Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0033779_Regional Office Historical File Pre 2018
I AWA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary February 11, 2009 . Mr. Al King, President Alton Properties, LLC 1150 Crews Road, Suite H Matthews, NC 28105 Subject: Permit No. WQ0033779 Preventech Wastewater Collection System Extension Iredell County, North Carolina Dear Mr. King, In accordance with your application received on January 28, 2009, we are forwarding herewith Permit No. WQ0033779 dated February 11, 2009, to the Alton Properties, LLC for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. it shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities,and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office Location: 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 1 Fax: (704) 663-6040 % Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.orq a„ Fr. sal r t,nnrh inifv t Altirmative Action Emotover — 50% Recvctedl10% Past Consumer paper None rthCarol ina ‘/I?aturally rMr. King 2 February 11, 2009 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the AQUA North Carolina, Inc. for the construction and operation of approximately 678 linear feet of 6-inch gravity and the discharge of 2,875 gallons per day of domestic wastewater into the existing sewerage system in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Union County WWTP (Crooked Creek NPDES Permit No. NC0069841) prior to being discharged into the receiving stream. Assessing subsequent impacts to the downstream collection system and treatment facility is the complete responsibility of Union County. Union County must utilize whatever tracking tools necessary for planning additions of sewer flow in order to maintain compliance with the WWTP permitted limits and the collection system permit WQCS00054. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699. erely, / for Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permit Files R. Todd Fisher, ColeJenest & Stone, PA Surface Water Protection Central Files PERCS I NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2E...0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 I 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies . (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 I Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 11th day of February, 2009. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION 1(...1_ for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0033779 3 v t Track Engineering mit No. WQ0033779 February 11, 2009 OwnerNVWTP/WQCS Al King, President Alton Properties, LLC 1150 Crews Road, Suite H Matthews, NC 28105 Certification PE R. Todd Fisher ColeJenest & Stone, PA 200 S. Tryon Street, Suite 1400 Charlotte, NC 28202 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION El Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Preventech, a Union County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. 0 z LL USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! 1, Owner/Permittee: la. Alton Properties, LLC Full Legal Name (company, municipality', HOA, utility, etc.) lb. Al King, President Application Number: (to be competed by DWQ 337 7 Signing Official Name and 'Title (Please review 15A NCAC 2T ,0106 (b) for authorized signing officials!) lc, The legal entity who will own this system is: 0 Individual 0 Federal 0 Municipality 0 State/County Private Partnership 0 Corporation 0 Other (specify): ld, 1150 Crews Road, Suite H Mailing Address if, North Carolina State lh, 704-849-2416 Telephone li 704-849-2417 Facsimile (..) 2, Project (Facility) information: .j 2a Preventech CI. CL. 3' Brief Project Name (permit will refer to this name Contact Person: • 3a, R, Todd Fisher, ColeJenest & Stone, PA Name and Affiliation of Someone Who Can Answer Que 3b, 704-376-1555 tfishe Phone Number E-mail 0 0 z w le Matthews City 1g, 28105 Zip Code 1j, alking@preventech,com E-mail 2b. Union County Whe ut this Application 'eneststone.com Project is Located 1_ Project is New 0 Modification (of an existing permit) tf Modification, Permit No,: 2, Owner is Li Public (skip to Item B(3)) 2a. If private, applicant will be: E Private (go to Item 2(a)) 2b, If sold, facilities owned by a (must choose one) Retaining Ownership (i e, store, church, single office, etc,) or o Leasing units (lots, townhomes, etc. - skip to Item B(3)) Selling units (lots, townhomes, etc, - go to Item B(2b)) 3. Union County Owner of Wastewater Treatmen 4a Crooked Creek Name of WWTF Ej Public Utility (Instruction C) 0 Homeowner Assoc /Developer (Instruction D) y (WWTF) Treating Wastewater From This Project 4b, NC0069841 WWTF Permit No, 5a, Union Coun 5b. 8-inch Gravity 5c, WQ0001160 Owner of Downstream Sewer Receiving Sewer Size 0 Force Main Permit # of Downstream Sewer (Instruction E) 6. The origin of this wastewater is (check all that app(y) - El Residential Subdivision 0 Apartments/Condominiums 0 Mobile Horne Park 0 School 0 Restaurant Office 0 Retail (Stores, shopping centers) InstItution 0 Hospital 0 Church El Nursing Home 0 Other (specify): 7. Volume of wastewater to be allocated or permitted for this particular project: *Do not include future flows or previously permitted allocations 8. If the permitted flow is zero, indicate why: 100 % Domestic/Corn mercial % Industrial (attach descript(on.) (RO: contact your Regional Office Pretreatment staff) % Other (specify): 2,875 gallons per day 0 Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No, 0 Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) ETA .1 107 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 fors, the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). Office use = 25 gpd/employee x 115 maximum employees = 2,875 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) New Gravity or Additional Size (inches) Length (feet) Force Main 6 678 gravity I Force Mains to be Permitted (attach ❑ 11. Summary of Pump Stations M Pump Station Location ID Z-- - -- ------ }" Design Flow Z (MGD) 0 w1 associated additional sheets as necessary) as_ shown on plans/map for reference) T - — - - I I Force Main Size i Force Main Length , L (self chosen_- ----T -- - - -- ---- j Power Reliability Option Operational Point, GPM @TDH ' 1 - permanent generator wIATS; i 2 - portable generator wIMTS �.. -- - -- - -- - - - 1 I z QPump Station Location ID (self chosen - as shown on planslmap for reference) n Design Flow Et (MGD) 02 LL Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w/ATS; - portable generator wIMTS 1 Force Main Size. Force Main Length Z 1-- ce Pump Station Location ID (self chosen - as shown on plans/map for reference) W a, Design Flow (MGD) ro Operational Point GPM @TDH ( f I Power Reliability Option 1 - permanent generator w!ATS; Force Main Size I Force Main Length 2 - portable generator w/MTS T 12. Will the wastewater flow in the proposed sewer number of 2nd treatment contact the Central comply with the Minimum Gravity Sewer Minimum please reference the is requested. SUBMIT TO THE VARIANCE lines or pump stations be able to be directed to another treatment facility? facility • Yes ® No If Yes, permit (RO - if "yes" to B,12 please 13. Does the sewer system Mains (latest version), the applicable? Office PERCS Unit) Design Criteria for the Fast Track Permitting of Pump Stations and Force Design Criteria (latest version) and 15A NCAC Chapter 2T as pertinent minimum design criteria or regulation and indicate why a TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS WITH YOUR APPLICATION ► Yes • No If No, variance PERTINENT FTA 12/07 4. Have the following perrnitstcertifications been submitted for approval for the system or project to be sensed? Wetland/Stream Crossings - General Per t or 401 Certification? ® Yes 0 No LJ NtA Sedimentation and Erosion Control Plan? Yes © No 0 NIA. Stormwater'? Q Yes Lj No [] N/A 15, Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)] involve aerial Mines, siphons, or 'interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: ❑ and provide details 1a.. Owner/Perrmttee"s Certification: (Signature of Signing Official and Project Name) I, Al King attest that this application for .._ Preventech _ has been reviewed by me and is accurate and complete to the bestof my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: in accordance with North Carolina General Statutes 143-215,6A and 143-215,68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 violation, Signing Official Signature Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION, THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY u) TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC, REFER TO 15A NCAC 02T .0305 z 0 16- 2. Professionat Engineer's Certification: (Signature of Design Engineer and Project Name) 1, R. Todd Fisher , attest that this application for Preventechhas been reviewed by me and is accurate, complete and consistent with the information in the engineeri'rtg plans, calculations, and all other supporting documentation to the best of my knowledge, I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that l have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement„ representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violaGan. 2a, R. Todd Fisher Professional Engineer Name 2b, ColeJenest & stone, PA Engineering Firm 2c. 200 S. Tryon Street, Suite 1400 Mailing Address 2d. Charlotte City 2e. NC 21, 28202 State Zip 2g. 704-376-1555 2h. 704-376-7851 21, tfisherr;,7a colejeneststone.com Telephone Facsimile E-mail F / 12,`tb7 TerraServer Image Courtesy of the USGS Page Send To Printer Back To TerraServer Change to 11x 17 Print Size Show Grid Lines Change to Portrait MSS km E of Indian TraiUnited States 01 _Jul 1988 Image courtesy of the U.S. Geological Survey 2004 Microsoft Corporation. Terms of Use Privacy Statement http://terraserver-usa.corn/printimage.aspx?T=2&S= 12&X=664&Y=4852&I= 17&'=2+km+E+of+Indian+Trail%2c+North+Car... I /7/2009 North Carolina Secretary of State Page 1 of 1 North Carolina Elaine F. Marshall DEPARTMENT OF THE Secretary SECRETARY OF STATE PO Box 29822 Raleigh, NC 27626-0622 (919)607-2000 CORPORATIONS Corporations Home Search By Corporate Name Search For New Corporation Search By Registered Agent Important Notice Resale of Tickets Online Corporations FAQ Homeowners' Association FAQ Tobacco Manufacturers Unincorporated Non -Profits Dissolution Reports Non -Profit Reports Verify Certification Online Annual Reports LINKS-E. LEGISLATION KBBE B2B Annual Reports SOSID Number Correction 2001 Bill Summaries 1999 Senate Bills Annual Reports 1997 Corporations 1997 Register for E-Procurement Dept. of Revenue ONLINE ORDERS Start An Order New Payment Procedures CONTACT US Corporations Division , TOOLS Secretary of State Home Secretary of State Site Map Printable Page Date: 1/28/2009 Click here to: View Document Filings l Sign Up for E-Notifications l '11TIPrint apre-populated Annual Report Form I Annual Report Count l File an Annual Report l Corporation Names Name Name Type NC Alton Properties, LLC Legal Limited Liability Company Information SOSID: Status: Date Formed: Citizenship: State of Inc.: Duration: Registered Agent 0925116 Current -Active Domestic NC Perpetual Agent Name: Registered Office Address: Registered Mailing Address: Principal Office Address: Principal Mailing Address: King, Fred Alton 1150 Crews Road, Suite H Matthews NC 28105 1150 Crews Road, Suite H Matthews NC 28105 1150 Crews Road, Suite H Matthews NC 28105 1150 Crews Road, Suite H Matthews NC 28105 http://www.secretary.state.nc.us/corporations/Corp.aspx?PitemId=8199928 1/28/2009 Central Files: APS SWP_ 02/11/09 Permit Number WQ0033779 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer 1.00 Individual Extensions Primary Reviewer Permit Contact Affiliation dee.browder Permitted Flow 2875 Facility Facility Name Major/Minor Region Preventech Minor Mooresville Location Address County 4330 Matthews -Indian Trail Rd Union Indian Trail NC 28079 Owner Facility Contact Affiliation Brett Hannaford 2115 Rexford Rd Charlotte NC 28211 Owner Name Owner Type Individual AI King Owner Affiliation Al King 4330 Matthews -Indian Trail Rd Indian Trail NC 28079 Dates/Events Orig Issue App Received 02/11/09 01/28/09 Scheduled Draft Initiated Issuance Public Notice Issue 02/11/09 Effective Expiration 02/11/09 Regulated Activities e. ues edlReceived Events Additional information requested industrial and commercial machinery menu Pump and haul Wastewater collection Outfall NULL Additional information received Waterbody Name Stream Index Number Current Class Subbasin