Loading...
HomeMy WebLinkAboutNC0020427_Pretreatment Inspection_20000128,„. NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES ,January 28, 2000 • Mr. Larry Cobler Director of Plant Operations City of Rockingham PO Box 250 Rockingham, NC 28379 • DIVISION OF WATER QUALITY FAYETTEVILLE REGIONAL, OFFICE SUBJECT: Pretreatment Compliance Inspection City of Rockingham NPDES Permit No. NC0020427 Richmond County Dear Mr. Cobler: Enclosed please find a copy of the Pretreatment Compliance Inspection Report for the inspection conducted on Janua,ry 20, 2000. During the inspection, an SIU (Trinity Manufacturing, Incorporated) was inspected and records were reviewed for this facility. The report reveals a summary and observations of the City's prCtreatment program. • The conclusion ofthe inspection was that the City administers a program that monitors SIUs and enforces rules and regulations as deemed necessary for the proper administering of the pretreatment program. You are commended for your continued success in maintaining your program in'such a manner that has ensured the best water quality to the stream as well as maintaining the NPDES permit limits. • Please review the attached report. If you or your staff have any questions, do not hesitate to call me at (910) 486-1541 ext. 340. Sincerely, DL/bs Enclosures cc: • DWQ Pretreatment Unit Dale Lopez Environmental Specialist II SCI;.01.1 Egr EMEMIMMI 225 GREEN STREET, SUITE.714 / SYSTEL BLD. FAYETTEVILLE, NORTH CAROLINA 28301-5043 PHONE 91.0486-1541 FAX 910-486-0707 AN EQUAL OPPORTUNITY / AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/1O% POST -CONSUMER PAPER • • 1.. ..,.. • c4 NORTH CAROLINA DIVISION OF WATER QUALITY PRETREATMENT COMPLIANCE INSPECTION REPORT FAYETTEVILLE REGIONAL OFFICE BACKGROUND INFORMATION 1. Control Authority (POTW) Name: City of Rockingham WWTP 2. Control Authority Representative: Larry Cobler 3. Title: Plant Operations Director 4. Last Meeting: June 16, 1999 Inspection Type (Circle One): I Audit 5. Has Program Completed All Requirements From The Previous Inspection or Program Info Sheet(s)? / No 6. Is POTW Under An Order That Includes Pretreatment Conditions? Yes /©o Order Type And Number: N/A Are Milestone Dates Being Met? Yes / No PCS CODING 1 Trans.Code Program NPDES Number MM/DD/YY Inspec.Type Inspector INI f NI Cf 0 f 0 f2 10 f4 f2 17 f 01/20/00 I P _ S_ (DTIA) (TYPI) (INSP) . 7. Current Number Of Significant Industrial Users (SIUS)? 8. Current Number Of Categorical Industrial Users (CIUS)? Trinity Manufacturing , Inc. Fac.Type 111 (FACC) SIUS 10 1 9. Number Of SIUS Not Inspected By POTW In The Last Calendar Year? 0 10. Number Of SIUS Not Sampled By POTW In The Last Calendar Year? 0 11. Enter The Higher Number of 9 or 10. 0 12. Number Of SIUS With No IUP, or With An Expired IUP? 0 CIUS NOIN NOCM 13. Number Of SIUS In SNC For Either Reporting or Limits Violations During Either Of The Last 2 Semi-annual Periods (Total Number of SIUs in SNC)? 14. * Number Of SIUS In SNC For Reporting (Owens and Wundies) During Either of the Last 2 Semi-annual Periods? 15. Number Of SIUS In SNC For Limits Violations During Either Of The Last 2 Semi-annual Periods? 16. Number Of SIUS In SNC For Both Reporting and Limits Violations During Either Of The Last 2 Semi-annual Periods? 2 2 0 0 PSNC MSNC SNPS * Owens failed to do their third quarter monitoring. Wundies failed to complete their first and second quarter analysis for total suspended solids, biochemical oxygen demand, and their annual metal analysis Filename: NCPCIWP Page 1 Date: 1/28/2000 POTW INTERVIEW 17. Since The Last PCI, Has The POTW Had Any NPDES Limits Violations? If Yes, What Are The Parameters and How are These Problems Being Addressed? 18. Since The Last PCI, Has The POTW Had Any Problems Related To An Industrial Discharge (Interference, Pass -Through, Blockage, Citizens' Complaints, Increased Sludge Production, Etc.)? If Yes, How Are These Problems Being Addressed? 19. Which Industries Have Been in SNC During Either of the Last 2 Semi- annual Periods? Have Any Industries in SNC (During Either of the Last 2 Semi-annual Periods) Not Been Published for Public Notice? Yes /(E) Yes / No SNC for Limits: None SNC for Reporting: Owens and Wundies Not Published: 20. Which Industries Are On Compliance Schedules or Orders? For All SIUs on an Order, Has a Signed Copy of the Order Been Sent to the Division? 21. Are Any Permits Or Civil Penalties Currently Under Adjudication? If Yes, Which Ones? PRETREATMENT PROGRAM ELEMENTS REVIEW - Please review POTW files and complete the following: Trinity Manufacturing Company Yes No Program Element Date of Last Approval Date Next Due, If Applicable Headworks Analysis (HWA) 5/23/97 Industrial Waste Survey (IWS) 7/17/97 Sewer Use Ordinance (SUO) 10/13/94 Enforcement Response Plan (ERP) 8/31/94 Long Term Monitoring Plan (LTMP) 9/10/97 LTMP File Review: 22. Is the LTMP Monitoring Being Conducted at Appropriate Locations and Frequencies? / No 23. Should any Pollutants of Concern be Eliminated From or Added to the LTMP? Yes / No If Yes, Which Ones? Eliminated: Added: 24. Are Correct Detection Levels Being Used for all LTMP Monitoring? / No (with Burlington Research) 25. Is the LTMP Data Maintained in a Table or Equivalent? Yes / No Is the Table Adequate I'ej/ No Filename: NCPCIWP Page 2 Date: 1/28/2000 INDUSTRIAL USER PERMIT (UP) FILE REVIEW 26. User Name 1.Trinity Manufacturing, Inc. 27. IUP Number 2. 28. Does the File Contain Current Permit 29. Permit Expiration Date? 30. Categorical Standard Applied (I.E. 40 CFR 413, Etc.) or N/A The baseline monitoring report has been sent to Dana Folley. 31. Does the File Contain Permit Application Completed Within One Year Prior to Permit Issue Date? 32. Does the File Contain an Inspection Completed Within the Last Calendar Year? 12/15/99 33. a. Does The File Contain a Slug Control Plan? b. If No, Is One Needed? (See Inspection Form from POTW) 34. For 40 CFR 413 And 433 TTO Certifiers, Does The File Contain a Toxic Organic Management Plan (TOMP)? 35. a. Does the File Contain Original Permit Review Letter from the Division? b. All Issues Resolved? 12/16/93 36. During the Most Recent Semi -Annual Period, Did the POTW Complete its Sampling as Required by UP? The POTW did more than required. 37. Does the File Contain POTW Sampling Chain -Of -Custody's? Excellent form. 38. During the Most Recent Semi -Annual Period, Did the SIU Complete its Sampling as Required By IUP? 39. Does Sampling Indicate Flow or Production? On BOD sheet and surcharge sheet. 40. During the Most Recent Semi -Annual Period, Did the POTW Identify All Non -Compliance from Both POTW and SIU Sampling? 41. a. Was the POTW Notified by SIU (Within 24 Hours) of all Self - Monitoring Violations? b. Did Industry Resample Within 30 Days? Filename: NCPCIWP Page 3 Date: 1/28/2000 3. 0009 a. es / No a. Yes / No a. Yes / No 6/30/01 Yes No Yes / No Yes / No el No t Yes i- No Yes / No a.1 - / No b. CD / No . Yes / No Yes / No Yes / No Yes / No Yes / No ED Yes / No N/A Yes / No N/A a. 4a)/ No b. le / No a. Yes / No b. Yes / No a. Yes / No b. Yes / No •/ No Yes / No Yes / No ea)/ No Yes / No Yes / No 0 / No Yes / No Yes / No Yes / No Fes / No Yes / No 'es / No N/A Yes / No Yes / No a.Ye NoN/A .110 NoN/A a. Yes / No b. Yes / No a. Yes / No b. Yes / No 42. Was the SIU Promptly Notified of any Violations (Per ERP)? 43. During the Most Recent Semi -Annual Period, Was the SIU in SNC? 44. During the Most Recent Semi -Annual Period, Was Enforcement Taken as Specified in the POTWs ERP? 45. Does the File Contain Penalty Assessment Notices? None Assessed 46. Does the File Contain Proof of Penalty Collection? None Collected 47. a. Does the File Contain any Current Enforcement Orders? None under Orders b. Is SIU in Compliance With Order? 48. Did the POTW Representative have Difficulty in Obtaining any of this Requested Information for You? Yes No N/A Yes / No Yes / No CO/ No Yes / No Yes / No • es / No N/A Yes / No Yes / No Yes 0 N/A Yes / No - Yes / No Yes /©o N/A Yes / No Yes / No N/A a.Yes,1/A a. Yes / No b. Yes / No a. Yes / No b. Yes / No b.Yes/Nt$ Yes No Yes 1h No Yes / No PCI SUMMARY PCI Comments: The pretreatment program for this facility was well organized and all information was readily available. The facility had excellent document forms for Chain -of -Custody and Notice of Violations. Requirements: Recommendations: NOD: Yes / No NOV: Yes / No QNCR: Yes G POTW Rating: Satisfactory X Marginal Unsatisfactory PCI COMPLETED BY: Dale Lopez. Environmental Specialist II _ i Filename: NCPCIWP Page 4 Date: 1/28/2000 Date: 1/20/00 INDUSTRY INSPECTION CODING: Trans.Code Main Program Permit Number MM/DD/YY Inspec.Type Inspector Fac.Type J I N I C l 0 1 0 12 l 0 14 12 17 1 01 / 20 // 00 ._±_l I S I 21 1. (DTIA) (TYPI) (INSP) (FACC) 1. Industry Inspected: Trinity Manufacturing, Incorporated 2. Industry Address: P.O. Box 1519 Hamlet, NC 28345 3. Type of Industry/Product: Chemical / Chloropicrin, Bleach, and Aluminum Cleaner 4. Industry Contact: Keith Warbington / Karen Messana Title: Technical Manager / Safety Director Phone: 910-582-5650 Ext. 227 / 111 Fax: 910-582-4433 5. Does the POTW use The Division Model Inspection Form or Equivalent? Yes / No 6. Did the POTW Contact Conduct the Following Parts of the Industrial Inspection Thoroughly? Comments: A. Initial Interview Yes B Plant Tour Yes C. Pretreatment Tour Yes D. Sampling Review Yes E. Exit Interview Yes Industrial Inspection Comments: Filename: NCPCIWP Page 5 Date: 1/28/2000