HomeMy WebLinkAboutSW3210401_Supplement-EZ Form_20210810SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 1 Project Name I Providence Commons - Caliber Collision 3 JCoastal Wetland Area (ac) 0 4 1 Surface Water Area (ac) 0.0527 1 6 1 Does this project use an off -site SCM? I No MPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided feet 50 8 Will the vegetated setback remain vegetated? Yes 9 Is BUA other that as listed in .1003(4)(c-d) out of the setback? Yes 10 Is streambank stabilization proposed on this project? No MBER AND TYPE OF SCM 11 Infiltration System 0 12 Bioretention Cell 0 13 Wet Pond 1 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 ISand Filter 0 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-FS 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Ba filter 0 26 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Marc Momsen, P.E. 28 Organization: LandDesi n 29 Street address: 223 North Graham Street 30 City, State, Zip: Charlotte, NC 28202 31 Phone numbers : 704-333-0325 32 Email: mmomsen@landdesign.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision, that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete, and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. SEAL 033804 �✓q' FNciNEE�.,� C D. Signature .: si ;ner Date 09 Aug 2021 DRAINAGE AREAS 1 Is this a high densityproject? Yes 2 If so, number of drainage areas/SCMs 1 3 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 4 Type of SCM 5 Total BUA in project (sq ft 374984 sf 469403 sf 6 New BUA on subdivided lots (subject to permitting) (sq ft 7 New BUA outside of subdivided lots (subject to permitting) (so 360094 sf 360094 sf 8 Offsite - total area (sq ft N/A 94419 sf 9 Offsite BUA (sq ft N/A 94419 sf 10 Breakdown of new BUA outside subdivided lots: Parking (sq ft 41080 sf 41080 sf Sidewalk (sq ft) 1320 sf 1320 sf Roof (sq ft 20860 sf 20860 sf Roadway s ft 14712 sf 14712 sf Future (sq ft 282122 sf 282122 sf Other, please specify in the comment box below (sq ft 11 New infiltrating permeable pavement on subdivided lots (sq ft N/A 12 New infiltrating permeable pavement outside of isubdivided lots (sq ft N/A 13permitting) Exisitng BUA that will remain (not subject to s ft 14890 sf 14890 sf 14 Existing BUA that is already permitted (sq ft 15 Existing BUA that will be removed (sq ft 323 sf 323 sf 16 Percent BUA 31% 60% 17 Design storm inches 1 in 18 Design volume of SCM cu ft 38465 cf 19 1 Calculation method for design volume Simple Method DITIONAL INFORMATION 20 Please use this space to provide any additional information about the drainage area(s): WET POND 1 Drainage area number 1 2 Design volume of SCM (cu ft) 38465 cf ERAL MDC FROM 02H .1050 31 Is the SCM sized to treat the SW from all surfaces at build -out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM (H:V)? 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No 7 Are the inlets, outlets, and receiving stream protected from erosion (10-year storm)? Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 91 What is the method for dewatering the SCM for maintenance? Pump (preferred) 10 If applicable, will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC (8)? Yes 12 Does the drainage easement comply with General MDC (9)? Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? No 141 Is there an O&M Agreement that complies with General MDC (11)? Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? ET POND MDC FROM 02H .1053 181 Method used Yes SA/DA 19 Has a stage/storage table been provided in the calculations? Yes 20 Elevation of the excavated main pool depth (bottom of sediment removal) (fmsl) 536.00 21 Elevation of the main pool bottom -(top of sediment removal) (fmsl) 537.00 22 Elevation of the bottom of the vegetated shelf (fmsl) 544.00 231 Elevation of the permanent pool (fmsl) 544.50 24 Elevation of the top of the vegetated shelf (fmsl) 545.00 25 Elevation of the temporary pool (fmsl) 546.28 26 Surface area of the main permanent pool (square feet) 13796 sf 27 Volume of the main permanent pool (cubic feet) 72878 cf 28 Average depth of the main pool (feet) 5.28 ft 29 Average depth equation used Equation 2 301 If using equation 3, main pool perimeter (feet) 311 If using equation 3, width of submerged veg. shelf (feet) 32 Volume of the forebay (cubic feet) 12798 cf 33 Is this 15-20% of the volume in the main pool? Yes 34 Clean -out depth for forebay (inches) 90 in 35 Design volume of SCM (cu ft) 38465 cf 36 Is the outlet an orifice or a weir? Orifice 37 If orifice, orifice diameter (inches) 3.50 in 381 If weir, weir height (inches) 39 If weir, weir length (inches) 40 Drawdown time for the temporary pool (days) 2.29 41 Are the inlet(s) and outlet located in a manner that avoids short- circuiting? Yes 42 Are berms or baffles provided to improve the flow path? No 43 Depth of forebay at entrance (inches) 102 in 441 Depth of forebay at exit (inches) 96 in 45 Does water flow out of the forebay in a non -erosive manner? Yes 46 Width of the vegetated shelf (feet) 6 ft 47 Slope of vegetated shelf (H:V) 6:1 48 Does the orifice drawdown from below the top surface of the permanent pool? Yes 49 Does the pond minimize impacts to the receiving channel from the 1- yr, 24-hr storm? Yes 50 Are fountains proposed? (If Y, please provide documentation that MDC(9) is met.) No 51 Is a trash rack or other device provided to protect the outlet system? Yes 52 Are the dam and embankment planted in non -clumping turf grass? Yes 53 Species of turf that will be used on the dam and embankment FACW Meadow Mix 541 Has a planting plan been provided for the vegetated shelf? Yes ADDITIONAL INFORMATION 55 Please use this space to provide any additional information about the wet pond(s): Wet Pond 3 4:46 PM 7/27/2021