Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0035166_Regional Office Historical File Pre 2018 (2)
Mr. Robert Hites, City City of Statesville PO Box 1111 Statesville, NC 25687 Dear 'rv1 aver Corrected Copy January 6, 2011 Subject: Permit No. WQ0035166 Corrected I-381 9A `astewa.ter Collection System Extension lredell County,, North Carolina In accordance with your complete application received on Janr,ary 5, 2011, we are forwarding herewith Permit No. W000351 16, with the corrected permit t3un ,ber, dated January 6, 2011 for the construction and operation of the subject wastewater collection system extension, This permit shall be effective from the date of issuance until rescinded and shall he subject to the conditions and limitations as specified therein, This cover letter shall be considered a part of this permit and is Therefore incorporated therein by reference. Please pay particular attention to Pe,rrnit Conditions 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any par of the project that does not meet 1) 15A NCAC 2T: 2) the Division cf VJat>er Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable, 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and force Mains adopted June 1, 2000, as applicable,, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mao•ras.lire Reg nai Office Location: 610 East CenterAVe , Suite 301 Mooresville, NO 28115 Phone: (704) 66 a-1699 1 Fax: (704) 603 6040 1 Customer Servlcti. 1-377-623-6743 Internet: v 1MW„ilcvy ter u,a3 erg e with tt e provisions of Crapt 143 Gererai Statutes cf North Cares'ir,a as amended, and ether applicable Laws, Riles, and aRegulatcrs, permission is heresy granted for the construction and operation of approximately 42 linear feet cf 3=-inch gravity sewer; 88,0 linear feet of fl- inch gravity sewer, 477 linear feet of 10-inch gravity sewer, 820 linear feet of 30-inch gravity sewer, and the discharge of 0 gallons per day of domestic wastewater in conformity with 15A NCAO 2T, the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Divisions. Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit The sewage and wastewater collected by this system shall be 'seated in the City of Statesville WWP TP (NPDES Permit No. NC0031836) prior to being discharged into the receiving stream, Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of the City of Statesville. Statesville must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and the collection system permit WQCS0003O. If any parts, requirements, car ('imitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of Norh Carolina General Statutes, and filed with the Office cf Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714, Unless such demands are made, this permit shall be final and binding. if you need additional infomaticn concerning this matter, please contact Dee Browder at (704) 663-16699. Sincerely, Mooresville Regional Office, Collection System Perm%t f=i@ Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. This permit sha not be transferable, in the event there clE-,\Sire fcr the iivastei,vatier ccilecticin facilities to criange ownership, or there is .F.4. name change 3f tire Permittee. 2 formal permit request shall he submitted to tine Diivisich accompanied by dricurrentatich from :he !dames involved. anc, other supporting materials as may be appropriate,. 'Ile approval cif this request shad be considered on its rnerits arid .may or may not be accroved. Construction cf the chavity isetivers. pump stationsand force mains shall re scheduled so a riot to interrucf service by tne existing LifihtleS iler result in an yverfloti,,,v tycass disistinaritte of 'wastewater to the surface waters cf the State. Per 15A NCAC 2T .0116, upon complet orti of construction and prior to operation cf these permitted facilities the completed E.ndineerind Certification form attached to this permit shall be submitted' with the required supporting documents to the address pr0'.Ided on tine form A comotete certification is one where the form is fully executed and the supporting documents are provided as applicable. A iccifpy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 5 Failure to abide by the conditions and liMtations contained in this permit; 15.A NCAC 2T, the DiVISIOn's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable, the Division's Minimum Design Criteria for the Fast -Track Permitting of Punip Station and Force Mains adopted. June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with Nor,'ri Carolina General Statutes §143- 215,SA through §143-215.6C, 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions. the Permittee shall take immediate corrective action, including those as may be required by this Division suctil as the construction cif additional or replacement facilities. 10 The issuance of this permit shall not exempt the Permittee from complying with any and all statutes rules, regulations, or ordinances that may be imposed by other government agencies (local; state and federal) which have jurisdiction. including but not limited to applicable river buffer rules in 15A NCAC 28 .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's Genera! Permit NCG010000, and any requirements pertaining to 'Wetlands under 1,5A NCAC 2B 0200 and 15A NCAC 2H 0500. 11. Noncompliance Notification: The Peirrnittee shall verballyreport to a Division of Water Quality; employee at the Mooresville Regional Office, telephone number (704) 633-1699, as soon as possible but in no Case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the followingo : Any process unit -failure, dr e. to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; er b. Any failuro of a pumping station Cr sewer lire. resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone numcer (800) 858-0368 or (919) 733-3300_ Persons reporting any of the above occurrences shall He a spill report by completing Part i of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 6th day of January, 2011.; NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0035166 Permit No. WQ0035166 Janeary 6, 2011 Owrer,AJVQCS[v`MJTP Robert Hites. City Man.acer City of Statesville PC Box 1111 Statesville, NC 28687 PE Larry Mitchell AECOM Technical Services of NC: Inc. 701 Corporate Canter Drive: Suite 475 Raleigh, NC 27607 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit. regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of I-3819A, an Iredel! County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Pe due (3.-,cv'ern0r Mr. Robert Hites, City Manager City of Statesville PO Box 1111 Statesville, NC 87 Dear Mr, Hites, i t,t of E 'stcn of Director tuaiity January 6, ,Dee F eenian St cr ,t.ar°,, Subject: Per, No_ W000351 16 1-3319A Wastewater Collection System Extension Iredell County, North Carolina In accordance with your complete application received on January 5, 2011, we are forwarding herewith Permit No. WQ0035116 dated January 6, 2011 for the construction and cperation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a pare of this permit and is therefore incorporated therein by reference, Please pay particular attention to Per rnit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .9403 or any individual systern-wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein, Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina. General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, andlor referral of the North Carolina -licensed Professional Engineer to the licensing board. Moores), le Regional Office Location: 610 East Center Ave., Saute 301 M9ocresvil[e NO 23115 Fanner (704% 663-'1699 \ Fax (704) 563-6040 - Service: a'- 77-623-6743 Internet wwLV nr:walnrriirnli}t, nrn.. MT. ;Hiles Page 2 In accordance with the provisions of Article 21 cf Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations permission is hereby granted for the construction and operation of approximately 42 linear feet of 6-inch gravity sewer, 850 linear feet cf 3- inch gravity sewer, 477 linear feet of 10-inch gravity sewer, 520 linear feet of 30-inch gravity sewer, and the discharge of 0 gallons per day of domestic wastewater in conformity with 15A NCAC 2Ti the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, asapplicable, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part ofthis permit. The sewage and wastewater collected by this system shall be treated in the City of Statesville WWTP (NPDES Permit No. NC0031836) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of the City of Statesville. Statesville must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and the collection system permit WQCS00030.. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning thiser, please contact Dee Browder at (704) 663-1699. Sincerely, Coleen H Sullins cc: Mooresville Regional Office, Collection System Permit Files Surface Water Protection Central Files PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4, This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is 3 n am e change of the Permittee. a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting rhaterials as may be iappropriate. The approval of this request shall be considered on its merits and ma.y cr may not be approved, 5, Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow cr bypass d scharge of wastewater to the surface waters of the State. 6, Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the iform. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable, 7.. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities; 8.. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applica.ble; the Division's Minimum Design Criteria for the Fast -Track. Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215,6A through .§143-215.6C. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities; 10, The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch, 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 28 .0200 and 15A NCAC 2H .0.500, 11, Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a, Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; CI b, Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility, Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergence Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed tb ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show_ that the SSO was beyond control. Permit issued this the 6th day of January, 2011. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ00351.1.6 Permit No. WQ0035116 January 6, 2011 OwnerIWQCSMMITP Robert Hites, City Manager City of Statesville PO Box 1111 Statesville, NC 28687 PE Lam Mitchell AECOM Technical Services of NC, Inc. 701 Corporate Center Drive, Suite 476 Raleigh, NC 27607 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension . • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should beclearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of I-3819A, an Iredell County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) . OwnerlPermittee: of State sviiie — Full Legal Name (company, municipality, HOA, utility, etc,) b. Robert W. Hites Statesville C1 Maria ilatiatOkt,44;-' • Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized signing ±j-ittnn ) SIAM SECIION The legal entity, who will own this system is: 0 Individual 0 Federal Municipality El State/CountyEj Private Partnership 0 Corporation 0 Other ( d. PO Box 1111. 11e. Statesville Mailing Address NC City 1g. 27687-1111 State Zip Code h. 704-878-3584 Ili. 1j. robert_hites@ci.statesville.neus Telephone I Facsimile 1 E-mail Project (Facility) Information: --i I-3819A 2b. Iredell -- Brief Project Name (permit will refer to this name) County Where Project is Located Contact Person: a. Larry Mitchell, RE. Name and Affiliation of Someone Who Can Answer Questions About this Application b. 919-854-.6235, larn[mitchOl@aeconixorn Phone Number E-mail Project is New 0 Modification (of an existing permit) If Modification, Permit No.: wner is 4 Public (skip to Item B(3)) Private (go to Item 2(a)) . If private, applicant will be: 0 Retaining Ownership (i.e, store, church, single office, etc.) 0 Leasing units (lots, townhomes, etc, - skip to item BM) Selling units (lots, townhomes, etc, - go to Item ElPbb City of Statesville r 2b. If sold, facilities owned by a (must choose one) 0 Public Utility (Instruction C) 0 Homeowner AssociDeveloper (Instruction D) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project . Fourth Creek WWTP 4b. NC0031836 Name of WWTF WWTF Permit No: a. Statesville5b. 30" Owner of Downstream Sewer Receiving Sewer Size The origin of this wastewater s (check all that ap2tyl: Residential Subdivision 0 Apartments/Condominiums E1 Mobile Home Park CI School o Restaurant El Office Gravity 5c, Force Main j Permit # of Downstream Sew Retail (Stores, shopping centers) CI Institution E] Hospital 0 Church Nursing Home 0 Other (specify):, 100 % Domestic/Commercial % Industrial (attach description.) (RO: contact your Regional Office Pretreatment staff) % Other (specify): Volume of wastewater to be allocated or permitted for this particular project: 0 gallons per day 'Do not include future flows or previously permitted allocations If the permitted flow is zero, indicate why: 0 Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line o Flow has already been allocated in Permit No. Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FrAl 2/07 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). N/A — no additional flow. 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (in es) Length (feet) New Gravity or Additional Force Main t Gravity 6 42.00 Gravity 8 N. 849.81 y Gravity 10 477.07 Gravity 30 \ 520.64 Gravity 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w/ATS; 2 - portable generator wIMTS Force Main Size Force Main Length 0 Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow 0 (MGD) Operational Point GPM @TDH1 Power Reliability Option - permanent generator wIATS; 2 - portable generator w/MTS Force Main Size Force Main Length ` Pump Station Location ID (self chosen - as shown on planslmap for reference) ° Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w/ATS; 2 - portable generator w/MTS Force Main Size Force Main Length 12. ■ Will Yes the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ►Z4 No If Yes, permit number of 2°d treatment facility (RO — if "yes" to 8,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes ❑ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS ._1 I` PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA12/07 14.. Have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401Certification? ❑ Yes ❑ No ® N/A Sedimentation and Erosion Control Plan? ❑ Yes ❑ No ® N/A Stormwater? ❑ Yes ❑ No ® N/A 15. Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)1 involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: El and provide details 1. Owner/Permittee's Certification: (Signature of i, Robert W. Hites , attest Signing Official that this application best of my knowledge.) documentation Note: makes which and Project Name) for I-3819A has been reviewed any civil by me and is accurate and complete to the are not completed and that if all required supporting package is subject to being returned as incomplete. 215.6A and 143-215.6B, any person who knowingly application shall be guilty of a Class 2 misdemeanor, penalties up to $25,000 per violation. understand that if all required parts of this application and attachments are not included, this application In accordance with North Carolina General Statutes 143- any false statement, representation, or certification in may include a fine not to exceed $10, 000 as well as } la. f? 71 7 /1/ 7a J fb dal al Signdture Date , ' ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS 4 PPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY 0 OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 r. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, Larry W. Mitchell, P.E. , attest that this application for I-3819A has been reviewed other by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all supporting documentation to the best of my knowledge. l further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25 000 per violation. a. Larry W. Mitchell, P.E. i 11 ACP o r r,, ` C► 5� 'r,, 1,, d �A✓ 1: = SEAL �j' p 025 : (A, r� .,.�� � at.vVal ov �.. t"ti. VW e � NC PE Seal, Signature & Date Zo Professional Engineer Name e b. AECOM Technical Services of NC, Inc. _ Engineering Firm c. 701 Corporate Center Drive, Suite 475 Mailing Address _ d. Raleigh 2e. NC . ?f. 27607 City • State Zip :.. g. (919) 854-6235 eh. 919-854-6259 2i. iarry.mitchell@aecom.com Telephone Facsimile E-mail FTA 12/07 SCALE I:24,000 0 Z000 SOURCE: NCFJGT GfS USGS Topographic Maps I MILE 7000 FEET I KIILOME TER FIGURE 1 TOPO MAP H-3819A DELL COUNTY, NORTH CAROLINA FORM WSCAS-12/07 WATERSHED CLASSIFICATION ATTACHMENT FOR SEWER SYSTEMS 'ApplicantlName •c .. _ `'.: '?'._ `"nL 4PTojeot-'Name < `:-y 5i ` '" ''. . _ • City of Statesville, NC I-3819A Profe�sionallEngirieei Nalr a Y? ,L 4 J- :4-,f; E lEngiiieeringiFirm Names , . ,14 ,..;.. ,.‘75w. - Larry Mitchell, PE AECOM Location ID Name of Waterbody' County River Basin Waterbody Stream Index No. Waterbody Classification 1 Fourth Creek iredell Yadkin 12-108-20 C ' If unnamed, indicate unnamed tributary to X", where X is the named waterbody to which the unnamed tributary joins. ! certify that as a Registered Professional Engineer in the State of North Carolina that ! have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief. PE Seal, Signature and Date ***END OF FORM WSCAS-12/07 *** FORM: WSCAS-12/07 Page 1 of 1 COS-FC 006 State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow 1'racking/Acceptance for Sewer Extension Permit Applications (FTSE —10/07) Project Applicant Name: City of Sfats�ee,,.__ Project Name for which flow is being requested: DOT Project . - 8. A No ;Flow Am nendrnent More than one FISE-I0/07 may be required c r n sin le project if the owner cad the If 7P is not responsible for all pump stations along the route of the proposed wastewater flow 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Fourth Creek Wastewater Treatment Plant b. WWTP Facility Permit : NCU31836 c. WWTP facility's permitted Clow d. Estimated obligated flow not yet tributary to the e. WWTP facility's actual avg. flow f Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in M ID 4.0 ___ 210 3.010 0 3.7204 80.51% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Narne Approx. Capacity, MGD Approx. Current Avg. (Firm/Design) Daily Flow, MGD III. Certification Staterrtent: I, Robert W. Hites, Jr., certify that, to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the. receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and ll for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing O Sign Date SEWER NARRATIVE -3819A NCDOT Project: I-40 & 1-77 INTERCHANGE & 1-40 FROM US 21 TO 1-77 STATESVILLE MODIFICATION OF INTERCHANGE AREA CITY OF STATESVILLE PO BOX 1111 STATESVILLE, NC 28687-1111 AECOM TECHNICAL SERVICES OF NORTH CAROLINA, INC. November 2010 PROJECT DESCRIPTION The North Carolina Departme t Transportation (NCDOT) proposes to construct a total of approximately 56' of ', 42' of 6", 850' of 8", 477' of 10" and 521' of 30" gravity sewer with appurtena c s along [-40 and US 21, in the City of Statesville, Iredeil County. The construction will provide sewer relocation and upgrade of material as part of the 1-40 & 1-77 interchange modification project. There are no additional or new service connections planned as part of this construction. The project will be constructed prior to the interchange work and as part of the highway construction contract. The City of Statesville has reviewed and approved the plans as well as the NCDOT. Note that this sewer work is strictly to upgrade the material and relocate the gravity sewer to allow for the 1-40 & 1-77 interchange modification. Other permits/certifications (Wetland/Stream Crossing, Sedimentation and Erosion Control Plan and Stormwater) will be submitted as necessary as a part of roadway construction planning. 'f/ ill Zef J SS 8 Submitted By: 4 ''42 D 1 Larry W. Mitchell, PE SAL �2f fl�3 a� 6 e ,. _d+o® ,,,„3 1" SEWER NARRITIVE I-3819A Water Line Standard Materials • For water line construction, the following•specific materials or brands are considered acceptable for the City of Statesville's system. Fire Hydrants: All must have National Standard Threads, 4 z inch valve openings, and open left (counter -clockwise). American Flow Control (American Darling) Mark-73, Mueller Super Centurion 200 and Clow Medallion F-2545 are approved hydrants. Water Valves: All valves must open to the right (clockwise). Quarter turn ball valves should be used on sizes up to 2 inch diameter water lines. Each valve shall have a flat head (such as a corp stop) for on/off operation. Resilient wedge type valves must be used on sizes 2-2 to 10 inch diameter water lines. On 12 inch or larger, butterfly valves with double disc gates must be used. Approved valves are American Flow Control (American Darling), Mueller and Clow. Pipe Materials: All major water mains 6 inch and larger shall be ductile iron class 50 or class 350. Water taps % inch through 1 inch shall be type K soft copper line. Type L hard copper shall be used for 2 inch reduced at the meter for 1 1/2 inch service. Water Meters: All water meters shall be in cubic feet per second. The City can furnish meters (for cost) for application on lines to be dedicated to the City. Size will be determined according to the demand. All meters 3 inch and larger are to have ductile iron pipe to the City side of the meter. Fittings shall be brass for 3/ inch through 1 inch and be flared or compression type. Fittings for 2 inch shall be compression only. Approved types are Ford, Mueller, and McDonald. Approved meter boxes are Brooks #1419 for 3/ inch through 1 inch services and Brooks # 1730 for 2 inch services. All boxes must be 18 inch deep with plastic lid and cast iron readers. Any prefabricated meter vault not installed by the City must be pre approved by the City Engineer. Tapping Sleeves: The following area approved standards: American Flow Control (American Darling) - Mechanical Joint. Mueller - Mechanical Joint Romac - Stainless steel with ductile iron flange. SEAL 023885 fit, a�C, ��. vV r��7 'ftilll� 7° ifm §-1;\ � CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT WATER LINES DETAIL # REVISED w-1 WAY2010 Standard Materials SCALE: SHEET # l-- -:=712v71E • CAS- N.T.S. 1 OF 1 ROADWAY RAW OPTIONAL 3/4" ELL NOTE: 1, METER IS TO BE SET INSIDE OF THE R/W, 2. METER SHALL NOT BE LOCATED IN DRIVE 3. ALL PLASTIC METER BOXES SHALL HAVE CEMENT (PLASTIC) LIDS WITH CAST IRON THE CITY OF STATESVILLE. 4, ALL SERVICE LINES SHALL COMPLY WITH ANGLE METER STOP MUELLER H-14255 2.5' CORPORATION STOP SIDEWALK KEEP LINE AS LEVEL WITH MAIN AS POSSIBLE Section View of Connection WAY. HEAVY DUTY STRENGTH POLYMER VIEWING LIDS AS APPROVED BY AWWA REGULATIONS C800. DUAL CHECK VALVE MUELLER H14242 OR ANY DUAL CHECK VALVE THAT IS A,S.S.E. APPROVED CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT 314" IRON YOKE BAR WATER LINE 3/4"-1" WATER SERVICE TO CUSTOMER WASHED 57 STONE SCALE: N.T.S. REVISED MAY 2010 SHEET # OF 1 ROADWAY 2.5' SIDEWALK ��/�������/�r/��r�������j//// a JI.n= ^_.11#.11#..11•�11 rail. ' 12 SERVICE SADDLE WITH DOUBLE BALE L JI.=I1= 2" TYPE L HARD COPPER CORPORATION STOP MAIN Section View of Connection NOTE: 1. METER IS TO BE SET INSIDE OF THE RNU. 2. METER SHALL NOT BE LOCATED IN DRIVEWAY. 3. ALL PLASTIC METER BOXES SHALL HAVE HEAVY DUTY STRENGTH POLYMER CEMENT (PLASTIC) LIDS WITH CAST IRON VIEWING LIDS AS APPROVED BY THE CITY OF STATESVILLE. 4. ALL SERVICE LINES SHALL COMPLY WITH AWWA REGULATIONS C800. BALL VALVE INLET BYPASS WITH BALL VALVE KEEP LINE AS LEVEL WITH MAIN AS POSSIBLE TO CUSTOMER WASHED 57 STONE ..ter. 12" 31" 24" I— 38" ----I 4" X 6" CAST IRON READER METER WILL BE SUPPLIED BY THE CITY OF STATESVILLE ANGLE CHECK VALVE OUTLET (DOUBLE CHECK) s.es,, -, CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT WATER LINE DETAIL # . REVISED W -2" WATER SERVICE [NDUSTYY•AGIUGULTURE SCALE: SHEET # tAo . V N.T.S. 1 OF 1 -.. � o UNDISTURBED SOIL (TYP,) PIPE SIZE 4" PLAN -BENDS 90" BEND 18" MIN.-10" DIA. OR LESS 24" MIN.-12" DIA, OR GREATER 45° BEND SECTION X-X BENDS & TEES 22-1/2° BEND PLAN -TEES 11-1/4° BEND TEE A 18" A 10" A 10" 7" 10" A 14" 8" 10" 12" 16" 24" 28" NOTES: 12" 18" 22" 28" 38" 10" 15" 19" 18" 28" 36" 10" 12" 14" 18" 12" 15" 10" 12" 14" 18" 2000 PSF SOIL ('SAND & GRAVEL WITH CLAY) 10" 12" 15" 18" 16" 20" 22" 36" 14" 18" 22" 28" 42" 1, BASED ON 200 PSI STATIC PRESSURE PLUS AWWA WATER HAMMER ALLOWANCE. 2, ALL BEARING SURFACES TO BE CARRIED TO UNDISTURBED GROUND. 3. THRUST BLOCKS TO BE USED AT ALL LINES OPERATING UNDER PRESSURE. 4, KEEP ALL PIPING JOINTS CLEAR OF CONCRETE THRUST BLOCKS, CITY OF STA►TESVILLE PUBLIC WORKS DEPARTMENT WATER LINE Thrust Blocking DETAIL REVISED W-4 MAY 2010 SCALE: SHEET # N.T.S. 1 OF 1 OPTIONAL 2° ORIFICE W/ CAP MECHANICAL JOINT PLUG THRUST COLLAR M.J. PLUG PLAN VIEW DUCTILE IRON PIPE MEGALUG 1100 SERIES RESTRAINT OR EQUIVALENT MEGALUG 1100 SERIES RESTRAINT OR EQUIVALENT DUCTILE IRON PIPE ISOMETRIC VIEW NOMINAL PIPE DIAMETER IV "A" "B° TRENCH WIDTH Tr REINFORCING STEEL BARS BARS SPACING WAY) 6" - 8" 12° 12" 26" # 6 12" 10" -12° 16" 16" 30" # 6 6" 16° 21" 21° 36° # 6 6" NOTES: 1. POUR CONCRETE AGAINST FIRM. UNDISTURBED SOIL. FILL AGAINST COLLAR TO BE COMPACTED TO 90% PROCTOR FOR 6' ALONG THE PIPE ON BOTH SIDES OF THE COLLAR. 2. COMPLETELY BACKFILL AND COMPACT BEFORE PRESSURE TEST. 3. TRENCH WIDTHS ARE MAXIMUM FOR 10' EACH SIDE OF COLLAR. rare ; CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT WATERLINE DETAIL # REVISED W-5 MAY2010 Thrust Collar & Dead End INOusrRPAGwculiIIRE - . SCALE' SHEET # _p...��' '3 CEO N.T.S. 1 OF 1 2,_6" HYDRANT SHALL OPEN TO THE LEFT 4" STORZ CONNECTION '-6" MIN. C.Y. #57 WASHED STONE CONCRETE THRUST BLOCKING USE VALVE BOX STABILIZER PAD WHEN PLACED IN AREAS SUBJECT TO TRAFFIC CONCRETE BRICKS UNDER VALVE BOX NOTES: TYPICAL MEGALUG JOINT RESTRAINT OR EQUVALENT 6" DIA. DUCTILE IRON PIPE RESTRAIN EACH JOINT FROM MAIN TO HYDRANT. 1. SEE CITY STANDARD MATERIALS LIST FOR APPROVED HYDRANTS 2, DO NOT BLOCK HYDRANT DRAIN W/ BLOCKING 3. ALL HYDRANTS SHALL BE YELLOW IN COLOR. 4. HYDRANTS SHALL BE BEHIND SIDEWALK OR AS PER PLANS. (NO HYDRANTS IN SIDEWALKS) 6. ALL JOINTS FROM MAIN TO FIRE HYDRANT MUST BE RESTRAINED. USE MEGALUG OR EQUIVALENT JOINT RESTRAINT. CONTRACTOR MAY USE THREADED RODS AS AN OPTIONAL JOINT RESTRAINT, RODS MUST RUN CONTINUOUS FROM MAIN TO HYDRANT. 6. GATE VALVE SHALL OPEN TO THE RIGHT. CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT WATER LINE Typical Hydrant Connection CONCRETE THRUST BLOCKING AI W-6 REVISE© MAY 2010 SCALE: SHEET # N.T.S. 1 OF 1 DROP LID BOTTOM SECTION NOTES: 1. BODY CASTING TO BE TYLER MANUFACTURE NO. 6855-SERIES, 5-114" SHAFT, SLIP TYPE, OR APPROVED EQUAL. SCREW TYPE NOT ACCEPTED . 2. THE BOTTOM PIECE SHALL BE BEVELED AT THE LOWER END TO FIT AROUND THE STUFFING BOX GLAND AND SHALL REST ON TWO BRICKS UNDER EACH SIDE OF THE BASE. 3. FITS 4" THRU 12" VALVES TOP SECTION 4TA 'E fQ CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT WATERLINE DETAIL # REVISED . . W-7 Y/ r , Standard Valve Box [NDIJSTRY•AG[ XCI1ITURE kE SCALE: SHEET # r' ` N.T.S. 1 OF 1 CgO.' 14' DIAMETER NO. 3 REBAR FINISH GRADE PLAN 9.2 SECTION A -A CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT 23'DIAMETER NO. 3 REBAR A VALVE BOX TOP MARKED WATER PRECAST CONCRETE VALVE BOX WATER ,LINE Valve Box Protector SCALE: SED OF 1 USE PROTECTOR RINGS IN AREAS SUBJECT TO VEHICULAR TRAFFIC (SEE DETAIL) As:// / „... A//i\//>\./://:.", END OF PIPE THREADED WI COUPLING CONCRETE BRICKS 2" SCREW TYPE ELBOW WITH THRUST BLOCKING 21 DIAMETER THREADED GALV. PIPING STANDARD CITY APPROVED VALVE BOX MECHANICAL JOINT PLUG WITH 2" THREADED OPENING MEGALUG RESTRAINED JOINT OR EQUIVALENT EXISTING GRADE CONCRETE BRICKS UNDER VALVE BOX NOTES: 1. TWO INCH BLOW OFF VALVES ARE FOR TEMPORARY USE ONLY. USE A FIRE HYDRANT FOR PERMANENT BLOW OFF VALVE APPLICATIONS. LINE SIZE VARIES SEE PLANS FOR . ACTUAL SIZE THRUST COLLAR SEE STANDARD DETAIL S` ��` ��: CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT WATERLINE DETAIL # REVISED 4 W-9 MAY 2090 Temporary �r p 2 Blow Off Valve }��,�- SCALE: SHEET # t '¢ • �' N.T.S. 1 OF 1 LOCKABLE FLIP TOP FIBERGLASS ENCLOSURE x LOCKABLE FLIP TOP FIBERGLASS ENCLOSURE USE D.I.P. FROM STREET CONNECTION TO BACK SIDE OF RPZ NOTE: FASTEN ENCLOSURE TO SLAB TYP. DETECTOR CHECK INLET SHUTOFF VALVE RELIEF VALVE 12" MIN, PLAN VIEW SECOND SHUTOFF VALVE FIRST SECOND CHECK CHECK SECTION x-x 1. ALL BACKFLOW ASSEMBLYS SHALL BE MAINTAINED BY THE CUSTOMER, 2. ENSURE ASSEMBLY WILL FIT WITHIN FIBERGLASS ENCLOSURE DIMENSIONS BEFORE ORDERING ENCLOSURE. 3. SLOPE CONCRETE PAD TO DRAIN PORTS. 4, ASSEMBLY SHALL BE PLACED ON THE CUSTOMERS PROPERTY, AS AN OPTION, THE ASSEMBLY MAY BE PLACED INSIDE OR BESIDE THE BUILDING. IT IS NOT MANDATORY IT BE PLACED AT THE R.O.W, 5, ASSEMBLY SHALL BE ACCESSIBLE BY CITY INSPECTORS. 8. TAMPER SWITCH WITH ALARM SHALL BE SUPPLIED ON METER WHEN USED FOR FIRE LINE APPLICATIONS. 7, METER SHALL READ IN CUBIC FEET, 8. AS AN OPTION THE ASSEMBLY MAY BE PLACED IN A BELOW GROUND VAULT. THE VAULT SHALL BE APPROVED BY THE CITY ENGINEER, CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT INSTALL 120V RECEPTACLE WITH GFCI FOR HEATER CONNECTION TO ENSURE ASSEMBLY DOES NOT FREEZE DRAIN PORT TYPICAL EACH SIDE ISOMETRIC VIEW OF TYPICAL ENCLOSURE WATER LINE Reduced Pressure Detector Assembly For High Hazard Applications (Above Ground) D W-1© REVISED MAY 2010 SCALE: SHEET # N.T.S. 1 OF 1 KABLE FLIP TOP FIBERGLASS ENCLOSURE X PLAN VIEW LOCKABLE FLIP TOP FIBERGLASS ENCLOSURE USE D.I,P. FROM ;TREET CONNECTION '0 BACK SIDE OF RPZ SECTION X-X NOTE: 1. ALL BACKFLOW ASSEMBLY'S SHALL BE MAINTAINED BY THE CUSTOMER. 2. ENSURE ASSEMBLY WILL FIT WITHIN THE FIBERGLASS ENCLOSURE. CHECK DIMENSIONS BEFORE ORDERING ENCLOSURE. 3. SLOPE CONCRETE PAD TO DRAIN PORTS. 4. ASSEMBLY SHALL BE PLACED ON THE CUSTOMERS PROPERTY, AS AN OPTION, THE ASSEMBLY MAY BE PLACED INSIDE OR BESIDE THE BUILDING. IT IS NOT MANDATORY IT BE PLACED AT THE R.O.W. 5. ASSEMBLY SHALL BE ACCESSIBLE BY CITY INSPECTORS. 6. TAMPER SWITCH WITH ALARM SHALL BE SUPPLIED ON METER WHEN USED FOR FIRE LINE APPLICATIONS. 7. METER SHALL READ IN CUBIC FEET. B. AS AN OPTION THE ASSEMBLY MAY BE PLACED IN A BELOW GROUND VAULT. THE VAULT SHALL BE APPROVED BY THE CITY ENGINEER. J INSTALL 120V /RECEPTACLE WITH GFCI FOR HEATER CONNECTION DRAIN PORT TYPICAL EACH SIDE 16\ V_ b ISOMETRIC VIEW OF TYPICAL ENCLOSURE .S` . ue, �' • CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT 3" r WATER LINE DETAIL # REVISED W-11 MAY2010 1 0" DCV Assembly (Above Ground) INDLIFIRY•AGRICULTURE SCALE: SHEET # t_ �r �. � .! ei ,� N.T.S. 1 OF 1 co LOCKABLE FLIP TOP FIBERGLASS ENCLOSURE LOCKABLE FLIP TOP FIBERGLASS ENCLOSURE. USE COPPER FROM STREET CONNECTION TO BACK SIDE OF DCV. NOTE; BRONZE 1/4 TURN SHUT OFF VALVES PLAN VIEW VARIES BRONZE 1I4 TURN SHUT OFF VALVES CONCRETE SLAB 3000PSI@28DAYS (CHECK ENCLOSURE SIZE FOR SLAB DIMENSIONS) SECTION X-X 1. ALL BACKFLOW ASSEMBLY'S SHALL BE MAINTAINED BY THE CUSTOMER. 2. ENSURE ASSEMBLY WILL FIT WITHIN FIBERGLASS ENCLOSURE. CHECK DIMENSIONS BEFORE ORDERING ENCLOSURE. 3. SLOPE CONCRETE PAD TO DRAIN PORTS. 4, ASSEMBLY SHALL BE PLACED ON THE CUSTOMERS PROPERTY, AS AN OPTION, THE DCV MAY BE PLACED INSIDE OR BESIDE THE BUILDING. IT IS NOT MANDATORY IT BE PLACED AT THE R,O.W, 5. ASSEMBLY SHALL BE ACCESSIBLE BY CITY INSPECTORS. 6. METER SHALL READ IN CUBIC FEET. 7. AS AN OPTION THE ASSEMBLY MAY BE PLACED IN A BELOW GROUND VAULT, THE VAULT SHALL BE APPROVED BY THE CITY ENGINEER. CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT WATER LINE INSTALL 12OV RECEPTACLE WITH GFCI FOR HEATER CONNECTION DRAIN PORT TYPICAL EACH SIDE ISOMETRIC VIEW OF TYPICAL ENCLOSURE DETAIL # W-12 -Z - Z'r DCV Assembly (Above Ground) REVISED SCALE: N.T.S. SHEET # 1 OF 1 SHOULDER RIGHT OF WAY PAVED ROAD WIDTH 5' MIN - SHOULDER w IZ w 0 w 5' MIN~ II z USE APS MODEL AC PULL -ON END SEAL OR EQUIVALENT OPTIONAL: COMPLETELY GROUT ENDS OF CASING PIPE. ADD A WEEP HOLE ON LOW SIDE FOR DRAINAGE. PAVED ROADWAY STEEL CASING PIPE SEE CHART BELOW D.I. RESTRAINED JOINT CARRIER PIPE PLACE SPIDERS BEHIND BELLS AND ALONG MID -SPAN OF PIPE CARRIER PIPE CASING PIPE RAILROAD HIGHWAY NOMINAL DIAMETER OUTSIDE DIAMETER OUTSIDE DIAMETER WALL THICKNESS OUTSIDE DIAMETER WALL THICKNESS 6" & SMALLER 6.90" 12-3/4" 0.188" 12-314" 0.250" 8" 9.05" 16" 0.250" 16" 0.250" 10" 11.10" 20" 0,281" 20" 0.250" 12" 13.20" 24" 0.344" 24" 0.250" 14" 15.30" 28" 0.406" 28" 0.312" 16" 17.40" 30" 0.406" 30" 0.312" 20" 21.60" 42" 0.563" 42" 0,312" 24" 25.80" 42" 0.563" 42" 0.312" NOTES: �I rl fi U SPIDER 1. ALL ROAD CROSSINGS SHALL BE AS CLOSE TO PERPENDICULAR WITH THE ROADWAY AS POSSIBLE OR AS DIRECTED BY THE CITY ENGINEER. 2. ALL SEWER PIPE FROM MANHOLE TO MANHOLE AT HIGHWAY CROSSINGS SHALL BE DUCTILE IRON. 3. INSTALLATION OF CASING SHALL BE DRY BORE AND JACK. 4. STEEL CASING PIPE SHOULD BE GRADE B STEEL WITH A MINIMUM COMPRESSIVE STRENGTH OF 35,000 PSI IN ACCORDANCE WITH ASTM A139 AND A283. 5. CARRIER PIPE IS TO BE D.1.P. RESTRAINED JOINT. 6. GREASE ENCASEMENT AS REQUIRED FOR EASE OF INSTALLATION. 7. HOT DIP GALVANIZE ALL STEEL ASSEMBLY PARTS AFTER FABRICATION. 8. CADMIUM PLATE ALL NUTS & BOLTS. IF 36" MIN. STATESGr� °� • CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT WATER LINE DETAIL # REVISED W-13 MAY2010 yore Under Paved Roadways INDUSTRY•AGRICULTURE i SCALE: SHEET # A 4..L.' N.T.S. 1 OF 1 NEW ASPHALT "SUPERPAVE S9.58" TO MATCH EXISTING PAVEMENT THICKNESS OR 2.5" MIN, COMPACTED ABC STONE COMPACTED BACKFILL COMPACT SELECT BACKFILL IN 6" LIFTS ( MATERIAL NO LARGER THAN 1" ) NOTES: SEE NOTE SEE NOTE # 2 0 SAW CUT JOINTS 1. WHEN IN ROCK OR NON -CUSHIONING MATERIAL PLACE A BED OF # 57 STONE AT LEAST 6" THICK BELOW MIDPOINT OF PIPE FOR TRENCH DEPTH'S UP TO 16', WHEN TRENCH IS GREATER THAN 16' DEEP' PLACE AN ADDITIONAL 1" OF CUSHIONING STONE FOR EACH 2' OF DEPTH UP TO A MAXIMUM CUSHIONING DEPTH OF 12". 2. WHERE UNSUITABLE SOIL IS ENCOUNTERED, EXCAVATE THE SOIL AS DIRECTED BY THE ENGINEER AND BACKFILL WITH #57 STONE.' 3, BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. 4, WHEN WORKING WITHIN NCDOT RIGHT-OF-WAYS IT MAY BE REQUIRED TO ADD A ONE (1) INCH ASPHALT OVERLAY OVER AND AROUND THE CUT AREA. CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT WATER LINE EXISTING PAVEMENT EXISTING STONE OVERLAP NEW ASPHALT AND STONE 12" MIN. RACE TRENCH AS REQUIRED BY EXISTING SOIL CONDITIONS PIPE DIAMETER LESS THAN 14" 14" TO 36" MORE THAN 24" Trench, Bedding, & Backfill in Paved Roads 12" 24" DE'"AIL # REVISED W-14 MA'Y2©10 SCALE: SHEET # N.T.S. 1 OF 1 LOOSE BACKFILL HEAPED UP TO PROMOTE VEGETATION GROWTH COMPACTED BACKFILL . . . * W W Y W W W W 4, W 4, W 4, . . . W I • • lJ I I �13 1 COMPACT SELECT _ BACKFILL IN 6" LIFi• , •' ( MATERIAL NO = . . LARGER THAN 1") SEE NOTE # 1 SEE NOTE # 2 NOTES: 4, W ,Y W W •l• W W W * W W W * W BRACE TRENCH AS REQUIRED BY EXISTING SOIL CONDITIONS W W W W W W W •Y PIP 0.P' W 7 PIPE DIAMETER * LESS THAN 14" 12" 14" TO 36" 18" MORE THAN 24" 24" 1. WHEN IN ROCK OR NON -CUSHIONING MATERIAL PLACE A BED OF # 57 STONE AT LEAST 6" THICK BELOW • MIDPOINT OF PIPE FOR TRENCH DEPTH'S UP TO 16'. WHEN TRENCH IS GREATER THAN 16' DEEP PLACE AN ADDITIONAL 1" OF CUSHIONING STONE FOR EACH 2' OF DEPTH UP TO A MAXIMUM CUSHIONING DEPTH OF 12"• 2. WHERE UNSUITABLE SOIL IS ENCOUNTERED, EXCAVATE THE SOIL AS DIRECTED BY THE ENGINEER AND BACKFILL WITH #57 STONE. 3. BACKFILL SHALL BE COMPACTED TO 95% STANDARD PROCTOR DENSITY. s p _'''. CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT WATERLINE DETAIL # REVISED W 15 MAY 2010 Trench,Bedding, & Backfill Off Road SCALE: SHEET # . .-Y--. 4!, N.T.S. 1 OF 1 o 0 AS31V1S JO ALL HYDRANTS TO BE PAINTED YELLOW BY THE MANUFACTURER TYPICAL VALVE BOX WI COLLAR CORP. STOP /4"'TYPE K COPPER PIPE MEGALUG JOINT RESTRAINT OR EQUIVALENT 45° SEWER MAIN MIN, 4" CLEANOUT WITH BRASS PLUG RESIDENTIAL WATER METER SIDEWALK BEND PIPE AS TIGHT AS POSSIBLE WITHOUT KINKING PIPE CH. 40 PVC SERVICE L!NE SLOPED L2 WYE FITTING A .... Y I UNDISTURBED EARTH , I I=I I I I I� BEHIND BLOCKING -I 11=i I I - CONCRETE BLOCKING 1 I 1=1 I 11-7141 UNDISTURBED EARTH 111 I TAPPING SLEEVE CONCRETE BLOCKING EXISTING LINE ' ' I'=111--111-11 F- III lI1,;1IIgII,;,IiI-,_ III--- ! I I -III -III- -III-I I Il --III ;111-11 lfl 11; I 1 r- ;__ r���,,,lil-'' PLAN VIEW USE VALVE BOX STABILIZING PAD WHEN PLACED IN AREAS SUBJECT TO TRAFFIC VALVE BOX (SEE DETAIL) CONCRETE BRICKS UNDER VALVE BOX M.J. GATE VALVE MEGALUG JOINT RESTRAINT OR EQUIVALENT \ \J`�!` • %��/�% UNDISTURBED EARTH /ry/i CONCRETE BRICK BLOCKING COMPACTED EARTH SECTION A -A NOTES: 1. THE GATE VALVE SHALL OPEN TO THE RIGHT. 2. USE FULL BODY TAPPING SLEEVE WITH GASKET AND MECHANICAL JOINT OUTLET. 3. CONCRETE BLOCKING IS TO BE FORMED TO ENSURE ACCESSIBILITY TO FITTINGS AND POURED AGAINST UNDISTURBED EARTH. 4. FITTINGS ARE TO BE COMPLETELY WRAPPED WITH PLASTIC, PRIOR TO POURING CONCRETE. 5. CONCRETE TO BE MINIMUM 3,000 PSI. @ 28 DAYS. 70°1716'st °�4, CITY OF STATESVILLE PUBLIC WORKS DEPARTMENT WATER LINE DETAIL # REVISED W 17 - r Ta in Sleeve x iiiii iNw'O_Sd'{sry111I is„ SCALE: SHEET # � �' zC CAst. N.T.S. 1 OF 1 CONSTRUCTION NOTES: 1. ALL WORK SHALL BE COORDINATED WITH THE CITY OF STATESVILLE, THE DESIGN ENGINEER, THE N.C. DEPARTMENT OF TRANSPORTATION, ALL GAS, TELEPHONE, & POWER UTILITIES, AND ANY OTHERS AS REQUIRED. 2. ALL WATER LINES INSTALLED ON SECONDARY ROADS SHALL BE ACCORDING TO THE NCDOT "'POLICIES AND PROCEDURES FOR ACCOMMODATING UTILITIES ON HIGHWAY RIGHT-OF-WAYS" MANUAL. 3. TAKE PROPER PRECAUTIONS NOT TO DISTURB EXISTING PROPERTY CORNERS. ANY NECESSARY REMOVAL AND RESETTING OF PROPERTY IRONS SHALL BE DONE BY A REGISTER LAND SURVEYOR, 4, FENCES DAMAGED DURING CONSTRUCTION MUST BE REPLACED. USE TEMPORARY FENCING TO PREVENT ESCAPE OF LIVESTOCK. 5. ALL RIGHT-OF-WAYS SHALL BE GRADED, SHAPED, SEEDED AND STABILIZED AFTER CONSTRUCTION IS COMPLETE. 6, ALL RIGHT-OF-WAYS SHALL BE GRADED IN A MANNER AS TO NOT ALLOW ANY STANDING WATER. 7. ANY EXCAVATED WOOD, ROCKS, AND/OR DEBRIS SHALL BE DISPOSED OF OFF SITE BY THE CONTRACTOR. NO ONSITE BURYING WILL BE ALLOWED. 8. ANY TREES SCARRED DURING CONSTRUCTION SHALL HAVE THE SCARS TRIMMED AND PAINTED WITH ASPHALT -BASE TREE PAINT. 11. PLUG ALL PIPE OPENINGS AND FILL ANY EXPOSED TRENCHES AT THE END OF THE DAY. 12. D0 NOT TIE NEW WATER LINES INTO EXISTING WATER LINES UNTIL AUTHORIZED BY LOCAL AND STATE AUTHORITIES. 13. THE USE AND STORAGE OF EXPLOSIVES SHALL CONFORM TO LOCAL, STATE, AND FEDERAL LAWS. 14. COSTS OF CONCRETE COLLARS AND PLUGS SHALL BE INCLUDED IN THE UNIT PRICE OF PIPE UNLESS OTHERWISE NOTED IN THE PROPOSAL. 15, .COSTS OF ADAPTERS, ETC REQUIRED FOR CONNECTIONS OF PVC, C.I., AND D.I. PIPE SHALL BE INCLUDED IN THE UNIT PRICE OF PIPE. 16. ALL FENCES CROSSED DURING CONSTRUCTION SHALL BE REPLACED WITH FENCE OF LIKE MATERIAL. INCLUDE A NEW 1(Y OR WIDER GATE OF LIKE MATERIAL AT EACH FENCE CROSSING FOR ACCESS. COST OF REPLACING FENCES AND PROVIDING GATES SHALL BE INCLUDED IN UNIT PRICE BID PER LINEAR FOOT OF PIPE, 17. ANY PIPES WHICH MUST BE INSTALLED INSIDE A DITCH OR AT A CREEK CROSSING TO ALLOW ACCESS DURING CONSTRUCTION SHALL BE REMOVED ONCE CONSTRUCTION IS COMPLETE UNLESS OTHERWISE SPECIFIED. SAID PIPE SHALL BE NO LESS THAT 12" DIAMETER UNLESS OTHERWISE DETERMINED BY THE DESIGN ENGINEER., COST FOR INSTALLING THIS PIPE SHALL BE INCLUDED IN THE UNIT PRICE BID PER. LINEAR FOOT OF PIPE, EROSION CONTROL NOTES 1, ALL SITES ARE SUBJECT TO INSPECTION FOR EROSION CONTROL. 2. ANY LAND DISTURBING ACTIVITIES OF 1 ACRE OR MORE (1/2 ACRE WITHIN A PROTECTED WATERSHED AREA) SHALL REQUIRE A LAND DISTURBING PERMIT FROM THE IREDELL COUNTY PLANNING DEPARTMENT. 3, IT IS THE CONTRACTORS RESPONSIBILITY TO MONITOR AND MAINTAIN ALL EROSION CONTROL PRACTICES IN AND AROUND THE SITE, 4. AS PER N.C..G.S. 113A.-57(2),..IN ANY EVENT, SLOPES LEFT EXPOSED WILL, WITHIN 21 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY OR PERMANENT GROUND COVER, DEVICES, OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION. 5. PURSUANT TO N.C.G.S. 113A,-57(3)...PROVISIONS FOR A GROUND COVER SUFFICIENT TO RESTRAIN EROSION MUST BE ACCOMPLISHED WITHIN 15 WORKING DAYS OR 90 CALENDAR DAYS FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT, WHICHEVER IS SHORTER, EXCEPT AS PROVIDED IN 15A NCAC 4B .0124(e). 6, ADDITIONAL EROSION CONTROL MEASURES NOT SHOWN ON PLANS MAY BE REQUIRED IF STABILIZATION IS NOT ACHIEVED WITHIN SPECIFIED TIME LIMITS OR IF UNDUE SEDIMENTATION OCCURS. CFTY OF STATESVILLE PUBLIC WORKS DEPARTMENT WATER LINE General Notes REVISED MAY 2010 CALE: ° SHEET # N.T,S. 1. OF _ 1 Permit Number WQ0035166 Central Files: APS_ SWP_ 01/05/11 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Coastal SW Rule Permitted Flow 0 Facility Facility Name Major/Minor Region I-3819A Minor Mooresville Location Address County Iredell Facility Contact Affiliation Owner Owner Name Owner Type City of Statesville Government - Municipal Owner Affiliation Robert W. Mites Jr. PO Box 1111 Statesville Dates/Events NC 286871111 Orig Issue App Received Draft Initiated 12/23/10 Schedufed Issuance Public Notice Issue Effective Expiration Regulated Activities Re. uested/Received Events Retail Additional information received Subdivision Wastewater collection Outfall NULL Additional information requested 12/30/10 Waterbody Name Stream Index Number Current Class Subbasin Permit No. WQ0035166 January 6, 2011 Own eriWQCSFWWTP Robert Hites, City Manager City of Statesville PO Box 1111 Statesville, NC 28687 Complete and submit th' f • One copy of the project system extension PE Larry faiitceli Af;COM Technical Services of N4 ,Inc 701 Corporate Center Drives, Suite 475 Raleigh, NC 27607 m to the permit issuing regional i ce with the fcilowr ,cord drawings (plan & profile views of sewer lines) of the wastewater collection Supporting design calculat€ens (selected pumps, system cu generator(s) or storage greater than longest past three year stations permitted as part of this project Changes to the project should be clearly id n't'fled on the record drawin icatbcn are revs ed for any changes resulting in non-compliance with (hid permit, regulations OF €minirrturp design crwteria_ perating point, available storage if portable ie reliability option selected) for any pump written summary or Permit This project shall not be considered complete nor allowed to operate unt8 this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINffFeS CERTIFYGATC0N © Partial (inai p;w a duly registered Professional Engineer in the State of North Carolina, having been aufhor e to observe ( (aer od tally, 0 weekly, 14fult time) the construction of lk'3819A, an lredeit County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built Within substantial compllarlce of thispermit; 15A NCAC 2T: the Division of vWater Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other Supporting materials, North Carolina Professional Engineer's seal, signature,and date: ri�yrawas�wrra�., T. wrastewate Engineer's C enforcement actions, SEND THIS FORM SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS sible for tracking ail tributary to the wastewa I to considered a vi MOORESVILLE REGIONAL OFFICE. SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 rtifcations up until a final certification is received Any section system extension prior to completion of this In of the perrnit and shall subject the Permittee to appropriate