nment and Natural Reso<vdr Alan W. Kir d , RE., C?ii x Division at Water Duality A. Gilbert, P. E, Direct ty Public Utilities Street Nch Carona 28092 Dear Mr. Gilbert: January 29, 2007 Subject: Lincoln County - Middle Forney Creek WWTP Residential Flow Reduction Approval Lincoln County 2S, 2006, tt Divi ten of Water Quality moved a flow reduction request for residences in. Lincoln oimty sewed by the Middle Forney Creek WWTP Pen rt No. NC0074012). The letter requests an allowable flow rate of J60 GPD per residential connection based on the evaluated data from tile WWTP and the active number of residential connections. The DMR dos provided between. January 1996 and. December 2006 with daily readings taken doting November 20O6 and December 2O06 was analyzed by central office and regional of ce staff with additional information requested. Based upon this data and the County response to our additional information requests, the Division hereby approves the use of GPI) per residential bedroom, with a minimum of 160 gpd for one and two ballroom units in all applicable noon-discbatge permit applications. Flow shall be incremented by 80/gpd far each bedroom above two. a ad" wastewater flow rate, at no lase fatty Avs� ;Acted t)ae comity of the sewers d,wnstream_of any new sewer extengen or service cor mect,ion(s)..A peanut modification and fee is required to apply this flaw reduction to any existing permits where flows have been allocated_ If you have any questions or comments regarding this matter, please contact Bennie Goetze, Jr., P.1 E. at (919)733-5083 eV_ 375. Ms. Dee Browder, Mooresville Regions Ms. Susan. Wilson, NPDES West Ptograrn PERCS Flow Reduction File Prefix tnient Emergency Response and Colection Systems Urtet Internet httpJRi20.enr ncstate,tisindpu a 1617 mail ;terms Caner, Riatetgh, NC 27690.1617 ► n Equal Oopodurity Aden Employer. 'telephone (919) 733- O63 Fax (919) 733- 059 50%, recydeelr1 O% loot- .ram PaPef FILE COPY State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: East Lincoln Sewer District Project Name for which flow is being requested: Upgrade to Contract #5(WQ0010918) More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Killian Creek WWTP b. WWTP Facility Permit #: NC0084573 All flows are in MGD c. WWTP facility's permitted flow 3.35 d. Estimated obligated flow not yet tributary to the WWTP 0.853 e. WWTP facility's actual avg. flow 1.058 f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 0.018 1.911 57.0% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow; List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / p f), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** #37 4.17 1.67 1.484 0.853 2.337 -0.667 #15 2.52 1.008 1.317 0.645 1.962 -0.954 #12 2.62 1.05 0.288 0.211 0.499 0.551 #11 0.412 0.166 0.118 0.102 0.220 -0.054 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < O. Downstream Facility Name (Sewer): East Lincoln Water and Sewer District Downstream Permit Number: WQCS00149 Page 1 of®7 FTSE 04-16 • State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: East Lincoln Sewer District Project Name for which flow is being requested: Upgrade to Contract #5 (WQ0010918) More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Killian Creek WWTP b. WWTP Facility Permit #: NC0084573 All flows are in MGD c. WWTP facility's permitted flow 3.35 d. Estimated obligated flow not yet tributary to the WWTP 0.853 e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 1.058 0.018 1.911 57.0% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity, * (Firm / pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** #1 0.115 0.046 0.057 0.035 0.092 -0.046 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < O. Downstream Facility Name (Sewer): East Lincoln Water and Sewer District Downstream Permit Number: WQCS00149 Page i-af6 Z m7 FTSE 04-16 III. Certification Statement: I Donald V. Chamblee, Jr. certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. r \- x , u N IA (26 4, Signing Official Signature Date Page 2ef 6- 3e.F7 FTSE 04-16 PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section II where Available Capacity is < 0. Pump Station (Name or Number): S7 Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for 36.4 % and 0.853 MGD of the Available Capacity (E) in Pump Station #37 ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0.060 MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely Killian Creek Pumpstation Upgrade is in design or under construction with planned completion in 2016 ; and/or d. The following applies: The County is currently near completion of construction on the Killian Creek Upgrade This will more than double the capacity at Station #37. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity. in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. V 62,-, qtri f/v6 Signing Official Signature Date Page3-of6r Yaf'7 FTSE 04-16 PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section 11 where Available Capacity is < 0. Pump Station (Name or Number is Given that: a. The proportion and a_mount of Obligated, Not Yet Tributary Daily Flow (C) accounts for 32.8 % and 0.645 MGD of the Available Capacity (E) in Pump Station #15 ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0.060 MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely Lowesville Sewer Project is in design or under construction with .planned completion in FY 2017 ; and/or d. The following applies: The Lowesville Sewer Project has been awarded. Construction time for this project is approximately one year. The Project will double capacity at Station #15. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. v G,Th (2).( Signing Official Signature Date Page 3-ef6 FTSE 04-16 PLANNING ASSESSMENT ADDENDUM (PAA) Submit a planning assessment addendum for each pump station listed in Section II where Available Capacity is < 0. Pump Station (Name or Number): i [ Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for 46.3 % and 0.102 MGD of the Available Capacity (E) in Pump Station # 11 ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0.060 MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely Upgrade to Contract #5 (WQ0010918) is in design or under construction with planned completion in FY 2017 ; and/or d. The following applies: The Project Upgrade to Contract #5 has been engineered and is submitted as this project. It consist of upsizing of pumps, controls, and generator back up at both stations #1 and #I 1. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant Iikelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. v .JCS--_ Signing Official Signature 1(1? (24)1(c) Date Page 9rorf& 6 ac--.7 FTSE 04-16 ritapianning assessment addendum for each pump station Iisted in Section II where Available Capacity is < 0. PLANNING ASSESSMENT ADDENDUM (PAA) Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for 38.0 % and 0.035 MGD of the Available Capacity (E) in Pump Station #1 ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0.060 MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely Upgrade to Contract #5 (WQ0010918) is in design or under construction with planned completion in FY 2017 ; and/or d. The following applies: The Project Upgrade to Contract #5 has been engineered and is submitted as this project. It consist of upsizing of pumps, controls, and generator back up at both stations #1 and #11. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. \f, etirt (2,(p Signing Officia gnature Date Page-3flf6 7 c FTSE 04-16 BT .LTESTONE LAND MANAGEMENT, PLLC 237 DRY DOCK LOOP MOORESVILLE, NC 28117 (704)649-2863. biuestonela.ndmanagementt<com NC License x: P-1.444 PUMP STATION #1 AND #11 LINCOLN COUNTY, NORTH CAROLINA PROJECT #: 20t6-0OO4 DRAWN BY: JAC EAST LINCOLN' SE' R 6 I TRIO DATE: 08/17/16 'H ECKED BY: JAC TITLE USGS/STREET MAP SHEET iOF1 Bluestone Land Management, PLLC 470 N. Broad Street, Suite A Mailing Address: Mooresville, NC 28115 115 Autumn Frost Avenue (704) 649-2863 Statesville, NC 28677 March 24, 20r Mooresville Regional Office Water Quality Section 610 E. Center Avenue, #301 Mooresville, NC 28115 Project: East Lincoln Sewer Dis Project Location: Lincoln County, North Carolina Dear Sir or Madam, - Upgrade to Contract #5 - Pump Station #11 On behalf of the East Lincoln Sewer District, please find attached the following: 1. One original and one copy of the Sewer System Extension Applications (FTA-04-16) - Pump Station #ii 2. Cover letter 3. One Application fee of $480.00 payable to North Carolina Department of En ironzuental Quality (NCDEQ). 4. Flow tracking form (FTSE 04-16) 5. 8.5 x 11 - USGS topographic map 6. Street level map This project involves a modification to the previous approved modification dated October 10, 2016. The modification includes changing the 50-hp pumps to 6o-hp pumps. This modification will 'increase the flow rate capacity from 345 gpm to 40o gpm. No additional flow will be added.. Please contact me with any questions/comments. Jonathan A. Ca P.E. Central Files: APS SWP 3131/2017 Permit Number WQ0011095 Permit Tracking Slip Program Category Status Project Type Non -discharge Active Major modification Perrnit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer ori.tuvia Coastal SWRuie Permitted Flow 0 Facility Version Permit Classification 1.30 Individual Permit Contact Affiliation Richard L. French Citizens Center 115 W Main • Lincolnton NC 28092 Facility Name East Lincoln County Contract 5 Location Address Owner Major/Minor Region Minor Mooresville County Lincoln Facility Contact Affiliation Owner Name Lincoln County Dates/Events Owner Type Government - County Owner Affiliation Donald Chamblee Director Public Works of 115 W Main St Lincolnton NC 28092 Orig Issue 7/18/1995 Scheduled App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 3/28/2017 3/31/2017 3/31/2017 Regulated Activities Requested !Received Events Apartment complex Subdivision Wastewater collection Wastewater treatment and disposal Outfall Additional information requested Additional information received Waterbody Name Streamindex Number Current Class Subbasin