Loading...
HomeMy WebLinkAboutWQ0042716_Application (FTSE)_20210729DEVELOPMENT DATA OWNER/DEVELOPER: CONTACT: CIVIL ENGINEER: CONTACT: ARCHITECT: CONTACT: KITUWAH LLC PO BOX 366 CHEROKEE, NC 28719 TRAVIS SMITH (828) 477-4145 CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NC 28801 ROSS WALL, P.E. (828) 252-5388 KITUWAH MANUFACTURING, LLC 525 BARNESVILLE HWY WYLLIESBURG, VA 23976 JON HUGHES (434) 735-8111 WHITTIER SUBDIVISION PHASE I SWAIN COUNTY, NORTH CAROLINA PREPARED FOR: KITUWAH LLC PO BOX 366 CHEROKEE, NC 28719 TRAVIS SMITH (828) 477-4145 INDEX OF SHEETS Sheet Number Sheet Title C000 COVER C101 EXISTING CONDITIONS AND DEMO PLANS C201 SITE PLAN C301 ROUGH GRADING & EROSION CONTROL C501 STORM PLAN C502 ROADWAY & STORM PROFILE C601 WATER PLAN C701 SEWER PLAN C702 SEWER PROFILE C921 SITE DETAILS C931 ROUGH GRADING & EROSION CONTROL DETAILS C932 ROUGH GRADING & EROSION CONTROL DETAILS C951 STORM DETAILS C952 STORM BMP DETAILS C961 WATER DETALS C971 SEWER DETAILS C998 NCGO1 g YR SON OM HWY 74 as z4,ct 9'�0 0 (t. 95 SUBJECT PROPERTY VICINITY MAP (NOT TO SCALE) Know what's below. CaII before you dig. 168 PATTON AVENUE coin mmom O ro 0 W aD N N N 0 1— W 0 N ch O )iL NQu)it, Z N N , Z Tr J N N W W N N J CO CO W J CO CO W Z H> W X 10LL fnH WOLL as ZQa a3 3 N in www.civildesignconcepts.com NCBELS LICENSE #: C-2184 W U) SUBMITTAL PLAN SET W W EROSION CONTROL RESUBMITTAL SANITARY SEWER SUBMITTAL TWSA COMMENTS & FAST TRACK SUBMITTAL DESCRIPTION N O 0 O O N 0 N O O O O N O N N O W 0 N V) ci Z W Ii Z 0 co W V cc W COVER FOR: DRAWN BY: RWW CDC PROJECT NO.: 22109 SHEET C000 NOTES 1. ALL PUBLIC SANITARY SEWER WORK ASSOCIATED WITH THIS PROJECT TO BE PERFORMED BY A NC LICENSED UTILITY CONTRACTOR. 2. SEE SEWER DETAIL SHEETS FOR ALL GENERAL SEWER NOTES. CONTRACTOR RESPONSIBLE FOR INCLUSION OF DETAILS SHEETS 3. CROSSINGS TO MAINTAIN TWSA REQUIRED VERTICAL SEPARATION. CONTRACTOR TO CONTACT ENGINEER ON ANY CROSSING THAT DOES NOT MEET THIS SEPARATION, OR SEPARATION IS CLOSER THAN 1'. REFER TO GENERAL NOTES ON SEWER DETAIL SHEET FOR SEPARATION REQUIREMENTS BETWEEN UTILITIES. 4. TO SCHEDULE THE REQUIRED INSPECTIONS ON ALL WORK, CALL THE CIVIL DESIGN CONCEPTS INSPECTIONS HOTLINE AT 828-771-4755, OR EMAIL AT INSPECTIONS@CDCGO.COM. FAILURE TO SCHEDULE INSPECTIONS MAY RESULT IN UNCOVERING OR REDOING WORK 5. TYPICAL EASEMENTS FOR SEWER LINES LOCATED OUTSIDE ESTABLISHED UTILITY EASEMENTS OR ROAD RIGHT—OF—WAYS SHALL BE AS SHOWN. THE ENTIRE SEWER EASEMENT MUST BE CLEAR AND REMAINED CLEARED OF TREE PLANTINGS, EXISTING TREES, AND ANY PERMANENT STRUCTURES. 6. NO PORTION OF THIS PROJECT LIES WITHIN THE 100—YR FEMA FLOODPLAIN. PROPOSED MANHOLE TO CUT INTO EXISTING PVC SEWER PIPE APPROXIMATE EXISTING INVERT = 1921.3 NOTE: CONTRACTOR TO VERIFY LOCATION/INVERTS PRIOR TO ORDERING MATERIALS. USE FLEXIBLE PIPE COUPLING AS NEEDED (SEE DETAIL D7.09). \ \ \ \ \ \\ M Fi1 970 \ \ \ \ \ RIM ELEV. 1,937.8\5' DEPTH\ 7.E' \ \ \ 15" CMO N \ \ \ E\\\ \ \ \\ \ \ \, n E1920 u4013005\� \ \ MH#5 \ E RIMEEV.1909E8' \ DEPTH: 7`48'v� 07 \ \ \ 1 \ \ \C#3 J IM \ELEV 1 ,\91 4.08' DEPTH: 7\5M --\MH#2 � \\ RIM ELEV. 1,921\00' \ �o DEPTL\ --� -114''' '....;;91.ftritr,tri. \EC. itita. 10:47,0... .. .44.7.4V.-.,. _.. 4. _ses . s_: Stek. v tii -- \ \__\ \\ \\\\\ \GIs\ \ RS M- ODY R, EEE S e0y D 12 0579 00079 of Acres E\ \ \ L 75 \ \ BE\ vv v �o \ vv \ ,E \ \ \ \ \ 12 1 L71 000v i V Acres �oE\= \ \ E\ \AJAVIVIA 1 \ \:i: ;sae. 44,44, -a;I \\o PROPOSED SEWER CLEANOUT ON INDIVIDUAL SERVICE LINE (TYP) (SEE DETAIL D7.05 & D7.06) ♦ \n/ \ \ \ °s \ \ \ \ \ \ \ \ \ MHO, Il \ \ M E�EV. 1909.85' V\C P TH :\\ 7.0 6' \ \ \(-RiR \ \ Cr \ \ \ \ \ \ E _ -- v vE\ 1II III1ON11 \ \\ N. \vi vEI� II1�(v1I1Ii1II1\Nv N\/Ev \ v vv \ \ -z9A�HIEv)111111\ \\V57y�E\EI-I AV \\ I '�11 a vvv � E/vW4Av0\vVvvAvI\71\)1AIIII1\vvvEI I11 1�1//1 1\\I\ / I CaoL PROPERTY LINE (TYP) ‘ \\N \E \\ I Ho )/' -'\---\ 7 \---: /-- -:11),/\// /1'1/ /1/,\j :1/0))/;//1/: //'' //////:///(///:///://t \\-- —:---- /---- ('' (/11/1/r ///////////'////'/4/1111111/1//////1///////1///////' \ \ / \,/, ////////////////////////////77/ / /0/7 /8/ °Hu \l-to -: ji ?//,!////i//////////17i//////////////////////7///;//////////////////////1/1/////////,/z////zzli/i////////1////////////////////1//,///////////////t7717:7:7: z/ iiiIiilyiri(0//////////://///:///////////7/////////// 7//////////////,/,-,= :10:////, /// /. ;',//,/,/"Iiiii/(8///////%/,%////////////////7//"(///1////1/ l//////////////////////////:////ifil//,;=--, // „/„,//////////////// // -/ ,,I„Azo„,„ • 7,7, SEWER LEGEND EXISTING SEWER LINE EXISTING SEWER MANHOLE PROPOSED SEWER LINE PROPOSED SEWER SERVICE PROPOSED FLOW ARROW PROPOSED SEWER MANHOLE PROPOSED SEWER CLEANOUT SS SS SS STRUCTURE TABLE (INVERTS BASED ON 2D LENGTH TO INSIDE EDGES) STRUCTURE STATION STRUCTURE DETAILS DEPTH DESCRIPTION MH1 10+14 RIM 1937.9 RIM 1921.0 MH6 0+08 RIM 1927.5 INV. IN 1921.5 (MH7— MH6) INV. OUT 1921.3 (MH6 — MH2) MH7 0+41 RIM 1927.9 INV. IN 1922.0 (MH7 — MH8) INV. OUT 1921.8 (MH7— MH6) 6.1'± PROP MANHOLE MH8 3+07 RIM 1927.1 PIPE TABLE (SLOPES BASED ON 2D LENGTH TO INSIDE EDGES) PIPE NAME SIZE LENGTH SLOPE MATERIAL MH7 — MH8 8" 261' 0.5% PVC Pipe 40 SUBJECT PROPERTY Hwy 74 VICINITY MAP (NOT TO SCALE) DEVELOPMENT DATA CONTACT: CIVIL ENGINEER: CONTACT: CONTACT: PROJECT DATA PIN: ADDRESS: LAT: LONG: DEED BOOK/PAGE: SITE ACREAGE: RIVER BASIN: STREAM INDEX: CLASSIFICATION: ZONING: SETBACKS: DISTURBED AREA: PHASE I BUILDING DATA: KITUWAH LLC PO BOX 366 CHEROKEE, NC 28719 TRAVIS SMITH (828) 477-4145 CIVIL DESIGN CONCEPTS, P.A. 168 PATTON AVENUE ASHEVILLE, NC 28801 ROSS WALL, P.E. (828) 252-5388 AARON J. MCNEILL, PLS L-4224 P.O. BOX 2166 CHEROKEE, NC 28719 AARON J. MCNEILL (910) 690-3305 7604-12-4725 414 WHITTIER SCHOOL RD SWAIN COUNTY, NC 28719 469/56 5.12 ACRES TUCKASEGEE RIVER 2-79—(40.5) 2.45 AC BUILDING DESCRIPTION KAYLEIGH SINGLE FAMILY IMPERVIOUS CALCULATIONS: PHASE I: POST —DEVELOPMENT: FULL BUILD OUT: POST —DEVELOPMENT: SOIL TYPE SOIL GROUP: HEIGHT GFA 1 STORY 1,568SF IMPERVIOUS PERVIOUS 0.48 ACRES (9.3%) 4.68 ACRES (90.7%) 0.61 ACRES (12%) 4.54 ACRES (88%) IMPERVIOUS PERVIOUS 1.673 ACRES (32.5%) 3.482 ACRES (67.5%) BrC CDC INSPECTIONS HOTLINE: Know what's below. Call before you dig. 0 20 NORTH SEWER PLAN GRAPHIC SCALE 40 80 160 168 PATTON AVENUE co o co co Lo 0 co CO CO 1- LU CC cn cv co 0 cv co www.civildesignconcepts.com NCBELS LICENSE #: C-2184 cn LLI >- co SUBMITTAL PLAN SET EROSION CONTROL RESUBMITTAL SANITARY SEWER SUBMITTAL TWSA COMMENTS & FAST TRACK SUBMITTAL DESCRIPTION 0 00 0 CO 0 LLJ 0 CO CC SEWER PLAN FOR: SWAIN COUNTY, NORTH CAROLINA KITUWAH LLC DRAWN BY: RWW CDC PROJECT NO.: 22109 SHEET 1 inch = 40 ft. C701 FLEXIBLE MANHOLE SLEEVE OR ENTRANCE JOINT UNDISTURBED PIPE EMBEDMENT MATERIAL SECTION B-B CAST IRON FRAME & COVER BRICK _ ADJUSTMENT GROUTED OR PRECAST CONCRETE "U" SHAPED CHANNEL(S) FLEXIBLE MANHOLE SLEEVE OR ENTRANCE JOINT J MANHOLE STEPS SEE DETAIL 2"- PIPE EMBEDMENT "- UNDISTURBED MATERIAL 4'-8" MAXIMUM FOR CONCENTRIC CONE TOP MANHOLE CENTERLINE OF INLET PIPING IS NOT ALLOWED IN EITHER QUADRANT ADJOINING THE MANHOLE OUTLET. L GROUT INSIDE JOINT PIPE EMBEDMENT MATERIAL 6" PIPE EMBEDMENT MATERIAL NOTE: SECTION A -A MANHOLE STEPS TO BE VERTICALLY IN LINE WITH "INVERT OUT" FOR PIPE 18" AND LESS. OVER 18" TO BE LOCATED IN LINE WITH BENCH. STANDARD MANHOLE NOT TO SCALE NO SERVICE TO BE CONNECTED IN THIS QUADRANT CONSTRUCT SERVICE LINE AT 3/4 DIA. OF SEWER MAIN OR HIGHER FLOW PLAN SEWER SERVICE @ 1.00% SECTION A SECTIONAL PLAN DETAIL 'A" TRENCH WIDTH _ SECTION C-C SEWER SERVICE SERVICE CONNECTIONS AT MANHOLES NOT TO SCALE BACKFILL IN 6"-8" LIFTS & COMPACT TO 95% STANDARD PROCTOR IF NOT IN THE ROADWAY. BACKFILL IN 6"-8" LIFTS & COMPACT TO 98% STANDARD PROCTOR WHEN IN PAVED AREAS. UNDISTURBED EARTH TRACING TAPE 24" A OVE PIPE (PVC PIPE ONLY PIPE SPRING LINE NO. 12 COATED COPPER TRACING WIRE (PVC ONLY) PIPE EMBEDMENT MATERIAL OD 0 6 _ 6,. (MIN.) I � IN TIAL BACKFILL TRENCH FOR PVC PIPE (15" DIA. AND LESS) NOT TO SCALE PIPE EMBEDMENT MATERIAL MANHOLE STEPS 2 ROPES BUTYL RUBBER SEALANT NOTES: 1. PVC PIPES REQUIRE CLASS I PIPE EMBEDMENT MATERIALS. 2. WHEN TRENCH IS SUBJECT TO INUNDATION, EMBEDMENT MATERIALS MUST EXTEND TO TOP OF PIPE. 3. NO BOULDERS OR STONES IN EXCESS OF 4" WILL BE USED IN INITIAL BACKFILL. 4. THIS DETAIL IS VALID FOR PVC SEWER PIPE INSTALLED AT DEPTHS OF UP TO 20 FEET. 5. PVC PIPE NOT ALLOWED WITH LESS THAN 3'-0" COVER. TRENCH FOR PVC PIPE NOT TO SCALE 2' MAX. UNLESS OTHERWISE INDICATED COUNTERSUNK PVC PLUG IN -LINE WYE L L CLEANOUT BOX -, INSTALLED ON 8" OF COMPACTED PIPE EMBEDMENT MATERIALS BEND SEWER LATERAL CONSTRUC AT 2% GRADE UNLESS OTHERWISE INDICATED. 1" MIN. UNDISTURBED EARTH PROVIDE STONE BEDDING UNDER WYE (OR TAPPING SADDLE) AND BEND TE D CC W W > 0 J U ›- z CC w: 00 CC w I PVC REQUIRES BEDDING FULL LENGTH OF SERVICE TRENCH SHALL BE COMPACTED IN 6" LIFTS CONNECT TO EXISTING SEWER SERVICE WITH APPROVED COUPLING" OR INSTALL PLUG FOR FUTURE SERVICE. WHEN REQUIRED BACKFLOW VALVES SHALL BE INSTALLED ON PORTION OF LATERAL TO BE MAINTAINED BY PROPERTY OWNER. NOTES: 1. WYE CONNECTIONS ARE STANDARD FOR NEW SEWER MAIN CONSTRUCTION. 2. FOR EXISTING MAINS (12" OR SMALLER) WHERE WYES ARE NOT AVAILABLE A SEWER TAP SHALL BE INSTALLED BY MSD PERSONNEL. 3. FORCE MAINS CARRYING DOMESTIC WASTEWATER FROM SANITARY CONVENIENCES WITHIN A SINGLE BUILDING, MAY BE CONNECTED TO A 4" MSD GRAVITY SERVICE LINE PROVIDED THAT GRAVITY FLOW WILL BE MAINTAINED DURING PROPOSED MAXIMUM DISCHARGE RATE FOR THE GRINDER OR EFFLUENT PUMP(S). 4. 6" SERVICES REQUIRED FOR MULTI -UNIT BUILDINGS. 4" SERVICES ARE ALLOWED FOR SINGLE FAMILY RESIDENCES ONLY. 5. SCHEDULE 40 REQUIRED FOR ALL 4" SERVICES. SANITARY SEWER SERVICE NOT TO SCALE CAST IRON WITH "SEWER" CAST IN TOP III-Ij I -III 111111 -__ CLEANOUT PLUG NOTE: CLEANOUT BOX SHALL BE A CAST IRON VALVE BOX AS MANUFACTURED BY RUSSELL FOUNDRY, OPEILIKA FOUNDRY, OR EQUAL. 6" PLUG MINIMUM WEIGHT CHART MIN. WEIGHT-LBS. COVER 25 BASE 40 TOTAL UNIT 65 18" SQUARE CONCRETE PAD HOUSING #57 WASHED STONE 45° BEND 6"X 6" WYE NOTE: 6" SERVICES REQUIRED FOR MULTI -UNIT BUILDINGS. 4" SERVICES ARE ALLOWED FOR SINGLE FAMILY RESIDENCES ONLY. CLEANOUT DETAIL NOT TO SCALE :x 82" TO 88" 12"MIN. 6" SEWER LINE GROUND LEVEL COUNTERSUNK PLUG X w U z Q w J U z_ W 0 0 I- oI- 0 D m m0 CL U 0>w 0 0 J 0I-0 NOTE: 1. ALL SANITARY SEWER CLEAN OUT BOXES AND COVERS SHALL BE MANUFACTURED FROM GRAY IRON (CAST IRON) MEETING THE REQUIREMENTS OF AWWA C110 AND ASTM A536. 2. ALL SANITARY SEWER CLEAN OUT BOXES AND COVERS SHALL CONFORM TO PARAGRAPH 2.01(d) OF ITEM II, SECTION VI OF MSD'S TECHNICAL SPECIFICATIONS (MADE IN THE U.S.A). 3. SANITARY SEWER CLEAN OUT BOXES AND COVERS MANUFACTURED BY U.S FOUNDRY (HAND HOLE RING & FC COVER, MODEL #7610), EAST JORDAN IRON WORKS (HEAVY DUTY MONUMENT BOX, MODEL #1574) OR APPROVED EQUAL. U.S FOUNDRY (HAND HOLE RING & FC COVER, MODEL #7630) MAY BE USED WHERE CLEAN OUT IS WITHIN AN ASPHALT OR CONCRETE PAVED AREA. X z_ 7i" MIN. - 9' MAX 134" MIN. - 154" MAX. CLEANOUT BOX NOT TO SCALE 6"MIN. WASHED STONE BASE COUNTERSUNK PVC PLUG , J CLEANOUT BOX -' INSTALLED ON 8" OF COMPACTED PIPE EMBEDMENT MATERIALS PROPERTY LINE 2' MAX. UNLESS OTHERWISE INDICATED MIN. COVER 45° BEND CONNECT TO EXISTING SEWER SERVICE WITH APPROVED COUPLING" OR INSTALL PVC PLUG FOR FUTURE SERVICE. WHEN REQUIRED BACKFLOW VALVES SHALL BE INSTALLED ON PORTION OF LATERAL TO BE MAINTAINED BY PROPERTY OWNER. n GLUED CAP NOTE: CUT OFF EXTENSION TO CONNECT HOUSE SERVICE (PROVIDE MINIMUM COVER OF 30") AND INSTALL CLEAN -OUT NOTES: 1. WYE CONNECTIONS ARE STANDARD FOR NEW SEWER MAIN CONSTRUCTION. 2. FOR EXISTING MAINS (12" OR SMALLER) WHERE WYES ARE NOT AVAILABLE A SEWER TAP SHALL BE INSTALLED BY MSD PERSONNEL. 3. FORCE MAINS CARRYING DOMESTIC WASTEWATER FROM SANITARY CONVENIENCES WITHIN A SINGLE BUILDING, MAY BE CONNECTED TO A 4" MSD GRAVITY SERVICE LINE PROVIDED THAT GRAVITY FLOW WILL BE MAINTAINED DURING PROPOSED MAXIMUM DISCHARGE RATE FOR THE GRINDER OR EFFLUENT PUMP(S). 4. 6" SERVICES REQUIRED FOR MULTI -UNIT BUILDINGS. 4" SERVICES ARE ALLOWED FOR SINGLE FAMILY RESIDENCES ONLY. 5. SCHEDULE 40 REQUIRED FOR ALL 4" SERVICES. SANITARY SEWER SERVICE MORE THAN 5' DEEP NOT TO SCALE GROUT AROUND PIPE -TO BE FLUSH WITH INSIDE FACE OF BASE SECTION 1. MATERIAL SPECIFICATIONS: NEOPRENE BOOT - ASTM C-923; PIPE CLAMP & EXPANSION CLAMP - STAINLESS STEEL, ASTM C-923. 2. TWO PIPE CLAMPS REQUIRED FOR PIPE O.D.'S 15" AND LARGER. 3. FOR USE AS CONNECTIONS TO NEW OR EXISTING MANHOLES 0`IIIIIIIIIIIIIIIIIIII IIIIIIII I I M NOTF' ONLY ONE TRANSITION IN PIPE MATERIALS ALLOWED BETWEEN ANY TWO MANHOLES n n 4 ERIAL P GENERAL NOTES FOR SEWER 1. SEWER CONSTRUCTION ON THIS SITE MUST BE AUTHORIZED BY PERMITS ISSUED BY THE TUCKASEIGEE WATER AND SEWER AUTHORITY (TWSA). ALL SITEWORK SHALL BE IN ACCORDANCE WITH ALL LOCAL, STATE, AND NATIONAL REGULATORY STANDARDS; AND ALL REQUIREMENTS IN THE PROJECT TECHNICAL SPECIFICATIONS. REQUIREMENTS AND SPECIFICATIONS OF TWSA STANDARDS SUPERSEDE ALL OTHERS IN THE INSTALLATION OF THE PROPOSED SEWE XTENSIO 2. CONTRACTOR TO VERIFY WITH ENGINEER THAT THE REQUIRED SEWER PERMITS AND ASSOCIATED NON -SEWER PERMITS HAVE BEEN OBTAINED PRIOR TO BEGINNING CONSTRUCTION. 3. ALL CONSTRUCTION SHALL BE UNDER THE OBSERVATION OF THE ENGINEER, THE OWNER, TWSA. THE ENGINEER SHALL PERIODICALLY OBSERVE THE PROGRESS OF INSTALLATION AND SHALL COMPLETE A FINAL WATER AND SEWER INSPECTION. THE CONTRACTOR SHALL FURNISH, SECURE, AND PROVIDE ALL NECESSARY TESTING MATERIALS, EQUIPMENT, PROCEDURES, AND CERTIFIED LABORATORY TEST RESULTS FOR USE WITH ENGINEERS FINAL CERTIFICATION OF COMPLETION. ANY WORK COVERED PRIOR TO ENGINEER'S INSPECTION IS SUBJECT TO UNCOVERING AND BACKFILLING AT THE CONTRACTOR'S EXPENSE. 4. ALL WORK MUST BE PERFORMED BY A NORTH CAROLINA LICENSED UTILITY CONTRACTOR. 5. CONTRACTOR IS RESPONSIBLE FOR LOCATING AND VERIFYING THE EXACT LOCATION AND ELEVATION FOR ALL UTILITIES PRIOR TO CONSTRUCTION; AND TO NOTIFY ENGINEER OF ANY CONFLICTS OR DISCREPANCIES. THE LOCATION OF SOME UTILITIES SHOWN ON THE PLANS HAVE BEEN APPROXIMATED. ALL BURIED UTILITIES HAVE NOT BEEN SHOWN ON THE PLANS AND IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THEIR LOCATION PRIOR TO CONSTRUCTION. 6. CONTRACTOR SHALL PROTECT EXISTING AND NEWLY BUILT UTILITIES DURING CONSTRUCTION. ANY DAMAGE TO UTILITIES INCURRED DURING OR RESULTING FROM CONSTRUCTION ACTIVITY IS THE RESPONSIBILITY OF THE CONTRACTOR AND IS TO BE REPAIRED IN ACCORDANCE WITH APPLICABLE STANDARDS OF APPROPRIATE AGENCIES AT THE CONTRACTOR'S EXPENSE. 7. THE CONTRACTOR IS TO NOTIFY ALL UTILITY COMPANIES AT LEAST 72 HOURS BEFORE CONSTRUCTION ACTIVITY IS TO BEGIN. THE CONTRACTOR SHALL NOTIFY ULOCO AT 1-800-632-4949 OR 811, 72 HOURS BEFORE CONSTRUCTION BEGINS. NOTIFY THE ENGINEER AT LEAST 72 HOURS BEFORE STARTING CONSTRUCTION ACTIVITIES. 8. CONTRACTOR SHALL PROVIDE TWSA FIELD DENSITY REPORTS VERIFYING SEWER BUILT IN FILL AREAS ARE COMPACTED TO 95% STANDARD PROCTOR. 9. EROSION CONTROL IS FIELD PERFORMANCE BASED AND CONTRACTOR SHALL INSTALL AND MAINTAIN ANY EROSION CONTROL MEASURES NECESSARY TO ASSURE MAXIMUM PROTECTION OF THE SITE. CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL MEASURES REQUIRED TO CONTROL SEDIMENT DURING INSTALLATION ALL SEWER PIPES AND APPURTENANCES. 10. SAFETY AND TRAFFIC ROUTING TO BE COORDINATED WITH NCDOT AND IN STRICT ACCORDANCE WITH NCDOT GUIDELINES FOR CONSTRUCTION, MAINTENANCE, AND UTILITY OPERATIONS. 11. ALL SEWER SERVICES SHALL BE CONSTRUCTED IN ACCORDANCE WITH NC PLUMBING CODES AND ANY REQUIREMENTS PER LOCAL AUTHORITIES. COORDINATE EXACT LOCATIONS OF SERVICE LINES WITH THE ARCHITECTURAL, PLUMBING, AND LANDSCAPING PLANS. SEWER CLEANOUT ASSEMBLY LOCATIONS SHOWN ARE APPROXIMATE AND ARE CT TO FINAL VE ICATION. SUB 12. ALL UNDERGROUND MAIN AND SERVICE LINES OUTSIDE BUILDING FOOTPRINT SHALL BE REQUIRED TO HAVE A TRACEABLE MAGNETIC- TYPE WARNING TAPE INSTALLED IN THE BACKFILL AT LEAST 6" BELOW GRADE. 13. CONTRACTOR TO INSTALL D.I.P. WHERE THE MINIMUM OF 3' COVER OR AT UTILITY CROSSINGS WHERE MINIMUM VERTICAL SEPARATION REQUIREMENTS CANNOT BE MET. PIPE MATERIAL MUST TRANSITION TO D.I.P. 10' PRIOR TO CROSSING VIA A SOLID SLEEVE COUPLING AND EXTEND TO THE NEXT MANHOLE. 14. INSTALL FERROUS PIPING FOR BOTH WATER AND SEWER WITHIN 10' OF A CROSSING IF: A. SEWER LINE CROSSES OVER WATER, OR B. VERTICAL CLEARANCE BETWEEN WATER AND SEWER IS LESS THAN 18". MAINTAIN 10' HORIZONTAL SEPARATION BETWEEN SEWER AND WATER MAINS UNLESS LAID IN SEPARATE TRENCHES WITH THE BOTTOM OF THE WATER LINE AT LEAST 18" ABOVE THE TOP OF SEWER OR USE FERROUS MATERIAL FOR BOTH WATER AND SANITARY SEWER. 14. MAINTAIN 18" VERTICAL SEPARATION BETWEEN STORM DRAIN AND SANITARY SEWER, OR INSTALL FERROUS MATERIAL ON THE SANITARY SEWER WITHIN 10' EACH SIDE OF THE CROSSING. 15. CONTRACTOR RESPONSIBLE FOR ADJUSTING EXISTING WATER APPURTENANCES AS NECESSARY DUE TO ANY SITE CONSTRUCTION OR INSTALLATION. 16. TRENCH BACKFILL AND COMPACTION TESTING SHALL BE PERFORMED BY A CERTIFIED SOILS LABORATORY UNDER ALL PAVED AREAS. 17. THE ENTIRE SEWER EASEMENT MUST BE CLEAR AND REMAINED CLEARED OF TREE PLANTINGS, EXISTING TREES, AND ANY PERMANENT STRUCTURES. 18. CONTRACTOR SHALL SUPPLY THE ENGINEER WITH RECORD OF DEVIATIONS FROM PLANS FOR PREPARATION OF FINAL RECORD DRAWINGS. 19. THE PERMITS REQUIRE CERTIFICATION OF COMPLETION BY THE ENGINEER OF THE SEWER SYSTEMS PRIOR TO ISSUANCE OF FINAL OPERATION APPROVAL BY TWSA. SECURE FINAL OPERATIONAL APPROVAL FROM TWSA PRIOR TO ACTIVATION OF THE SYSTEM. 20. TESTING OF SEWER MAINS, MANHHOLES, AND SERVICES TO BE COORDINATED WITH TWSA A MINIMUM OF 48 HOURS IN ADVANCE. CONTACT BOBBY MORRIS AT 828-586-5189. SEWER DETAILS 168 PATTON AVENUE cco co CO N Z N W N J co 5 la =Z O a LS 4M'f 11, co CO o)COoV) yZ LCtj . Wla CNI J CO CO CC > w K co W Z O LL z a- 33 cv www.civildesignconcepts.com NCBELS LICENSE #: C-2184 m w m SUBMITTAL PLAN SET EROSION CONTROL RESUBMITTAL SANITARY SEWER SUBMITTAL TWSA COMMENTS & FAST TRACK SUBMITTAL DESCRIPTION N 0 N co 0 0 N 0 N 0 0 N 0 0 N 0 N 0 0 N N) 0 z °Nb ,P� NWza • w� SEWER DETAILS FOR: SWAIN COUNTY, NORTH CAROLINA KITUWAH LLC DRAWN BY: RWW CDC PROJECT NO.: 22109 SHEET C971