Loading...
HomeMy WebLinkAboutNCC214311_Site Plan or Location Map_202108020 N 0 c� 0 CD 0 0 0 0 0 0 0 0 Un U i / CD 0 / 0 0 03 i 0 U / 6 m 0 0 0 0 0 0 vi it Nc H 0 � 24 O O CLINTON RD. SITE 9a. Gam. \0611 Z_ FAYETTEVILLE, N.C. VICINITY MAP(N.T.S.) GRADING / EROSION CONTROL NOTES Q INSTALL GRAVEL CONSTRUCTION ENTRANCE (SEE CDC DETAIL) Qz INSTALL TEMPORARY SEDIMENT FENCE (SEE CDC DETAIL) Q INSTALL TEMPORARY SEDIMENT FENCE OUTLET (SEE CDC DETAIL) Q INSTALL TEMPORARY INLET PROTECTION (SEE CDC DETAIL) (D INSTALL RIPRAP VELOCITY DISSIPATOR (SEE CDC DETAIL) Q INSTALL ROCK PIPE INLET PROTECTION (SEE CDC DETAIL) Q INSTALL GRASS LINED SWALE (SEE CDC DETAIL) Qs INSTALL MATTING. SEE PLAN FOR TYPE AND DETAILS Q MINIMIZE FILL IN STREAM BED. PLACE MATTING WITHIN 7 DAYS. ADDITIONAL NOTES 1. ALL GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND OTHER INFORMATION INDICATED ON COVER SHEET SHALL APPLY TO THIS PLAN 2. ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE BENCHMARK AND MUST BE VERIFIED BY THE GENERAL CONTRACTOR WITH THE SURVEYOR OF RECORD PRIOR TO BEGINNING CONSTRUCTION. TEMPORARY BENCHMARK IS A NORTH CAROLINA GEO MARKER "VANDER RM3", LOCATED AT NORTH I NG-464925.87, EAST ING-2069182.49, OR 270 FEET NORTH-EAST OF CENTERLINE OF OLD VANDER ROAD. 3. PURSUANT TO G.S.113A-57(2), THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OR OTHER ADEQUATE EROSION CONTROL DEVICES OR STRUCTURES. IN ANY EVENT, SLOPES LEFT EXPOSED WILL, WITHIN 7 or 14 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY OR PERMANENT GROUND COVER, DEVICES OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION. PURSUANT TO G.S. 113A-57(3), PROVISIONS FOR PERMANENT GROUND COVER SUFFICIENT TO RESTRAIN EROSION MUST BE ACCOMPLISHED FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. ALL SEEDED AREAS WILL BE FERTILIZED, RE -SEEDED AS NECESSARY, AND MULCHED ACCORDING TO SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A VIGOROUS, DENSE VEGETATION COVER. IF ANY SEEDING FAILURE OCCURS, THOSE AREAS SHALL BE RE -SEEDED WITH RYE GRAIN FOR TEMPORARY STABILIZATION AND PREPARED FOR PERMANENT SEEDING. 4. SEE DETAIL SHEETS FOR EROSION CONTROL MEASURES & MAINTENANCE. 5. CONTACT PERSON: DOHN BROADWELL, (910)-484-5193. 6. PARCEL IDENTIFICATION NUMBER(S): 0476-15-0691. 7. CONTRACTOR SHALL REMOVE TEMPORARY EROSION CONTROL MEASURES ONLY AFTER REMOVAL HAS BE APPROVED BY DENR. 8. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING EROSION AND SEDIMENTATION CONTROL MONITORING ACCORDING TO NPDES PERMIT REQUIREMENTS. 9. SEE SHEET EROSION CONTROL DETAILS FOR TEMPORARY & PERMANENT SEEDING REQUIREMENTS. EROSION CONTROL CONSTRUCTION SEQUENCE 1. OBTAIN ALL NECESSARY PERMITS AND APPROVALS AND HOLD PRE -CONSTRUCTION CONFERENCE. 2. INSTALL GRAVEL CONSTRUCTION ENTRANCE. 3. INSTALL TEMPORARY SEDIMENT FENCE AND FENCE OUTLETS. 4. INSTALL SKIMMER BASINS 1 AND 2. 5. CLEAR AND GRUB ALL UNSUITABLE MATERIALS WITHIN THE LOC 6. INSTALL STORM DRAINS, INLET PROTECTION AND RIP RAP DISSIPATORS. 7. GRADE SITE. 8. CONSTRUCT SWALES AS PER TABLE AND PLANS. 9. MONITOR MEASURES, MAINTAIN, AND ADJUST PLAN TO ELIMINATE ANY SEDIMENT FROM LEAVING THE SITE. DWQ Construction General Permit Ground Stabilization Requirements Site Area Stabilization StabilizationTime Description Time Frame Frame Exceptions Perimeter dikes, swales, 7 days None ditches and slopes High Quality Water (HQW) 7 days None Zones If slopes are 10' or less in length Slopes steeper 7 days and are not than 3:1 steeper than 2:1, 14 days are allowed 7-days for Slopes 3:1 or 14 days slopes greater flatter than 50 feet in length None (except All other areas for perimeters with slopes 14 days and HQW flatter than 4:1 Zones) * "Extensions of time may be approved by the permitting authority based on weather or other site -specific condition that make compliance impracticable." (Sectio 11.13(2)(b)) -s---- s--- -------, I�o�,'�,","aa`P"w ORS Z_ �Z INV.=63.97 (PVC Pipe 8" IN-E) ------- --- - T-----------------T------- ;> C.I. #46 TOP=149.20 INV.=146.02 (Concrete Pipe 24" IN-W) INV.=146.02 (Concrete Pipe 24" OUT-E) SWALE 2 (GROUND COVER WITHIN 7 DAYS) SWALE 1 (GROUND COVER WITHIN 7 DAYS) Summary Swale Dimensions Start Start End End Bottom Top Req Top Min Side Length # Grnd Swale Grnd Swale Width B Width Width Slope Slopes Lining (See Detail) (ft) EL. (ft) EL. (ft) EL. (ft) EI. (ft) (ft) (10-yr) (10-yr) Z (ft) 1 520 149 145 0.51 1 3 6.06 9.00 0.77% 3 Excell SR-1 2 23 145.25 145 0.47 1 3 1 5.82 9.00 1 .09% 3 Excell SR-1 Note: Provide ground cover for all swales and diversion berms (berm &swale) within 7 days. Install straw waddle check dam every 1 00' (minimum) on all swales. CULVERTS Culvert DA (ac) Q-25 (cfs) Inv In Inv Out Diam (in) L (ft) Slope QTY Type Type Entrance Type Exit RRD W1 (ft) RRD W2 (ft) RRD L (ft) Type RR RRD Thickness (in) 1 2.90 7.52 145.50 145.25 18 48.0 0.52% 1 RCP FES FES 4.50 10.50 9 A 12in. 2 0.69 2.36 145.00 144.41 18 176.0 0.34% 1 RCP YI FES 4.50 11.50 10 A 12in. EX.3 13.43 25.21 142.85 142.57 24 56.0 0.50% 2 RCP FES FES 6.00 18.00 16 B 24in. 4 15.14 25.13 140.00 136.00 42 131.0 3.05% 1 RCP FES FES 10.50 15.50 12 B 15in. All Rip Rap Dissipaters (RRD) shall have filter fabric under Rip Rap and shall be excavated below Swale surface All lengths are from entrance to exit --including Flared End Sections (FES) ORROUS BAFFLES (SEE DETAIL) 2" Faircloth Skimmer (2" Orifice) See details (do not grade deep pools until conversion to wetland) SEE SCM 1 DETAIL 95 LF 15" RCP @ 5.28% See street and outfall plan and profiles for Curb inlets and related piping and other structures BAFFLES (SEE DETAIL) tl 2.5" Faircloth Skimmer (2.5" Orifice) See details trin not nrarla rlaan nnnlc SEE SCM 2 DETAIL Rip Rap Dissipater NUMBER DIAM Figure 8.06 a W_1 (ft) W-2 (ft) dmax min TH Nominal TH Type RR d-50 La ft in FES-48 24 0.30 10.0 6 12 0.45 5.40 8.1 15in. A FES-52 30 0.30 10.0 8 13 0.45 5.40 8.1 15in. A FES-30 1 30 0.30 10.0 8 13 0.45 5.40 8.1 1 15in. A Landscape Architecture ♦ Fayetteville, NC Civil Engineering ♦ Southern Pines, NC 230C W. Pennsylvania Ave. ♦ Southern Pines, NC 28387 Voice: 910-725-1107 w w w. c r a w f o r d d s n. c o m DES I GN �,QOQ E ARL7{ 9 T 7 CERT. No. C-136 2 P T ORTH CARC' S E A L S ,,,���Q DES I G/ ,',* \NEER//�., O�,gC0 j CERT. No. C-2097 z 0 CA Cill G P Preliminary REVISIONS 0 --- mm-dd-yy Description Z 0 0 in J JWo J LL 00 WWW LU D Cl) Q�Q 0 JJ= m W Z AX W Q J LLI QO Z 0. Q Z 00 Vn^ U Z zp_ 0 U) a0 r� � V w PROJECT DETAILS Project Manager: KSL CAD Technician: RFN/GER Reviewed / Approved By: Project Number: 18009 S o,00 zo Full Scale: Horiz.: 1" = 100' Half Scale: Horiz.: 1" = 200' ISSUE DATE 05/15/2021 SHEET NUMBER C3.0