Loading...
HomeMy WebLinkAbout20060659 Ver 4_Stormwater Info_20130701WITHERS & RAVENEL ENGINEERS I PLANNERS I SURVEYORS 14110 COMMONWEALTH DRIVE, SUITE toi WILMINGTON, NORTH CAROLINA, 28403 (910) 256 -9277 FAX (910) 256 -2584 TO: NC Division of Water Quality — 4o1 Wetlands Unit 165o Mail Service Center Raleigh, NC 27699 WE ARE SENDING YOU ❑ Shop Drawings ❑ Copy of Letter ® Attached ❑ Prints ❑ Change order LETTER C-F TRANS YTAL DATE 6/28/13 1 JOB NO. 020 0018.00 ATTENTION Karen Higgins PHONE i gig-807-636o RE: Woods at Umstead (DWQ Pro' #o6-o659) V Buffer Authorization Modification PCN 020 0018.00 Buffer Modification PCN 1 6/26/13 020 ool8.00 ❑ Under separate cover via ❑ Plans ❑ Samples ❑ Diskette ❑ the following items: ❑ Specifications COPIES DATE NO. DESCRIPTION 6/26/13 020 0018.00 Buffer Modification PCN 1 6/26/13 020 ool8.00 CD of PCN THESE ARE TRANSMITTED as checked below: ® For approval ❑ Approved as submitted ❑ For your use ❑ Approved as noted ❑ As requested ❑ Returned for corrections ❑ For review and comment ❑ ❑ FOR BIDS DUE 20 ❑ PRINTS RETURNED AFTER LOAN TO US ❑ Resubmit ❑ Submit ❑ Return _ copies for approval copies for distribution corrected prints REMARKS: COPYTO: File SIGNED: Troy Beasley lfenclosures are not as noted, kindly notify us at once. STORMWATER MANAGEMENT PERMIT APPLICATION FORM 401 CERTIFICATION APPLICATION FORM EVEL SPREADER - VEGETATED FILTER STRIP (LS-VFS) SUPPLEMENT This form must be completely filled out, printed, initialed, and submitted, Project name Contact name Phone number at The purpose of the LS-VFS Stormwater enters LS-VFS from Type of VFS Explanation of any "Other" responses above 39,640 fe 21,344 fe 53.85 % 0.57 0.52 Cie 5.00 min 7.22 in/hr 3.75 cfs 1 inchihour storm 0.52 cfs Y (Y or N) Do not complete this section of the form. cfs cfs Do not complete this section of the form. 2 cfs cfs Do not complete this section of the form. (Y or N) Form SW401 - LS-VFS - 27Ju12011 - Rev.9 page 1 of 3 Slope (from level lip to the end of the VFS) Are any draws present in the VFS? Is there a collector swale at the end of the VFS? Bypass System Design (if applicable) Is a bypass system provided? Is there an engineered flow splitting device? Dimensions of the channel (see diagram below): M 6A3 % N ! (Y or N) N (Y or N) Mill Y (Y or N) Y (Y or N) Please provide plan details of flow splitter & supporting caics. W s. 1 Liz R •` EDIT Please 1 1. • or plan be where the supporting do o be found. An incomplete / package request result in a r..: additional infi i will delay final review and approval of project. p.... -. provided 1 indicate following desi requirements been applicant has designated an agent, agent may initial below. 'r o been met, attach justification. 2. Plan details (11' = 30'or larger) for the level spreader showing: F.. Y.. . 1 applicable), High flow bypass Proposed drainage easement, and �',• /i li/ i•,,, / ..1. it Y 1: '. Design build-out. Form SW401 - LS -VFS - 27Ju12011 - Rev .9 page 2 of 3 1 Section view of the level spreader (1" = 29 or larger ) ; showing: Underarm system pf applicable), Levei lip: Upslope channel, and dwnslope flIter fabric: 4, Plan details of the flow splitting device and supporting calculations tit applic bief 5, A construction sequence that shows how the level spreader will be protected from sediment until the entire drainage area is stabilized. 5. If a non - engineered VFS is being used, then provide a photograph of the VFS shoving that no draws are present; 7, The supporting calculations, t� :tweet 12 - BMP Plan Sheet 12 - BMP Plan Sheet 1 - OMP Plan Nattached attached Form SW401 - LS-VF - 27Jul Gl t - Rev 9 page 3 Of 3` Woods @ Umstead - FES 30 Bypass Channel Friction Method Manning Formula Solve For Normal Depth Roughness Coefficient 0.069 Infinity ft/s Infinity ft/s Channel Slope 0.06000 ftlift ft 0.06000 ft/ft Left Side Slope 100 ft/ft (H:V) Right Side Slope 3.00 ft/ft (H:V) Discharge 3.74 ft3/s Normal Depth 0.70 ft Flow Area 1,48 ft2 T= cit S Wetted Perimeter 4.44 ft Hydraulic Radius 0.33 ft Top Width 4.21 ft Critical Depth Critical Slope 0l63 0.10958 ft ft/ft J00 l tvw g.uu Velocity 2l53 ft/s Velocity Head 0.10 ft Ov, Zap Specific Energy 0.80 ft UJI 0(60 P 10 Froude Number 0.75 Flow Type Subcritical . ength 0 Number Of Steps_ 0.00 ft 0.00 ft 0 a- ill ill lml ill 1!11 mill I'lls ill 1 11 0.00 ft Infinity ft/s Infinity ft/s 0.70 ft 0.63 ft 0.06000 ft/ft 0.10958 ft/ft Bentley Systems, Inc. Hassled Methods Sol lilklatMaster V8i (SELECTserles 1) [08.11.01.031 6/2612013 10:26:01 AM 27 Slemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 EM 5 1 no, 61 IT, MM 15 R X in N FiTel a IT, I a IL 1111; :14LQ It If Stormwater Enters the LS-VFS from the Drainage Area Drainage area Impervious surface area Percent impervious Rational C coefficient Peak flow from the 1 in/hr storm Time of concentration Rainfall intensity, 1 0-yr storm Peak flow from the 1 0-yr storm Tesign storm Is a flow bypass system going to be used? Explanation of any "Other" responses above 28,750 fit' 12,937 fe 4&00 % 038 fucfs 025 cfs HO min 722 in/hr 131 cis 1 inch/hourstorm 025 cfs Y (Y or N) Do not complete this section of the form. cfs cfs Do not complete this section of the form, 2 cfs cfs Do not complete this section of the form, (Y or N) 36 so ft 6 in 6 in 50 fucfs 13 ft 17 it 65 ft 313.50 fmsl Form SW401 - LS-VFS - 27Ju12011 - Rev .9 page 1 of 3 Slope (from level lip to the end of the VFS) Are any draws present in the VFS? Is there a collector swale at the end of the VFS? Bypass System Design (if applicable) Is a bypass system provided? Is there an engineered flow splitting device? y (flow depth for 1 0-year storm) freeboard (during the 1 0-year storm) Channel lining material Jo es the bypass discharge through a wetland? Mr es the channel enter the stream at an angle?— 9 no M = E 3 2 UO T-Tarm -T • —IM N M. -T—M 6.92 % N (Y or N) OK N (Y or N) Y (Y or N) Y (Y or N) Please provide plan details of flow splifter & supporting talcs. 1,00 ft UO ft MO ft 0.54 ft 1.04 ft 2.09 fUsec Pick one: N (Y or N) Y (Y or N) W it i... i off I U." - Boundaries of drainage easement. Forebay (if applicable), High flow bypass system, # -'P-1* *W* A m 1-4 R # W Proposed drainage easement, and Design at ultimate build-out. 12DI in I Page or plan sheet number and any notes: — Sheet 1- Site Plan, Sheet 3 - Grading Plan Sheet 12 - BMP Plan Form SW401 - LS-VFS - 27M2011 - Rev.9 page 2 of 3 3. Section view of the level spreader (1' = 29 or larger) showing: - Underdrain system (if applicable), Level lip, Upslope channel, and Downsippe filter fabift XD� Sheet 12 - BMP Plan Sheet 12 - BMP Plan 5. A construction sequence that shows how the level spreader will be protected from I-k-DSfteet 12 - BMP Plan sediment until the entire drainage area is stabilized, 6. If a non-engineered VF S is being, used, than provide a photograph of the VFS showing that no draws are present, 7. The supportimlcaiGulabons, 8, A copy of the signed and notarized operation and maintenance (Q&M) agreement. le�L attached attached Form SW401 - LS-VFS - 27JW2011 - Rev.9 page 3 of 3 Bentley Systems, Inc. Haestad Methods Sol BklafJdpeVkwMaster V8i (SELECTseries 1) [08.11.01.03] 6/2512013 10:28:47 AM 27 Slemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 Woods @ Umstead - FES 40 ftpass Channel . .. . ... ... .. 01 AL ......'imp"wi 5 .0h A . ...... . . ...... F' V . . . . .4 .. .0 .... . ...... . . .... xF .. .... Friction Method Manning Formula Solve For Normal Depth .. ........... ...... . ..... ...... ....... .... . . 411". .. V . . .. . .. ..... . . . .... ... . . ........ . - . . . . ..... .. ... . . . ..... . . . . .... AX. . ..... R41 . . . ...... . . . . . . . . ...... . ... Roughness Coefficient 0.069 Channel Slope 0.05830 ft/ft Left Side Slope 3.00 ft/ft (H:V) Right Side Slope 3.00 ft/ft (H:V) Discharge 1.81 ft3/s .... ... .. . ... .. . .... .. .... . .. ...... .. ... . .... ... . . . ........ .. . .... . ... .. .. .. ... . .. .... .... . . ... .. .. . ... .. ... . . . .. .. . .. . . . - . .... . .. ..... .. Normal Depth Flow Area 0.54 0.87 ft ft2 Wetted Perimeter 3.40 ft 4'( Hydraulic Radius 0.25 ft (42. Top Width 3.22 ft 07 Critical Depth Critical Slope 0.47 0.12071 ft ft/ft 17 NW) (0 Velocity 2.09 ft/s Velocity Head 0.07 fl: use, e%p aip Specific Energy Froude Number 0.61 0:71 ft c2j Flow Type Suberitical .... . .. ... .. ... . ...... .. ......... ...... . . . . .. . ........... . ... ........ .. . ..... . . . .. . . .. . . . .. . . .. .. . . . . . . . .- . .. . . . .... .. ... . ... .. ... .. .. .... .... . ...... ....... .. . . .. ... ...... .... . .. .... ... Downstream Depth 0.00 ft Length 0.00 ft Number Of Steps 0 .. ..... .. . 0-0 . . ..... ...... .. .. . .. . ...... Y . ...... .... . . .. .... ... . .. . ... .... . . . .... . . .. . . . . . . ..... . ... ... . Upstream Depth 0.00 ft Profile Description Profile Headloss 0.00 ft Downstream Velocity Infinity ft/s Upstream Velocity Infinity ft/s Normal Depth 0.54 ft Critical Depth 0.47 ft Channel Slope 0.05830 fUft Critical Slope 0.12071 ft/ft Bentley Systems, Inc. Haestad Methods Sol BklafJdpeVkwMaster V8i (SELECTseries 1) [08.11.01.03] 6/2512013 10:28:47 AM 27 Slemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 Page 1 of 1 -PR . .... N CT I,..... sq ft Project name The Woods at Umstead Contact name Hunter Freeman Phone number 919-469-3340 Date January 12, 2012 Drainage area number it Ill. 011 INFO..... ATIQfti The purpose of the LS-VFS Buffer Rule: Diffuse Flow Stormwater enters LS-VFS from A BMP Type of VFS Engineered filter strip (graded & sodded, slope < 8%) Explanation of any "Other" responses above If Stormwater Enters the LS-VFS from the Drainage Area Drainage area Impervious surface area Percent impervious Rational C coefficient Peak flow from the 1 in/hr storm Time of concentration Rainfall intensity, 1 0-yr storm Peak flow from the 1 0-yr storm Design storm Maximum amount of flow directed to the LS-VFS Is a flow bypass system going to be used? Explanation of any "Other" responses above Explanation of any "Other" responses above LS-VFS Design Forebay surface area Depth of forebay at stormwater entry point Depth of forebay at stormwater exit point Feet of level lip needed per cis Computed minimum length of the level lip needed Length of level lip provided ft- ft� cis min in/hr CIS Do not complete this section of the form. Do not complete this section of the form. Do not complete this section of the form. Do not complete this section of the form. Do not complete this section of the form, Do not complete this section of the form. Do not complete this section of the form. Do not complete this section of the form. cfS Do not complete this section of the form. (Y or N) Do not complete this section of the form, M 0 sq ft In 10 fUcfS 2 ft 10 it Too shallow, Ten feet is the minimum level spreader length, Form SW401 - LS-VFS - 27Jul2011 - Rev,9 page 1 of 3 Width of VFS Elevation at downslope base of level lip Elevation at the end of the VFS that is farthest from the LS Slope (from level lip to the end of the VFS) Are any draws present in the VFS? Is there a collector swale at the end of the VFS? Bypass System Design (if applicable) Is a bypass system provided? Is there an engineered flow splitting device? y (flow depth for 1 0-year storm) freeboard (during the 1 0-year storm) Channel lining material Does the bypass discharge through a wetland? Does the channel enter the stream atan angle? 30 It 341,00 fmsl $40.00 fmsI 333 % N (Y or N) OK N (Y or N) Y (Y or N) Y (Y or N) Please provide plan details of flow splitter & supporting calGs. 100 ft 0,00 ft 12,00 ft 0.65 ft 1,35 ft 439 fl/sec Pick one: N (Y or N� Y (Y or N) 0 ROM in a request for additional information. This will delay final review and approval of the project. Initial in the space provided to indicate the following design requirements have been met. If the applicant has designated an agent, the agent may initial below. If a requirement has not been met, attach justification. haffi* Page or plan sheet number and any notes* Form SW401 - LS-VFS - 27M2011 - Rev.9 page 2 of 3 2. Plan details (1 ' = 30' or larger) for the level spreader showing: - Forebay (if applicable), High flow bypass system, Proposed drainage easement, and Design at ultimate build-out. 3. Section view of the level spreader (1 "= 20' or larger) showing: - Underdrain system (if applicable), Level lip, Upslope channel, and Downslope filter fabric. 4. Plan details of the flow splitting device and supporting calculations (if applicable). 5. A construction sequence that shows how the level spreader will be protected from sediment until the entire drainage area is stabilized. & If a non-engineered VFS is being used, then provide a photograph of the VFS showing that no draws are present. 7. The supporting calculations. Form SW401 - LS-VFS - 27M2011 - Rev,9 page 3 of 3 Input DOW R7Channel Slope Left Side Slope ightSide s It Normal Depth Flow Area Wetted Perimeter Top Width Critical Depth Critical Slope Velocity Velocity Head Specific Energy Froudn Number Flow Type 6,646 it 6.67606 Wit- 100 ft/ft (H:V) Profile Hesdloss 0.00 6,00 ft'Os 6:66 it it Profile Description 1,26 ftz Profile Hesdloss 0.00 4.13 ft- Infinity e 3.92 it fti Normal Depth 016 it $ OJ6 {iM4 6 ft /ft 0,07600 faft 4,69 his e 034 ft# 0.69 it 1 ,46 Downstream Depth 6.60 it Length 0.04 it Number Of Steps 6° Upstream Depth 0,00 it Profile Description Profile Hesdloss 0.00 it Downstream Velocity ity Infinity it/$ Upstream Velocity infinity fti Normal Depth 6,66 it Critical Depth OJ6 ft Channel Slope 0,07600 faft Critical Slope 0.03458 fVfft z 1111plipill w m m m mr Append! Table 8.05g Permissible Unit Shear Stress, T d Permissible Shear Stresses for Rprap and Tempoary i r Lining Category Lining Type (lb/ft2) Liners Temporary Woven Paper Net 0.15 Jute Net 0.45 Fiberglass Roving: Single 0.60 Double 0.85 Straw with Net 1.45 Curled Wood mat 1.55 Synthetic at 2.00 d 50 Stone Size (inches) Gravel, Riprap 1 0.33 2 0.67 Rock Riprap 6 2.00 9 3.0 21 7.8 24 &00 Adapted From: FHWA, HEC- 15, April 1983, pgs. 17 & 37, Design Procedure- The following is a step-by-step procedure for designing a temporary liner for Temporary Liners a channel. Because temporary liners have a short period of service, the design Q may be reduced. For liners that are needed for six months or less, the 2-year frequency storm is recommended. Step 1. Select a liner material suitable for site conditions and application. Determine roughness coefficient from manufacturer's specifications or Table 8.05e, page 8.05.10. Step 2. Calculate the normal flow depth using Manning's equation (Figure 8.05d). Check to see that depth is consistent with that assumed for selection of Manning's n in Figure 9.05d, page 8.05.11. For smaller runoffs Figure 8.05d is not as clearly defined. Recommended solutions can be determined by using the Manning equation. Step 3. Calculate shear stress at normal depth. Step 4. Compare computed shear stress with the permissible shear stress for the liner. Step 5. If computed shear is greater than permissible shear, adjust channel dimensions to reduce shear, or select a more resistant lining and repeat steps I through 4. Design of a channel with temporary lining is illustrated in Sample Problem 8.05b, page 8.05.14. Rev. 12/93 8.05.13 Permit (to be provided by D WQ) Drainage Area Number: Filter Strip, Restored Riparian Buffer and Level Spreader Operation and Maintenance Agreement I will keep a maintenance record on this BMP. This maintenance record will be kept in a log in a known set location. Any deficient BMP elements noted in the inspection will be corrected, repaired or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, and the removal efficiency of the BMP. Important maintenance procedures: - Immediately after the filter strip is established, any newly planted vegetation will be watered twice weekly if needed until the plants become established (commonly six weeks). - Once a year, the filter strip will be reseeded to maintain a dense growth of vegetation - Stable groundcover will be maintained in the drainage area to reduce the sediment load to the vegetation. After the filter strip is established, it will be inspected quarterly and within 24 hours after every storin event greater than 1.0 inch (or 1.5 inches if in a Coastal County). Records of operation and maintenance will be kept in a known set location and will b,4 available upon request. Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately. Form SWU401-Level Spreader, Filter Strip, Restored Riparian Buffer O&M-Rev.3 Page I of 3 BNO element: Poten!!,al noble ow I will remSqfate the noble� The swale and the Level The swale is clogged with Remove the sediment and dispose lip sediment. of it off -site. The level lip is cracked, Repair or replace lip. settled, undercut, eroded or otherwise damaged. ere is erosion around the Regrade the soil to create a berm end of the level spreader that that is higher than the level lip, and shows stormwater has then plant a ground cover and bypassed it. water until it is established. Provide lime and a one-time fertilizer application. Trees or shrubs have begun Remove them. to grow on the swale or just downslope of the level lip. The bypass channel Areas of bare soil and/or Regrade the soil if necessary to erosive gullies have formed. remove the gully, and then reestablis h roper erosion control. Turf reinforcement is Study the site to see if a larger damaged or ripap is rolling bypass channel is needed (enlarge if downhill. necessary). After this, reestablish the erosion control material. The filter strip Grass is too short or too long Maintain grass at a height of (if a2pli able% c a roximatelv three to six inches Areas of bare soil arid/or Regrade the soil if necessary to erosive gullies have formed. remove the gully, and then plant a ground cover and water until it is established. Provide lime and a one-time fertilizer application. Sediment is building up on Remove the sediment and the filter strip. restabilize the soil with vegetation if necessary. Provide lime and a one- time fertilizer a lication. Plants are desiccated. Provide additional irrigation and fertilizer as needed. Plants are dead, diseased or Determine the source of the dying. problem: soils, hydrology, disease, etc. Remedy the problem and replace plants. Provide a one-time fertilizer application. Nuisance vegetation is Remove vegetation by hand if choking out desirable species. possible. If pesticide is used, do not allow it to get into the receiving water. The receiving water Erosion or other signs of Contact the NC Division of Water damage have occurred at the Quality local Regional Office, or the outlet, 401 Oversight Unit at 919-733-1786. Form SWU401-Level Spreader, Filter Strip, Restored Riparian Buffer O&M-Rev.3 Page 2 of 3 Permit Number: (to be provided by D WQ) I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. .............................................. BMP drainage area number:1 MMMMM!�Mamm=- � 1911 MMMEM3i�� MMM My commission expires Form SWU40 I -Level Spreader, Filter Strip, Restored Riparian Buffer O&M-Rev.3 Page 3 of 3 Permit Number: (to be provided by D WQ) Drainage Area Number,_ Filter Strip, Restored Riparian Buffer and Level Spreader Operation and Maintenance Agreement I will keep a maintenance record • this BMP. This maintenance record will be kept in a log in a known set location. Any deficient BMP elements noted in the inspection will be corrected, repaired or replaced immediately. These deficiencies can affect the integrity of structures, safety • the public, and the removal efficiency of the BMP. Important maintenance procedures: — Immediately after the filter strip is established, any newly planted vegetation will ■ watered twice weekly if needed until the plants become established (commonly six weeks). — Once a year, the filter strip will be reseeded to maintain a dense growth of vegetation — Stable groundcover will be maintained in the drainage area to reduce the sediment load to the vegetation. After the filter strip is established, it will be inspected quarterly and within 24 hours after every storm event greater than 1.0 inch (or 1.5 inches if in a Coastal County). '*%row known set location and will be available upon request. Inspection activities shall be performed as follows. Any problems that are found shall be repaired immediately. Form SWU40 I -Level Spreader, Filter Strip, Restored Riparian Buffer O&M-Rev.3 Page I of 3 BMP element: Potential problem: How I will remediate the ,prole: The swale and the level The swale is clogged with Remove the sediment and dispose lip sediment. of it off-site. The level lip is cracked, Repair or replace lip. settled, undercut, eroded or otherwise dama ed. There is erosion around the Regrade the soil to create a berm end of the level spreader that that is higher than the level lip, and shows stormwater has then plant a ground cover and bypassed it. water until it is established. Provide lime and a one-time fertilizer application. Trees or shrubs have begun Remove them. to grow on the swale or just downslope of the level 1i p. The bypass channel Areas of bare soil and/or Regrade the soil if necessary to erosive gullies have formed. remove the gully, and then reestablish proper erosion control. Turf reinforcement is Study the site to see if a larger damaged or ripap is rolling bypass channel is needed (enlarge if downhill. necessary). After this, reestablish the erosion control material. The filter strip Grass is too short or too long Maintain grass at a height of if applicable) . apj2roximate!y three to six inches. .................................................... Areas of bare soil and/or Regrade the soil if necessary to erosive gullies have formed. remove the gully, and then plant a ground cover and water until it is established. Provide lime and a one-time fertilizer application. Sediment is building up on Remove the sediment and the filter strip. restabilize the soil with vegetation if necessary. Provide lime and a one- time fertilizer application. Plants are desiccated. Provide additional irrigation and fertilizer as needed. Plants are dead, diseased or Determine the source of the dying. problem: soils, hydrology, disease, etc. Remedy the problem and replace plants. Provide a one-time fertilizer application. Nuisance vegetation is Remove vegetation by hand if choking out desirable species. possible. If pesticide is used, do not allow it to get into the receiving water. The receiving water Erosion or other signs of Contact the NC Division of Water damage have occurred at the Quality local Regional Office, or the outlet. 401 Oversight Unit at 919-733-1786. I �i 1 11 1111116 11 11111 k 1111 111 Permit Number: (to be provided by D WQ) I acknowledge and agree by my signature below that I am responsible for the performance ♦ the maintenance procedures listed above. I agree to notify E of any [♦ roblems with the system or prior to any changes to the system or responsible party. Projecl nameffhe Woods at Umstead Phase 2 BMP drainage area number:2 from FES#30 Print name -.Julian W. Raw] Title-,Mana ger ............... Address: 100 Weston Estates M�gy Cary NC 27513 Note: The legally responsible party should not be a homeowners association unless more than 50% the lots have been sold and a resident of the subdivision has been named the presiden 1'. nL,C- a Notary Public for the State of LI _,- County o do hereby certify that LA_ar.0 - SEAL My commission expires M so S 0 V N ° 011, 41"'N� SEAL My commission expires Permit Number: (to be provided by D WQ) Drainage Area Number:_ Filter Strip, Restored Riparian Buffer and Level Spreader Operation and Maintenance Agreement I will keep a maintenance record on this BMP. This maintenance record vs7i-1 be kept in a log in a known set location. Any deficient BMP elements noted in the inspection will be corrected, repaired or replaced immediately. These deficiencies can affect the integrity of structures, safety of the public, and the removal efficiency of the BMP. Important maintenance procedures: — Immediately after the filter strip is established, any newly planted vegetation will be watered twice weekly if needed until the plants become established (commonly six weeks). — Once a year, the filter strip will be reseeded to maintain a dense growth of vegetation — Stable groundcover will be maintained in the drainage area to reduce the sediment load to the vegetation. After the filter strip is established, it will be inspected quarterly and within 24 hours zfter every storm event greater than 1.0 inch (or 1.5 inches if in a Co o astal Cunty). Records • operation and maintenance will be kept in a known set location and wi 13, available upon request. Inspection activities shall be performed as follows. A-ny problems that are found shall be repaired immediately. Form SWU40 I -Level Spreader, Filter Strip, Restored Riparian Buffer O&M-Rev.3 Page I of 3 BMP element: Potential problem: How I will re mediate theIe�nr The swale and the level The swale is clogged with Remove the sediment and dispose lip sediment. of it off-site. The level lip is cracked, Repair or replace lip. settled, undercut, eroded or otherwise damaged. There is erosion around the Regrade the soil to create a berm end of the level spreader that that is higher than the level lip, and shows stormwater has then plant a ground cover and bypassed it. water until it is established. Provide lime and a one-time fertilizer application. Trees or shrubs have begun Remove them. to grow on the sale or just downslope of the level H2. The bypass channel Areas of bare soil and/or Regrade the soil if necessary to erosive gullies have formed. remove the gully, and then reestablish erosion control. Turf reinforcement is ,proper Study the site to see if a larger damaged or ripap is rolling bypass channel is needed (enlarge if downhill. necessary). After this, reestablish the erosion control material. The filter strip Grass is too short or too long Maintain grass at a height of if applicable) . arproximate!y three to six inches. ................................... Areas of bare soil and/or Regrade the soil if necessary to erosive gullies have formed. remove the gully, and then plant a ground cover and water until it is established. Provide lime and a one-time fertilizer application. Sediment is building up on Remove the sediment and the filter strip. restabilize the soil with vegetation if necessary. Provide lime and a one- time fertilizer a lication. Plants are desiccated. Provide additional irrigation and fertilizer as needed. Plants are dead, diseased or Determine the source of the dying. problem: soils, hydrology, disease, etc. Remedy the problem and replace plants. Provide a one-time fertilizer application. Nuisance vegetation is Remove vegetation by hand if choking out desirable species. possible. If pesticide is used, do not allow it to get into the receiving water. The receiving water Erosion or other signs of Contact the NC Division of Water damage have occurred at the Quality local Regional Office, or the outlet. 401 Oversight Unit at 919-733-1786. �i IN Permit Number: (to be provided by D WQ) I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. BMP drainage area number-3 from FES#40 Print nameJulian W. Rawl Title:.Manager Address: 100 Weston Estates Way, Cary C27513 Note: The legally responsible party should not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the president, a Notary Public for the State of &� l unty of _4 day of — VICr Strit). riparian I - r strip, riparian buffer, an( Witness my hand and official seal, C n My commission expires �- — a �- � �s � ter.. � Y m J a N M N N m 3 0 a Im 3 cV 0 ° 0 a 0 i 0 c� N m 0 a m E 0 x m 0 i 0 0 I 0 0 Y TRANSPORTATION NOTES 1. DOUBLE WHEELCHAIR RAMPS ARE TO BE INSTALLED AT ALL PUBLIC STREET INTERSECTIONS WHERE SIDEWALK IS REQUIRED. WHEN . SIDEWALK IS NOT REQUIRED, CURB IS TO BE DEPRESSED AT ALL RAMP LOCATIONS AS SHOWN ON THIS STREET. 2. THE MINIMUM CORNER CLEARANCE FROM THE CURB LINE OR EDGE OF PAVEMENT OF INTERSECTING STREETS SHALL BE AT LEAST TWENTY (20) FEET FROM THE POINT OF TANGENCY OF THE RADIUS CURVATURE, OR TWENTY (20) FEET FROM THE INTERSECTION OF RIGHT -OF -WAY LINES, WHICHEVER IS GREATER. THE RADIUS OF THE DRIVEWAY SHALL NOT ENCROACH ON THE MINIMUM CORNER CLEARANCE. 3. WITHIN THE AREA OF A DEFINED SIGHT TRIANGLE, THERE SHALL BE NO SIGHT OBSTRUCTING OR PARTLY OBSTRUCTING WALL, FENCE, SIGN, FOLIAGE, BERMING OR PARKED VEHICLES BETWEEN HEIGHTS OF TWENTY -FOUR (24) INCHES AND EIGHT (8) FEET ABOVE THE CURB LINE ELEVATION OR THE NEAREST TRAVELED WAY IF NO CURBING EXISTS. 4. ALL CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH CITY OF RALEIGH AND /OR NCDOT STANDARDS AND SPECIFICATIONS. N \F KENNETH GARRARD PIN# 0775 -76 -3025 NOTE LOTS 1 -8 WILL HAVE NO DIRECT ACCESS ONTO TRENTON ROAD. NOTE ALL EXISTING STRUCTURES ON SITE SHALL BE DEMOLISHED PRIOR TO LOT RECORDATION. NOTE ALL 26' B -B STREETS SHALL POST "NO PARKING" SIGNAGE ON ONE SIDE OF STREET TO ENSURE 20' CLEAR WIDTH FOR EMERGENCY VEHICLES. SUMMARY INFORMATION DEVELOPMENT NAME: LOCATION: PROPOSED USE: CURRENT USE: INSIDE CITY LIMITS: INSIDE FALLS LAKE: INSIDE FLOOD HAZARD BOUNDARY: WAKE COUNTY PIN #: ZONING DISTRICT: DISTANCE TO UMSTEAD PARK: PARCEL SIZE: TOTAL ACRES OPEN SPACE ACRES REQUIRED: TOTAL OPEN SPACE ACRES PROVIDED: TOTAL ACRES OF RESIDENTIAL STREET R /W: TOTAL ACRES OF THOROUGHFARE R /W: LINEAR FEET IN PUBLIC STREETS: NO OF UNITS ALLOWED: NO OF UNITS PROPOSED: NO OF OPEN SPACE LOTS PROPOSED: MINIMUM LOT SIZE (R -2 MPOD): MINIMUM LOT SIZE (R -4): AVERAGE LOT SIZE: GENERAL NOTES THE WOODS AT UMSTEAD 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT CITY OF TRENTON ROAD AND TRINITY FARMS ROAD CHORD RALEIGH STANDARD SPECIFICATIONS. SINGLE- FAMILY RESIDENTIAL 2. ALL CURB TURNOUT RADII SHALL BE 30 FEET UNLESS OTHERWISE SPECIFIED VACANT S2429'02 "W ON THE PLANS. YES 500.00 33.44 NO 3. THE INTERSECTION OF RIGHTS -OF -WAY SHALL BE ROUNDED WITH A RADIUS NO 41.40 OF 25 FEET UNLESS OTHERWISE SPECIFIED ON THE PLANS. 0775.02 -75 -5892 (R- 2- MPOD), 0775.02 -75 -5370 (R -4 CUD) 114.93 150.00 0775.02 -75 -1253 (R -4 CUD), 0775.16 -94 -0819 (R -4 CUD) 4. THE CONTRACTOR SHALL CLEAR AND GRADE THE ENTIRE RIGHT -OF -WAY R -4 CUD, R -2 MPOD L110 WIDTH WITHIN 100 FEET OF ALL STREET INTERSECTIONS. 1,650 FT. 5. ALL INTERNAL SIGHT TRIANGLES SHOWN ARE 15' X 250'. THE CONTRACTOR S58'1 8'2e'E L112 SHALL CLEAR AND GRADE AS NECESSARY TO PROVIDE 15' X 250' SIGHT 32.99 AC. S67'44'02 "E DISTANCE TRIANGLES AND ALL INTERNAL SUBDIVISION STREET INTERSECTIONS. 0 AC. S49'04'31 "E L13 1.65 AC. (PHASE 1) 6. HOMEOWNERS DOCUMENTS SHALL BE PROVIDED WITHIN 14 DAYS OF LOT 49.57 S01' 15' 10 "E RECORDATION. 2.61 AC (PHASE 1) AND X AC (PHASE 2) 7. FEMA FLOODPLAIN SHOWN ON THIS SITE PER FIRM MAP 3720077500J, PANEL 0.15 AC. (PHASE 1) S86'13'52 "E 0775 DATED MAY 2, 2006. 1,674 L.F. (PHASE 1) AND 506 L.F. (PHASE 2) S17'28'51 "W L18 60.69 8. MAXIMUM BUILDING HEIGHT IN MPOD WILL BE 21 STORIES, PER MPOD 128 S17'45'01 "W REGULATIONS. MPOD APPLIES ONLY TO LOTS 1, 19 AND 20. 26 (PHASE 1) AND 9 (PHASE 2) S1857'17"W L21 1 (PHASE 1) 9. THE MINIMUM CORNER CLEARANCE FROM THE CURB LINE OF INTERSECTING 29,187 SF S23'25'08 "W STREETS SHALL BE AT LEAST 20 FEET FROM THE POINT OF TANGENCY. NO 15,839 SF S25'12'51"W DRIVEWAYS OR PARKING SPACES SHALL ENCROACH ON THIS MINIMUM 37,603 SF S26'52'33 "W CORNER CLEARANCE. d / N \F 10. NO SIGHT- OBSTRUCTING OR PARTIALLY OBSTRUCTING WALL, FENCE, MARY T. GOODEN SETBACKS: FOLIAGE, BERM, PARKED VEHICLES, SIGN OR OTHER OBJECTS BETWEEN THE AND FRONT YARD: 20 HEIGHTS OF TWO (2) FEET AND EIGHT (8) FEET ABOVE THE CURB LINE 5' R/W / SIDNEY S. THAMES REAR YARDS: 30 DEDICATION FOR Ury� j DB 9369 \PG 2690 SIDE YARD: 10 ELEVATION SHALL BE PLACED WITHIN A SIGHT TRIANGLE. TRENTON ROAD - BM 1978 \PG 622 CORNER SIDE YARD: 20 s PIN# 0775.02 -75 -5892 pp� ZONED: R -2 MPOD MPOD CALCULATIONS 2.01 ACRES LOTS 1, 19 & 20 MAXIMUM IMPERVIOUS AREA: 30% OF LOT AREA. LOTS 1 & 19 TRENTON FARMS 30' PROPOSED i � MAY BE INCREASED TO 60% IMPERVIOUS IF TREES WITHIN 30' NATURAL SUBDIVISION NATURAL PROTECTIVE ti ���, PROTECTIVE YARD IMPACTED BY CONSTRUCTION ACTIVITY ARE INVENTORIED AND YARD 1 4, REPLACED AT THE SCHEDULE SET FORTH IN 10- 2053(E)(4). LOT 20 MAXIMUM 25 IMPERVIOUS AREA MAY BE INCREASED TO 60% WITHOUT ANY ADDITIONAL ' 20' CITY �\ °` �54s., REQUIREMENTS BY THE CITY. IF TREES WITHIN 30 NATURAL PROTECTIVE YARD OF RALEIGH 1 ` `� �'•� � WILL BE IMPACTED ON LOTS 1 OR 19, REPORT MUST ALSO BE PROVIDED TO THE SEWER 1 \ //- , CITY INDICATING WHICH TREES ARE TO BE REMOVED OR IMPACTED AND \ EASEMENT--I `��� 19 �� o�, EXPLAINING WHY SUCH TREES HAVE TO BE REMOVED AND WHY SUCH GRADING 1 1 , MUST OCCUR NEAR THE TREES. 31,612 SF 29,281 SF \1 FIp j a ; QO PRIVATE EASEMENT STORM / ` _ PLAT NOTES 61 \\ \ vv ` ` 1. PLAT FOR THE WOODS AT UMSTEAD RECORDED IN WAKE COUNTY REGISTER TRENTO ARMS oq Fq �\ � N \F OF DEEDS (BM 2008, PG 2150) INCLUDING PREVIOUSLY APPROVED PRIVATE RM`� rws JOHN D. COLVARD DRAINAGE AND CITY OF RALEIGH SANITARY SEWER EASEMENTS SUBDI ION „` o I 20 �� SABRINA S. COLVARD �; / \ t 2x,187; �, 2. STORMWATER AGREEMENT RECORDED IN BK 13302, PG 1983 AND ' f 23 769 SF '� / � DB 9290 \PG 1243 r CURVE TABLE CURVE LENGTH RADIUS CHORD BEARING C1 92.85 500.00 92.72 S2429'02 "W C2 33.45 500.00 33.44 N8826'43 "W C3 41.43 320.00 41.40 S16'37'21 "E C4 114.93 150.00 112.14 N34-51'51"W CENTERLINE TABLE LINE LENGTH BEARING L102 155.26 S 19'09'50" L103 300.67 S29'48'13" L104 225.00 S29'48'1 3W L105 288.99 S86 31'44 "E L106 179.88 N89'38' 17 "E Ll07 96.79 S20'19'54 "E L108 135.35 S1 2'54'48 "E L109 155.78 S56'48'54 "E L110 82.20 S55'49'55 "E 1_111 1 224.76 S58'1 8'2e'E L112 1 96.30 S0834'1 8"W 1�= 30' CP &L EASEMENT ��+� es • .y PIN# 0775.02 -75 -8961 ' _ STORMWATER MAINTENANCE COVENANTS RECORDED IN BK 13302, PG 1920. \ '` DB 2143 \PG 523 / sb�R/w // SSS� �� ZONED: R -2 \ \ \s PHASING NOTES: R5' S238sr �\\`' 93 25' MPOD % ,/ 1. PHASE 1 WILL INCLUDE ROADS 1 AND 2 AND SEWER OUTFALLS WATERCOURSE BUFFER S001 /S002 /S004 TO SERVICE LOTS 1 -27 INCLUDING THE STORMWATER ' / \ \ \\ ,593 SF // 22 �.\ 701 `2� �; �o , , %/ BMP IN THE OPEN .SPACE LOT 36 AND SEWER OUTFACE S005 AT REAR OF CONSTRUCT HALF 32 EDGE -EDGE 8 / / O 'L.o �Lo 1 t / % oQ x i 3 a / oa - \ / LOTS 8/9 TO SERVICE UPSTREAM PROPERTIES.. ROADWAY ALONG FRONGATE OF Q �� i O / 16,257 SF ,w ' TRENTON ROAD FRONTAGE PER COR ��, 24,443 SF , f , -� 2. PHASE 2 WILL INCLUDE ROADS 3 AND 4 TO SERVICE LOTS 27 -35 AND NCDOT STANDARDS =P��/ �� \ \ \,�,� �'° �� `� \` /;j,� \ \\ , > - INCLUDING SEWER OUTFALL S003 BETWEEN LOTS 27/28 TO SERVICE A/ ' \\ �, ��, /� I � L `� UM TEAD /' \ UPSTREAM PROPERTY. SUWIVISION `S� \ \ \ v / / /SIGHT \ \ 23 rr�_' ' /��t� ® \` �ASEMENT \\ 20,668 SF ecP. 1 / �� i 1 N \F J / WAKE COUNTY \ % \ \\ 22,237 SF / 16 SIDEWALjC \'� \\ ��T+ �, L43 i REEDY RK, LLC \ _ �/ \ DB 2350 PG 401 N F / 16,315 SF i '\ \� DB 9859 \l�°G 528 �% �,\ DB 2327 \PG 142 TRENTON ROAD LLC / \ \ �' `� ;'' \.� DB 11610 PG 2494 / / \\ / a �� 4 PIN 0775.02 85 -6616 \ \ i # ti \ v PIN# 0775 -02 -95 -8103 PIN#0775.02 -75 -1253 'Y' %� / `� \ \ •"+ 1 24 i L4 4 s� `�: ZONED: 12 ZONED: R -4 I 0 J O ` \ CENTERLINE OF R NCH IS ZONED: R -2 \ / 1 ;0 48` PROPERTY LINE/ I IN CALLS 0.89 ACRES 22,338 SF / / 20,913 SF } 7� L42 -,L77A E , ..� 67 - 2 49; t r- - -- EXISTING 20' 16 08844 SF / �5k -- � _ ;cn LS t CENTERLI�CE OF BRrNCH , \. \ \ \ ^ \ \ / o % p1 4s R _ `• CITY OF RALEIGH -' 51 SEWER EASEMENT ZONE X 27,190 SF \ 1 25 53 L,, , Re / "\ L5 5 5P- `J ° r ♦ \ i '' \7 1 l 20,436 SF I L 58`� /. j 23,7504 SF 14 J B= t 3_0! ;..,� J/ ZONE AE , v /r 1 SF i pC.�� 'M3 L 1 / \ DEDICATION FOR y�f N \F TRENTON ROAD ��1 \ \R p ' -` �� 18 ) \ �. 64 a+ a 0 L6 i .-'o COUNTY OF WAKE , E• R3 /J HC 26 ' ^` F DB 2375 \PG 687 x182'02 �. 7 0 0 24, 678 SF t L6 I -- --_ `- - \ ? h 1 l 1 r t ��+ 9 -_- _ 50' BM 1975 PG 132 %� r 1 S 23 795 SF / C 28,4 8� SF cP � I 27,475 SF _ - � L6 70 °.t � , _ NRB r 4 0 , � o �\`-- -_ -__- � r \ : s \ SPIN# 0775.02 -95 -8103. - f, - . f f 120' PRIVATE STORM 1 m I ,a o : L 2`� /' S y 1 5`1T1 '=i ZONED: R -2 RA Gb!' SEWER PHAS S t I - - - - - J EASEMENT _ _ - \ ` F�A'EM NT I L7 4g / - ` C ZONE X F. .. / �.� � _- � .r L7. •ry�j ,'1..� ----� fv ,. ' '• / i`P �•%. - 1 fr '� �f' - 09.5 " -• -.�:� / /'F _ i //i"� /J.. %� �F ,r. / J jJ ,,,/ \ 1 7.-- -� ri'� �j�Ct f. �� f J / ' / 81 , •/ / .:`' /1 X j ` % / / ' rr APPROX. •,. /� _t - x 71,9 3 SF L7 0 ^ 1 LocAnoN LOCanON --'� OPEN / , -_ - -_ , F. i - _ j / ;' r / '' / • � f / N \F 5 t 1 PROPOSED PROPOSED 1 TRENTON ROAD LLC 1 1 DRIVEWAYS DRIVEWAYS DB 11610 PG 2494 ° EXISTING � l PIN#0775.02- 75 -53f 0 'WETLAND t 20 CI EXISTING I ! ::.:. l � ~ ` RALEIGH SEWER : - ^ ZONED. R -4 WETLAND r I 8 1 _ S MENT RB __ -.._. t t ' f \ ISTING r' 21.91 ACRES 0 .• _ 50_N._.. -.._.. _:r r•_ l i _ -`_ �- - -• �- f - =--1 _ \ 4� , \ WETLAND ,�� �J \ 721184 SF i I I 63,148 SF `...� I - - - - -- / / \_ � ; - - ^ 39,020 SF I 1 - - - -- - / / _ _ __ Y i- / O -- - - - - - -I i -- - - - - -- - __ 1/ARIA WIDTH PRIVATE \ �� �. ` �` 20 PRIVATE �-� I I I - 34 �•,.• ; / � �•- --- - - - - -- 20' PRIVATE STORM / / �- - -- / / 1 STORM I O I r / EASEMENT l STOR SEMENT TO �� �� 86,489 SF 30,908 SF I1 10 �_ 11 ( I ; �: EASEMENT ! 31 I I 32 33 /I ENCOMPA�S TRUC �� �� \ �� I I 41,043 SF I j O O I 1 / / / i 1 -I =I I I / �� \` _` I 1 I i 11 1 34,852 SF I I / N F �9 / ' - -- _ / / 1 I 37,990 SF �� 54,371 SF I 12 1� ,,� �� O ��- 1 \ I ( I 38,877 SF t I j 71,000 SF I I \ I - - -__1' � _ I 1 39=•e OF \� � I I I I TRENTON ROAD LLC , I - - - - - -- - I I I 53,648 SF RALEIGH EWER / .' .� \ �: �' ` 1 i I I 1 I 5' / W I / ,. \ i R \ ! DB 11588 PG 2?�1 " ------------- - - - - -� - -- I EASEM T i i 86,823 SF \ \ I t3'' �• l / ` I 35 - _ +sa 1 - - - - - -- 1 1�` - - '-- - - - - -- / e / PIN 0775.16 - 819 � I $IDEWAIJC 5 / / 0 � J_ ,.s_ _ - - -�- �__ : - -_..w __�/ ��/ ��� 20' CITY OF �l �� I 2s' a -B -A L - -R25i N � -J Il #ZONED /��/ RALEIGH SEWER r - +r +r HC ROAD 3 - - ;�- - J �� --------------- \ 10+00 He „, sr _ _ _ J ARE j /6,-16 / A6RES - „� S86'13'52 "E -- - - -- EASEMENT HC �s+o0 / - _ _- - _ 7r _ _------ - --) -1 10$19 sF r - -- / 1 0 / O N \F ' PHASE -��---- '�-' --�_ _` � .q - - - - - - - - / - - S -.__,' _ +so _ a° Del ^ _ _ _ '7s s �Q - �� I W STRIDGE --- 1 � - - - - -- H� _- L � / / 91,749 SF t 1p e �' 4.03 "E at - ---�_�� -DAyliv WAYNE TIMBERLAKE AV -- - - - - -- +��� V.P. EJG - _ - _ ._ ELP - N DB 7250 \PG 352 SU DIVISION �`'' .,,�, (LOTS 1 -26 � � - S86'18'08 "E ----------- - - - - -- , o � BM 1984 \PG 1626 , (LOTS 27 -35) N F - N F P 882.2$ - _ _ a � PIN# 0775.15 -64 -9775 / \ r. ZONED R -4; f�'� 36 �- ,, CLARK, SCOTT & AZIZA - - - - -_ - _ �T �� �`'�� ) CITY OF RALEIGH -� + +' PIN# 0775.02 -84 -9628 s7RU�cNRE _ ;9 DB 4263 \PG 263 / 0.42 AC N/F ° ° ° - 0�5, \ N \F .i iy `�\ HUDSON, GARY O i < ' BM 1984 \PG 41 , �Qy ZONING: R -10 N F 75.02 -94- 2645 - McCORMAC, STUART .O` DAVID L NETER 1 / `�. / IN# 07 IN# 0775.02 -94 -36 i O� J `� ' \ \ DB 7355 \PG 577 PIN# 0775.16 -84 -3760 /�/ / `�,��y�O�U F� 51NGLE FAMILY ELLMANN, RICHARD 0.35 AC 0.36 AC �� ` \. ZONED: R -4 i \\ BM 1984 PG 1626 / i� N F S N# 0775.02 -94 -06 4 ONING: R -10 i \ ifs \ .,O „� ZONING: R 0 ``+ / �rQj 0.48 AC USE: NGLE FAMILY `. � PIN# 0775.16 -74 -9791 /J" STATE OF `��F`� ZONING: R -10 USE: SING FAMILY ,�`\ ZONED: R -4 /�"� NORTH CAROLINA ''� DB 6694 \PG 201 USE: SINGLE FAMI Y ' ^�'\` ,,///` E \ � WESTRIDG BM 1988 \PG 1734 #0775.16 -84 -5543 ! \ �; SUBDIVISION ZONED: R -4 No. Revision Date B 1 CITY OF RALEIGH REVIEW COMMENTS 6/5/13 W &R 2 CITY OF RALEIGH REVIEW COMMENTS 6/21/13 W &R 93.39 N61'55'19 "E L4 81.95 S70'29'06 "E L5 83.92 N86'28'39 "E L6 124.90 S80'1 2'45"E L7 Designer W &R Scale 1"=100' Drawn By Date W &R 05/23/13 Checked By Job No. CD 02100179.10 THE WOODS AT UMSTEAD PHASE 2 N \F STATE OF NORTH CAROLINA r� HATCHED AREA EASEMENT TO WAKE LINE TABLE 0 ° o e LINE LENGTH BEARING L1 88.45 N51'24'48"W L2 128.37 N51'30'53"W L3 93.39 N61'55'19 "E L4 81.95 S70'29'06 "E L5 83.92 N86'28'39 "E L6 124.90 S80'1 2'45"E L7 97.46 N60'36'52 "E L8 99.27 N81'35'20 "E L9 122.84 SO1'12'39 "E L10 149.92 N33'40'29 "E Ll1 193.57 S67'44'02 "E L7 2 86.99 S49'04'31 "E L13 189.06 S061 4'35"W L14 49.57 S01' 15' 10 "E L15 72.88 N72733'1 3"W L16 5.15 S86'13'52 "E L17 27.25 S17'28'51 "W L18 60.69 S17'29'42°W L19 61.08 S17'45'01 "W L20 58.06 S1857'17"W L21 71.07 S20'45'1 0 "W L22 59.67 S23'25'08 "W 123 60.14 S25'12'51"W L24 60.11 S26'52'33 "W L25 60.48 S27'50'51 "W L26 61.35 S28'30'33"W L27 59.86 S28'51'40"W L28 56.35 S28'48'46"W L29 46.25 S28'57'1 3"W L30 60.37 S28'52'31 "W L31 57.52 528'46'23 "W L32 57.37 S29'28'51 "W L33 56.34 S29'04'43" L34 56.22 S29'27'1 7"W L35 57.58 S31'03'22"W L36 58.40 S3T38'33 "W L37 49.71 S35'1 8'35V L38 49.18 S36'12'55 "W L39 56.13 S36'35'00"W L40 1.80 S3637'1 3"W L41 23.55 S37'30'11"W L42 16.78 N36'1 8'53"W L43 31.83 N44 50'56"W 1_44 28.51 N36'43'20"W L45 14.84 N20'54'26 "E L46 8.07 N34 41'38" L47 19.03 N24'26'37 W L48 24.08 N3T39'02"W L49 18.93 N 15 18' 14 "E L50 9.48 N 1352'06'W L51 18.88 N41'31'18 "W L52 14.95 N l F48'41 "W L53 15.03 N30'2,3'1 1"E L54 14.84 NO3'08'48"W L55 9.26 N60'17'00" L56 14.43 S5413'23"W L57 17.62 N60'44'37" L58 31.12 N6323'26" L59 20.93 N68'24'14" L60 11.44 N32713'47"W L61 6.86 N16'59'25 "E L62 25.33 N27'07'12" L63 11.90 N08'01'02" L64 14.06 N39'36'07" L65 28.01 N23'20'1 7"W L66 6.06 N74'25'26"W L67 19.12 S55'06'30" L68 15.79 N85'02'03" L69 12.59 S78'12'57" L70 29.57 N38'46'1O"W L71 16.53 N60'53'21" L72 12.51 N38 42'29" L73 11.80 N00'33'29"W L74 12.35 N57 34'34" L75 31.74 N4T41'18" L76 12.47 = N05'08'15" L77 5.49 N27' 10'44" 100 0 100 200 hmmmmm SCALE: 1 = 100' COUNTY FOR WATERSHED SITE 11 -A -5 DB 2350 \PG 403 AREA 2.73 ACRES • , / N \F COUNTY OF WAKE DB 2375 \PG 687 / BM 1975 \PG 132 PIN# 0775.02 -95 -8103 ZONED: R -2 CONC MON "J" DB 2350/PG 405 o � S 0 e o 0 ° o e .. 312 o e o C�[�% °O 'I�A �OOOO o0 ° M.i o w 3 m I i a UD M 0 M N N m C 7 0 v I 3 CV 0 IL M H x /n 0 Q U N m W O t IL m m F 0 x 0 N i 0 0 i m i 0 Y HORIZONTAL RELATION OF WATER MAINS TO SEWERS WATER MAINS SHALL BE LAID AT LEAST 10 FEET LATERALLY FROM EXISTING OR SEWERS, UNLESS THE WATER MAIN IS LAID IN A SEPARATE TRENCH, WITH THE ELEVATION OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 INCHES ABOVE THE TOP. VERTICAL RELATION OF WATER MAINS TO SEWERS WHENEVER A WATER MAIN CROSSES OVER A SEWER, THE WATER MAIN SHALL BE LAID WITH THE ELEVATION OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 INCHES ABOVE THE SEWER, UNLESS BOTH THE WATER MAIN AND SEWER MAIN SHALL BE CONSTRUCTED OF DUCTILE IRON AND WITH JOINTS THAT ARE EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE CROSSING. WHENEVER A WATER MAIN CROSSES UNDER A SEWER, BOTH THE WATER MAIN AND THE SEWER SHALL BE CONSTRUCTED OF DUCTILE IRON AND WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FEET ON EACH SIDE OF THE CROSSING AND MAINTAIN A MINIMUM OF 18 INCH VERTICAL SEPARATION. A SECTION OF WATER MAIN PIPE SHALL BE CENTERED AT THE POINT OF CROSSING. VERTICAL RELATION OF STORM SEWER TO SANITARY SEWER & WATER MAINS WHENEVER A SANITARY SEWER OR WATER MAIN IS CROSSING OVER OR UNDER A STORM SEWER, A VERTICAL SEPARATION OF 12 INCHES SHALL BE MAINTAINED, UNLESS LINES ARE OF DUCTILE IRON OR ENCASED IN CONCRETE. NEUSE RIVER BUFFER NOTE: THE AREAS SHOWN ON THE RECORDED PLAT AS RIPARIAN BUFFER PROTECTION AREAS SHALL BE MAINTAINED IN PERPETUITY IN THEIR NATURAL OR MITIGATED CONDITION. NO PERSON OR ENTITY SHALL FILL, GRADE, EXCAVATE OR PERFORM ANY OTHER LAND DISTURBING ACTIVITIES; NOR CUT, REMOVE OR HARM ANY VEGETATION; NOR CONSTRUCT ANY STRUCTURES OR ADD ANY ADDITIONAL IMPERVIOUS SURFACES, NOR ALLOW ANIMAL GRAZING OR WATERING OR ANY OTHER AGRICULTURAL USE ON SUCH PROTECTED AREAS WITHOUT WRITTEN AUTHORIZATION - FROM THE DIVISION OF WATER QUALITY (DWQ) OR COMPLIANCE WITH THE RIPARIAN BUFFER PROTECTION RULES (15A NCAC 2B .0233 OR .0259). THIS COVENANT IS TO RUN WITH THE LAND, AND SHALL BE BINDING ON THE OWNER, AND ALL PARTIES CLAIMING UNDER IT. TRANSPORTATION NOTES 1. DOUBLE WHEELCHAIR RAMPS ARE TO BE INSTALLED AT ALL PUBLIC STREET INTERSECTIONS WHERE SIDEWALK IS REQUIRED. WHEN SIDEWALK IS NOT REQUIRED, CURB IS TO BE DEPRESSED AT ALL RAMP LOCATIONS AS SHOWN ON THIS STREET. 2. THE MINIMUM CORNER CLEARANCE FROM THE CURB LINE OR EDGE OF PAVEMENT OF INTERSECTING STREETS SHALL BE AT LEAST TWENTY (20) FEET FROM THE POINT OF TANGENCY OF THE RADIUS CURVATURE, OR TWENTY (20) FEET FROM THE INTERSECTION OF RIGHT -OF -WAY LINES, WHICHEVER IS GREATER. THE RADIUS OF THE DRIVEWAY SHALL NOT ENCROACH ON THE MINIMUM CORNER CLEARANCE. 3. WITHIN THE AREA OF A DEFINED SIGHT TRIANGLE, THERE SHALL BE NO SIGHT OBSTRUCTING OR PARTLY OBSTRUCTING WALL, FENCE, SIGN, FOLIAGE, BERMING OR PARKED VEHICLES BETWEEN HEIGHTS OF TWENTY -FOUR (24) INCHES AND EIGHT (8) FEET ABOVE THE CURB LINE ELEVATION OR THE NEAREST TRAVELED WAY IF NO CURBING EXISTS. 4. ALL CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH CITY OF RALEIGH AND /OR NCDOT STANDARDS AND SPECIFICATIONS. SPECIAL UTILITY NOTES: 1. ALL SANITARY SEWER MAINS GREATER THAN TWELVE (12) FEET IN DEPTH SHALL BE INSTALLED WITH % ; �j DUCTILE IRON PIPE. ' 2. ALL SANITARY SEWER MAIN EXTENSIONS SHALL BE 5' R /wfI " DEDICATION FOR / INSTALLED BY WORKING UPSTREAM FROM AN TRENTON ROAD / EXISTING MANHOLE. ANY EXCEPTIONS TO THIS METHOD .j SHALL BE APPROVED BY THE PUBLIC UTILITIES / DEPARTMENT. 3. ALL PROPOSED SANITARY SEWER SHALL BE 8" PVC, UNLESS OTHERWISE SHOWN. 30' PROPOSED NATURAL PROTECTIVE 11 t \ YARD l\ \ \ , 20' CITY II It \\ \P _ OF RALEIGH 1 \\ E.M. \., ELP SEWER J' EASEMENT E ,. , ® ELP LP / 1 !?0' PRIVATE STORMS \ / \� t t EASEMENT / E 10 , , b 30' CP &L EASEMENT ;' \\ CB/11 3 DB 2143 \PG 523 STORM DRAINAGE DESIGN TABLE Revision` Date B 1 7.22 in/hr W &R N= 0,0125 (RCP), or 0.009 (PVC) CLASS STRUCTIJRES AREA C QAREA QroTAL RIM EL LENGTH Pipe Size Pipe INVERT INVERT SLOPE From To (acres) 24 (cfs) (cfs) (ft); 00 (in) Material UP DOWN % 9.5 22 B FES 40 15 7.5 2 9.5 22 S FES 45 15 7.5 SYSTEM 1(PHASE 1) 9_5 22 B FES - 24 8 6 6 10 A CB 13 CB 12 029 0.65 1.37 1 -37 401 -52 26 15 RCP 397.52 397.39 0.50 CB 12 CB 11 0.08 0.79 0 -46 1.69 401.52 85 15 RCP 397.19 393.26 4.62 CD 11 FES 10 0.60 0:67 2.93 4.76 397.26 127 15 RCP 393.06 381 -00 9.50 SYSTEM 2 (PHASE 1) 03 29 03 28 0.16 0.70 0.81 0.81 402 -34 111 15 RCP 398.34 387.88' 9.42 CB 28 CB 27 0 -33 0.65 1.57 2.20 391.88 103 15 RCP 387.68 375.94 11.40 CB 27 CB 26 0.70 0.64 3.27 4.49 379.74 26 15 RCP 375 -74 375.49 0.96 CB 26 CB 25 0.17 0.74 0.92 5.37 379 -74 63 18 RCP 375.24 368.65 10.46 CB 25A CB 25 0-70 0.66 3.35 4.49 369.98 53 15 RCP 365.98 365.71 0.51 0625 Yl24 0.04 0.74 021 9 -97 373 -15 122 18 RCP 365 -46 359.87 4.58 Y124 YI23 0.45 0.63 2.05 11.92 36424 117 18 RCP 359.67 353.02 5.68 YI23 Y122 0 -46 0 -63 2.09 13 -92 356 -69 138 24 RCP 352 -52 351.82 0.51 YI22 YI21 0.70 0.63 3.18 16 -84 355 -66 121 24 RCP 351.82 351.22 0.50 YI21 FES 20 0.29 0.63 1.32 26 -92 354.31 73 36 RCP 349.39 346.00 4 -64 SYSTEM 3 (PHASE 1) CB 66 CB 65 0.30 0.70 1.53' 1.53 406.85 31 15 RCP 402.85 402.69 0-52 CB 65 CB 63 0.14 0.74 0.75 1 -91 406 -85 252 15 RCP 402.49 385.63 6.69 CB 80 CB 63 0.54 0.69 2.70 2.70 389.76 26 15 RCP 385.76 385 -63 0.50 CB 63 CB 62 0.10 0.76 0.55 4.69 389.76 83 15 RCP 385.43 381 -12 5 -19 CB 62 CB 61 0.05 0.72 0.26 4.92 385.12 103 15 RCP 380.92 376.31 4.48 CB 70 CB 61 0.67 0 -17 1.26 1.26 380.44 26 15 RCP 376.44 376 -31 0 -50 CB 61 CB 60 0.05 0.76 0.28 6.72 380 -44 177 15 RCP' 376.06 358 -57 9.88 CB 60 YI 21 0.40 0.73 2.13 9.13 363.07 38 15 RCP 355.54 351 -72 ` 9.95 SYSTEM 4 (PHASE 2) CB' 35 CB 34 0.16 0.08 0.7 0 -7 352.60 26 15 RCP 348.60 347 -80 3.08 CB 34 CB 33 0 -11 0 -07 0.5 1.2 352.60 102 15 RCP 347.60 340.20 7.25 CB 33 JB 32 025 0.13 1.1 2.3 344.00 47 15 RCP 340.00 33720 5 -96 JB 32 JB 31 - - - 2.3 343 -00 168 15 RCP 337.00 324.20 7.62 JB 31 FES 30 - - - 2.3 327.50 36 15 RCP 324.00 322.00 5.61 SYSTEN4 5 (PHASE 2) FES 45 CB 44 0.18 0.14 1 -0 1 -0 - 51 15 RCP 354.00 353.00 1.96 CB 44 CB 43 0.12 0.07 0.6 1.6 360.26 26 15 RCP 352.80 352.00 3.08 CB 43 CB 42 0.07 1 0.04 1 0.3 1.9 360 -26 92 15 RCP 351.80 348:.20 3.91 CB 42 JB 41 0.24 0.13 1.1 3.0 354.30 139 15 RCP 348.00 32120 19.28 JB 41 FES 40 -- -- - 3.0 325.00 8 15 RCP 321.00 320.70 3.75 f \ r r r .'X 25' MPOD WATERCOURSE , ,! BUFFER r a , Y// 122 ' U/ up. / 23 ENT �, JJ /SIGH 1`- \ \ \ , f 4 , ;N. i� 4� CITYlOF RALEIGH / 17 1 \ I C8 �� ' S0. _ ZONE X ` % SEWER EASEMENT �.�,,, ,=''r „� ' / / \ \ \ \, ! .'.,"' '` I r 1 \ , 25 E. •1 \e i =' l' ZONE AE DEDICATION FOR �1;( 4" �°` / / -- _ _ ! '�•_. -�, -i sms TRENTON ROAD ► _ Wr ` ! �'� O •'"� � / °ti'f -13 i( I i O ". / :ri \ \, `� � \y -- \ �. '" ®3�- .y --"'° °..,.. g�J� � '`__� -.-- f•' _._�r %y 6' 18 ! _ t g 50' NRB �� 1 it � bi / \ ! !! '.. ✓' j I ;?} \` .a\ % s \ \., , \'` f / r s`'-` `°... 2 � -..•"' da - � , � , {° d 120' PRIVATE STOI?,4 -l- ! /� �� - -- \ \ �`; I; I EASEMENT ~'" I ! 4, `• t `~ - A i'v,, �' . „. ., .,... ....•,e, _ �,._ _...-... / /�• .w,.. .. g. ` ^. � <e ELP `-w � r" Jr , t � /° .� _.- ....° L _- -,mow.. 3 r r'., C r +,. '- / •' f s� - � - - - - - I � � � ! ....„.- � _ -' ,t ` � •-,`";'" ZONE X REA // l / •.� � r -44u- .EXISTING / I ..✓ / - -_ -- / 20' CI `,� FESd ti _ _ i" / - -- ? r ' . ` w ELr !WETLAND 1 1 EXISTING ... .. I i0' Ls RALEIGH SEWER WET N 8 30' 1 1 EA MENT ~• :•... I I \ ✓ ...... �. , L - - WETLAND •r'' ;� � � ter"' ^ % ��� - M ` \ 'ti I. � ' , p4.. - -- i / � - -- -, - -� � � -- � 1 � ! �',•- -- - --';• // /.- � 20' PRIVATE i / / / O9 l - - --• I - - - - -- / / .. ,�__� VARIA WIDTH PRIVATE �i STORM S &SEMENT TO /� / / / / / / \�� `�� EASEMENT i _. ENCOMPA TRUCT Of- ----------- - �- - -- -------- �°'�� - -- RALEIGH EWER ,` / � .. l �• � ) � � - -, 1 M H 17 - - - - - --I � � .. EASEM T ®,. ...•,• �"`-` 6 _ _ ,.,. • -t- - L�..,__ _.:_.__ .----- ,•� -�_ / �/ 20 CITY OF -- �° . I 5 - - - -- !/ RALEIGH SEWER ROAD 3 - - -- - - - (4 - - - - - - - - - EASEMENT r._ ce _ t ' l'� _ '- _ `` •ww... o ` cJ`w AS g \�j; fir' - +T 1 (LOTS 1 -26- .- - - 'h. � � FIp .ELP. (LOTS 27 -35) -� No. Revision` Date B 1 CITY OF RALEIGH REVIEW COMMENTS 6/5/13 W &R 2 CITY OF RALEIGH REVIEW COMMENTS 6/21/13 W &R THICKNESS CLASS # (INCHES) (FEET) (FEET) (FEET) (INCHES) FES 1 15 8 0 ,A Designer W &R Scale 1 " =100' Drawn By Date W &R 05/23/13 Checked By Job No. CD 02100179.10 30' C17Y OF ALEIGkr SEWER rF� / J _ I a GENERAL NOTES - UTILITIES 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CITY OF RALEIGH STANDARDS & SPECIFICATIONS. 2. TOPOGRAPHIC INFORMATION PROVIDED BY WITHERS & RAVENEL, INC. 3. THE EXISTING UTILITIES SHOWN ON THE PLANS IS BASED ON THE BEST AVAILABLE INFORMATION, BUT CAN BE CONSIDERED ONLY AS APPROXIMATE. ANY POTENTIAL CONFLICTS WITH PROPOSED CONSTRUCTION SHALL BE REPORTED TO THE PROJECT ENGINEER FOR REVIEW PRIOR TO BEGINNING CONSTRUCTION. 4: ALL FIRE HYDRANTS SHALL BE INSTALLED ON A 6 -INCH LEAD WITH A HYDRANT BRANCH VALVE. THE BRANCH VALVE SHALL BE NO GREATER THAN ONE FOOT FROM THE MAIN AND INSIDE THE PAVEMENT WHEN POSSIBLE. THE VALVE SHALL BE MECHANICALLY RESTRAINED TO THE MAIN. 5. FIRE HYDRANTS SHALL BE PAINTED RED WITH HIGH REFLECTIVE SILVER CAPS AND BONNETS. 6. ALL WATER MAINS SHALL BE INSTALLED WITH A MINIMUM COVER OF 4 FEET FROM THE TOP OF THE FINISHED GROUND TO PIPE CROWN. 7. WATER MAINS SHALL BE MADE OF DUCTILE IRON PIPE AND SHALL BE CLASS 50, 51, OR 52 DESIGNED IN ACCORDANCE WITH AWWA STANDARD C- 150 -76. A MINIMUM WORKING PRESSURE OF 150 PSI SHALL BE PROVIDED. 8. ALL SANITARY SEWER MAINS SHALL HAVE A MINIMUM COVER OF 5 FEET IN TRAFFIC AREAS TO THE PIPE CROWN UNLESS DUCTILE IRON PIPE IS PROVIDED IN CLASS I BEDDING WHERE THE MINIMUM COVER SHALL BE 3 FEET. ALL SANITARY SEWER MAINS SHALL HAVE A MINIMUM COVER OF 3 FEET IN NON- TRAFFIC AREAS TO THE PIPE CROWN. 9. SANITARY SEWER MANHOLES SHALL BE 4 FEET IN DIAMETER UNLESS OTHERWISE SPECIFIED ON THE PLANS. 10. SANITARY SEWER MANHOLE TOPS SHALL BE SET FLUSH WITH PAVEMENT IN TRAFFIC AREAS AND SHALL BE SET AT LEAST ONE FOOT ABOVE GROUND LEVEL IN NON- TRAFFIC AREAS UNLESS OTHERWISE SPECIFIED. 11. THE CONTRACTOR' SHALL NOTIFY THE CITY OF RALEIGH ENGINEERING DEPARTMENT AT 890 -3030 TO SCHEDULE CONSTRUCTION INSPECTIONS. 12. SANITARY SEWER AND WATER PIPE TRENCH EXCAVATION AND BACKFILLING SHALL BE PERFORMED IN ACCORDANCE WITH CITY OF RALEIGH STANDARD SPECIFICATIONS. 13. SANITARY SEWER MAIN EASEMENTS SHALL BE GRADED SMOOTH, FREE FROM ROCK, BOULDERS, ROOTS, STUMPS, AND OTHER DEBRIS AND SEEDED AND MULCHED UPON COMPLETION OF CONSTRUCTION. 14. THE FLOW CHANNEL THROUGH MANHOLES SHOULD BE SMOOTH AND SHALL CONFORM TO THE SHAPE AND THE SLOPE OF THE ENTERING AND EXITING SEWER MAIN. DISSIPATOR DESIGN iNLETf PIPE DIA. APRON OUTLET D. STREAM RIP RAP RIP RAP OUTLET LENGTH WIDTH WIDTH THICKNESS CLASS # (INCHES) (FEET) (FEET) (FEET) (INCHES) FES 1 15 8 3.75 5 12 B FES 20 24 12 6 7 12 B FES 30 15 7.5 2 9.5 22 B FES 40 15 7.5 2 9.5 22 S FES 45 15 7.5 2 9_5 22 B FES - 24 8 6 6 10 A ALL UISSIPATORS SHALL HA`,+'E FABRIC UNDERUNERS. PHASING NOTES: 1 _ PHASE _1 WILL INCLUDE ROADS 1 AND 2 AND SEWER OUTFALLS S001 /S002 /S004 TO SERVICE LOTS 1 -27 INCLUDING THE STORMWATER BMP IN THE OPEN SPACE LOT 36 AND SEWER OUTFALL S005 AT REAR OF LOTS 8/9 TO SERVICE UPSTREAM PROPERTIES.. 2. PHASE 2 WILL INCLUDE ROADS 3 AND 4 TO SERVICE LOTS 27 -35 INCLUDING SEWER OUTFALL S003 BETWEEN LOTS 27/28 TO SERVICE UPSTREAM PROPERTY. 60- PHASE 1 (S001/S002) /20' PRIVATE STORM EASEMENT ? �. - �- - - l- � f +- - - - - may+ ��;1�.i'� - � ;•� �i I t % i��/ � /. IX FENCE LINE . z' S1fiUCCTURE -_� %s1 / 1 100 0 100 200 SCALE: 1 " = 100' CONC MON "J" DB 2350/PG 405 i Y ✓ i i 6 L 6 t P :fit P' .•_. jam' - ,...,....,.••. .r a , rip• � - , :.,,,% "'gy I i,:. . BMP MAIN 1. /4 CESS e N 1. I F EES 20 ` J6 'a J - 01 _ -w6 , 6( L_F � .� � � . � 0 L 0 F' F #50 r 10 LS - t -NV 3411'& - _- \ WI TIC_ - _J _ ,,,. -` 4 INV. 3410 °' F. °§ ; BYPASS � ..- '-• - ' C HAN °N E L {`•.\ °� `� i VARIABLE WIDTH,/ PRIVATE � ,,, STORM EASEMENT TO \ "- E N -C �PA -S S -B -M P S TR U C T U R, 0 = 1 / I Z ' r BMP B"ASIN 4" SKIMMER DEVICE w/ 3" ORIFICE (CONNECT TO 4" DIP GATE VALVE UNTIL SITE 4'x4' BOX IS STABILIZED) WATER LEVEL DURING STORM TRASH H0, PEAK FLOW ATTENUATION POOL - �I SLOPE 3:1 ANTI- FLOATATION DEVICE SEPARATE 4" DIP MTH 4" PLATE AND 1" WQ ORIFICE OUTLET 4" DIP DRAIN 1' MIN. FREEBOARD ANTI -SEEP COLLAR---- RCP OUTLET PIPE CROSS SECTION ' X 4' REINFORCED ONCRETE RISER ELEV. 351.00 TRUCTURE 4" DIP TO 24" RCP LS -VFS CLASS III RISER STRUCURE PLAN VIEW No. DIMENSIONS ELEV. TOP OF DAM WIDTH 10' 352.00 ANTI -SEEP COLLAR 48" x 48" - 1 INCH W.Q. ORIFICE 1" DIA 346.00 TOP OF ANTI - FLOATATION 7'x7'x3' 345.50 RISER OPENING 4'x4' BOX 350.25 ATTENUATION ORIFICE 9" DIA. 347.90 SEPARATE 4" DIP MTH 4" PLATE AND 1" WQ ORIFICE OUTLET 4" DIP DRAIN 1' MIN. FREEBOARD ANTI -SEEP COLLAR---- RCP OUTLET PIPE CROSS SECTION ' X 4' REINFORCED ONCRETE RISER ELEV. 351.00 TRUCTURE 4" DIP TO 24" RCP LS -VFS CLASS III RISER STRUCURE PLAN VIEW No. Revision. Date B 1 CITY OF RALEIGH REVIEW COMMENTS 6/5/13 W &R 2 CITY OF RALEIGH REVIEW COMMENTS 6/21/13 W &R TOP WIDTH. 12 -FEET FLOW DEPTH FOR 10 -YEAR STORM: 0.65 FEET FREEBOARD DURING 10 -YEAR STORM: 1.35 FEET 6 JB 41 325.00 321.00 1 320.50 1 15 TOP OF DAM MINIMUM SLOPE 2.5:1 EARTH DAM DISSIPATOR PAD W/ FABRIC LINER SEE BMP CHARTS BELOW LEFT FOR SIZING DATA 9" ATTENUATION ORIFICE (INSTALL ORIFICE FOLLOWING SITE STABILIZATION) 'O -RING' JOINT, 4" NRS GATE VALVE COVER DIP OUTLET WITH WASHED #57 STONE, (CONNECT SKIMMER TO GATE VALVE UNTIL SITE IS STABILIZED) 4" PLATE WITH d 1" WQ ORIFICE OUTLET 14 REBAR 12" PRECAST REINFORCED CONCRETE 4'x4' BOX RISER NOTE: PLACE STEM SUPPORTS AT 3 FROM BASE 1/4"x 2" STEEL STRAP W/ 2 - 3/4" ANCHOR BOLTS 2 STRAPS REQ'D GROUT EACH SIDE _ JOINT SEALED WITH A -LOCK NEOPRENE GASKET CAST IN MANHOLE WALL 'O -RING' GASKETED CLASS 111 RCP PAVED INVERT ' °' GROUT 6" I •'•' �'• `. i'' _'mot c _, � .� '.d �� ' •a ' RISER & DRAWDOWN DEVICE DETAIL arTalil1# k 2000 PSF MIN. BEARING CAPACITY BENEATH COLLAR NTS 112- PREFORMED JOINT LER, 12 WIDE SEC77ON TYPICAL ANTI -SEEP COLLAR NTS VEGETATED FILTER STRIP PLANTING SPECIFICATIONS THE VEGETATED FILTER STRIP SHALL BE CLEARED AND COVERED N1TH A MINIMUM OF 6- INCCHES OF TOPSOIL MIX 1 -2 CUBIC YARDS OF PEAT' MOSS OR COMPOST PER 1,000 SQUARE FEET (SF) INTO THE TOPSOIL IN ADDITION, A ONE -11ME START -UP FERTILIZATION SHOULD BE ADDED PER THE TABLE BELOM GRASS OTHER THAN CENTIPEDE • 75 LOS OF GROUND LIMESTONE PER 1,000 SF • A STARTED 'TYPE FERTILIZER, HIGH IN PHOSPHORUS, BASED ON THE TYPE OF GRASS AND PLANTING METHOD CENTIPEDE • 1/2 LB OF NITROGEN PER 1,000 SF GRASS TYPE • GRASS TYPE SHALL BE TALL FESCUE OR COMMOM BERMUDA. GRASS SHALL BE SOD, GROWN IN NON- CLAYEY SOIL • WATER SOD 'FREQUENTLY FOR THE FIRST THREE WEEKS AFTER INSTALLATION SO THAT THE FIRST 1.5" OF SOIL IS KEPT MOIST. BMP #1 'LEVEL SPREADER CALCULATIONS PEAK DISCHARGE FROM BMP DURING 10 -YEAR STORM: 0.20 CFS MAX. CAPACITY OF 100 -FOOT LONG LEVEL SPREADER WITH VEGETATED FILTER STRIP: 10 CFS MANHOLE RING & COVER ACCESS FOREBAY NOT REQUIRED FOR USE WITH DRY DETENTION AND SPUTTER BOX OFFSET OVER STEPS & DRAWDOWN VALVE FEET OF LEVEL LIP REQUIRED PER CFS: 10 FT /CFS 3" PRECAST CONCRETE SLAB CALCULATED MIN. LENGTH. OF LEVEL LIP: 2 Fl- * USE MIN. 10 -FOOT LEVEL SPREADER LENGTH. 6 "x4' OPENING ON FOUR SIDES 350.25 ELEV. BM2#1 VEGETATED FILTER STRIP (VFS) WIDTH OF VFS. 30 -FEET ELEVATION AT DOWNSLOPE OF LEVEL UP. 341.00 _ ELEVATION AT THE END OF THE VFS: 340.0 SLOPE: 3.337. EE450 BYPASS CHANNEL 02100179.10 V- DITCH: 31 SIDE SLOPES TOP WIDTH. 12 -FEET FLOW DEPTH FOR 10 -YEAR STORM: 0.65 FEET FREEBOARD DURING 10 -YEAR STORM: 1.35 FEET PEAK VELOCITY DURING 10 -YEAR STORM: 4.69 FT /SEC BMP #1 RISER TOP DETAIL CHANNEL SL O CLASS CHANNEL LININNEG: CLASS 1 RIP RAP Designer W &R Scale NOTED Drawn By Date W &R 05/23 13 Checked By Job No. CD 02100179.10 THE AT UMSTEAD ® PHASE FES #30 LEVEL SPREADER CALCULATIONS - - �- f l r �F ` C _ w DA 0.91 AC C. 0.57 Q: 0.52 CFS BYPASS * USE 48 LF 6' DIP ® 1.67 %' SLOPE CHANNEL' * SET BYPASS INVERT AT CROWN OF ` LEVEL SPREADER OUTLET m r ` ' ` FES 130 FOREBAY DESIGN , fi �� ` �✓ ` r i r , %` {.. f %i `` * 7 SA = 0.2% * IMPERVIOUS SURFACE a X AREA IMPERVIOUS AREA: 547. \ '� / r' %fi` 34 L E V _ L SA: 43 SF , * USE 7'X7' FOREBAY - ° �/// \r'' f-i S P R E D E R z FES #30 LEVEL SPREADER LENGTH ti _ - _ _• - - , % \r;r ' ;j ~ . �',�' WOODED VEGETATION f' `k 50 LF /CFS * 0.52 CFS = 26.0 LF * PROVIDE 34 LF BASED ON 65 LF /CFS 50' N R B * 24" CURB & GUTTER * LEVEL SPREADER UP. 323.00 GUTTER: 322.50 'NE "` _� �� ,, f ,.•_ _ X,•4 BYPASS CHANNEL _ _ _S00 , - TOP WIDTH 10.5' , -� - Z - = - - b-I�P @ 1.6 7 7 HEIGHT 1.7 B ---� _ _ ; - SIDE SLOPES: 3:1 �'' �'`" - ENTERS STREAM AT AN ANGLE - ARMOR WITH CLASS 1 RIP -RAP 22" DEEP " - _ �: LEVEL SPREADER DETAIL - FES30 SCALE: 1"=30' FES #40 LEVEL SPREADER CALCULATIONS DA: 0.66 AC C: 0.38 I: 1 IN /HR Q: 0.25 CFS * USE 90 LF 6" DIP 0 1.0% SLOPE * SET BYPASS INVERT AT CROWN OF LEVEL SPREADER OUTLET FES #40 FOREBAY DESIGN SA = 0.27. * IMPERVIOUS SURFACE AREA IMPERVIOUS AREA: 45% SA: 26 SF * USE 06' FOREBAY FES #40 LEVEL SPREADER LENGTH WOODED VEGETATION 50 LF /CFS * 0.25 CFS = 12.5 LF * PROVIDE 17 LF BASE DON 65 LF /CFS * 24" CURB & GUTTER * LEVEL SPREADER LIP. 314.00 GUTTER. 313.50 BYPASS CHANNEL - V -DITCH - TOP WIDTH = 9.5' - HEIGHT = 1.6' - SIDE SLOPES: 3:1 - ENTERS STREAM AT AN ANGLE - ARMOR WITH CLASS 1 RIP -RAP 22" DEEP LEVEL SPREADER DETAIL - FES #40 SCALE: 1"=30' x1 � 50' NRB `17 - L_E_UE L SPREADER_ 9 0_. -LF O F / r I o' v � � ,-° ,1. � Vii+ fir/ �//' .,' ,-, ,A •o BYPASS CHANNEL G RAS S EDtl,S-- -W -ALE E E-S #4 0 - - Y. (D)" RCP STRTCTI1tE CCLASS III NL41 i PIPE LNNT L\ /0LT CONCRETE APRON AIAUli PIPE LN /OUP RC'PDLA, pl (E)" DIP # 1' -7" (B) V -7" (D)" RCP (D) CLASS III CONCRETE APRON CONCRETE APRO� -NCDOT STD 840.18 REINFORCED CONCRETE DROP INLET (SEE DETAIL) FLOW TO v LEVEL SPREADER/ /� FOREBAY E) DIP RCP ' I �D) ' Y FLOW TO BY -PASS ass III PLAN CHANNEL LEVEL SPREADER FLOW BYPASS STRUCTURE DETAIL FLOW BYPASS STRUCTURE DESIGN STRTCTI1tE RM, ELEVATION NL41 i PIPE LNNT L\ /0LT BYPASS PIPE INT OUT AIAUli PIPE LN /OUP RC'PDLA, pl BYPASS PIPE DIi'DLA, pj # (A) (B) (C) (D) (E JB 31 327.50 324.00 323.50 15 6 JB 41 325.00 321.00 1 320.50 1 15 1 6 6' 1 2' -0' 6' CONCRETE APRON I(D)" RCP IffsS III NOTES: I 1. USE CLASS "B" CONCRETE THROUGHOUT. 2. USE 1" CHAMFER ON ALL OUTSIDE EXPOSED CORNERS. SECTION Y -Y CONSTRUCTION SEQUENCE: NOTE: ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CURRENT CITY OF RALEIGH AND NCDOT STANDARD SPECIFICATIONS. 1. SEDIMENT BASIN #1 TO BE CONSTRUCTED AS SHOWN WITH PERMANENT RISER STRUCTURE FOR FUTURE CONVERSION TO STORMWATER BMP FACILITY. 2. SKIMMER TO BE INSTALLED ON THE LOW FLOW DRAIN FOR USE DURING CONSTRUCTION WITH GATE VALVE OPEN FOR DISCHARGE TO THE BYPASS. PIPES TO LEVEL SPREADERS TO BE CAPPED UNTIL SITE STABILIZED. 3. WHEN INFRASTRUCTURE COMPLETE AND ALL DISTURBED AREAS STABILIZED, ° ° °� *N oCAR °�DOOO CALL STORMWATER INSPECTOR (STEPHEN LEISCHNER AT 919- 278 -6461) oo 0 TO SCHEDULE AN ON -SITE INSPECTION. oy a e 4. IF SITE IS APPROVED, FLUSH AND CLEAN ALL STORMWATER SYSTEM PIPES, r`F e o S E A L o o' CLEAN AND REMOVE SEDIMENT FROM SB #1, REMOVE SKIMMER DEVICE, INSTALL LEVEL SPREADERS, AND REMOVE CAPS TO CONVERT TO BMPs. a °e O g o 5. PROVIDE ADEQUATE COVER AND SEED OUT ANY BARE AREAS ASSOCIATED �,p °° WITH CONVERSION OF SB #1 AND INSTALLATION OF THE LEVEL SPREADERS. OO9 (k Coco ° °°OO8 6. AS -BUILT PLAN AND CERTIFICATION (FORM 511) MUST BE SUBMITTED AND 808808 ACCEPTED PRIOR TO SCHEDULING FINAL INSPECTION. Sheet No. & mm"AVIE L NT DETAILS 2 ENGINEERS I PL�INNERS I' SURVEYORS 111 MacKenan Drive Cary, North Carolina 27511 tel: 919 -469 -3340 fax: 919 -467 -6008 www.withersravenel.com