Loading...
HomeMy WebLinkAboutWQ0042561_Application (FTSE)_20210802State of North Carolina Department of Environmental Quality DWR Division of Water Resources Division of Water ite-sourcr_s Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Town of Fuquay-Varina Project Name for which flow is being requested: The Preserves at Holland e More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for allpump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: North Harnett Re<aional WWTP b. WWTP Facility Permit #: NC0021636 All flows are in MGD c. WWTP facility's permitted flow 7.5 MGD Fuquay-Varina Allocated Flow 2.60 MGD Lillington Allocated Flow 1.20 MGD Angier Allocated Flow 1.008 MGD d. Estimated obligated flow not yet tributary to the WWTP 1.865 MGD FV Obligated Flow NYT 0.634 MGD Lillington Obligated Flow NYT 0.034 MGD HC Obligated Flow NYT 0.534 MGD Angier Obligated Flow NYT 0.663 MGD e. WWTP facility's actual avg. flow 5.975 MGD FV Actual Flow 1.448 MGD Lillington Actual Flow 0.829 MGD HC Actual Flow 2.987 MGD Angier Actual Flow 0.711 MGD f. Total flow for this specific request 0.015 MGD g. Total actual and obligated flows to the facility 7.855 MGD FV Actual Avg. + Obligated Flow 2.097 MGD Lillington Actual Avg. + Obligated Flow 0.863 MGD HC Actual Avg. + Obligated Flow 3.521 MGD Angier Actual + Obligated Flow 1.374 MGD h. Percent of permitted flow used 104.73% *North Harnett WWTP is being evaluated by HWR for planned future expansion. II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. Page 1 of 4 FTSE 06-13 List pump stations located between the project connection point and the WWTP: (A) Design Pump Average Daily Station Firm Flow** (Name or Capacity, * (Firm / p fl, Number) MGD MGD (B) (C) (D)=(B+C) (E)=(A-D) Obligated, Approx. Not Yet Total Current Current Avg. Tributary Flow Plus Daily Flow, Daily Flow, Obligated Available MGD MGD Flow Capacity*** SLS 120 14.4 5.76 3.558 1.807 5.50 0.260 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): North Harnett Regional WWTP Downstream Permit Number: NCO021636 III. Certification Statement: I Steve Ward certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station in route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assess t addendums for which I am the responsible party. Signature of this form indicates accep anof this wastewater flow. -7 Signing Official Signature Date Page 2 of 4 FTSE 06-13