Loading...
HomeMy WebLinkAboutSW4200702_Plansheet - Utility Plan_20210810UTILITY LEGEND UTILITY EASEMENT SANS PROPOSED SANITARY SEWER EXISTING SANITARY SEWER Q SANITARY MANHOLE ® SANITARY CLEANOUT w PROPOSED WATERMAIN EXISTING WATERMAIN '� PROPOSED BEND ISI PROPOSED TEE ® PROPOSED GATE VALVE d PROPOSED REDUCER PROPOSED HYDRANT ASSEMBLY - - -OHP- - - EXISTING OVERHEAD POWER cd EXISTING POWER STRUCTURE - UFO - EXISTING UNDERGROUND COMMUNICATION PROPOSED NATURAL GAS - G- - EXISTING NATURAL GAS - - - - - - - - - - - EXISTING STORM SEWER PROPOSED STORM SEWER GENERAL: 1. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL EXISTING UTILITIES PRIOR TO START OF CONSTRUCTION. 2. ALL EROSION CONTROL DEVICES SHALL BE CONSTRUCTED AND MAINTAINED IN ACCORDANCE WITH THE MOST CURRENT STANDARDS OF THE LAND QUALITY SECTION OF THE NCDENR. 3. STABILIZATION STONE UNDER PIPING TO BE PLACED AS REQUIRED BY CITY INSPECTOR WHEN CONDITIONS WARRANT. 4. AS A MINIMUM REQUIREMENT, ALL GRADED AREAS NOT UNDER PAVEMENT AND WITHIN THE RIGHT-OF-WAY AND/OR EASEMENTS SHALL BE PREPARED, FERTILIZED AND LIMED, SEEDED, AND MULCHED IMMEDIATELY UPON COMPLETION OF CONSTRUCTION AS FOLLOWS (APPLICATION RATE PER 1,000 SQUARE FEET): TYPE I SEEDING (LAWNS OR OTHER FOCAL AREAS) 100 LBS. OF LIME 20 LBS. OF 10-20-20 OR 20 LBS. OF 10-10-10 IN COMBINATION WITH 4 LBS OF 0-46-0 5 LBS. OF TALL FESCUE, CONTAINING A BLEND OF 2 OR MORE TALL FESCUES 1 LB. OF KENBLUE OR KENTUCKY BLUEGRASS 1 LB. OF WINTER ANNUAL RYE (NOVEMBER 1 TO MARCH 1) TYPE II SEEDING (GENERAL OR LOW MAINTENANCE AREAS) 100 LBS. OF LIME 15 LBS. OF 10-20-20 OR 15 LBS. OF 10-10-10 IN COMBINATION WITH 3 LBS. OF 0-46-0 4 LBS. OF TALL FESCUE, CONTAINING A BLEND OF 2 OR MORE TALL FESCUES 1 LB. OF SERICEA LESPEDEZA (USE UNSCARIFIED SEED AUGUST 15 TO FEBRUARY 1) '/4 LB. OF GERMAN MILLET (MAY 1 TO AUGUST 15) 1 LB. OF RYE GRAIN (PRIOR TO MAY 1 OR AFTER AUGUST 15) SEEDING MIXTURES OTHER THAN THOSE LISTED ABOVE MUST BE APPROVED BY THE CITY INSPECTOR PRIOR TO SEEDING. 5. PRIOR TO REQUESTING A FINAL INSPECTION, THE OWNER MUST SUBMIT RECORD DRAWINGS AND ENGINEER'S CERTIFICATION TO THE ENGINEERING DIVISION'S RECORD CENTER. THE OWNER MUST ALSO SUBMIT THE CONSTRUCTION CHECKLIST TO THE CITY INSPECTOR. 6. ALL WORK MUST CARRY A ONE-YEAR WARRANTY TO COVER ALL DEFECTS IN MATERIALS AND WORKMANSHIP. 7. PRIOR TO BEGINNING ANY WORK WITHIN NCDOT RIGHT-OF-WAY, THE CONTRACTOR MUST HAVE A COPY OF THE THREE -PARTY ENCROACHMENT AGREEMENT ON THE JOB SITE. CONTACT 336-703-6600. 8. CONTACT CONSTRUCTION AND MAINTENANCE AT 336-771-5130 TO ARRANGE FOR CONSTRUCTION INSPECTION. A CITY INSPECTOR WILL APPROVE BACKFLOW PREVENTER TYPE, VAULT, EXACT LOCATION, AND INSPECTION REQUIREMENTS PRIOR TO INSTALLATION. A CITY INSPECTOR SHALL BE PRESENT WHEN MAKING OR TERMINATING WATER AND SEWER CONNECTIONS INTO NEW OR EXISTING WATER AND SEWER LINES. 9. ALL CONSTRUCTION, MATERIALS, AND SANITATION PROCEDURES SHALL MEET OR EXCEED THE REQUIREMENTS OF THE NORTH CAROLINA PLUMBING CODE AND THE CITY OF WINSTON-SALEM TECHNICAL SPECIFICATIONS AND DETAIL DRAWINGS. 10. CONTACT RENATA LEONARD AT 336-747-6998 OR CITY LINKAT 336-727-8000 FOR STREET CUT PERMIT AND PRIOR TO ANY STREET CUTS. 11. CROSS -CONNECTION CONTROL PROTECTION DEVICES ARE REQUIRED BASED ON DEGREE OF HEALTH HAZARD INVOLVED AS LISTED IN APPENDIX B OF THE RULES GOVERNING PUBLIC WATER SYSTEMS IN NORTH CAROLINA. THESE GUIDELINES ARE THE MINIMUM REQUIREMENTS. THE DEVICES SHALL MEET AMERICAN SOCIETY OF SANITARY ENGINEERING (ASSE) STANDARDS OR BE ON THE UNIVERSITY OF SOUTHERN CALIFORNIA APPROVAL LIST. THE DEVICES SHALL BE INSTALLED AND TESTED (BOTH INITIAL AND PERIODIC TESTING THEREAFTER) IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR THE LOCAL CROSS -CONNECTION CONTROL PROGRAM, WHICHEVER IS MORE STRINGENT. 12. AS OF JULY 1, 2011, ALL METERS SHALL BE PURCHASED THROUGH THE CITY/COUNTY UTILITIES DIVISION. CONTRACTORS AND DEVELOPERS CAN PURCHASE METERS AT THE UTILITIES BUSINESS OFFICE OFF THE LOBBY OF THE STUART MUNICIPAL BUILDING, 100 E. FIRST STREET. 13. ENGINEER OF RECORD IS RESPONSIBLE FOR ENSURING THAT THE FIRE LINE FROM THE BACK OF THE BACK FLOW PREVENTER TO THE BUILDING IS INSTALLED TO THE MOST CURRENT EDITION OF THE NORTH CAROLINA FIRE CODE. 14. IF WORK IS TO BE DONE ON AN EXISTING HYDRANT MORE THAN THIRTY YEARS OLD, CONTACT UTILITIES CONSTRUCTION AND MAINTENANCE TO HAVE HYDRANT EXCHANGED FOR A NEW HYDRANT. 15. EXISTING WATER CONNECTIONS NOT INTENDED FOR REUSE SHALL BE TERMINATED AT THE MAIN. %" THROUGH 2" CONNECTIONS THE CORPORATION SHALL BE CUT-OFF AND THE COPPER SERVICE LINE CUT THRU AT THE CORPORATION. 3" THROUGH 10" CONNECTIONS THE TAPPING VALVE AND SLEEVE OR TEE SHALL BE REMOVED AND REPLACED WITH MECHANICAL JOINT SLEEVES AND DUCTILE IRON PIPE INSTALLED TO CITY OF WINSTON-SALEM STANDARD. VAULTS OR BOXES SHALL BE PROPERLY REMOVED OR DEMOLISHED. CONNECTIONS INTENDED FOR REUSE ARE SUBJECT TO ASSESSMENT AND UPGRADE. CONTACT THE METER SHOP 336-771-5130, FOR ASSISTANCE. 16. ENGINEER OF RECORD IS RESPONSIBLE FOR ENSURING ALL FIRE LINE BACKFLOW PREVENTERS AND 3" AND LARGER DOMESTIC WATER BACKFLOW PREVENTERS ARE INSTALLED TO THE MOST CURRENT EDITION OF THE WINSTON-SALEM / FORSYTH COUNTY UTILITIES CROSS -CONNECTION CONTROLSTANDARDS. - - - - - - - - - - - - - _ 400 PAIR COPPER ---- -- - ---- - 25 PAIR COPPER INV=914.68' L\ / 100 PAIR COPPER RIM=924.18' �� / 600 PAIR COPPER m CP#5 / " G) -� m OHP'i- \ OHP- 00 Z OHP- - - - - rn -OH P -- -- - � �ZOHP-----OHP-----OHP-----OHP---W a W '0 \ - - - - -dH0 PVC IRRIGATIONTj c" IRRIGATION � PUMP - --III ------------------------ -----------SSTATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - G/�� PVC IRRIGATION I 30' UTILITY EASEMENT -PER COUNTY\�/ - I _ FM� \ 9S \\ / RECORD DRAWING #11792--- p BFP Go - - - ------ ------------ -- FM vv�-I CL ANOU L 1 1/2"SANITARY SEWER FORCE MAIN -FM- _L - - - - FM - - - - - \ / _ 52 LF\6" SE I _ - - FM - - - - - FM - - - - - \ / - - \`\� TO,B E CAST I \ _ F \� �C\�SOIL\PIPE`\ - - - - - 2„WATERLINEAl ----- ------ \ _4 `0 \ I I C P#F 01 \ HORSESHOE PIT ' n_ / I ,'T �z 5\ 6" DfR F 2E SERVI � R/F4 R \\ ^ \ \ CE FENCE -�JP TO R \\ \ \ KM0 / i/ BENCH \/ , \ I Z0 I INSTCLA N. IN I �$WEPR,K TIN HAyG S i i 00 i ' \� I -PERMITTED AVOID 00 ' i I � 36 0 FENCE POS "WOOD . � I , � (TYP). SPLIT RAIL ��, - PIV m i i m i SPORTS FIELD FENCE I� I 6" PVGI=IRE SE_ ICE WATER LINE / °o ; °o TOWN OF LEWI VILLE I 1 I (36'=1VIIN. cov C7 i i n T�X PINS 58�5-14-9288 5885-14-1 47 RECONNECT EXISTING PO R I \PVC D MESTIC WATER / \ i O i i 1 FEED TO SLIDING GATE TO REM N r C i i r C i ASfOMBINED�INIDB. 352 PG. 1700�1703 (COORDINATE W/ PROVIDE \INS (36" MIN. COVER) / c r TACT 1 & 2 OF PB. 9. PG. 50 CAMERA I \I •.• / G I I I I POLE - I ••,.••' IRNN G O Z�NING: RS-�40 PVC T-TW'�-� W W W W W W PVC IRRIGATION RECONNECT EXISTING 20' INGRESS/EGRESS EASEMENT i POWER FEED TO REMAIN 46, PG 50 S I L------_ r------- , (COORDINATE W/ PROVIDER) BLEACHERS ; BLEACHERS ' 6" 22.5' BEND I I BLEACHERS PRIVATE FIRE ------ HYDRANT ASSEMBLY &VALVE SPA j CG UGP- i 6" 11. 5' B ND ' -6 45' BEND ____--------- 3" 5° BEAD_ ------------- F w 3" PVC DOMESTIC ATER LINE (36" MIN. OVER) G 6" PVC FIRE SERVI E WATE INE (36" MIN. C ER) 6" 11.25' B D � D 3" 11. BEND 'BEND 6" 45' BEND TRANSFORMER (SEE MEP PLANS & COORDINATE W/ PROVIDER) WATER AND/OR SANITARY SEWER: 1. THE MOST CURRENT EDITION OF THE CITY OF WINSTON-SALEM TECHNICAL SPECIFICATIONS AND DETAIL DRAWINGS FOR WATER LINE AND SANITARY SEWER LINE CONSTRUCTION WILL GOVERN ALL WATER AND SANITARY SEWER CONSTRUCTION. 2. ACCEPTABLE WORKING CONDITIONS OF SANITARY SEWER STRUCTURES AND PIPING SHALL BE VERIFIED BY THE CONTRACTOR AND ALL CONDITIONS FOUND TO BE UNACCEPTABLE SHALL BE REPORTED TO UTILITIES CONSTRUCTION AND MAINTENANCE AT 336-727-8000, PRIOR TO ANY CONNECTIONS, EXTENSIONS, OR STRUCTURES BEING INSTALLED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANUP AND REPAIR OF UNACCEPTABLE CONDITIONS THAT RESULT FROM FAILURE TO REPORT SUCH CONDITIONS PRIOR TO COMMENCING WORK OR THAT RESULT FROM WORK BEING PERFORMED. 3. SANITARY SEWER CONNECTIONS SHALL BE SERVICE WEIGHT CAST IRON SOIL PIPE WITH 4-INCH CLEANOUTS AND SHALL MEET CITY OF WINSTON-SALEM SPECIFICATIONS. 4. PROPOSED PUBLIC OR PRIVATE HYDRANTS INSTALLED OR RELOCATED SHALL MEET OR EXCEED CITY OF WINSTON-SALEM'S SPECIFICATIONS AND DETAIL VII-39 TO INCLUDE HYDRANT TEE, VALVE, AND WINSTON-SALEM THREADS. PRIVATE HYDRANTS SHALL BE EQUIPPED WITH A DOUBLE CHECK DETECTOR ASSEMBLY AND SHALL BE PAINTED RED. 5. DENSITY TESTS BY AN INDEPENDENT TESTING LAB ARE TO BE MADE AS DIRECTED BY THE CITY INSPECTOR AT THE OWNER'S EXPENSE. FINAL INSPECTION PROCEDURE: 1. OWNER SUBMITS RECORD DRAWINGS AND ENGINEER'S CERTIFICATION TO THE ENGINEERING DIVISION'S RECORD CENTER. 2. UPON APPROVAL BY THE RECORD CENTER, OWNER MAY REQUEST FINAL INSPECTION FOR WATER AND/OR SANITARY SEWER. OWNER SHALL THEN SUBMIT THE CONSTRUCTION CHECKLIST FOR WATER AND/OR SANITARY SEWER TO THE CITY INSPECTOR. 1. A NC LICENSED UTILITY CONTRACTOR SHALL INSTALL THE 6" FIRE LINE WITH A 6" REDUCED PRESSURE ASSEMBLY IN ABOVE GROUND HEATED ENCLOSURE TO CITY OF WINSTON SALEM STANDARD WHICH SHALL INCLUDE A STORZ FIRE DEPARTMENT CONNECTION, PROVISION FOR TAMPER SWITCH WIRING FROM BUILDING TO HOT BOX. ALL PIPING SHALL BE DUCTILE IRON MECHANICAL JOINT WITH MEGA LUGS FROM THE CONNECTION AT THE MAIN TO A POINT OF AT LEAST 5-FT PAST THE OUTLET VALVE OF THE BACKFLOW PREVENTER. 2. PROVIDE SIGNAGE AT FDC PER CITY OF WINSTON-SALEM STANDARDS. 3" 90' BEND 4" 45UD 6" 90' BEND J 4" SAN SEWER SERVICE I NV: 922.30 GAS METER (SEE MEP PLAN) PROPOSED COMMUNITY CENTER EIP a 6" DIP SAN SERVICE (0 MIN SLOPE) 4" REMOTE FDC (2) 4" 45° BENDS 4" PVC SAN SI (1.04%" MIN SL 4" SAN SEWER SERVICE INV: 922.50 ---- PROPOSED 1,000 GPM GREASE TRAP (SEE MEP PLANS) 11.2 ' B _F G 6" DIP SAN SEWER SERVICE (0.60%" MIN SLOPE) DENNIS VASPORY & WIFE PATRICIA S. VASPORY TAX PIN 5885-23-3964 ZONING: RS-20 ■ CLEANOUT (TYP) ■ ■ �O 3" 22.5' BEND r f NATURAL GAS SERVICE (COORDINATE SIZE & ROUTING W/ PROVIDER) IRRIGATION WATER DOMESTIC WATER CONNECT TO EXISTING MANHOLE CIL INV: ±916.89 ADJUSTED RIM AS NECESSARY TO BE FLUSH W/ FINISHED GRADE FIELD VERIFY ELEVATION & LOCATION OF EXISTING WATER SERVICE PRIOR TO CONSTRUCTION (ADJUST AS REQUIRED TO AVOID CONFLICTS) DIRECTIONAL DRILL APPROXIMATELY 30 LF FOR EACH SERVICE & PROVIDE OPEN CUT FOR WET TAP (SOUTHBOUND LANE TO REMAIN OPEN AT ALL TIMES) 8"X6" TAPPING SLEEVE & VALVE 4" TAPPING SLEEVE & VALVE \ 4" DIP DOMESTIC WATER LINE UP TO METER (REDUCE TO 3" INSIDE METER VAULT) 6" FIRE PROTECTION RPZ IN ABOVE GROUND HEATED ENCLOSURE 600 PAIR COPPER 400 PAIR COPPER 25 PAIR COPPER 100 PAIR COPPER 3" DOMES IC ATER METER & V L 3" DOMESTV Z IN \ G� ABOVE GROUN ✓�� HEATED ENCL6\S E RELOCATE &RECONNECT EXISTING IRRIGATION LINE (FIELD \ \ \ VERIFY LOCATION AND SIZE). ►'II El C� TERMINATE LINE AT R/W. \ 6' �d o , \ \ , X1 ` \ r , M 00 0 Q z SCALE 1 "=30' 0 30' 60' CP#3 NCGS MONUMENT "FARMER" SITE LOCALIZATION POINT CGF=0.99994056 s 2 s c t f v C \ L \ \ \ 0 wbA , \ TOWN OF LEWISVILLE TAX PINS 5885-14-9288 & 5885-14-1447 AS COMBINED IN DB. 3529, PG. 1700-1703 �o ��J TACT 1 & 2 OF PB. 49. PG. 50 s� ZONING: RS-40 31.186AC EIR \ c \ / Oyq\\ �GT / I F / 3 400 4 a 6 a ? E s\ / 4 / o� TI SI SI Ai El / A W MAILBOX ' J GR VE Y ANA DUNN pR E A TAX PIN 5885-23-6944 ZONING: RS-20 IIr 3dwarchitects environmentsfoldife architecture planning interiors ix coliseum centre 815 coliseum centre drive uite 500 harlotte, north carolina 28217 704 379 1919 704 379 1920 'ww.adwarchitects.com EWISVILLE �OMMUNITY ENTER EWISVILLE, NC 00% CONSTRUCTION DOCUMENTS JTI LITY 'LAN )ATE 06.26.2020 'ROJECT NO 19033 ;EVISIONS 0 DATE DESCRIPTION: _ 07/13/20 ADDENDUM 1 _ 07/16/20 ADDENDUM 2 _ 07/21/20 ADDENDUM 3 _ 09/08/20 BIOCELL ADDED _ 10/05/20 EROSION CONTROL UPDATES _ 10/27/20 SITE SEWER UPDATES 11/16/20 PARKING LAYOUT SHIFT 0 04/26/21 TRANSFORMER SHIFT IIS DRAWING IS THE PROPERTY OF ADW ARCHITECTS, PA. AND ]ALL NOT BE REPRODUCED OR COPIED IN WHOLE OR IN PART. IT ]ALL NOT BE USED ON ANY OTHER PROJECT OR GIVEN TO ANY HER COMPANY OR AGENCY WITHOUT THE CONSENT OF ADW ZCHITECTS, PA. CAR% \ --t#Uz /�� qw . SEAL 38573 = >EAL HEET NUMBER