Loading...
HomeMy WebLinkAboutWQ0042403_Application (FTSE)_20210803 (2)1186 Stonecrest Blvd. Tega Cay, SC 29708 RECENEDINCDMIDWR JUL 21 2021 WQROS MOORESVILLE REGIONAL OFFICE Mooresville Regional Office 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Vermillion Front Subdivision - Private Server Application R. Joe arris & Associates, Inc. 1186 Stonecrest Blvd., Tega Cay, S.C. 29708 (803) 802-1799 July 20, 2021 North Carolina DEQ Mooresville (MRO) Division of Water Quality 610 E. Center Avenue Mooresville, NC 28115 Re: Vermillion Front Subdivision Sewer Plans Sewer Fast Track Application — 2nd Submittal RJH Project No. 3319 To Whom It May Concern, On behalf of Bowman Development Group, we have enclosed the following items for the State's review and approval for the above referenced project: 1. Revised Fast Track Sewer System Extension Application 2. Flow Acceptance Letter and FTSE Form from Cabarrus County 3. Flow Acceptance Letter and FTSE Form from Charlotte Water If you should have any questions or require any additional information, please feel free to contact us at (803) 802-1799 or via email at dgates@rjoeharris.com Sincerely, R. JOE HARRIS & ASSOCIATES, INC. Daniel Gates, P.E. Project Manager Division of Wafter Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Vermillion Front, LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Robert Bowman per I5A NCAC 02T .0106(b) Title: Manager 4. Applicant's mailing address: 13815 Cinnabar Place City: Huntersville State: NC Zip: 28078- 5. Applicant's contact information: Phone number: (704) 875-9704 Email Address: natebowman15@gmail.com II. PROJECT INFORMATION: 1. Project name: Vermillion Front 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.29.55° Longitude: -81.0.31° 5. Parcel ID (if applicable): 91568 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Daniel Gates License Number: 051823 Firm: R. Joe Harris & Associates. Inc. Mailing address: 1186 Stonecrest Blvd City: Tega Cay State: SC Zip: 29708- Phone number: (803) 802-1799 Email Address: dgates(ai,ijoeharris.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Rocky River Permit Number: NC0036269 Owner Name: Charlotte Water V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): Charlotte Water FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? Yes [No ❑N/A 3. If the Applicant is a Home/Property Owners' Association. has an Operational Aereement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Residential Leased ❑ Retail with food preparation/service ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Food and drink facilities ❑ Church ❑ Businesses / offices / factories ❑ Nursing Home 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial % Industrial (See I5A NCAC 02T .0103(20)) ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) >1s there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under I5A NCAC 02T .01 I4(tl? ❑ Yes ® No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f1) Daily Design Flow a,b No. of Units Flow Single -Family Unit (3 bedrooms) 360 gal/day(townhomes) 45 16,200 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 16,200 GPD a See 15A NCAC 02T .0114(b). (d). (e)(l) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .01 I4(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 16,200 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 895 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: . 0Longitude: - ° 3. Design flow of the pump station: 4. Operational point(s) of the pump(s): millions gallons per day (firm capacity) gallons per minute at 5. Summarize the force main to be permitted (for this Pump Station): feet total dynamic head (TDH) Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 1 5A NCAC 02T .0305(f) & (g) ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ I5A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(1) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpaee ➢ If noncompliance with 02T.0305(t) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per I5A NCAC 02B .0200? ® Yes ❑ No ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes ❑ No ➢ Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per I5A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with I5A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version). and the Gravitv Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: I, A .41 e. (Professiona Engineer's name from Application Item 1I1 1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, Roa6RT 1304MA,J , R (Signature Authority's name & title from Application Item 1.3.) `�����pF E S o0`/�9�� o SEAL �rn > - o ) 051823 " ° _ „•, 7/117v attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: 7.13 - Z FORM: FTA 04-16 Page 5 of 5 WATER & SEWER AUTHORITY OF CABARRUS COUNTY 232 Davidson Hwy, Concord, NC 28027 704.786.1783 • 704.795.1564 Fax www,wsacc.org June 21, 2021 Mr. Guillermo Anzola Engineering Assistant Charlotte Water 5100 Brookshire Blvd. Charlotte, NC 28216 Subject: Flow Acceptance Request Vermillion Front Preliminary Plans (revised) Charlotte Water Project Number 20206022 Dear Mr. Anzola: This is a notice of capacity for the flow acceptance request received by the Water and Sewer Authority of Cabarrus County (WSACC) from Charlotte Water on April 15, 2021. WSACC has or will have capacity at the Rocky River Regional Wastewater Treatment Plant and appropriate sewer interceptors to transport and treat the domestic wastewater from the proposed project entitled Vermillion Front Preliminary Plans (revised). The referenced project will serve a residential development with 97 three -bedroom lots, with a projected wastewater flow of34,920 gallons per day (gpd). WSACC understands that this flow acceptance request is a replacement of the flow acceptance request for the same project received in 2020, and that 34,920 gpd is the total flow allocation requested for the project. The wastewater generated by this project will be conveyed through a proposed gravity system, through an existing gravity system, and then enter WSACC's system at the existing 36-inch Clarke Creek Interceptor. If construction of this project does not commence within two (2) years of the date of this notice. the notice is rescinded and a second request and notice will be required before flow capacity is accepted. Please notify WSACC, in writing. when construction of this project is initiated. This sewer capacity allocation may also be cancelled pursuant to the conditions set forth in the WSACC Sewer Allocation and Commitment Policy. If you have any questions, please call meat (704) 786-1783, extension 224. Chad VonCannon, PE Engineering Director cc: Keri Cantrell, PE/Charlotte Wate Michael Wilson/WSACC Thomas Hahn, PE/WSACC. Mark Lomax/WSACC Trent Gobble/WSACC Div 0 W ter Resources State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE —10/18) (WSACC USE ONLY) Vermillion Front Prelim Water Project No. 20206022) a y Plans evised) (Charlotte Section I. Name of wastewater treatment facility (WWTF) receiving wastewater: Rocky River Wastewater Treatment Facility — Permit rINC0036269 ❑ Muddy Creek Wastewater Treatment Facility -- Permit #NC0081621 WWTP tacility'spermitted flow, MGD Estimated obligated flow not yet tributary to the WWTP, MGD WWTP facility's actual avg. daily flow, MGD Total flow for this specific request, MGD Total actual and obligated flows to the facility, MGD Percent of permitted flow used 26,500 3.125 21.947 (82,82% o 0,035 25.107 94.74% permit) Section II. Pump stations along the route from the Jurisdiction's connection point to the WW'FP, Pump Station (Name or Number) , untp StationTotal Permit No. Finn(I Capacity * NIGI) (A) Design Avenge Doily Flow ** (Firm'pli \ICI) (B) Awe\ Current Menage Daily Flow \IGD (C) Obligated, Not Yet Tributary Daily Flow \)GD (U) 1 ('1 Correia Flow I IusQbligated Ploy. \I(D )—tn'I)) Available Capacity*** \IGD Lower Rocky NC0036269 37.000 14.80( 11.259 2,464 13.723 1.077 River PS * 'rhe Firm C'upncit) (design flow) of any pump station is defined us the maximum pumped flaw that can he achieved with he largest pump taken u it of service. "*Design Average I) 'I tlow is the rrrur capacity of II a pump station divided by a peaking factor (pf) not less than 2.5, per section 2,020)(0)(c) of the Minimum Design Criteria. ***A flaming Assessment Addendum shall he attached for each pump station Iaclit ed helween the frrbjell conuecllurl taint and I le 11'w D'D' where available Capacity is < 0. Section III. WSACC Certification Statement: I, Chad VonCannon. t't. cr:rtit} to the best or my knowledge that the addition attic volume or wastewater to be permitted in this project has been evaluated along the route from the connection to the WSACC interceptor to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream ptunp station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the hest available data. This certification applies to those items listed above in Section I and Section II plats all attached planting assessment addcnclums for which I am the responsible party, Signature (Willis form indicates WSAC'C's guarantee of caps 4t tyr this wastewater flow. a / ['VSAC'C"s SigningSignciiu •e Dale WASTEWATER FLOW ACCEPTANCE FORM FOR THE WATER AND SEWER AUTHORITY OF CABARRUS COUNTY Jurisdiction Requesting Flow Acceptance: Date: 4-6-2021 City of Concord ['City of Kannapolis ❑Town of Harrisburg OTown of Mt. Pleasant ®Charlotte Water Project Title, Description, and Number of Lots/Unit: Project Title: Vermillion Front Preliminary Plans — Project # 20206022 Description: The Vermillion Front engineering plans and specifications, as prepared and sealed by Jonathan R. Murdock, NCPE, with R. Joe Harris & Associates, Inc, for wastewater sewer laterals to serve Vermillion Front located on 483 Huntersville-Concord Road, with a wastewater discharge of 34,920 GPD. *Number of Lots: 97 Units OR *Number of Units: 97 units x 360 gpd/unit *Must be included in request. Where will the new line be connected: ❑ Directly into a WSACC Interceptor • Into the Jurisdiction's existing collection system ❑ Into a private line Describe the location of the tie-in line to which the new sewer line will connect: The proposed sewer laterals will tie- in to the existing 8-inch sanitary sewer system, which extends to the 36-inch RCP material WSACC Clarke Creek — Phase 2 Interceptor Which WSACC Interceptor will the flow ultimately be discharged into: 36-inch RCP WSACC Clarke Creek- Phase 2 Interceptor What is the WSACC manhole number that the flow will be discharged into? +/- Node 011719 What is the quantity of flow that will be discharged? 34,920 GPD Flow type: ® Domestic 100 % ❑ Commercial % ❑ Industrial Name of wastewater treatment facility (WWTF) receiving wastewater: ® Rocky River Wastewater Treatment Facility — Permit #NC0036269 ❑ Muddy Creek Wastewater Treatment Facility — Permit #NC0081621 Design drawings of new lines will be submitted to WSACC with the request for acceptance. Drawings can be submitted as a digital file (DWG) or distance and bearing starting with the tap on existing infrastructure. If the new line is to connect directly into a WSACC interceptor, detailed drawings including specification of the tap, will be required before flow acceptance will be provided. Mark Lomax at 704-786-1783, ext. 231, must be notified 48 hours in advance of a connection into a WSACC interceptor. WSACC will inspect connection before, during, and after completion. If construction is not started within two (2) year from the date of approval of the flow acceptance for this project, the approval is rescinded and a second request and approval will be required for the project. WSACC USE ONLY: DATE: ❑ Current sewer model shows an Interceptor as being surcharged south of the manhole in question. ❑ Approved ❑ Not Approved ❑ Current Sewer Model shows: ()F W A 7,4 State of North Carolina QG Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE—10/07) (JURISDICTION USE ONLY) Jurisdiction Requesting Flow Acceptance for Collection System: ❑City of Concord DCity of Kannapolis ❑Town of Harrisburg ❑Town of Mt. Pleasant Charlotte Water Project Title, Description, and Number of Lots/Unit: Project Title: Vermillion Front Preliminary Plans - Project # 20206022 Description: The Vermillion Front Preliminary Plans engineering plans and specifications, as prepared and sealed by Jonathan R. Murdock, NCPE, with R. Joe Harris & Associates, Inc, for wastewater sewer laterals to serve Vermillion Front Preliminary Plans located on 483 Huntersville-Concord Road, with a wastewater discharge of 34,920 GPD. What is the quantity of flow that will be discharged? 34,920 GPD Flow type: ® Domestic 100 % ❑ Commercial % ❑ Industrial % Section I - List the Jurisdiction's pump stations located between the project connection point and the WSACC Interceptor connection point. Pump Station (Name or Number) Firm Capacity * MGD (A) Design Average Daily Flow ** (Firm/pf) MGD (B) Approx. Current Average Daily Flow MGD (C) Obligated, Not Yet Tributary Daily Flow MGD (D) = (B+C) Total Current Flow Plus Obligated Flow MGD (E)=(A-D) Available Capacity*** MGD * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. **Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor not less than 2.5. ***A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where Available Capacity is < 0. Section II. Jurisdiction's Certification Statement: I, Keri Cantrell , certify that, to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving WSACC interceptor; and the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden on any downstream pump station in route to the receiving WSACC interceptor normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Section I plus all attached planning assessment addendums for which, to the best of my knowledge, will not adversely affect the downstream sewer capacity. Signature of this form indicates acceptance of this wastewater flow. KC,; . t 4/9/2021 Jurisdiction's Signing Official Signature Date Revision Date: 08/09/13