Loading...
HomeMy WebLinkAboutSW4200702_Stormwater Narrative_20210810Lewisville Community Center Stormwater Narrative Summary The proposed Lewisville Community Center project consists of a 11,719 SF community building with associated parking, walkways, and utilities. The site has been laid out in a manor to help preserve several existing trees that will serve as a centerpiece to the parking area and entry drive. A biocell has been utilized to treat the increase of impervious area from the project. While quantity detention is not a requirement, staging has been incorporated into the biocell in order to help limit outflows to the neighboring property. Site Characteristics The existing site consists of dense wooded area to the west and crop land to the east and south. A Town -owned park lies to the north to which pedestrian and automobile connections have been provided. The park and community center parcels have been combined into a single parcel. For stormwater purposes, the limits of construction have been used to examine existing and proposed impervious areas. Some existing impervious exists within the limits and has been grandfathered into the stormwater design. Site soils are generally categorized as sandy loams by the USGS soils map. Site Stormwater Design The 4.76-acre limits area contains 0.23 acres (4.80%). The existing impervious area is made up of an existing dwelling and associated paved driveway access. The proposed build -out includes 1.90 acres (39.92%) of impervious area. A biocell has been utilized to handle the stormwater runoff for the project. The biocell has been designed per the NCDEQ MDC to include internal water storage as required. Per site boring explorations completed by Stewart Engineering, the seasonal high water table was not evident in the biocell area down to a depth of over six feet beneath the biocell bottom. Runoff will be conveyed to the biocell via storm drainage piping from the building and parking areas. Water will enter the biocell through a riprap forebay at the furthest point from the outlet structure as possible to increase retention time. A ponding depth of 12" is proposed in the biocell with an additional 12" of attenuation. Water will drawdown to the underdrain system below and collect in a single pipe to be carried to the outlet. Larger storms will overflow through the provided weirs and grate in the riser structure. Site Stormwater Modification The original, approved plans under permit SW4200702 have been slightly modified in this edition to include a paved fire lane in lieu of grass pavers. This provided an increase in BUA and therefore triggered a permit modification. The biocell geometry did not need to change as a result of this additional BUA. The original biocell was oversized and was able to handle the increase. All applicable calculations and documentation have been provided to support the new numbers.