Loading...
HomeMy WebLinkAboutWQ0024769_Regional Office Historical File Pre 2018Michas! F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality January 12, 2005 The Honorable Elbert Richardson, Mayor Town of Troutman 400 North Eastway Drive Troutman, North Carolina 28166 Subject: Permit No. WQ0024769 Town of Troutman Charles Center Wastewater Collection System Extension Iredell County, North Carolina Dear Mayor Richardson: In accordance with your application received on December 23, 2004, we are forwarding herewith Permit No. WQ0024769, dated January 12, 2005, to the Town of Troutman for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria .for the Fast -Track, Permitting of. Pump Stations and Force Mains adopted June 1,; 2000,- as applicable, unless speciticlly mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 281I5 Phone: (704) 663-1699 Fax: (704) 663-6040 Internet h2o.enr.stete.nc.us Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper N V Carolina „aturally Mayor Elbert Richardson Page 2 January 12, 2005 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Town of Troutman for the construction and operation of approximately 1,062 linear feet of 8-inch gravity sewer as part of the Charles Center project, and the discharge of 3,000 gallons per day of collected domestic wastewater into the Town of Troutman's existing sewerage system, pursuant to the application received December 23, 2004, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Statesville Third Creek WVVTP (NPDES No. NC0020591) prior to being discharged into the receiving stream. This permit shall become voidable unless the agreement between the Town of Troutman and the City of Statesville for the collection and final treatment of wastewater is in full force and effect. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Basinger at (704) 663-1699. Sincerely, for Alan W. Klimek, P.E. cc: Iredell County Health Department Mooresville Regional Office, Water Quality Section (WVIT['F Permit No. NC0020591) Douglas Dowell, Jr., Dowell and Company, PC Water Quality Central Files Marie Doklovic, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1 C. 1 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the Life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permiftee from complying with any and a!I statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 12th day of January, 2005. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION • /2 for Alan W. Klimek, P ., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0024769 3 Fast Track Engineering Certification Permit No. WQ0024769 January 12, 2005 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications.are required for any changes resulting in non-compliance with this permit. regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION El Partial' El Final 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the Charles Center, lredell County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND. THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 ATTN: DEE BROWDER The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. PPCATION for GRAVITY SEWERS, 1'UMP STATIONS, AND FORCE MAINS PAC E 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner 1 a. Town of Troutman Full Legal Name (company, municipality, HOA, utility, etc. 1b, 1�e 0 z 0 chards --f4,a yGr Signing Official Name and Title (Please review 15A NCAC 2H .02 Application Number: (to be completed by DWQ) for authorized signing officials! lc. The Legal entity who will own this system is: © Individual Ej Federal Municipality 0 Stale/County El Private Partnership 0 Corporation D Other (specify): ld 400 North Eastway Dr_ Street Address tf, NC State 1 h,, 704-528-7600 1 i. 704-528-7605 Telephone Facsimile 2. Project (Facility) Information, 2a. Charles Center Brief Project Name (pe 3. Contact Person: III refer to this name) 3a. Douglas L Dowell .lr _ Dowell and Name and Affiliate 3b. 704-660-9697 Phone Number one Who Can PC uesrlon le. Troutman. City lg. 28166 Zip Code 1j. administratortownoftroutrrtan.o EE-mail -...�.a _.�.. .�. 2b. Iredeil County Where Project is Located this Application ieland7896@aol.com E-mail 1. Project is Ir4 New 0 Modification (of an existing permit) odifcation, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line sizeAength, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is Public (skip to Item 8(3)) 0 Private (go to Item 2(a)) 2a, If private, applicant will be: 2bw if sold, facilities owned by a se one) 0 Retaining Ownership (i.e, store, church, single office, etc.) or 0 Public Utility (Instruction III) [� Leasing units (lots, townhomes, etc. - skip to Item 8(3)) 0 Homeowner Assoc./Developer (instruction IV) D Selling units (lots, townhomes, etc. - go to item B(2b)) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. Third Creek 4b. NC 0020591 WWTF Permit No. Name of WWTF 5a. Town of Troutman 5b. 8" Owner of Downstream Sewer Receiving Sewer Size ` Permit Number of [stree 6. The origin of this wastewater is (check all that apply): 0 Residential Subdivision El ApartmentsiCondominiums 0 Mobile Home Park 0 School Q Restaurant Office © Car Wash E] Institution 0 Hospital El Church 0 Nursing Home 0 Other (specify):... 7. Volume of wastewater to be permitted in this project: 3000 gallons per day 8. If the permitted flow is zero, indicate why: 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. O Rehabilitation or replacement of existing sewer with no new flow expected 100 Domestic/Commercial % Industrial % Other (specify): FrA irto - Rev. 7 04/04 PLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 r1 0 W M ZZL r Z 0 0 Z Q lte 0 Z M 1e W O. m 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(I) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). 6 lots x 20 employees x 25 gpd = 3000 gpd it/ Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main (use the pull down menu) 8" 1062 3 — i ENTER TOTAL LINE LENGTH IN MILES 0.20 it Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (self chosen - as shown on" Design Flow' Operational Point plans for cross-reference) 1 (MGD) GPM ® TDH Power Reliability Option (1- dual line feed; 2- permanent generator w/ATS; 3- portable generator wltelemetry; 4-wet well storage) j E 12. Does the sewer system comply with the Minimum Mains (latest version), the Gravity Sewer Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Design Criteria (latest version) and 15A NCAC 2lri _0200 as applicable? pertinent minimum design criteria or regulation and indicate why a OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION l Yes ■ No if no, please reference the variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? Sedimentation and Erosion Control Plan? Stormwater? ❑ Yes IN No ® N/A ® Yes ❑ No • NIA ❑ Yes ❑ No 121 WA FT A (17103 - Rev. 7 041114 , ICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02103 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as .. necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality Z ;regional office (see instructions for addresses) OR indicate the following: - ►�� A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope Qwaterbody; AND, - (j ■ A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability Li- option for any pump station near a Class C down slope waterbody_ 0) Location 1D on Map mi.(selt chosen -as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification U w- ice-, GO 0 Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicants Certification: 1, , attest that this application for Charles Center has been reviewed by me and is accurate and complete to the best of my knowledge. l understand that if all required parts of this application are not completed and That if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina Genera( Statutes 143-2i5.6A and 143-215.6B, any person who knowingfy makes any false statement, representation, or - certification in an/ p! • = tion shall • - guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 _ as well as •• i •.a, :. I p • t s� • • r vi» Lion. 1 a. dor �,, 1 2-2 2- 0 4 Signing Official Sign-ture Date •. Professional Engineer's Certification: " ` 1 attest that this application for Charles Center has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation 1-- ' ' to the best of my knowledge. ! further attest that to the best of my knowledge the proposed design has been prepared in Q ` accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June IL , 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal p • package may have been developed by otherprofessionals, inclusion of these materials under my signature and seal it + signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. Note: In • W , - accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, 0 representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Ci 2a. Douglas L Dowell Jr Professional Engineer Name 2b. Dowell and Company PC Engineering Firm j+,r. �� CQ �y y 2c. po box 3504 ; �OR.�,..,,,„,,ROf % Address 1 ,,"Q�pFESsjo"'-_ -y, 1,� tip: - 2d. Mooresville 2e. NC 2f. 28117 c i- 5'I,i r = i • F - "r �Y C_...._..._._.. State Zip _._ 2g.i:r' .:- 704-660-9697 2h. 704-664-5177 2i. leland7896@aoi.com i '-. Telephone Facsimile E-mail al, Signatu 4Yat� D Telephone FTA Q?JO'i - Rev_ 2 04/04 SHEPHERDS QUADRANGLE NORTH CAROLINA 7.5 MINUTE SERIES (TOPOGRAPHIC) 71 s -r-Ls s L E 9 M 48,0 DDe OrC E T B 4 D1 /11 /05 Permit Number WQ0024769 Permit Tracking Slip Program Category Non -discharge Status Project Type In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Individual Extensions Primary Reviewer Permit Contact Affiliation sonja.basinger Permitted Flow 3000 Facility Facility Name Charles Center Location Address Owner Major/Minor Region Minor Mooresville County Iredell Facility Contact Affiliation Owner Name Owner Type Town of Troutman Government - Municipal Owner Affiliation Elbert PO BOX 26 Troutman Dates/Events Richardson NC 281660026 Scheduled Orig Issue App Received Draft Initiated Issuance 12/23/04 Public Notice Issue Effective Expiration i f 2„105. Regulated Activities Requested/Received Events Commercial or industrial, other Additional information requested Wastewater collection Additional information received Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin A Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen Sullins, Director Division of Water Quality July 19, 2007 David Saleeby, Town Manager Town of Troutman P.O. Box 26 Troutman, NC 28166 SUBJECT: Charles Center Permit No. WQ0024769 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for the subject project on June 25, 2007. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit. Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a copy. . You are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from http://h2o.enr.state.nc.us/ndpu/ndpuapps.html#Sewer. If you have any questions concerning this document or the completion of Form PNOCF-S (if necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail.net. Sir>cerely, c 0 EA_ItS•3 t,WRobert Krebs Surface Water Protection Regional Supervisor Enclosure Cc: Ben Thomas, West Consultants 405 S. Sterling St. Morganton, NC 28655 Surface Water Protection Section Central Flies (certification page only) NorthCarolina Naturally Pretreatment, Emergency Response and Collection Systems Unit Internet http:Nh2o.enr.nc.state.uslndpu 1617 Mail Service Center, Raleigh, NC 27699-1617 An Equal opportunity Action Employer Telephone (919) 733-5083 Fax (919) 733-0059 50% recycledll0% post -consumer paper Fast Track Engineerinci Certification Permit No. WQ0024769 January 12, 2005 Complete and submit this form to the permit issuing regional office with the t One copy of the project record drawings (plan & profile views of sewer system extension Supporting design calculations (selected pumps, system curve, operating point, available storageportable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project shcuid be clearly iciertified on the record drawings or in written su mary form. Permit modifications are rewired for any changes resulting in nor-orridjance with this permit, r +ulations or munr design criteria. iowirg: es) of the wastewater collection This project shall not be considered coMplete ear allowed to operateuntil this Engineer's Cert=ffcation end al_ required supporting documentation have been received by the Division. Therefore, It Is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION ❑ Partial' $Fir.al 4 as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe�pertodically, ❑ weekly, [] full time) the construction of the Charles Center, Iredell County project for the Permittee he reby state that, to the best of my abilities„ due care and diligence was used in the observation of the construction such that the construction was observed tc be built within substantial compliance of this permit; 15A NCAC 2H ,0200: the Division of';,Neter Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12„ 1996 as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations arid Force Mains adopted June .1, 2000 as applicable; and other supporting materials North Carolina Professional Engine seal, signature, and date. SEND THIS FORM & SUPPORTING DOCUMENTATiON WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS The Permittee is responsible for trackin wastewater flow made tributary to the waste Engineer's Certification shall be considered a vio enforcement actions. MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 ATTN: DEE BROWDER ,rtitications up until a final certification is received. Any Ilection system extension prior to completion of this n of the permit and shall subject the Perinittee to appropriate H 990000001ii1 "N/9t :£,L'Is/ os:E« tooa £ tnr CNrs; Obi ONSULL YV '4 i .F 17{:... June 2,0, 2007 405 Sou S ion 828 4 '5 433 `at s. Dee Browder Surface Water Protection Unit NCDENR-_ Division of Water Qua. 610 East Center Avenue, Suite 301 Mooresville, NC 28115 y RE; Sown ofTrout.: an — The Charles Center WQ 0024769 Final Certification Dear Ms. Browvder: ton. tst:" 286'55 Please find enclosed for yourte iew as -built drawings, calculations, and nineer's certification for the subject project. Please note that although Dowell & Company produced the design, West Consultants, PLLC performed the inspections and thus has certified the construction. If there are any issues, questions, or needs for information as you make your review, please direct them to me rather than Dowell & Company,. Thank you for your ass stance, Sincerely, C NSI. LTANTS, P Bet r anun B. PE Encl cc: Mr, Charles Onsmd osures REVISED PUMP STATION CALCULATIONS FOR CHARLES CENTER PROJECT NO.: 00-014 DEC 28, 2005 - - fJ/✓f it.4-s D _ '.4 k- _ it/14 f _ s '77: -✓ -,4 Gtsc. /� 0-V S P4, 41.v / 7-cam' ' 7 4Z. P/171- g _ ( !.2 7` o'►/ G ✓Win, r ✓a /4 f i 5 77 ✓G, Lv TS / t.v,✓G / S.1a,r,/ - 4I. 7P4 jr Ga 71 45; v r--r /✓o/r.,14) !- /17`,Ae- LL L _ 3 (- b %S j `{-0.E' Tat/ o I S /.3/JP r7s r c i4-u rr.. (I (.0 r) ekhu e-o C/ rued / �a / r� 7, iAP H0 /6-D 4-4>0 147:4/32- X J4iy e.0 52) ./7) GMLITE: 1 C 6 p.D/ (_ /7- 3 6 se)-P-r. F45 7- FM) g o 7-eL De, - 3170 .5,o1-7-5 ( 57.> $e)11-5 ( `to 6.P) ioo (ioc, r)0 937S- *Z.) 1- 42 CID 0 "4- /z5/ ZJ2.717 2(.,/ 2-7C §/45e--- Arep- 4-cfrA) v-71/ 94-v 6, Ot, 2, 7 Pic, a 3 PAT / © r)+x Q/Wa X Z, 5 3 0 , Sv 4.1 P S ate. , e /3 mac.-cn...) 77rL,R/ 0y L r'�1. (o 1I/E7— ltJ E%.t_- 0 I. = 7r (3} (1. S� 3/7 6M. /Iv Mc. /473/VA-fir& 6 3/7 (, 7) 19 77'-r e v -rf rt r✓ a .✓ 19i! ( w //,/ /-*iri/ nr s df 2 "X.—L-2119V N',d' 7 ' a4. 2 'u 11> N'h! -a c71� r ��✓ z '2 N' /) /'//_ ��►-�) A "7944,/ .Lye - M ../ � s'Z 'aL A 4'd 5 620/ 7h ) #f hrnc l�q _9 -:-24, .ii4?46j 4 2 a 4/1 J 1 1 p / i _ 1 cJo 0 LI .6) r 1 [-t(-LIAi c<9- z +.i 1 vA —c) ,i !, i, ., ij J ram/ /4 QS -4 i�` i ' xg ALO (A) Q � I r� f �a� 1.-V/) 1 it 4 `,19 1 /1 -`+A'S c- id - O ' / Skic /vct(L . / ,d CV/!d izs 01. •2 h^6 v / h• -(cam /mod `u rvw .u72 5 'Of z / t 1a -79 cev/h/ 640 ' 74 Gf - T::t,/ s S /,V 4 Q= /o:� GiP/-t Wr 1-4- S 6am-6-ec G , A fv /-44 4 / /// C4J, ,6, 5 - P O L: r,F 14/ `-, 7 NI P e- S 7,1 IAZEN WILLIAM EQUATION FOR PIPES - DIA.? (INCHES) ELEVATION HEAD 4 j 1091 f 140 42.7 TOTAL LENGTH? FLOW (GPM 25 50 75 -ems 100 125 150 175 200 225 250 HEAD LOSS (FRICTION) 0.54 1.95 4.12 7.02 10.61 14.87 19.79 25.34 31.51 38.30 Chw? TOTAL HEAD 43.24 44.65 46.82 53.31 57.57 62.49 68.04 74.21 81.00 Chw COEFFICIENTS FOR PIPE: PVC -NEW PVC - OLD VITRIFIED CLAY CONCRETE OR CONCRETE LINED 140 120 110 130 IAZEN WVILLIAM EQUATION FOR PIPES - (� vG a 4- ELEVATION HEAD I 42.7 DIA,? (INCHES) .1 TOTAL LENGTH? f Chw? 4 1091 1 120 FLOW (GPM) 25 50 75 125 150 175 200 225 250 HEAD LOSS (FRICTION 0.72 2.59 5.48 9.34 14.12 19.79 26.32 33.71 41.92 50.96 TOTAL HEAD 43.42 45.29 48.18 52.04-- 56.82 62.49 69.02 76:41 84.62 93.66 Chw COEFFICIENTS FOR PIPE: PVC - NEW PVC - OLD VITRIFIED CLAY CONCRETE OR CONCRETE LINED 140 120 110 130 4" 5432 MV SUBMERSIBLE 1765 RPM NO. OF VANES 2 SUCTION SIZE 4" IMPELLER T4B1A INLET AREA 26.22 SQ,IN. MAX. SPHERE 3" TOTAL HEAD Fairbanks Morse Pump 10 _+ 40 I 1� II 4411144 was..._ '1 hareatigkiiii -AM • oleo, 20 NM 111:111i-. ITI!r ; 7t - al 900 i,�rrrr/J.riirrrr�rrrr/r,iil',iifrr 0 25 50 75 100 125 0 0 200 300 400 500 600 700 800 150 175 200 1000 1100 1200 ,225 250 275 40 - 10 i = 20 - 5 w w w 0) z 90 20- 0 2 0 0 U.S. GPM M3/HR 8/1./97 Gt/cr //vs e 2).4 777/ c /G ( 7, 2-A) c Zit)) 7s-3,2, d.-14 4/"/41,kr- fi, b Z• V -%F 1/a 7 75-3 -L( 4,2.V) Gee-/ 6rhe f L��y✓Gft.�3 _ /2vrf-f J'5i 1?rs .1/ Ge. 7._L., p .T f s 7 Y/ -2- 7????7-L-C /4 60 3 (7 y7-1_,.) cOE 7 co/()c-H) S'52 y,o/7 I9/ J C� 5 ) — C2 $ 1� s �o� ty_b/ ''1 - 1 ? �c 1 / 0 20 1:'/ 4A ssr, `1.r/rv�� % /c� / 943 Q 1,,r •il 7-„t{V S x ' } .---4 , •1®,7 ¶ ( , 4'' ,'7 31N %5 )c?-) Y:9 8 0_ -' -7'2 07 �,. a A t. is s dr C) i 2r9 rap/-r- 777 n c = P s 77V j— G U c of 1- S 4/ L. 3 `1c a 3'0 I- / 9, �0 D Ea.) '1 a, PE 9_,1/' V?U/ Z, series TINDALL CONCRETE PRODUCTS, INC. • P_O. BOX 1778 • SPARTANBURG, S.C. 29304 • TELEPHONE (803) 576-3230 © 1979 24„ 8„� INS. DIA. i(tYP•1 UNIFORM 16" SPACING OF STEPS G 72 TT 1 G48 SECTIONS AS REQUIRED 48" INS. DIA. 7 ". G72 - 64R 26" MAX. 8" 6" 7 G72 BASES VARIABLE IN 8" INCREMENTS 72" INS. DIA. 2° SLOPE GASKET ENLARGED VIEW OF JOINT + _ 113116" t. ENLARGED SECTION OF 0-RING GASKET ASTM C361 ONE OR MORE OPENINGS AS REQUIRED IN BASES NOTES: ALL STANDARD SEWER MANHOLE SECTIONS MEET OR EXCEED THE REQUIREMENTS OF ASTM C478. TWO LIFTING HOLES ARE PROVIDED IN EACH SECTION FOR ON -SITE HANDLING. PROPER STRONGBACKS OR LIFTING HARNESSES ARE REQUIRED FOR SAFE HANDLING OF SECTIONS. TINDALL CONCRETE PRODUCTS IS NOT RESPONSIBLE FOR DAMAGE OR INJURY DURING HANDLING. ALL STEPS INSTALLED IN MANHOLE SECTIONS HAVE SERRATED TREAD & TALL ENIT LUGS TO PREVENT FEET FROM SLIPPING. BUTYL RUBBER SEALANT 1S RECOMMENDED FOR SEALING JOINTS. 0-RING GASKETS MAY BE USED. series TINDALL CONCRETE PRODUCTS, INC. • P.O. BOX 1778 • SPARTANBURG, S.C. 29304 • TELEPHONE (803) 576-3230 cQ 1979 1F I 16" LAY. LGTH. TRANSITION TOP G72 TT 3702 LBS. RISER LAYING LGTH. 64" -' 48" 32" 16" FLAT SLAB TOP G72 FST 4099 LBS. SECTION G 72-64R G 72-48R G 72-32R G72-16R POUNDS 10038 7412 4941 2470 LAYING LGTH. 72" 64" -� 56" 48" SECTION G 72- 72B G 72-64 B G 72-56B G 72-488 POUNDS 13924 12863 11802 10741 MONOLITHIC BASE 12" LAY. LGTH. 8" PIPE OPENINGS OR FLEXIBLE CONNECTORS ARE AVAILABLE ON SPECIAL ORDER. 8