Loading...
HomeMy WebLinkAboutWQCS00366_Compliance Evaluation Inspection_20210812Compliance Inspection Report Permit: WQCS00366 Effective: 10/01/17 Expiration: 09/30/25 Owner : Carolina Water Service Inc of North Carolina SOC: Effective: Expiration: Facility: White Oak Estates Collection System County: Onslow Region: Wilmington Contact Person: Tony Konsul Directions to Facility: System Classifications: CS2, Primary ORC: Gregory D Spillman Secondary ORC(s): On -Site Representative(s): On -site representative Related Permits: Title: Regional Manager Certification: 1005812 Gregory D Spillman Phone: 704-319-0523 Phone: NC0031577 Carolina Water Service Inc of North Carolina - White Oak Estates WWTP Inspection Date: 08/12/2021 Entry Time 09:OOAM Exit Time: 11:OOAM Primary Inspector: Brian S West Phone: 910-796-7341 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: ❑ Compliant Not Compliant Question Areas: ▪ Miscellaneous Questions II Capital Improvement Plan ▪ Inspections ▪ Lines (See attachment summary) ▪ General ▪ Map ▪ Spill Response Plan ▪ Pump Stations ▪ Sewer & FOG Ordinances ▪ Reporting Requirements ▪ Spills Page 1 of 7 Permit: WQCS00366 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 08/12/2021 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: Routine compliance inspection with Greg Spillman. Please see comments under each section of the report. Please inform this office when alarm systems and pump #2 are functional at PS #1. System status will be deemed compliant upon completion of these items verfied by follow-up site visit Page 2 of 7 Permit: WQCS00366 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 08/12/2021 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine General Is there a properly designated primary ORC and at least one back-up of proper grade? Are logs being reviewed by the system management or owner on a regular basis? # What is that frequency? # Are there any issues being addressed currently or any in the planning stages? Is there a specific pump failure plan available for all pump stations? Does plan indicate if pump parts/new pumps are in spare parts/equipment inventory? Are new/significantly upgraded pump stations equipped with anti -corrosion materials? Does the permittee have a copy of their permit? # Is permit expiring within the next 6 months? If Yes, has the Permittee applied for renewal? Comment: Need to designate properly cettified backup operator Sewer and FOG Ordinances Is Sewer Use Ordinance (SUO) or other Legal Authority available? Does it appear that the Sewer Use Ordinance is enforced? Is there a Grease Control Program that legally requires grease control devices? What is the standard grease trap cleaning requirement in the FOG ordinance? Is Grease Control Program enforced via periodic inspections/records review? Is action taken against violators? # Have satellite systems adopted an equivalent or more stringent ordinance? Is grease/sewer education program documented with req'd customer distribution? # Are other types of education tools used like websites, booths, special meetings, etc? If Yes, what are they? (This can reduce mailing to annual.) Comment: Documented FOG factsheet mailings to customers 2/year; last done 7/21/21. Several grease traps at strip mall and school are inspected by operators routinely Yes No NA NE ▪ • • ❑ ❑• designate backup operator • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ • ❑ Capital Improvement Plan Has a Capital (CIP) or System Improvement Plan been developed and adopted? Is it designated for wastewater only or does it have a dedicated section? Does CIP cover three to five year period of earmarked improvements? Does CIP include description of project area? Does CIP include description of existing facilities? Does CIP include known deficiencies? Does CIP include forecasted future needs? Yes No NA NE • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ Comment: No current CIP on hand. Utility is currently drafting a 5 year CIP that will inlcude line camera work to address significant I&I issues in the system Page 3 of 7 Permit: WQCS00366 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 08/12/2021 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Map Yes No NA NE Is there a overall sewer system map? • ❑ ❑ ❑ Does the map include: Pipe Type (GS/FM) • ❑ ❑ ❑ Pipe sizes • ❑ ❑ ❑ Pipe materials (PVC, DIP, etc) ❑ • ❑ ❑ Pipe location • ❑ ❑ ❑ Flow direction • ❑ ❑ ❑ Approximate pipe age ❑ • ❑ ❑ Pump station ID, location and capacity • ❑ ❑ ❑ # Force main air release valve location & type ❑ ❑ • ❑ # Location of satellite connections ❑ ❑ • ❑ Is the map being updated for changes/additions within 1 year of activation? ❑ ❑ • ❑ Comment: Map covers all areas of CS and appears up to date. There is one area in the subdivision planned for future development at end of Broadleaf Dr Reporting Requirements Yes No NA NE # Have there been any sewer spills in the past 3 years? ❑ • ❑ ❑ If Yes, were they reported to the Division if meeting the reportable criteria? ❑ ❑ • ❑ If applicable, is there documentation of press releases and public notices issued? ❑ ❑ • ❑ Is an Annual Wastewater Performance Report being filed with the Division, if required? ❑ ❑ • ❑ Is the report being made available to all its sewer customers? ❑ ❑ • ❑ # How is it being made available? Comment: Inspections Yes No NA NE Are adequate maintenance records maintained? • ❑ ❑ ❑ Are pump stations being inspected at the required frequency? • ❑ ❑ ❑ # Is at least one complete functionality test conducted weekly per pump station? • ❑ ❑ ❑ Is there a system or plan in place to observe the entire system annually? • ❑ ❑ ❑ Is the annual inspection documented? ❑ • ❑ ❑ # Does the system have any high -priority lines/locations? • ❑ ❑ ❑ Are inspections of HPL documented at least every 6 months? • El El El Are new lines being added to the HPL list when found or created? ❑ ❑ • ❑ Comment: Operators keep electroninc records on (Pads to include routine inspections and maintenance Spill Response Action Plan Is a Spill Response Action Plan available? Yes No NA NE • ❑ ❑ ❑ Page4of7 Permit: WQCS00366 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 08/12/2021 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Is a Spill Response Action Plan available for all personnel? Does the plan include: 24-hour contact numbers Response time Equipment list and spare parts inventory Access to cleaning equipment Access to construction crews, contractors, and/or engineers Source of emergency funds Site sanitation and cleanup materials Post-overflow/spill assessment Does the Permittee appear to respond within 2 hours of first knowledge of a spill? Comment: Spills Is system free of known points of bypass? If No, describe type of bypass and location Are all spills or sewer related issues/complaints documented? # Are there repeated overflows/problems (2 or more in 12 months) at same location? # If Yes, is there a corrective action plan? Comment: No reported SSOs since 2017 Lines/Right-of-Ways/Aerial Lines Please list the Lines/Right of Ways/Aerial Lines Inspected: Right of ways to PSs visited are well maintained. High priority line (FM through undeveloped area Braodleaf Drive) is inspected every 6 months Are right-of-ways/easements maintained for full width for access by staff/equipment? If No, give details on temporary access: Is maintenance documented? Are gravity sewer cleaning records available? Has at least 10% of lines older than 5 yrs been cleaned annually? Were all areas/lines inspected free of issues? Comment: Most recent cleaning White Oak Blvd during 5/21 documented Pump Stations Please list the Pump Stations Inspected: PS #1 (96 White Oak Blvd), PS #2 (164 Balsam Ct) • ❑ ❑ ❑ • ▪ ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ▪ ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • Yes No NA NE # Number of duplex or larger pump stations in system 5 # Number of vacuum stations in system 0 # Number of simplex pump stations in system 0 # Number of simplex pump stations in system serving more than one building 0 Page5of7 Permit: WQCS00366 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 08/12/2021 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine How many pump/vacuum stations have: # A two-way "auto polling" communication system (SCADA) installed? # A simple one-way telemetry/communication system (auto -dialer) installed? For pump stations inspected: Are they secure with restricted access? Were they free of by-pass structures/pipes? Were wet wells free of excessive grease/debris? # Do they all have telemetry installed? Is the communication system functional? Is a 24-hour notification sign posted ? Does the sign include: Owner Name? Pump station identifier? # Address? Instructions for notification? 24-hour emergency contact numbers? Are audio and visual alarms present? Are audio and visual alarms operable? # Is there a backup generator or bypass pump connected? If tested during inspection, did it function properly? Is the back-up system tested at least bi-annually under normal operating conditions? # Does it have a dedicated connection for a portable generator? # Is the owner relying on portable units in the event of a power outage? # If Yes, is there a distribution plan? If Yes, what resources (Units/Staff/Vehicles/etc) are included in Plan? # Does Permittee have the approved percentage of replacement simplex pumps? Is recordkeeping of pump station inspection and maintenance program adequate? Do pump station logs include at a minimum: Inside and outside cleaning and debris removal? Inspecting and exercising all valves? Inspecting and lubricating pumps and other equipment? Inspecting alarms, telemetry and auxiliary equipment? 5 • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ ❑ • ❑ ❑ • ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page6of7 Permit: WQCS00366 Owner - Facility: Carolina Water Service Inc of North Carolina Inspection Date: 08/12/2021 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Comment: Company protocol requires operator documentation (recorded on !Pad) that all required routine maintenance activities are performed. One portable generator is available for connection to all PS's. Unit is tested weekly and under contract for quarterly PM. PS#1- Neither telemetry nor on -site A/V alarms were functional during visit. Pump #2 is currenity out of service. Due to the age of the pump, service is not optional and a new pump is on order. Please inform this office when alarm systems are functional and new pump has been installed. Flooding in this area has caused some erosion around the station well which needs to be addressed with fill/stabilization. PS#2- Station is also older but all systems appeared functional during the visit. The control panel wooden supports are showing rot at the base and should be monitored for replacement as needed Page 7 of 7