HomeMy WebLinkAbout20130573 Ver 1_More Info Letter_20130701July 1, 2013
CERTIFIED MAIL: 7012 2920 0000 3656 1141
RETURN RECEIPT REQUESTED
Reliable Tank Line LLC
Quality Oil Company LLC
Attn: Ernie Rhymer
1540 Silas Creek Parkway
Winston -Salem NC 27127
Subject: REQUEST FOR ADDITIONAL INFORMATION
Quality Mart Gas Station
Dear Mr. Rhymer:
John E. Skvarla, III
Secretary
DWQ # 13 -0573
DWQ #13 -0574
Ashe County
On May 31, 2013, the Division of Water Quality (Division) received your applications dated March 26, 2013,
requesting a 401 Water Quality Certification from the Division for your project. The Division has determined
that your applications are incomplete and cannot be processed. The applications are on -hold until all of the
following information is received:
1. Per Condition 6 of GC 3890, all work must be done "in the dry ". Therefore, dewatering methods will
be necessary to temporarily dewater the stream channels during pipe installation. Please provide
construction drawings /plans that clearly show the location /limits of the temporary impacts from
dewatering and provide revised impact tables which notes these temporary impact lengths.
2. Please clarify whether the Division of Energy, Mineral and Land Resources will require riprap within
any stream channels as part of the Erosion & Sedimentation Control Plan approval. If riprap is
required, please enumerate and clearly label the temporary and permanent impacts on the site plan
and submit a channel restoration detail. Riprap must be located below the stream bed elevation.
3. It appears that the StormTech chambers are being proposed to support an underground infiltration system.
This is an acceptable approach to managing the stormwater from this site. However, the Division will need
additional information to review the system and determine if state design standards have been met. Please
provide the following:
North Carolina Division of Water Quality, Winston -Salem Regional Office
Location: 585 Waughtown St. Winston - Salem, North Carolina 27107 One
Phone: 336 - 771 -5000 \ FAX 336 - 771 -4630 \ Customer Service: 1- 877 - 623 -6748 NOrthCarOhna
Internet: www.ncwaterquality.org Naturally
An Equal Opportunity \ Affirmative Action Employer
Reliable Tank Line LLC
DWQ# 13 -0573
Quality Gas Station
DWQ #13 -0574
June 20, 2013
Page 2 of 3
a. Full -sized plan sheets showing the entire site with its storm drainage system, including every inlet,
outlet and conveyance device. Please show how stormwater management requirements have been
met at every proposed outlet location.
b. Please provide an Infiltration System Supplement Form with all required items for the StormTech
system (see http: / /portal.ncdenr.org /web /wq /ws /su /bmp- manual).
c. Sealed, signed and dated supporting calculations for each BMP.
d. An original signed and notarized O &M Agreement form. Sample O &M forms are available at:
http: / /Portal.ncdenr.org /web /wq /ws /su /bmp- manual.
e. A soils report that states the level of the SHWT elevation based on a boring within the footprint of each
of the proposed BMPs.
Pursuant to Title 15A NCAC 02H .0502(e), the applicant shall furnish all of the above requested information
for the proper consideration of the application. If all of the requested information is not received in writing
within 30 calendar days of receipt of this letter, the Division will be unable to approve the application and it
will be returned. The return of this project will necessitate reapplication to the Division for approval,
including a complete application package and the appropriate fee.
Please respond in writing within 30 calendar days of receipt of this letter by sending two copies of all of the
above requested information to the Wetlands, Buffers, Stormwater — Compliance and Permitting (Webscape)
Unit, 1650 Mail Service Center, Raleigh, NC 27699 -1650.
Please be aware that you have no authorization under the Water Quality Certification Rules for this activity
and any work done within waters of the state may be a violation of North Carolina General Statutes and
Administrative Code.
Please contact Sue Homewood at 336 - 771 -4964 or sue.homewood @ncdenr.gov if you have any questions or
concerns.
Sincerely,
Sue Homewood
DWQ Winston -Salem Regional Office
Reliable Tank Line LLC
DWQ# 13 -0573
Quality Gas Station
DWQ #13 -0574
June 20, 2013
Page 3 of 3
cc: Derek Goddard, BREC (via email)
Tasha McCormick, USACE Asheville Regulatory Field Office (via email)
DWQ WSRO 401 files
DWQ Webscape Unit