Loading...
HomeMy WebLinkAboutWQ0030774_Regional Office Historical File Pre 2018Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality September 13, 2006 Mr. James Justice, Town Manager PO Box 878 Mooresville, NC 28115 Subject: Permit No. WQ0030774 Timber Ridge Expansion Project Wastewater Collection System Extension Iredell County, North Carolina Dear Mr. Justice, In accordance with your application received on September 5, 2006, we are forwarding herewith Permit No. WQ0030774 dated September 13, 2006, to the Town of Mooresville for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Town of Mooresville for the construction and operation of approximately 3,267 linear feet of 8-inch gravity sewer and the discharge of 8,750 gallons per day of collected domestic wastewater into the Town of Mooresville existing sewerage system, pursuant to the Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet: www.ncmwaterquality.org Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer-50% Recycledll0% Post Consumer Paper NQ Caro ina )Vatura'// Mr. Justice Page 2 September 13, 2006 application received September 5, 2006, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Town of Mooresville WWTP (Rocky River NPDES No. NC0046728) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Marcia Allocco at (704) 663-1699. Sincerely, for Alan W. Klimek, P.E. cc: Mooresville Regional Office, Surface Water Protection (WWTP Permit No. NC0046728) Dan Brewer, Chas. H. Sells, Inc. Surface Water Protection Central Files Mina Leach, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the - following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's - (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or -the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 13th day of September, 2006. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek, P Fes, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0030774 3 Fast Track Engineering Certification Permit No. WQ0030774 September 13, 2006 Town of Mooresville PO Box 878 Mooresville, NC 28115 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resultinq'in non-compliance with this permit. regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial ❑ Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of Timber Ridge Expansion, a Iredell County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. !�CK ATM for GRAVITY S1";Wt!:Rfti, PUMP SFOR('E NUYINS z z USE THE TAB KEY TO MOVE FROM FIELD TO FIELD 1. Owner: la. Town of Mooresville Full Legal Name (company, municipality, HO.A, utility, etc,) 1b, Mr. James Justice, Town Manager Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) 1 c. The legal entity who will own this system is: ❑ Individual ❑ Federal Z Municipality ❑ State/County ❑ Private Partnership 0 Corporation ❑ Other (specify): PO Box 878 Street Address 1 f, NC State 1 h. 704-662-7041 704-662-7039 Telephone .._ Facsimile 2. Project (Facflr°ty) Info r at(on: Se S tTimber Ridge Expansion 2b. Irede Application Number: (to be completed by DWJQ! Moore City lg. 28115 Zip Code 1j, E-mai Ile Brief Project Name (permit wilt refer to this name) County Where Project is Located Contact Person: Mr. Dan Brewer, P.E. Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-662-0100 Phone Number Project is New Modification (cif an existing permit) 2, Owner is El Public (skip to Item B(3 2a. If private, applicant will be: 3c. dbrewer a@chashsells.cc E-mail odificati Private (go to Item 2(a)) 2b. If sold, faties owned by a (must choose on ❑ Retaining Ownership (i,e. store, church, single office, etc.) or ❑ Public( tility (Instruction Ill) ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Homeowner Assoc./Developer (Insttruetl+ n IV) ❑ Selling units Imo, to iorn s, etc. - go to Item B(2b)) astewater Treatmertt Facili 4a, Rocky River WWTP Name of WWTF WTF)'Treatin 0 5a, Town of Mooresvmfle 5b, 12" Owner of Downs tream Sewer Receiving Sewer Size 6. The origin of this wastewater is (check all that apply): astewater From This Project 4b, NC Q046728 WWTF Permit No. ❑ Residential Subdivision ❑ Car Wash ❑ Apartments/Condominiums ❑ Institution Mobile Horne Park ❑ Hospital © School ❑ Church Ei Restaurant ❑ Nursing Home Office ®' Other (specify): Retail Permit Number of Down 7. Volume of wastewater to be permitted in this project: 8,750 gallons per day if known 100 % Domestic/Commercial 0'/© 8ndustrial is Other (specify): If the permitted 'flow is zero, indicate why. ❑ Interceptor Line - Flow will be permitted is subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. _ 0 Rehabilitation or replacement of existing sewer with no new flow expected CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 ' I ! p M Z Z V Z Q11. M c 0 LL Z W a CO . Lthe Provide the wastewater flow calculations used .0219(1) for Item B(7) or the design flow for line that in 15A NCAC 2H .0219(1)(1-2) must be Division of Water Quality, Non -Discharge accordance with 15A NCAC 2H .0219(I)(3). in determining the or pump station sizing approved prior to submittal Permitting Unit, 1617 = 8,750 gpd permitted flow in if zero flow in of this application. Mail Service Center, accordance with 15A NCAC 2H the space below. Values other than Submit a separate request to Raleigh, NC 27699-1617 in i I I 14 lots x 25 employees/lot x 25 gallons/employee/day 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) j Size (inches) Length (feet) Gravity or Force Main (pull down menu) 8 3,267 Gravity Gravity Gravity Gravity Gravity Gravity Gravity ENTER TOTAL LINE LENGTH IN MILES 0.62 Summary of Pump Stations to be Permitted (attach additional sheets as necessary) f Location ID Design Flow 1 Operational Point (as shown on plans) (MGD) GPM @ TDH Power Reliability Option (dual line feed, permanent generator w/ATS, portable generator wltelemetry, wet well storage) i I 1 12. SUBMIT Does the sewer system comply with the Minimum Mains (latest version), the Gravity Sewer Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? pertinent minimum design criteria or regulation and indicate why a OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION ►�1 Yes IN No If no, please reference the variance is requested: TWO COPIES OF PLANS, SPECIFICATIONS 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erosion Control Plan? Stormwater? • Yes • No 11 NIA ® Yes ❑ No • N/A 0 N/A ❑ Yes • No FTA 02/03 CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 Ir Z O 1-t Q 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: 100 feet away from any slope ❑ A Stream Classification is not needed because all parts of the project are at leas downlope waterbody; AND V LL. • A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. U) Location ID on Maw Name of Waterbody i County River Basin Waterbody Stream Index Waterbody Classification 0 A West Branch Rocky Iredell River Yadkin 13-17-3 C a 111 Ce co Submit the 8.5" x 11" topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: 1, Mr. James Justice, attest that this application for Sanitary Sewer System to Serve Timber Ridge Industrial Park, Phase 7 has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 ell as civil penalties up to $25,000 per violation. 1a. G 4/0( �r C. Signing Official Signature Date Z 0 H Q V LL H ' Ce V„j 0 Cl 2. Professional Engine s ertification: ! attest that this a placation for Sanitary Sewer System to Serve Timber Ridge Industrial Park, Phase 7 has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that l have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. . 0,„ iC.f4tpl II t�,ry,, 2a. Mr_ Dan Brewer ' ��1 CAilt-; ��'%, ���''' Professional Engineer Namet. 2b. Chas. H Sells, Inc. a : O."- '�e _ r _ a Engineering Firm L _ 2c 128 Overhill Drive, Suite 105 ; 17582 `^ g 'I q .�` � Address a1. 1Q'a4.,FNOI1,1 �`� .� ff 2d. Mooresville 12e. NC 2f. 28117 '�•,,,, �. gi+y, City I State [_......_. Zip..- _--- -- 704-662-0100 2h. 704-662-0101 2i. dbrewer@chashsells.comS `�.�� ��•0/Nisi, t 4''''''`„2g. Telephone 1 Facsimile E-mail Seal, Signature & Date _f FTA 02/03 Permit Number WQ0030774 Central Files: APS SWP 09/12/06 Permit Tracking Slip Program Category Status Project Type Non -discharge In review New Project Permit Type _ Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer A Individual Extensions Primary Reviewer Permit Contact Affiliation marcia.allocco Permitted Flow 8750 Facility Facility Name Timber Ridge Expansion Location Address Owner Major/Minos Region Minor Mooresville County Iredell Facility Contact Affiliation Owner Name Owner Type Town of Mooresville Government - Municipal Owner Affiliation James Justice, Manager Town PO Box 878 Mooresville Dates/Events NC 281150878 Orig Issue App Received 09/05/06 Draft Initiated Scheduled Issuance Public Notice Issue Effective Expiration Regulated Activities ReauestedlReceived Events Commercial or industrial, other Additional information requested Wastewater collection Additional information received Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin Consul nngin er ,Surveyors& hoto rarer e wa; NCDEN'R, Division of. 'Water )u tlit 610 E. Center Ave. M©oresvi11e, NC' 281 15 SEP P Reference: Application fortlic Sanitary Sewer Extension To Serve Timber Ridge Expansion Mooresville, North Carolina. Ladies and Gentlemen: DAN E BREWER. RE. C j; ,iAtiSEY A ,t Ao K E3F;4�ci�' �nER, F i. S On behalf of the. 'Town of Moor%sville, i lease find enclosed one ore copy of the hast- Track Application 'for Gravity Sewers, Pump Stations, and Force Mains fear the above referenced project. Also included is a check in the amount of,S400 for the permit processing fee. In summary, the project con commercial business park loca guidelines a flow rate of 8,750 CPI) is es 8-inch diameter sanitary sewer extension to serve a. Road in Mooresville, NC. Based upon the NC'DENR. .ated fo.r the project. If you have any questions or require additional infonmation, please convict us. Respectfully submitted,. Chas. H. Sells, Inc. Donna H.. Barbour, P.E. Project Engineer II Cc: Mr, Richard Skrfk Southern C:onstruc ITC)