HomeMy WebLinkAbout770012_Routine Inspection_20210804lc-
Fadllii
1
in of Water Resources::
n of Soil and Water Conservation
cy
Type of Visit: ,C) Compliance Inspection 0 Operation Review 0 Structure Evaluation 0 Technical Assistance
Reason for Visit: Routine 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access
Date of Visit:
Farm Name:
Arrival Time:
0-, Ai)
Owner Name: if) , () , PA,64.4760CUM'
Mailing Address:
Physical Address:
Facility Contact: f , "z1 r�J/,<_
Onsite Representative: //
Departure Time: 1'- `®t // County:
Owner Email:
Phone:
W//Region: ,
Title:
Certified Operator:
Back-up Operator:
Location of Farm:
Latitude:
Design Current
Capacity Pop.
Phone:
Integrator: -1:61.4X
tej
Certification Number: / 7 6
Certification Number:
Design Current
Po'..
Discharges and Stream Impacts
1. Is any discharge observed from any part of the operation?
Discharge originated at: ❑ Structure ❑ Application Field ❑ Other:
a. Was the conveyance man-made?
Longitude:
❑ Yes , No ❑ NA ❑ NE
O Yes ❑ No ❑ NA ❑ NE
b. Did the discharge reach waters of the State? (If yes, notify DWR) ❑ Yes 0 No ❑ NA 0 NE
c. What is the estimated volume that reached waters of the State (gallons)?
d. Does the discharge bypass the waste management system? (If yes, notify DWR) 0 Yes ❑ No 0 NA ❑ NE
2. Is there evidence of a past discharge from any part of the operation? 0 Yes ,.JNo ❑ NA ❑ NE
3. Were there any observable adverse impacts or potential adverse impacts to the waters 0 Yes pl'f\io ❑ NA ❑ NE
of the State other than from a discharge?
Page 1 of 3
2/4/2015 Continued
Facility Number: 7')
Waste Collection & Treatment
Date of Inspection: yiVt`
12. Crop Type(s):
13. Soil Type(s):
4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate?
a. If yes, is waste level into the structural freeboard?
Structure 1 Structure 2 Structure 3
Identifier:
Spillway?:
Designed Freeboard (in):
Observed Freeboard (in):
0/F
❑ Yes
❑ Yes
Structure 4 Structure 5
alCro ❑ NA ❑ NE
I] No ❑NA ❑NE
Structure 6
5. Are there any immediate threats to the integrity of any of the structures observed? ❑ Yes Ea -No ❑ NA ❑ NE
(i.e., large trees, severe erosion, seepage, etc.)
6. Are there structures on -site which are not properly addressed and/or managed through a ❑ YesNo ❑ NA ❑ NE
waste management or closure plan?
If any of questions 4-6 were answered yes, and the situation poses an immediate public
7. Do any of the structures need maintenance or improvement? ,e'S'es ❑ No
8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes )2/No
(not applicable to roofed pits, dry stacks, and/or wet stacks)
9. Does any part of the waste management system other than the waste structures require ❑ Yes .12%1<lo
maintenance or improvement?
Waste Application
10. Are there any required buffers, setbacks, or compliance alternatives that need
maintenance or improvement?
11. Is there evidence of incorrect land application? If yes, check the appropriate box below.
health or environmental threat, notify DWR
❑ NA
❑ NA
❑ NA
❑ NE
❑ NE
❑ NE
❑ Yes _g'No ❑ NA ❑ NE
❑ Yes ,No ❑ NA ❑ NE
❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.)
❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil
❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area
,07,4-rej i3Ze/?-1-4 //,e—e/0•0 (.4,--,dr)661-itd(?
Wi2JL4
14. Do the receiving crops differ from those designated in the CAWMP?
15. Does the receiving crop and/or land application site need improvement?
16. Did the facility fail to secure and/or operate per the irrigation design or wettable
acres determination?
17. Does the facility lack adequate acreage for land application?
18. Is there a lack of properly operating waste application equipment?
Required Records & Documents
19. Did the facility fail to have the Certificate of Coverage & Permit readily available?
20. Does the facility fail to have all components of the CAWMP readily available? If yes, check
the appropriate box.
❑ WUP ❑Checklists ❑ Design ❑ Maps ❑ Lease Agreements ❑Other:
21. Does record keeping need improvement? If yes, check the appropriate box below.
El Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis
❑ Rainfall ❑ Stocking
❑ Yes ErNo ❑ NA ❑ NE
El Yes Ei No ❑ NA ❑ NE
❑ Yes ,LJ No ❑ NA ❑ NE
❑ Yes 12 No ❑ NA ❑ NE
❑ Yes 13,No ❑ NA ❑ NE
❑ Yes al-" o ❑ NA ❑ NE
❑ Yes -No ❑ NA ❑ NE
''Yes ❑ No ❑ NA ❑ NE
❑ Waste Transfers ❑ Weather Code
Crop Yield 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey
22. Did the facility fail to install and maintain a rain gauge?
23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment?
Page 2 of 3
❑ Yes :.'No ❑ NA ❑ NE
❑ Yesio ❑ NA ❑ NE
5/12/2020 Continued
Facility Number: 1') - / I
Date of Inspection: L;
r
24. Did the facility fail to calibrate waste application equipment as required by the permit?
25. Is the facility out of compliance with permit conditions related to sludge? If yes, check
the appropriate box(es) below.
❑ Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels
❑ Non -compliant sludge levels in any lagoon
List structure(s) and date of first survey indicating non-compliance:
❑ Yes 12r No ❑ NA ❑ NE
❑ Yes 2-No ❑ NA ❑ NE
26. Did the facility fail to provide documentation of an actively certified operator in charge?
27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification?
Other Issues
28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document
and report mortality rates that were higher than normal?
29. At the time of the inspection did the facility pose an odor or air quality concern?
If yes, contact a regional Air Quality representative immediately.
30. Did the facility fail to notify the Regional Office of emergency situations as required by the
permit? (i.e., discharge, freeboard problems, over -application)
31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below.
❑ Application Field ❑ Lagoon/Storage Pond ❑ Other:
❑ Yes No ❑ NA ❑ NE
❑ Yes ❑"No ❑ NA ❑ NE
❑ Yes jallo ❑ NA ❑ NE
❑ Yes J No ❑ NA ❑ NE
❑ Yes .' No ❑ NA ❑ NE
❑ Yes No ❑ NA ❑ NE
32. Were any additional problems noted which cause non-compliance of the permit or CAWMP?
33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative?
34. Does the facility require a follow-up visit by the same agency?
❑ Yes 2No ❑ NA ❑ NE
❑ Yes .[]`No ❑ NA ❑ NE
❑ Yes 12eNo ❑ NA ❑ NE
Comments (refer to question #): Explain any YES answers and/or any additional recommendations or any other comments.
Use drawings of facility to better explain situations (use additional pages as necessary).
14 11.12117‘ bc)324-- 4.-a,zz &,,teize,
Zue,,, &ply, ball -A alad /4sr/2-0---
thed, (2t,-,t6et/z,-. /6-y
Reviewer/Inspector Name: L)tq /1-e /Jiqjc 13
Reviewer/Inspector Signature:
Page 3 of 3
Phone:
Date:
/4///A,
5/12/2020
� o
FACILITY #: f ..
:� FARM NAME:
FREEBOARD ACTUAL LAGOON LEVEL
PERMIT (#19)
- DUE EVERY 5 YEARS
- EXPERIATION DATE -%
- OIC CARD''ES cbR NO
NUMBER OF ANIMALS
WASTE UTILIZATION PLAN (WUP) (#20)
SOIL TYPES
CROP TYPES
- THE UTLIZATION PLAN SHOULD,IAVE A (-) NEGATIVE NUMBER
- ODOR CONTROL CHECK LIST SR NO
- Irrigation Plan Maps
WASTE REPORT (#21)
-GOOD FOR 60 DAYS BEFORE OR AFTER
DATE - NITROGEN LEVEL
(,).r' { .
EVERY 3 YEARS:
P-I (NO MORE THEN 400)
Cu/ZN (NO MORE THEN 3000)
(IF PEANUTS NO MORE THEN 300)
MENTAL CHECK OF CROP AND FIELD
SOIL REPORT (#21)
DATE 9/77'/
� 5-
ZONE ACRES PAN
FLOW RATES ,F ,
120 Min inspection initialed
PH (Note if 4 or Tess)
ZN
IRR2 (#21)
CROP TYPE
NITROGEN (N)
Weather Codes
Commercial Fertilizer
° Chicken Litter
CALBRIATION (#24)
- EACH REEL SHOULD BE CALIBRATED l
- DATE DUE EVERY TWO YEARS
- FLOW RATES °
RAIN FALL (#21)
-INITIAL AFTER 1" RAIN EVENT L/
-LOOK FOR ANY LEVEL THAT IS LESS THEN THE DESIGNED FREEBORED
-LOOK FOR BIG NUMBER DIFFERENCES SEE THAT THEY MATCH THE IRR2
FORM
-DUE EVERY YEAR: DATE /
0: P: Lf % RATIO OF SLUDGE
SLUDGE (#21 & 25)
/}
OTHER FORMS (#22 AND #21)
RAIN BREAKER FORM CROP YEILDS
VISUAL CHECK
MORTALITY
FOUNDATION OR PIT LEAKS PIPE LEAKS LAGOON
SEEPAGE LAGOON BARE AREAS TREES OR GRASS NEED TO
BE REMOVED EROSION DITCHES
WINTER CROP(OVERSEEDED) ALIVE CROP HARVESTED
FIELDS GOOD HEALTHY CORPS CORRECT
CROPS NO PONDING REELS FEED
BINS LAGOON GARBAGE