Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
510107_Inspection_20210422
Division of Water Resources Facility Number ©- Go�,r 0 Division of Soil and Water Conservation Other Agency Type of Visit: JZ) Compliance Inspection U Operation Review U Structure Evaluation U Technical Assistance Reason for Visit: Aoutine 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access Date of Visit: Arrival Time: fleparture Time: County:Jer S Region:Q t� Farm Name: ,V I -S-. L-e--e— 4,..v7'i Owner Email: Owner Name: C ev� �J t L—,e tr Phone: Mailing Address: !7 Physical Address: _ V n 5 y Ct Facility Contact: Title: Phone: ai 9 i 5 = 0 Onsite Representative: Integrator: 6 Certified Operator: Certification Number: Back-up Operator: Certification Number: to,, (ef Location of Farm: Z p (,[ J `�G�Gwr m �� Latitude: Longitude: Design Current Design Current Design Current Swine Capacity Pop. Wet Poultry Capacity Pop. Cattle Capacity Pop. Wean to Finish Wean to Feeder Feeder to Finish ?-Otq Farrow to Wean Farrow to Feeder Farrow to Finish Boars Other Layer Non -La er Pullets Poults Design Current Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? b. Did the discharge reach waters of the State? (if yes, notify DWR) c. What is the estimated volume that reached waters of the State (gallons)? Dai Cow Dai Calf Dair y Heifer Dry Cow Non-Dai Beef Stocker Beef Feeder Beef Brood Cow ❑ Yes gloNo ❑ NA ❑ NE ❑ Yes ❑ No ❑ NA ❑ NE ❑ Yes ❑ No ❑ NA ❑ NE d. Does the discharge bypass the waste management system? (If yes, notify DWR) 2. Is there evidence of a past discharge from any part of the operation? 3. Were there any observable adverse impacts or potential adverse impacts to the waters of the State other than from a discharge? ❑ Yes ❑ No ❑ NA ❑ NE ❑ Yes ZNo ❑ NA ❑ NE [:]Yes ONo ❑ NA ❑ NE Page l of 3 511212020 Continued Facili Number: 4 - jDate of Inspection: ♦ • Waste Collection & Treatment 4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? El Yes � o ❑ NA ❑ NE a. If yes, is waste level into the structural freeboard? ❑ Yes ONo ❑ NA ❑ NE Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: Spillway?: p Designed Freeboard (in): 1 Observed Freeboard (in):o _ 5. Are there any immediate threats to the integrity of any of the structures observed? ❑ Yes ZNo ❑ NA ❑ NE (i.e., large trees, severe erosion, seepage, etc.) 6. Arc there structures on -site which are not properly addressed and/or managed through a [:]Yes O No ❑ NA ❑ NE waste management or closure plan? If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR 7. Do any of the structures need maintenance or improvement? ❑ Yes Z�No ❑ NA ❑ NE 8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes [ ❑ NA ❑ NE (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ Yes UJ`No ❑ NA ❑ NE maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ Yes VTNo ❑ NA ❑ NE miaintenance or 'm rovem-0 p 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. [:]Yes ZNo ❑ NA ❑ NE ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate ManureiSludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑Evidence of Wind Drift ❑ Application Outside fof Approved Area 12. Crop Type(s): t SJVK Iyl t.✓ /4y. ✓1 L f —r- 13. Soil Type(s): 14. Do the receiving crops differ from those designated in the CAWMP? ❑ Yes No ❑ NA ❑ NE 15. Does the receiving crop and/or land application site need improvement? ❑ Yes KNo ❑ NA ❑ NE 16. Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ Yes VNo ❑ NA 0 NE acres determination? 17. Does the facility lack adequate acreage for land application? ❑ Yes 0No ❑ NA ❑ NE 18. Is there a lack of properly operating waste application equipment? ❑ Yes P"No D NA ❑ NE Required Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? ❑ Yes Zf�No ❑ NA ❑ NE 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes jrNo ❑ NA ❑ NE the appropriate box. ❑WUP ❑Checklists ❑Design ❑ Maps ❑ Lease Agreements ❑Other: 21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes No ❑ NA ❑ NE ❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code ❑ RainfalI ❑ Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? ❑Yes No NA ❑ NE 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes o ❑ NA ❑ NE Page 2 of 3 fff��� 511212020 Continued Facility Number: - O Date of Inspection: WZA 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes ;?I No 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check ❑ Yes ONO the appropriate box(es) below. ❑ Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ Yes )?I No 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? ❑ Yes 0No Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? 34. Does the facility require a follow-up visit by the same agency? ❑ NA ❑ NE ❑NA ❑NE ❑NA ❑NE ❑NA ❑NE ❑ Yes 7No ❑ NA ❑ NE ❑ Yes [?fNo ❑ NA ❑ NE ❑ Yes e No ❑ NA ❑ NE ❑ Yes Z!fNo ❑ NA ❑ NE ❑ Yes ZNo ❑ NA ❑ NE ❑ Yes [;2�0 ❑ NA ❑ NE ❑ Yes VNo ❑ NA ❑ NE Comments (refer to question #): Explain any YES answers and/or any additional recommendations or any other comments. Use drawings of facility to better explain situations (use additional pages as necessary). 12'y'.z020 p — L4 o a o L4 0 rj 4j CA s s a Zo-t.t *llor S �v Mgt S,�ry l2 cvg" ff :JCE Z°Z° Reviewerl Inspector Name: ReviewerlInspector Signature: Page 3 of 3 TH [ "+ O p N 0 Phone: Date: 511212020