HomeMy WebLinkAboutWQ0005763_CEIARR_20210812 SENT VIA ELECTRONIC MAIL ONLY: NO HARD COPY WILL BE MAILED August 12, 2021 Daniel Manring Email: dmanring@twsanc.us Tuckaseigee Water and Sewer Authority SUBJECT: Compliance Inspection Report: Annual Report Review Tuckaseigee Water and Sewer Authority DCAR Non-discharge Permit No. WQ0005763 Jackson County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Tuckaseigee Water and Sewer Authority DCAR on 8/12/2021. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non-discharge Permit No. WQ0005763. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact me at 828-296-4686 or via email at mikal.willmer@ncdenr.gov. Sincerely, Mikal Willmer, Environmental Specialist II Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS: Inspection Report Ec: LF Stan Bryson, ORC Compliance Inspection Report Permit:WQ0005763 Effective:08/01/19 Expiration:09/30/24 Owner :Tuckaseigee Water and Sewer Authority SOC: Contact Person: Region: County: Directions to Facility: Jackson Asheville Daniel Manring Effective:Expiration:Facility:Tuckaseigee Water and Sewer Authority DCAR 1871 N River Rd Sylva NC 28779 Title:Phone:828-586-5189 Secondary ORC(s): Phone:Certification:Primary ORC: System Classifications: On-Site Representative(s): Related Permits: NC0063321 Tuckaseigee Water and Sewer Authority - TWSA Plant #3 NC0087602 Tuckaseigee Water and Sewer Authority - Whittier WWTP NC0020214 Tuckaseigee Water and Sewer Authority - TWSA WWTP#2 NC0039578 Tuckaseigee Water and Sewer Authority - Jackson County WWTP Secondary Inspector(s): Primary Inspector: Inspection Date:Exit Time:Entry Time: Phone: 08/12/2021 10:00AM 10:55AM Mikal Willmer 828-296-4686 Facility Status: Permit Inspection Type: Reason for Inspection:Inspection Type: Not CompliantCompliant Routine Distribution of Residual Solids (503) Annual Report Review Question Areas: Miscellaneous Questions Record Keeping Treatment Pathogen and Vector Attraction (See attachment summary) Page 1 of 4 Inspection Date: Permit: Inspection Type : Owner - Facility: Reason for Visit: WQ0005763 08/12/2021 Annual Report Review Tuckaseigee Water and Sewer Authority Routine Inspection Summary: Mikal Willmer, with the Asheville Regional Office, conducted a review of TWSA’s 2020 Annual Residuals Report on August 12, 2021. This review was conducted to determine whether all monitoring and residuals handling are in compliance with Permit No. WQ0005763. TWSA is permitted to distribute 659 Dry Tons of residuals annually. 86.3 dry tons were hauled to the R&B Landfill in Homer, GA. 205.9 dry tons of residuals were distributed to the public. Pathogen & Vector Attraction Reduction: All fecal coliform densities reported were below 1,000 MPN/g. Pathogen reduction was met using PFRP Heat Drying, and vector attraction was met through drying of unstabilized residuals. Non-hazardous Waste Characterization: All results appeared to be in compliance with federal and state permit requirements. Nutrients, Metals & Pollutants: All data appeared to reported as required by permit and in compliance with the applicable pollutant monthly and ceiling concentration limits. Page 2 of 4 Inspection Date: Permit: Inspection Type : Owner - Facility: Reason for Visit: WQ0005763 08/12/2021 Annual Report Review Tuckaseigee Water and Sewer Authority Routine Type Yes No NA NE Land Application Distribution and Marketing Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? Are GW samples from all MWs sampled for all required parameters? Are there any GW quality violations? Is GW-59A certification form completed for facility? Is a copy of current permit on-site? Are current metals and nutrient analysis available? Are nutrient and metal loading calculating most limiting parameters? a. TCLP analysis? b. SSFA (Standard Soil Fertility Analysis)? Are PAN balances being maintained? Are PAN balances within permit limits? Has land application equipment been calibrated? Are there pH records for alkaline stabilization? Are there pH records for the land application site? Are nutrient/crop removal practices in place? Do lab sheets support data reported on Residual Analysis Summary? Are hauling records available? Are hauling records maintained and up-to-date? # Has permittee been free of public complaints in last 12 months? Has application occurred during Seasonal Restriction window? Distribution of Class A residuals to private citizens. Used with various crops.Comment: Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D (Class B only) Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) c. pH records for alkaline stabilization (Class B) Temperature corrected d. Salmonella (Class A, all test must be < 3MPN/4 gram day) Page 3 of 4 Inspection Date: Permit: Inspection Type : Owner - Facility: Reason for Visit: WQ0005763 08/12/2021 Annual Report Review Tuckaseigee Water and Sewer Authority Routine e. Time/Temp on: Digester (MCRT) Compost Class A lime stabilization f. Volatile Solids Calculations g. Bench-top Aerobic/Anaerobic digestion results PFRP-Heat Drying.Comment: Treatment Yes No NA NE Check all that apply Aerobic Digestion Anaerobic Digestion Alkaline Pasteurization (Class A) Alkaline Stabilization (Class B) Compost Drying Beds Other Drying of unstabilized residuals.Comment: Page 4 of 4