HomeMy WebLinkAboutNC0061719_WWTP Inspection_20070501Michael F. Easley, Governor. William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality May 1, 2007 Michael Harwood, Compliance Engineering Manager Heater Utilities Inc Owned By Aqua NC 202 Mackenan Ct Cary NC 27511 SUBJECT: April 26, 2007 Compliance Evaluation Inspection Heater Utilities Inc Owned By Aqua NC Woodlake Country Club WWTP Permit No: NC0061719 Moore County Dear Mr Harwood: Enclosed please find a copy of the Compliance Evaluation Inspection Report from the inspection conducted on April 26, 2007 by Hughie White of the Fayetteville Regional Office. The facility was found to be in Compliance - with permit NC0061719. As a reminder, since Aqua North Carolina has recently contracted operation of the Woodlake facility to Envirolink, a new ORC designation form needs to be submitted to the Division on behalf of Mr. Lamm. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff has, any questions, please call me at 910-433-3308. cc: William Lamm, ORC Tim Thomas, Aqua NC Central Files Fayetteville Files Sincerely, dek-' Hughie White Environmental Specialist Nnc orthCarolina Naturally North Carolina Division of Water Quality 225 Green Street— Suite 714 Fayetteville, NC 28301-5043 Phone (910) 486-1541 Customer Service Internet: h2o.enr.state.nc.us FAX (910) 486-0707 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled/10% Post Consumer Paper United States Environmental Protection Agency EPA Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 1 1 NI 2 151 31 NC0061719 1 11 121 07/04/26 117 Type Inspector Fac Type 181 c1 19[ j 201 11 11�= �- 1 1111 1111111111166 Remarks 211111 1111 1 1 1 1 1111 1 11 1 111 1 1111 111 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved 671 1 69 701 3 I 711 1 721 NI 731 1 174 751 I 1 1 1 1 1 180 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Woodlake Country Club WWTP Merganser Way Vass NC 28394 Entry Time/Date 10:15 AM 07/04/26 Permit Effective Date 06/06/01 Exit Time/Date 12:15 PM 07/04/26 Permit Expiration Date 11/05/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// William Edward Lamm/ORC/252-235-4900/ Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Michael Harwood,202 Mackenan Ct Cary NC 27511//919-467-8712/9194601 8 Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 1 Flow Measurement Operations & Maintenance Self -Monitoring Program • Sludge Handling Disposal • Facility Site Review Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative Waters as necessary) Records/Reports Effluent/Receiving and checklists (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Hughie White ..- FRO WQ//910-433-3300 Ext.708/ �'j a�` 5/f/07 Signature of Management Q AReaviie/wA.er j•gte Agency/Office/Phone and Fax Numbers Datee1 �yBelinda S Henson K}'W�'/ FRO WQ//910-433-3300 Ext.726/ 61/410 / EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 31 NPDES NC0061719 111 121 yr/mo/day 07/04/26 Inspection Type 181cl (cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Laboratory data was reviewed. All data appeared to be correct as reported on the DMR's. Calibration records were properly documented. When needed, sludge disposal is performed by McGiII Environmental. As part of the inspection, a review for Field Parameter Certification was performed. All requirements for that certification appeared to be met. Since the last inspection, this facility has been issued a new NPDES permit. The new permit states that a Total Residual Chlorine limit will become effective on December 1, 2007. There are' no plans to intall a de -chlorination unit at this facility. Instead, the tentative plans are to eliminate the liquid disinfection unit and install an ultraviolet disinfection unit. Please be advised that this new unit would need to be in place by December 1 of this year. Page # 2 ti. Permit: NC0061719 Owner - Facility: Woodlake Country Club WWTP Inspection Date: 04/26/2007 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ■ ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ ❑ ❑ ❑ Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? `❑ ❑ ■ ❑ Is the facility as described in the permit? ■ ❑ ❑ ❑ # Are there any special conditions for the permit? ■ ❑ ❑ ❑ Is access to the plant site restricted to the general public? ■ ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: This facility will have a Total Residual Chlorine limit that will become effective on December 1, 2007. Bar Screens Type of bar screen a.Manual ■ b.Mechanical ❑ Are the bars adequately screening debris? ■ ❑ ❑ ❑ Is the screen free of excessive debris? ■ ❑ ❑ ❑ Is disposal of screening in compliance? • ❑ ❑ ❑ Is the unit in good condition? ■ ❑ ❑ ❑ Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? ■ ❑ ❑ ❑ Is flow meter calibrated annually? ■ ❑ ❑ ❑ Is the flow meter operational? ■ ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? 0 0 0 • Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 0 v 0 Are the receiving water free of foam other than trace amounts and other debris? ■ ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ 0 ■ 0 Yes No NA NE Page # 3 Permit: NC0061719 Owner - Facility: Woodlake Country Club WWTP Inspection Date: 04/26/2007 Inspection Type: Compliance Evaluation Effluent Pipe Yes No NA NE Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? ■ ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ❑ ❑ ■ ❑ Are weirs level? ■ ❑ n ❑ Is the site free of weir blockage? ■ ❑ ❑ ❑ Is the site free of evidence of short-circuiting? moon Is scum removal adequate? 00110 Is the site free of excessive floating sludge? ■ ❑ ❑ ❑ Is the drive unit operational? ❑ ❑ ■ ❑ Is the return rate acceptable (low turbulence)? 0 0 0 ■ Is the overflow clear of excessive solids/pin floc? l n ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) ❑ ❑ ❑ ■ Comment: Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? ■ ❑ ❑ ❑ Are surface aerators and mixers operational? 0 0 ■ 0 Are the diffusers operational? • ❑ n ❑ Is the foam the proper color for the treatment process? • ❑ n ❑ Does the foam cover less than 25% of the basin's surface? ■ ❑ ❑ ❑ Is the DO level acceptable? 0 0 0 ■ Is the DO level acceptable?(1.0 to 3.0 mg/I) 0 ❑ 0 ■ Comment: Standby Power Yes No NA NE Is automatically activated standby power available? ■ ❑ ❑ ❑ Is the generator tested by interrupting primary power source? 0 ❑ ❑ ❑ Is the generator tested under load? r n ❑ ❑ Was generator tested & operational during the inspection? 0 0 0 • Page # 4 Permit: NC0061719 Owner - Facility: Woodlake Country Club WWTP Inspection Date: 04/26/2007 Inspection Type: Compliance Evaluation Standby Power Yes No NA NE Do the generator(s) have adequate capacity to operate the entire wastewater site? in n ❑ ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up power? ❑ ❑ ❑ ■ Is the generator fuel level monitored? n ❑ ❑ ■ Comment: Disinfection -Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? 'Irmo (Sodium Hypochlorite) Is pump feed system operational? 0 n n n Is bulk storage, tank containment area adequate? (free of leaks/open drains) ■ ❑ ❑ n Is the level of chlorine residual acceptable? ❑ ❑ ❑ ■ Is the contact chamber free of growth, or sludge buildup? ■ n ❑ ❑ Is there chlorine residual prior to de -chlorination? n n ■ ❑ Comment: Dechlorination is not being performed as of yet at this facility. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ® n ❑ ❑ Is sample collected below all treatment units? ■ n n n Is proper volume collected? ■ n ❑ ❑ Is the tubing clean? • n n 0 Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? ■ ❑ n ❑ Is the facility sampling performed as required by the permit (frequency, sampling type representative)? ■ n ❑ n Comment: Aerobic Digester Yes No NA NE Is the capacity adequate? ■ n 0 ❑ Is the mixing adequate? ❑ n n ■ Is the site free of excessive foaming in the tank? n n n ■ # Is the odor acceptable? ❑ ❑ ❑ • # Is tankage available for properly waste sludge? ■ ❑ ❑ ❑ Comment: Page # 5 Vame of site to be Inspected: =field certification # (ifapplicable):. 505 / 1PDES #:. !1Jc DO & 171.9 Region:• I. Circle the parameter or parameters performed at this site: Residual Chlorin Settleable Solids,OConductivity�l emRerature II..Instrumentation: Does the facility have the equipment necessaryto analyze e field parameters as circled above? 1. A pH. meter No 2. A Residual Chlorine meter 3. DO meter 4. A Cone for settleable solids 5. A thermometer ormeter that measures temperature. 5. Conductivity meter III. Calibration/Analysis: 1. Is the pH metercalibrated with a 2 buffers and checked with a third buffer each day of use? 2. For Total Residual Chlorine, is a check standard analyzed each day of use? 3. Is the air calibration: of the:DO meter performed each day of use? 4. For Settleable Solids, is.1.liter of sample settled for 1 hour? : 5. Is the temperature measuring device calibrated annually against a certified thermometer? 6. For Conductivity, is a calibration standard analyzed each day of use? Yes Yes Yes Yes. No • No IV. Documentation: 1. Is thedate and time that the sample was collected documented? 2, Is the sampl&site documented? :. 3. Is the sample collector documented? 4. Is the analysis date and time documented? 5.:Did theanalyst sign the .documentation? 6. Is record of calibration documented? 7. For Settleable, Solids, is sample; volume an 1 hour time settling time documented? 8. For Temperature, is the annual calibration of the measuring device documented? Comments: No Please submit a copy of this completed. form to the Laboratory Certification Program. DWQ Lab Certification Chemistry Lab Courier # 52-01.-01 FIELD INSPECTOR CHECKLIST REV. 04/23/2002 North Carolina, Mr. Hughie White Environmental Specialist Fayetteville Regional Office, NC DWQ 225 Green Street — Suite 714 Fayetteville, NC 28301-5043 Dear Mr. White, Reid Campbell, P.E. Aqua North Carolina 202 MacKenan Ct. Cary, North Carolina 27511 June 1, 2007 Regional Manager - Compliance T: 919.467.8712 F: 919.460.1788 email: racampbell@aquaamerica.com DENR-FRO .9 U 5 2007 [WV I am writing in response to your Compliance Evaluation Inspection form for the Woodlake WWTP, dated May 1, 2007. In the letter you discuss the inspection details and review of the self -monitoring data. We were glad that you found the facility to be in compliance with its permit requirements. We will be submitting a new ORC designation form to the Division shortly. If you have any questions about this issue please contact me at (919) 467-8712. Sincerely, -e Reid Campbell, P.E. Regional Manager, Compliance Aqua North Carolina cc: William Lamm, ORC