Loading...
HomeMy WebLinkAboutNCC214592_Site Plan or Location Map_20210816e ISOLATED WETLAND Ilk BUFFER AREA / LOT1 0 3.54 AC TI LOTS 1.75 AC - LOT 22 \ LOT 4 � 1. 02 Ac �Ac 2.25 AC � LOT 8 - � 3.41 AC LOT 9 100AC ' A _ I i J LOT 10 / 1.09 AC LOT 21 1.1oac LOT 11 / LOT 20 1.24 AC 1.10 AC I r LOT 1R2 1/ LOT 19 .16 AC / 1.10 AC i LOT 18 f I / 1.13 AC LOT 14 1.34 AC LOT 17 1.16 AC - LOT 23 ' LOT 16 19.30 AC LOT 15 I/ 2.42 AC 2.00 AC :2 ,. L # y ,■ ��'PrA Al r � � f r,� • a 1j MARGARET W. CATES DB 279/1665 PB 27/142 Yr } l �Pp �J - e• I 4 POWER UTILITIES EASEMENT ISOLATED _ WETLAND ISOLATED WETLAND BUFFER AREA Land Use Chart 3 4 Lot Number PIN Number Size (sf) Allowed Impervious (sf) Allowed Pervious (sf) Protected Forest (sf) Allowed Disturbance (sf) 1 9865-47-9609 152,468 32,139 120,330 0 152,468 2 9865-47-3699 75,225 6,953 68,272 0 75,225 3 9865-47-3422 55,254 10,964 44,290 0 55,254 4 9865-47-1489 44,623 6,909 37,714 0 44,623 5 9865-47-1616 76,199 7,572 31,487 37,139 39,059 6 9865-37-8840 153,972 5,818 74,127 74,027 79,945 8 9865-37-6495 148,593 6,535 71,405 70,653 77,940 9 9865-37-8392 43,436 7,644 35,792 0 43,436 10 9865-47-0214 47,307 6,909 40,398 0 47,307 11 9865-47-1156 54,027 10,861 43,166 0 54,027 12 9865-37-9042 50,581 6,929 43,652 0 50,581 13 9865-36-8884 46,148 7,637 38,511 0 46,148 14 9865-36-7838 58,511 6,155 52,356 0 58,511 15 9865-36-6666 87,262 5,848 57,746 23,668 63,594 16 9865-46-0685 105,230 9,272 95,957 0 105,230 17 9865-46-2823 50,507 6,900 43,608 0 50,507 18 9865-46-3916 49,030 6,911 42,119 0 49,030 19 9865-47-3098 48,133 6,914 41,218 0 48,133 20 9865-47-4270 48,000 6,907 41,093 0 48,000 21 9865-47-5363 48,000 6,907 41,093 0 48,000 22 9865-47-7501 98,089 11,817 86,273 0 98,089 ***Lots 1-22 are part of current LDP for infrastructure construction only. All other disturbances on these lots will require amendments or individual separate LDP applications. Lots 23-29 will require separate and individual LDP applications. 23 9865-46-8852 840,471 20,000 175,000 645,471 195,000 24 9865-45-7847 2,656,846 65,000 557,281 2,034,565 622,281 25 9865-44-7143 597,028 0 0 597,028 0 26 9865-54-3742 1,063,555 0 0 1,063,555 0 27 9865-65-1297 268,399 16,500 119,931 131,962 136,437 28 9865-65-7637 68,862 8,000 60,862 0 68,862 29 9865-65-8874 59,471 4,500 41,601 13,370 46,101 Total 7,095,228 298,500 2,105,290 4,691,439 2,403,789 LOT 29 1.37 AC f+� . LOT 28 � � • �- 1.58 AC f - qW Jim LOT 27 6.16AC P� d `0�' -MLA OF J06. TULIP TREE DRIVE 0 oIT z LAND USE SUMMARY 0 LOT 1-22: ROOF AND DRIVEWAY = 94,500 SF (2.17 AC) 4,500 SF PER LOT ROAD = 90,000 SF (2.07 AC) LANDSCAPING PERVIOUS = 1,062,149 SF (24.38 AC) BUFFER AREA = 23,283 SF (0.53 AC) UTILITIES EASEMENT = 88,459 SF (2.03 AC) CONSERVATION AREA = 182,204 SF (4.18 AC) TOTAL = 1,540,596 SF (35.37 AC) BUA PERCENTAGE = 12% LOT 23: ROOF = 10,000 SF (0.23 AC) ROAD OR DRIVEWAY = 10,000 SF (0.23 AC) LANDSCAPING PERVIOUS = 175,000 SF (4.02 AC) CONSERVATION AREA = 645,471 SF (14.82 AC) TOTAL = 840,471 SF (19.29 AC) LOT 24: ROOF = 15,000 SF (0.34 AC) ROAD OR DRIVEWAY = 50,000 SF (1.15 AC) LANDSCAPING PERVIOUS = 355,600 SF (8.16 AC) BUFFER AREA = 161,771 SF (3.71 AC) UTILITIES EASEMENT = 201,681 SF (4.63 AC) ISOLATED WETLAND = 11,586 SF (0.27 AC) CONSERVATION AREA = 1,861,208 SF (42.73 AC) TOTAL = 2,656,846 SF (60.99 AC) BUA PERCENTAGE = 5% LOT 25: BUFFER AREA = 52,066 SF (1.20 AC) CONSERVATION AREA = 544,962 SF (12.51 AC) TOTAL = 597,028 SF (13.71 AC) LOT 26: BUFFER AREA = 232,052 SF (5.33 AC) CONSERVATION AREA = 816,926 SF (18.75 AC) ISOLATED WETLAND = 14,577 SF (0.33 AC) TOTAL = 1,063,555 SF (24.42 AC) LOT 27: ROOF = 7,000 SF (0.16 AC) ROAD OR DRIVEWAY = 9,500 SF (0.22 AC) LANDSCAPING PERVIOUS = 119,937 SF (2.75 AC) BUFFER AREA = 103,367 SF (2.37 AC) CONSERVATION AREA = 28,595 SF (0.66 AC) TOTAL = 268,399 SF (6.16 AC) LOT 28: ROOF = 3,500 SF (0.08 AC) ROAD OR DRIVEWAY = 4,500 SF (0.10 AC) LANDSCAPING PERVIOUS = 57,655 SF (1.32 AC) UTILITIES EASEMENT = 3,207 SF (0.07 AC) TOTAL = 68,862 SF (1.58 AC) LOT 29: ROOF = 3,500 SF (0.08 AC) ROAD OR DRIVEWAY = 1,000 SF (0.02 AC) LANDSCAPING PERVIOUS = 11,218 SF (0.26 AC) UTILITIES EASEMENT = 30,383 SF (0.70 AC) CONSERVATION AREA = 13,370 SF (0.31 AC) TOTAL = 59,471 SF (1.37 AC) TOTAL = 7,095,228 SF (162.88 AC) BUA PERCENTAGE = 4% NOTE: LOTS 25-29 ACREAGES HAVE NOT BEEN SURVEY. THE LOT SIZE ON LAND USE CHART AND THE PLAN l ARE ONLY AN ESTIMATE LOT SIZE. Pre Development Hydrologic Fate: Suface Type RO IF ET Cover Area (sf) Per- centage Undistubed Woods 5% 45% 50% 6,501,679 91.63% Existing wooded and buffer area Disturbed Trees 10% 40% 50% 323,730 4.56% Existing power line and utility easement (Other pervious for SNAP) Disturbed Lawns 1 15% 1 40% F 45% 218,656 3.08% Existing manageable pervious areas (Other pervious for SNAP) Open Water/BMP 1 100% 1 0% 1 0% 26,163 0.37% Existing isolated wetland areas (Protected forest for SNAP) Impermeable Surface 70% 15% 15% 20,000 0.28% Existing gravel driveway Impermeable Surface 2 95% 0% 5% 5,000 0.07% Existing roof Total 7,095,228 100.00% Post Development Hydrologic Fate: Suface Type RO IF ET Cover Area (sf) Per - centage Undistubed Woods 5% 45% 50% 4,665,276 65.75% Existing wooded and buffer areas (Conservation areas, Protected forest for SNAP) Disturbed Trees 1 10% 1 40% 1 50% 323,730 4.56 / Existing power line and utility easement (Other pervious for SNAP) Disturbed Lawns 1 15% 1 40% 1 45% 640,335 9.02% Proposed manageable pervious areas within ROW and lot 24 backyard areas (Other pervious for SNAP) Lawn - Amended Soil 1 7% 1 45% 1 48% 1,141,224 16.08% Proposed backyard areas for lot 1-22 and lot 25 (Other pervious for SNAP) Open Water/BMP 1 100% 0% 0% 1 26,163 0.37% Existing isolated wetland areas (Conservation areas, Protected forest for SNAP) Impermeable Surface 2 1 95% 1 0% 5% 298,500 T 4.21 / Proposed concrete road, concrete driveway, and roof Pre -Project Post -Project Post -Project Nutrient Export Summary Whole Site Whole Site Whole Site with Conditions without SCMs SCMs Post -Project Post Project SCM-Treated Untreated Area Area 0.0% 4.2% Percent Impervious (for runoff calculation) (%) 0.4% 4.2% 4.2% Percent Built -Upon Area (BUA) (%) 0.4% 4.2% 4.2% 0.0% 4.2% Annual Runoff Volume (ft3/yr) 1,352,765 2,235,397 2,235,397 0 2,235,397 Annual Runoff % Change (relative to pre-D) 0% 65% 65% Total Nitrogen EMC (mg/L) 1.11 1.42 1.42 0.00 1.42 Total Nitrogen Load Leaving Site (lb/yr) 94.18 198.54 198.49 0.00 198.49 Total Nitrogen Loading Rate (Ib/ac/yr) 0.58 1.22 1.22 0.00 1.22 Total Nitrogen % Change (relative to pre-D) 0% 111% 111% Total Phosphorus EMC (mg/L) 0.12 0.29 0.29 0.00 0.29 Total Phosphorus Load Leaving Site (lb/yr) 10.25 39.99 39.98 0.00 39.98 Total Phosphorus Loading Rate (Ib/ac/yr) 0.06 0.25 0.25 0.00 0.25 Total Phosphorus % Change (relative to pre-D) 1 0% 1 290% 1 290% ■ PROPOSED ROAD/DRIVEWAY ' EXISTING UTILITY AND POWER EASEMENT AREAS J ®UNDISTURBED WOODS/PROTECTED FOREST, BUFFER, AND ISOLATED WETLAND AREAS (CONSERVATION AREA) ALLOWED AREAS FOR ROOF, DRIVEWAY, AND YARD/SEPTIC (ALLOWED DISTURBANCE AREA) III PROPOSED SEPTIC AREAS Know what's below. Call before you dig. GRAPHIC SCALE 100 0 50 100 200 400 (IN FEET) 1 inch = 200 ft. I -I o O � �4 o E N H 0 U J zn Z U W UA(j W �, M �� Wz l9 �Ln ❑ N W U U�Z� M s ON o0 0 w� �N 101i/1 Ln ti ti ti ti c c c c W 0 0 0 0 C z w w H C w w w U� VJ CA H O a W W O 2 r h � c � O c � Q U � H Q C3 PROJECT #: 17-013 REVIEW PROJECT #: Z\_ZX_-� SHEET #: C-1.4