HomeMy WebLinkAboutNCC214592_Site Plan or Location Map_20210816e
ISOLATED
WETLAND
Ilk
BUFFER AREA
/ LOT1
0 3.54 AC
TI
LOTS
1.75 AC - LOT 22
\ LOT 4 � 1. 02 Ac �Ac 2.25 AC
�
LOT 8 - �
3.41 AC LOT 9
100AC ' A _ I
i
J LOT 10 /
1.09 AC LOT 21
1.1oac
LOT 11 / LOT 20
1.24 AC 1.10 AC
I r
LOT 1R2
1/ LOT 19
.16 AC /
1.10 AC
i
LOT 18
f I / 1.13 AC
LOT 14
1.34 AC
LOT 17
1.16 AC
- LOT 23
' LOT 16 19.30 AC
LOT 15 I/ 2.42 AC
2.00 AC
:2 ,.
L
# y
,■ ��'PrA
Al
r � �
f
r,�
• a
1j
MARGARET W. CATES
DB 279/1665
PB 27/142
Yr
} l
�Pp
�J
- e•
I
4
POWER
UTILITIES
EASEMENT
ISOLATED _
WETLAND
ISOLATED
WETLAND
BUFFER AREA
Land Use Chart 3 4
Lot
Number
PIN
Number
Size
(sf)
Allowed
Impervious (sf)
Allowed
Pervious (sf)
Protected
Forest (sf)
Allowed
Disturbance (sf)
1
9865-47-9609
152,468
32,139
120,330
0
152,468
2
9865-47-3699
75,225
6,953
68,272
0
75,225
3
9865-47-3422
55,254
10,964
44,290
0
55,254
4
9865-47-1489
44,623
6,909
37,714
0
44,623
5
9865-47-1616
76,199
7,572
31,487
37,139
39,059
6
9865-37-8840
153,972
5,818
74,127
74,027
79,945
8
9865-37-6495
148,593
6,535
71,405
70,653
77,940
9
9865-37-8392
43,436
7,644
35,792
0
43,436
10
9865-47-0214
47,307
6,909
40,398
0
47,307
11
9865-47-1156
54,027
10,861
43,166
0
54,027
12
9865-37-9042
50,581
6,929
43,652
0
50,581
13
9865-36-8884
46,148
7,637
38,511
0
46,148
14
9865-36-7838
58,511
6,155
52,356
0
58,511
15
9865-36-6666
87,262
5,848
57,746
23,668
63,594
16
9865-46-0685
105,230
9,272
95,957
0
105,230
17
9865-46-2823
50,507
6,900
43,608
0
50,507
18
9865-46-3916
49,030
6,911
42,119
0
49,030
19
9865-47-3098
48,133
6,914
41,218
0
48,133
20
9865-47-4270
48,000
6,907
41,093
0
48,000
21
9865-47-5363
48,000
6,907
41,093
0
48,000
22
9865-47-7501
98,089
11,817
86,273
0
98,089
***Lots 1-22 are part of current LDP for infrastructure construction only. All other disturbances on these lots
will require amendments or individual separate LDP applications. Lots 23-29 will require separate and
individual LDP applications.
23
9865-46-8852
840,471
20,000
175,000
645,471
195,000
24
9865-45-7847
2,656,846
65,000
557,281
2,034,565
622,281
25
9865-44-7143
597,028
0
0
597,028
0
26
9865-54-3742
1,063,555
0
0
1,063,555
0
27
9865-65-1297
268,399
16,500
119,931
131,962
136,437
28
9865-65-7637
68,862
8,000
60,862
0
68,862
29
9865-65-8874
59,471
4,500
41,601
13,370
46,101
Total
7,095,228
298,500
2,105,290
4,691,439
2,403,789
LOT 29
1.37 AC
f+� .
LOT 28 � � • �-
1.58 AC f
- qW
Jim
LOT 27
6.16AC P�
d
`0�'
-MLA
OF J06.
TULIP TREE DRIVE
0
oIT
z
LAND USE SUMMARY 0
LOT 1-22:
ROOF AND DRIVEWAY =
94,500 SF (2.17 AC)
4,500 SF PER LOT
ROAD =
90,000 SF (2.07 AC)
LANDSCAPING PERVIOUS =
1,062,149 SF (24.38 AC)
BUFFER AREA =
23,283 SF (0.53 AC)
UTILITIES EASEMENT =
88,459 SF (2.03 AC)
CONSERVATION AREA =
182,204 SF (4.18 AC)
TOTAL = 1,540,596 SF (35.37 AC)
BUA PERCENTAGE = 12%
LOT 23:
ROOF =
10,000 SF (0.23 AC)
ROAD OR DRIVEWAY =
10,000 SF (0.23 AC)
LANDSCAPING PERVIOUS =
175,000 SF (4.02 AC)
CONSERVATION AREA =
645,471 SF (14.82 AC)
TOTAL = 840,471 SF (19.29 AC)
LOT 24:
ROOF =
15,000 SF (0.34 AC)
ROAD OR DRIVEWAY =
50,000 SF (1.15 AC)
LANDSCAPING PERVIOUS =
355,600 SF (8.16 AC)
BUFFER AREA =
161,771 SF (3.71 AC)
UTILITIES EASEMENT =
201,681 SF (4.63 AC)
ISOLATED WETLAND =
11,586 SF (0.27 AC)
CONSERVATION AREA =
1,861,208 SF (42.73 AC)
TOTAL = 2,656,846 SF (60.99 AC)
BUA PERCENTAGE = 5%
LOT 25:
BUFFER AREA =
52,066 SF (1.20 AC)
CONSERVATION AREA =
544,962 SF (12.51 AC)
TOTAL = 597,028 SF (13.71 AC)
LOT 26:
BUFFER AREA =
232,052 SF (5.33 AC)
CONSERVATION AREA =
816,926 SF (18.75 AC)
ISOLATED WETLAND =
14,577 SF (0.33 AC)
TOTAL = 1,063,555 SF (24.42 AC)
LOT 27:
ROOF =
7,000 SF (0.16 AC)
ROAD OR DRIVEWAY =
9,500 SF (0.22 AC)
LANDSCAPING PERVIOUS =
119,937 SF (2.75 AC)
BUFFER AREA =
103,367 SF (2.37 AC)
CONSERVATION AREA =
28,595 SF (0.66 AC)
TOTAL = 268,399 SF (6.16 AC)
LOT 28:
ROOF =
3,500 SF (0.08 AC)
ROAD OR DRIVEWAY =
4,500 SF (0.10 AC)
LANDSCAPING PERVIOUS =
57,655 SF (1.32 AC)
UTILITIES EASEMENT =
3,207 SF (0.07 AC)
TOTAL = 68,862 SF (1.58 AC)
LOT 29:
ROOF =
3,500 SF (0.08 AC)
ROAD OR DRIVEWAY =
1,000 SF (0.02 AC)
LANDSCAPING PERVIOUS =
11,218 SF (0.26 AC)
UTILITIES EASEMENT =
30,383 SF (0.70 AC)
CONSERVATION AREA =
13,370 SF (0.31 AC)
TOTAL = 59,471 SF (1.37 AC)
TOTAL = 7,095,228 SF (162.88 AC)
BUA PERCENTAGE = 4%
NOTE: LOTS 25-29 ACREAGES HAVE NOT BEEN SURVEY. THE LOT SIZE ON LAND USE CHART AND THE PLAN
l ARE ONLY AN ESTIMATE LOT SIZE.
Pre Development Hydrologic Fate:
Suface Type
RO
IF
ET
Cover
Area (sf)
Per-
centage
Undistubed Woods
5%
45%
50%
6,501,679
91.63%
Existing wooded and buffer area
Disturbed Trees
10%
40%
50%
323,730
4.56%
Existing power line and utility easement (Other pervious for SNAP)
Disturbed Lawns
1 15%
1 40%
F 45%
218,656
3.08%
Existing manageable pervious areas (Other pervious for SNAP)
Open Water/BMP
1 100%
1 0%
1 0%
26,163
0.37%
Existing isolated wetland areas (Protected forest for SNAP)
Impermeable Surface
70%
15%
15%
20,000
0.28%
Existing gravel driveway
Impermeable Surface 2
95%
0%
5%
5,000
0.07%
Existing roof
Total 7,095,228 100.00%
Post Development Hydrologic Fate:
Suface Type
RO
IF
ET
Cover
Area (sf)
Per -
centage
Undistubed Woods
5%
45%
50%
4,665,276
65.75%
Existing wooded and buffer areas (Conservation areas, Protected forest for SNAP)
Disturbed Trees
1 10%
1 40%
1 50%
323,730
4.56 /
Existing power line and utility easement (Other pervious for SNAP)
Disturbed Lawns
1 15%
1 40%
1 45%
640,335
9.02%
Proposed manageable pervious areas within ROW and lot 24 backyard areas (Other pervious for SNAP)
Lawn - Amended Soil
1 7%
1 45%
1 48%
1,141,224
16.08%
Proposed backyard areas for lot 1-22 and lot 25 (Other pervious for SNAP)
Open Water/BMP
1 100%
0%
0%
1 26,163
0.37%
Existing isolated wetland areas (Conservation areas, Protected forest for SNAP)
Impermeable Surface 2
1 95%
1 0%
5%
298,500
T 4.21 /
Proposed concrete road, concrete driveway, and roof
Pre -Project Post -Project Post -Project
Nutrient Export Summary Whole Site Whole Site Whole Site with
Conditions without SCMs SCMs
Post -Project
Post Project
SCM-Treated
Untreated Area
Area
0.0% 4.2%
Percent Impervious (for runoff calculation) (%)
0.4%
4.2%
4.2%
Percent Built -Upon Area (BUA) (%)
0.4%
4.2%
4.2%
0.0%
4.2%
Annual Runoff Volume (ft3/yr)
1,352,765
2,235,397
2,235,397
0
2,235,397
Annual Runoff % Change (relative to pre-D)
0%
65%
65%
Total Nitrogen EMC (mg/L)
1.11
1.42
1.42
0.00
1.42
Total Nitrogen Load Leaving Site (lb/yr)
94.18
198.54
198.49
0.00
198.49
Total Nitrogen Loading Rate (Ib/ac/yr)
0.58
1.22
1.22
0.00
1.22
Total Nitrogen % Change (relative to pre-D)
0%
111%
111%
Total Phosphorus EMC (mg/L)
0.12
0.29
0.29
0.00
0.29
Total Phosphorus Load Leaving Site (lb/yr)
10.25
39.99
39.98
0.00
39.98
Total Phosphorus Loading Rate (Ib/ac/yr)
0.06
0.25
0.25
0.00
0.25
Total Phosphorus % Change (relative to pre-D)
1 0%
1 290%
1 290%
■ PROPOSED ROAD/DRIVEWAY
' EXISTING UTILITY AND POWER EASEMENT AREAS
J ®UNDISTURBED WOODS/PROTECTED FOREST, BUFFER, AND ISOLATED WETLAND AREAS
(CONSERVATION AREA)
ALLOWED AREAS FOR ROOF, DRIVEWAY, AND YARD/SEPTIC (ALLOWED DISTURBANCE AREA)
III PROPOSED SEPTIC AREAS
Know what's below.
Call before you dig.
GRAPHIC SCALE
100 0 50 100 200 400
(IN FEET)
1 inch = 200 ft.
I -I
o
O
� �4
o
E
N
H
0 U
J
zn
Z
U
W
UA(j W
�, M
��
Wz
l9
�Ln
❑
N
W
U
U�Z�
M s ON
o0
0
w� �N
101i/1
Ln
ti ti ti ti
c c c c W
0 0 0 0
C
z w
w
H
C
w w w
U�
VJ CA
H O
a
W
W
O
2
r h �
c
� O c
� Q
U
� H Q
C3 PROJECT #:
17-013
REVIEW PROJECT #:
Z\_ZX_-�
SHEET #:
C-1.4