Loading...
HomeMy WebLinkAboutNCG551387_Inspection 08-12-2021_20210812United States Environmental Protection Agency E PA Washington D.0 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction 1 21IIIIII Code NPDES yrlmo/day Inspection IN I 2 iF I 31 NCG551387 ! 1 i 121 21/08/12 117 Type 181 r, l III' Inspector Fac Type 19 l G I 2011 IIIIIIIIIII IIIIIII II IIIII IIIII11 r6 Inspection 67 Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved----------------- 73 74 75I I I I I I I180 l Section B: Facility Data Name and Location of Facility Inspected (For industrial Users discharging to POTW, also include POTW name and NPDES permit Number) 3714 Esther Drive 3714 Esther Dr Durham NC 27703 Entry TimelDate 09:00AM 21/08/12 Permit Effective Date 12/08/01 Exit Time/Date 10:30AM 21/08/12 Permit Expiration Date 13/07/31 Name(s) of Onsite Representative(s)ITitles(s)1Phone and Fax Number(s) 1// Other Facility Data Name, Address of Responsible Officialftle/Phone and Fax Number Charles L Gibbs,PO Box 1246 Durham NC 27702Contacted /11 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) gi Other Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) Jane qd.,,,,_ and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Bernard DWR/Non Discharge Compliance Unit/919-791-4200/ ff---12—LA-..,oL,L,c-I 8 i 13 \ G.._ 1 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yrlmolday 31 NCG551387 111 121 21/08/12 117 Inspection Type 181„I (Cont.) 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) On August 12, 2021, Jane Bernard from the Raleigh Regional Office visited your single-family residence (SFR) wastewater treatment system to complete a follow-up/technical assistance inspection regarding the above violations. Your assistance during the inspection was greatly appreciated. As a result of the August 12, 2021 follow-up/technical assistance inspection meeting the following items have been addressed and or corrected. 1. The septic tank was pumped on August 8, 2021. 2. There were small pieces of tablets in the chlorinator, however there we not any additional tablets on site. 3. The broken chlorinator sleeve has been "duct tape" together. This is just a temporary fix until the replacement sleeve is received. 4. Permit fees are current. During the August 12, 2021 follow-up/technical assistance inspection, several additional items were discussed that will need to be addressed. a. Mr. Gibbs offered that the washing machine bypasses the septic tank. It was determined that he would have the discharge from the washing machine moved to the front of the septic tank and a receipt stating that the connection was moved will be submitted to the RRO. b. The chlorine contact chamber/vault was at ground level and broken allowing waste to surface. Mr. Gibbs will also have that repaired as needed. Page# 2 Permit: NCG551387 Inspection Date: 08/12/2021 Owner - Facility: 3714 Esther Drive Inspection Type: Technical Assistance Other Comment: Yes No NA NE Page# 3