HomeMy WebLinkAboutWQ0042711_Application (FTSE)_20210720 (2)WGLA Engineering WGLA Engineering, PLLC 724 5th Avenue West Hendersonville, NC 28739 (828) 687-7177 wgla.com JUL 2 0 2021 July 19, 2021 Tim Heim, PE NC DWR Water Quality Regional Operations Section Asheville Regional Office 2090 US 70 Highway Swannanoa, NC 28778 828-296-4500 Water Quality Regional Operations Asheville Regional Office Re: FY2021-090 / Garrison Lane Site Improvements: Project Wheel (R6) City of Hendersonville Water & Sewer Henderson County, NC Dear Mr. Heim: Enclosed please find one original and one copy of the following for the above referenced project: • Application Fee ($480) • Fast Track Application • Flow Tracking/Acceptance Letter • Site Map • Street Level Map / Master Plan Map The project involves construction of approximately 884 If of 8" gravity sewer, and 4 precast concrete manholes to serve proposed commercial development. The project will be constructed in one phase, and there are no future phases planned at this time. Please let me know if you have any questions or need any additional information for this project. Sincerely, are. . raeri CIVIL ENGINEERS & LAND PLANNERS WGLA Engineering WGLA Engineering, PLLC 724 5th Avenue West Hendersonville, NC 28739 (828) 687-7177 wgla.com - JUL 2 0 2021 -21 PROJECT NARRATIVE TO: Tim Heim, PE NC DWR Water Quality Regional Operations Section Asheville Regional Office FROM: Jared L. DeRidder, P.E. WGLA Engineering, PLLC jderidder@wgla.com DATE: July 15, 2021 Water Quality Regional Operations Asheville Regional Office SUBJECT: FY2021-090 / Garrison Lane Site Improvements: Project Wheel (R6) Henderson County, NC This public project consists of a sewer line extension to serve commercial development. The sewer line extension is being constructed by: City of Hendersonville Water and Sewer Department 305 Williams Street Hendersonville, NC 28792 (828) 697-3073 The proposed sewer extension will be an 8" PVC Gravity Sewer Main that runs across the Garrison property and along Commercial Blvd. The proposed sewer extension will tie to a proposed manhole that serves a City of Hendersonville 12" PVC sewer main. The Garrison Lane extension will have a total of four manholes and approximately 884LF+/- of 8" PVC sewer. This project is estimated to be completed by December 2021. I, or an authorized representative of WGLA Engineering, will be observing and monitoring the progress of construction for this project. Should you have any questions, concerns or comments regarding this project, please feel free to contact me. Sincerely, WGLA Eytgineering, PLLC J4fed L. DeRidder, P.E. CIVIL ENGINEERS & LAND PLANNERS D Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources t5A NCAC 02'1.03U0 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION INSTRUCTIONS FOR FORM: rrA 04-Ir5 & SUPPORTING DOCUMENTATION This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination thot has been certified by a professional engineer and the applicant that the project meets the requirements of I5A NCAC 021'' and rho Division's Minimum Design Criteria and that plans, specificntions and supporting documents have been prepared in uecurdauce with, 15A NCAC 02T 15A NCAC 02T .0300 Division policies and goad cnoineerbtm practices. While no upfront engineering design documents are required for submittal, in accordance with ISA NCAC 02T .0305(h), design documents must be prepared prior to submittal of It fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in I5A NCAC U2'1_ 0305 ;rod the applicoble minimum design criteria. These documents shall be available upon request by the Division. Projects that arc deemed permitted (do not require a permit from the Division) are explained in 15A NCAC 02'1' 0303. • Ltmac— "d T'%-s----- Projects not eligible for review via the last track process (must be submitted for full technical review): m 0} rilj ) Projects that require on environmental assessment in accordance with ISA NCAC IC .0100; co = s_ ) > Projects that do not meet any part of the minimum design criteria (MDC) document; m r • Projects that involve a variance from the requirements of ISA NCAC 2T; A • Pressure sewer systems utilizing septic tank -effluent pumps (STEPS) or simplex grinder pumps; ro 0 ) STEP or simplex grinder pumps connecting to pressurized systems (e.g. force miss); o o • Vacuum sewer systems. = m. o o& f- o c, d�Jr General— When submitting an application, please use the following instructions as a checklist in order to ensure all f@gt2ired stet ^ --_I are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker revie €time an reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result In return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy of Application and Supporting Documents Ei Required unless otherwise noted D. Cover Letter (Required for Ali Application Packages): MI List all items Included in the application package, as well as a brief description of the requested permitting action, • Be specific as to the system type, number of homes served, flow allocation required, etc. ) If necessary for clarity, include attachments to the application form. C. Application Fee (All New and Major Modification Application Packages): ® Submit a check or money order in the amount of $480.00 dated within 90 days of application submittal. • Payable to North Carolina Departinenl of Environmental Quality (NCDEQ) D. Fast Track (Form: FTA 04-16) Application (Required for All Application Packages): ® Submit the completed and appropriately executed application. ) If necessary for clarity or due to space restrictions, attachments to the application may be made. ❑ If the Applicant Type in Item 1.2 is a cotparation or company, provide documentation it is registered for business with the North Carolina Secrerm'yp f State. ❑ If the Applicant Type in Item 1.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ❑ The Pro ect Name in Item II, I shall be consistent with the mu' c name on the ® The Profession& Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer, tEl The Applicant's Certification on Page 5 of the application shall be signed in accordance with ISA NCAC 02T .0 106(h). Per ISA NCAC 02T .0106(e), an alternate peson may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in I5A NCAC 02T .0106(b). INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMBNTATION Page I of 3 E. Flow Tracking/Acceptance Form (Form: VISE 04-16) (If Applicable): ❑ Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. A Multiple forms maybe required where the downstream sewer owner and wastewater treattnent facility are different. Y The flow acceptance indicated in form FTSE muss tint expire prior to permit issuance and must be dated less than one year prior to the application date. Y Submittal of this application and form F I'SG indicates that owner has adequate capacity and will not violate G.S. 143- 215.67(a). A Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific VISE. F. Site Mops (All Application Packages): 121 Submit an 8.5-inch x I I -inch color copy of u USGS Topographic Map of sufficient scale to identify the entire project area and closest surface waters, A Location of the project (gravity sewer, pump stations & force main) A Downstream connection points and permit number (if known) for the receiving sewer ❑ Include a street level map (aerial) showing general project arca so that Division staff can easily locate it in the field, G. Existing Permit (All Modification Packages): ❑ Submit the most recently issued existing permit. ❑ Provide a list of any items within the permit the Applicant would like the Division to address during the permit modification (Le., permit description, flow allocation, trcaunent facility, etc.). H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): ❑ Per ISA NCAC 02T.0305(h)(11, submit documentation of power reliability for pumping stations. A This alternative is only available for average daily flows less than 15,000 gallons per day A It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and Is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(h)) or proposed contractor, stating that"the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." ❑ If the portable power source or pnrnp is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel thneframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) 1. Certificate of Public Convenience and Necessity (A11 Application Packages for Privately -Owned Public Utilities): ❑ Per 15A NCAC 02'1' .0115(a)(I) provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): ❑ Home/Property Owners' Associations ❑ Pet 1?.A,..,C:SC-Q21'.Q11Lc), submit the properly executed Operational A"reement. (FORM: NOA). ❑ Per I5A NCAC 02T .0115(c), submit a copy of the Articles of incorporation, Declarations and By-laws. ❑ Developers of lots to be sold ❑ Per 15A NCAC 02T.0115(b), submit the properly executed Operational Agreement FORM: DLV). For more information, visit the Division's collection systems website INSTRUCTIONS FOR FORM; F1'A 04-16 & SUPPORTING DOCUMENTATION Page 2 of 3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Swannanoe, North Carolina 28778 (828) 296-4500 (828) 299-7043 Fax Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey Water Quality Section Fayetteville Regional Office 225 Green Street Suite 714 Fayetteville, North Carolina 28301.5094 (910) 433-3300 (910) 486-0707 Fax Anson, Bladen, Cumberland, Harnett, Hoke, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland Water Quality Section Mooresville Regional Office 810 E. Center Avenue Mooresville, North Carolina 28115 (704) 663-1699 (704) 663-6040 Fax Alexander, Cabanas, Catawba, Cleveland, Gaston, Iredell, Lincoln, Mecklenburg, Rowan. Stanly, Union Water Quality Section Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 (919) 791-4200 (919) 788.7159 Fax Chatham, Durham, Edgecombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson Water Quality Section Washington Regional Office 943 Washington Square Mall Washington, North Carolina 27809 (252) 946-6481 (262) 976-3716 Fax Beaufort, Belie, Camden, Chowan, Craven, Cunituck, Dare, Gates, Greene, Redford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Water quality Section Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 360.2004 Fax Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pander Water quality Section Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, North Carolina 27105 (336) 776-9800 Alamance, Allegheny, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin Water Quality Section INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 3 of 3 DWI?. Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources ISA NCAC 021' .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION PTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (re be completed by I)Wk) All Items most be completed or the application will be returned 1. APPLICANT INFORMATION: 1. Applicant's name: City ofllendersonville Water and Sewer Department (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual 0 Corporation ❑ General Partnership ❑ Privately -Owned Public Utility El Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's nano: Lee Smith per I5A NCAC 02T 0106(10 Title: Utilities Director 4. Applicant's mailing address: 305 Williams Street City: Hendersonville State: NC Zip: 2R792- 5. Applicant's contact Information: Phone number: (828) 697-3073 Email Address: Ismith n hvinc.com 11. PROJECT INFORMATION: I. Project name: FY2021-090/Garrison Lane Site lmmovements: Project Wheel (R6) 2. Application/Project status: /. Proposed (New Permit) ❑ Existing Permit/Project Ifa modification, provide the existing permit number: W000 and Issued date: Ifnew construction but part of a master plan, provide the existing permit number: W000` 3. County where project is located: Henderson 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.290469` Longitude: -82.409161° 5. Parcel ID (if applicable): 9587-3R-0701 9587-27-9898 ,9587-3R-7266 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I. Professional Engineer: Jared L. DeRidder License Number: 041349 Firm: WOLA Ennineering, PLI..0 Mailing address: 724 5'h Avenue West City: Hendersonville Slate: NC Zip: 28739- Phonc lumber: (8281687-7177 Email Address: jdirjdder@wgla.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: HeneiiQnville WWTP Permit Number: 1JC0025534 Owner Name: City of Hendersonville V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): ?3O.}I.1LVr JUL 2 0 2021 Water Quality Regional Upera Asheville Regional OGii I. PermitNmnber(s): WQ System Wide Collection System Penn' Owner Name(s): Downstream (Receiving) Sewer Size: _ inch umber(s) (if applicable): WQCS FORM: F'IA 04-16 Page I of 5 VI, GENERAL REQUIREMENTS 1. Mlle Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes DNo ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Opgmaional Amroment JFORM: DIN) been attached? ❑ Yes ❑No EN/A 3. lithe Applicant is a J lome/Prooerly Owners' Association has an Oneralional Agreement (FORM:110A) been attached? ❑Yes DNo EN/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Residential Lensed El School / preschool / day care ❑ Food and drink facilities - - E Businesses / offices / factories ❑ Retail (stores, centers, malls) ❑ Retail with food preparation/service ❑ Medical / dental / veterinary facilities ❑ Church ❑ Nursing Hume 5. Nature of wastewater: %Domestic/Commercial 6. 7. ❑ Car Wash ❑ lintel and/or Motels ❑ Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) % Commercial % Industrial (See 15A NCAC 02'f .0103(20D 1----->is there a Pretreatment Program in effect? ❑ Yes E No ',etion boon approved under I SA NCAC 021' 0114(fl? 0 Yes Ide a cony of flow reduction annroval letter ewater generated by project No , Pype (see 02T'.0114()) Daily Design Flow ":1' No. of Units Flow i °/ ps and factories 25 gal/employee 150 3750 GPD ln� ,. gal/ GPD gal/ GPD gal/ GPD gal/ GPD gad/ GPD Total 3750 GPD a See I5A NCAC 02T .0114(h) (d), (e)(1) and (e)(2.) for caveats to wastewater design flow rates (f,e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02'1',0114(c), design flow rates for establishments not identified [in table l iA NCAC 021'.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 3750 GPD (per j5A NCAC 02T .01 I4) A Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: 0 Pump Station or Gravity Sewer where flow will be permitted in subsequent permits Ihitt connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Other (Explain): eaten xis mg sewer Wr 1 no new expec FORM: F'TA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.9305 & MDC (Gravity Savers): I. Summarize gravity sewer to be permitted: > Section 11 @.Ill of [he MDC for Permitting of Gravity Sewers contains information rola cd to design criteria > Section 111 contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirement is not allowed mall n violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — (12T .0305 & M DC (Pump Stations/rem Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute nt feet total dynamic head (TDII) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability In accordance with 156 Kg' 02T, 70 05(())t_Ij: ❑ Standby power source or pump with automatic activation and telemetry - I5A NCAC 02T .0305(h)(1)(3) > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has nn average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and Iclemetry - I5A NCAC 02T .0305(h)(1)(C) or ❑ Portable pmnping unit with plugged etnergcncy pump connection and telemetry- I5A NCAC 02T .0305(h)(1)(C): > It shall be demonstrated to the Division that the mailable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation Mali the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in Iho case of a multiple station power outage. FORM: PTA 04-16 Page 3 of5 IX. SETBACICS&SEPARATIONS — (0213.0200 & ISA NCAC 02T .0305(Q): 1. Does the project comply with all separations found in I5A NCAC 02T .0305(1) & (a) D I5A NCAC 02110305(Q contains minimum separations that shall be provided for sewer vstems. ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimod over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class 1 or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), H, SA, ORW, I IQW, or SD from normal high water or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, Impoundment, or ground water lowering and surface drainage ditches 10 feet. Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts oft feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches D 15A NCAC 02T.032Q5(g) contains alternatives where separations in 02T.030501 cannot be achieved. D **Stream classifications can be identified using the Division's NC Surface Water Classifications wgbpagf D If noncompliance with 02T.0305(QorPO, see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) 14 Yes ❑ No 0 N/A > Sec the Division's draft separation requirements for situations where separation cannot be meet D No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per.15A NCAC g?R_:02()0? ❑ Yes ❑ No ® N/A > This would include Trout Fluttered Streams per ISA NCAC 213.0202 4. Does the protect require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? D Information can be obtained from the 401 & Buffer Permiitinn Branch 5. Does project comply with I5A NCAC 02'f.0105(c)(6) (additional penults/certifications)? 0 Yes El No Per 15A NCAC 02T.0105(c)(6) directly related environmental permits or certification applications am being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent or issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project Include any sewer collection lines that are deemed "high -priority?' Per 1 SA NCAC 9,7,.l'.p102, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to snowbanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes No ❑ N/A D If yes, include an attachment with details for each line, including type (aerial line, size, material, and locution). High priority lines shall be Inspected by the permittee or Its representative at least once every slx-months and Inspections documented per ISA NCAC 02T.0403(a)(S) or the pe•mitee's individual System -Wide Collection permit. PORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: I. Does the submitted system comply with I_5A (CAC 02T, the Minimum Design Criteria for the Permitting, of puma Stations and Force onsSlatest versionl and the C„/^'(rvilky S t_er Mimmunt-Desien Cru ria (liges,t, version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents ler review, Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: --at oft, I„,_ DEftv03 attest thal this application for (Professional Engineer's name from Application Item 111.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 funlicr attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Putnp Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies That I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: .'q$.. GAis Os jZ . 4• 0y', T .. 041340 : c 71y21 9f•P110st:e�.••r�:' • 3. Applicant's Certification per I5A NCAC 02T .0106(b): I, let _ ,SM:4L O4: 1 «es D:aecvit- attest that this application for (Signature Authority's name& title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an Iuunedhae enforcement action that may include civil penalties, injunctive relief, andlorcriminal prosecution. I will make no claim against the Division of WaterResources should a condition of this permit be violated. 1 also understand that Hall required parts of this application package are not completed and that if all requited supporting information and attachments are not included, this applicationpackage will be returned to me as incomplete. NOTE - In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any Fake statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Lee FORM: FTA 04-16 Page 5 of 5 ;..1'(.T\i1In ,)) 1�so J JUL 2 0 2021 , State of North Carolina Department of Environmental Quality Division of Water Resources Division of Water acsoorces Flow Tracking for Sewer Extension Applications Amer Quality Regional Operations (FTSE 1 0-18) ft; gional Office Entity Requesting Allocation: City of Hendersonville Project Name for which flow is being requested: FY202I-090/Garison Lane Site Improv. More than one FTSE may be required fora single project hetheowner of the WWTP Is not responsible for all pump stations along the route of the proposed ivastewnler flow. C Complete this section only if you are the owner of the wastewater treatment plait. a. WWTP Facility Name: Hendersonville WWTF b. WWTP Facility Permit /I: NC0025534 All flows are hi MGD c. WWTP facility's permitted flow 4.800 d. Estimated obligated flow not yet tributary to the WWTP 0.311 e. WWTP facility's actual avg. flow 2.850 f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 0.00375 3.165 65.9% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm /pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. **Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is a 0. Downstream Permit Number: Page 1 of 6 FTSE 10-18 III. Certification Statement: I Lee Smith certify to the best of my knowledge That the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which 1 am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. 7£m'e / s2/ Signing Offrci Sy, m itre ate ll( roc Title of Signing Offrrial r Page 2 of 6 FTSE 10-18 Cipcs ..,.eEO,aa.,,,U..n iiUSTapo PROPERTY BOUNDARY PROPOSED SEWER EXTENSION EXISTING COH SEWER MAIN WGLA Engineering INTERSTATE 26 iMm COMMERCIAL BLVD CREST ROAD `;\N CARp7%% N.otrot Ca oER on WGLA ENGINEERING, PLLC 724 o1L AVENUE HENDERSONVILLE, NC 28739 (828)687-7177 WGLA.COM NC LICENSE P-1342 Fv2n21-o90 / GARRIcON LANE SITE IMPROVEMENTS: PROJECT WHEEL (R6) NORTH CAROLINA SEWER CONNED ION EXHIBIT Job #: 20172 Date: 7/15/21 Scale: 1"=400'